Skip to main content
Erschienen in: Clinical Orthopaedics and Related Research® 2/2010

01.02.2010 | Symposium: Papers Presented at the Hip Society Meetings 2009

Incidence of ‘Squeaking’ After Ceramic-on-Ceramic Total Hip Arthroplasty

verfasst von: Kenny Mai, MD, Christopher Verioti, DO, Kace A. Ezzet, MD, Steven N. Copp, MD, Richard H. Walker, MD, Clifford W. Colwell Jr., MD

Erschienen in: Clinical Orthopaedics and Related Research® | Ausgabe 2/2010

Einloggen, um Zugang zu erhalten

Abstract

The incidence of hip “squeak” associated with ceramic-on-ceramic bearings has been variably reported, ranging from 0.7% to 20.9%. We determined the patients’ perception of squeaking in 306 patients (336 hips) in whom ceramic-on-ceramic total hip arthroplasties (THAs) were performed between 1997 and 2005. A questionnaire regarding hip noise was obtained by telephone. With a minimum followup of 2 years (mean, 3.9 years; range, 2–10 years), 290 patients (320 or 95% of the THAs) completed the questionnaire. Patients reported hip noise in 55 of the 320 THAs (17%); noise was perceived as squeak in 32 of the 320 (10%). Most squeaking hips (29 of 32) were pain-free and symptom-free. One patient was unhappy with his squeaking hip without pain. Our data suggest a much higher incidence of squeak as perceived by patients than previously reported.
Level of Evidence: Level II, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Bierbaum BE, Nairus J, Kuesis D, Morrison JC, Ward D. Ceramic-on-ceramic bearings in total hip arthroplasty. Clin Orthop Relat Res. 2002;405:158–163.CrossRefPubMed Bierbaum BE, Nairus J, Kuesis D, Morrison JC, Ward D. Ceramic-on-ceramic bearings in total hip arthroplasty. Clin Orthop Relat Res. 2002;405:158–163.CrossRefPubMed
2.
Zurück zum Zitat Clarke IC, Manley MT. How do alternative bearing surfaces influence wear behavior? Implant Wear Symposium 2007 Engineering Work Group. J Am Acad Orthop Surg. 2008;16(Suppl 1):S86–S93.PubMed Clarke IC, Manley MT. How do alternative bearing surfaces influence wear behavior? Implant Wear Symposium 2007 Engineering Work Group. J Am Acad Orthop Surg. 2008;16(Suppl 1):S86–S93.PubMed
3.
Zurück zum Zitat Colwell CW Jr, Hozack WJ, Mesko JW, D’Antonio JA, Bierbaum BE, Capello WN, Jaffe WL, Mai KT. Ceramic-on-ceramic total hip arthroplasty early dislocation rate. Clin Orthop Relat Res. 2007;465:155–158.PubMed Colwell CW Jr, Hozack WJ, Mesko JW, D’Antonio JA, Bierbaum BE, Capello WN, Jaffe WL, Mai KT. Ceramic-on-ceramic total hip arthroplasty early dislocation rate. Clin Orthop Relat Res. 2007;465:155–158.PubMed
4.
Zurück zum Zitat D’Antonio JA, Capello WN, Manley MT, Naughton M, Sutton K. A titanium-encased alumina ceramic bearing for total hip arthroplasty: 3- to 5-year results. Clin Orthop Relat Res. 2005;441:151–158.CrossRefPubMed D’Antonio JA, Capello WN, Manley MT, Naughton M, Sutton K. A titanium-encased alumina ceramic bearing for total hip arthroplasty: 3- to 5-year results. Clin Orthop Relat Res. 2005;441:151–158.CrossRefPubMed
5.
Zurück zum Zitat Garino JP. Modern ceramic-on-ceramic total hip systems in the United States: early results. Clin Orthop Relat Res. 2000;379:41–47.CrossRefPubMed Garino JP. Modern ceramic-on-ceramic total hip systems in the United States: early results. Clin Orthop Relat Res. 2000;379:41–47.CrossRefPubMed
6.
Zurück zum Zitat Hamadouche M, Boutin P, Daussange J, Bolander ME, Sedel L. Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study. J Bone Joint Surg Am. 2002;84:69–77.PubMed Hamadouche M, Boutin P, Daussange J, Bolander ME, Sedel L. Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study. J Bone Joint Surg Am. 2002;84:69–77.PubMed
7.
Zurück zum Zitat Hannouche D, Hamadouche M, Nizard R, Bizot P, Meunier A, Sedel L. Ceramics in total hip replacement. Clin Orthop Relat Res. 2005;430:62–71.CrossRefPubMed Hannouche D, Hamadouche M, Nizard R, Bizot P, Meunier A, Sedel L. Ceramics in total hip replacement. Clin Orthop Relat Res. 2005;430:62–71.CrossRefPubMed
8.
Zurück zum Zitat Jarrett CA, Ranawat AS, Bruzzone M, Blum YC, Rodriguez JA, Ranawat CS. The squeaking hip: a phenomenon of ceramic-on-ceramic total hip arthroplasty. J Bone Joint Surg Am. 2009;91:1344–1349.CrossRefPubMed Jarrett CA, Ranawat AS, Bruzzone M, Blum YC, Rodriguez JA, Ranawat CS. The squeaking hip: a phenomenon of ceramic-on-ceramic total hip arthroplasty. J Bone Joint Surg Am. 2009;91:1344–1349.CrossRefPubMed
9.
Zurück zum Zitat Keurentjes JC, Kuipers RM, Wever DJ, Schreurs BW. High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings. Clin Orthop Relat Res. 2008;466:1438–1443.CrossRefPubMed Keurentjes JC, Kuipers RM, Wever DJ, Schreurs BW. High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings. Clin Orthop Relat Res. 2008;466:1438–1443.CrossRefPubMed
10.
Zurück zum Zitat Murphy SB, Ecker TM, Tannast M. Two- to 9-year clinical results of alumina ceramic-on-ceramic THA. Clin Orthop Relat Res. 2006;453:97–102.CrossRefPubMed Murphy SB, Ecker TM, Tannast M. Two- to 9-year clinical results of alumina ceramic-on-ceramic THA. Clin Orthop Relat Res. 2006;453:97–102.CrossRefPubMed
11.
Zurück zum Zitat Restrepo C, Parvizi J, Kurtz SM, Sharkey PF, Hozack WJ, Rothman RH. The noisy ceramic hip: is component malpositioning the cause? J Arthroplasty. 2008;23:643–649.CrossRefPubMed Restrepo C, Parvizi J, Kurtz SM, Sharkey PF, Hozack WJ, Rothman RH. The noisy ceramic hip: is component malpositioning the cause? J Arthroplasty. 2008;23:643–649.CrossRefPubMed
12.
Zurück zum Zitat Rodriguez JA, Gonzalez DelaValle A, McCook N. Squeaking in total hip replacement: a cause for concern. Orthopedics. 2008;31:874, 877–878. Rodriguez JA, Gonzalez DelaValle A, McCook N. Squeaking in total hip replacement: a cause for concern. Orthopedics. 2008;31:874, 877–878.
13.
Zurück zum Zitat Sedel L. Evolution of alumina-on-alumina implants: a review. Clin Orthop Relat Res. 2000;379:48–54.CrossRefPubMed Sedel L. Evolution of alumina-on-alumina implants: a review. Clin Orthop Relat Res. 2000;379:48–54.CrossRefPubMed
14.
Zurück zum Zitat Taylor S, Manley MT, Sutton K. The role of stripe wear in causing acoustic emissions from alumina ceramic-on-ceramic bearings. J Arthroplasty. 2007;22(Suppl 3):47–51.CrossRefPubMed Taylor S, Manley MT, Sutton K. The role of stripe wear in causing acoustic emissions from alumina ceramic-on-ceramic bearings. J Arthroplasty. 2007;22(Suppl 3):47–51.CrossRefPubMed
15.
Zurück zum Zitat Walter WL, Insley GM, Walter WK, Tuke MA. Edge loading in third generation alumina ceramic-on-ceramic bearings: stripe wear. J Arthroplasty. 2004;19:402–413.CrossRefPubMed Walter WL, Insley GM, Walter WK, Tuke MA. Edge loading in third generation alumina ceramic-on-ceramic bearings: stripe wear. J Arthroplasty. 2004;19:402–413.CrossRefPubMed
16.
Zurück zum Zitat Walter WL, O’Toole GC, Walter WK, Ellis A, Zicat BA. Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation. J Arthroplasty. 2007;22:496–503.CrossRefPubMed Walter WL, O’Toole GC, Walter WK, Ellis A, Zicat BA. Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation. J Arthroplasty. 2007;22:496–503.CrossRefPubMed
17.
Metadaten
Titel
Incidence of ‘Squeaking’ After Ceramic-on-Ceramic Total Hip Arthroplasty
verfasst von
Kenny Mai, MD
Christopher Verioti, DO
Kace A. Ezzet, MD
Steven N. Copp, MD
Richard H. Walker, MD
Clifford W. Colwell Jr., MD
Publikationsdatum
01.02.2010
Verlag
Springer-Verlag
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 2/2010
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-009-1083-4

Weitere Artikel der Ausgabe 2/2010

Clinical Orthopaedics and Related Research® 2/2010 Zur Ausgabe

Symposium: Papers Presented at the Hip Society Meetings 2009

Proximally Versus Fully Porous-coated Femoral Stems: A Multicenter Randomized Trial

Symposium: Papers Presented at the Hip Society Meetings 2009

The Learning Curve for Adopting Hip Resurfacing Among Hip Specialists

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.