Skip to main content
Erschienen in: European Spine Journal 3/2006

01.08.2006 | Review

Injectable biomaterials and vertebral endplate treatment for repair and regeneration of the intervertebral disc

verfasst von: Lawrence M. Boyd, Andrew J. Carter

Erschienen in: European Spine Journal | Sonderheft 3/2006

Einloggen, um Zugang zu erhalten

Abstract

The objectives of augmentation of the nucleus pulposus following disc removal are to prevent disc height loss and the associated biomechanical and biochemical changes. Flowable materials may be injected via a small incision, allowing minimally invasive access to the disc space. Fluids can interdigitate with the irregular surgical defects and may even physically bond to the adjacent tissue. Injectable biomaterials allow for incorporation and uniform dispersion of cells and/or therapeutic agents. Injectable biomaterials have been developed that may act as a substitute for the disc nucleus pulposus. Our work has focused on the evaluation of a recombinant protein copolymer consisting of amino acid sequence blocks derived from silk and elastin structural proteins as an injectable biomaterial for augmentation of the nucleus pulposus. This implant, NuCore™ Injectable Nucleus is being developed by Spine Wave (Shelton, CT). The NuCore™ material is comprised of a solution of the protein polymer and a polyfunctional cross-linking agent. The material closely mimics the protein content, water content, pH and complex modulus of the natural nucleus pulposus. Extensive mechanical testing, biocompatibility and toxicology testing have been performed on the material. Characterization studies indicate that the NuCore™ Injectable Nucleus is able to restore the biomechanics of the disc following a microdiscectomy. Extensive biomaterial characterization shows the material to be non-toxic and biocompatible. The mechanical properties of the material mimic those of the natural nucleus pulposus. Thus NuCore™ Injectable Nucleus is suitable to replace the natural nucleus pulposus following a discectomy procedure. Human clinical evaluation is underway in a multi center clinical study on the use of the material as an adjunct to microdiscectomy. Further clinical studies of the use of NuCore™ Injectable Nucleus for treatment of early stage degenerative disc disease are planned in the near future. On-going efforts are characterizing the use of the material as a cell delivery vehicle for disc repair and reconstruction. Related development efforts are exploring methods for repair and regeneration of the cartilage endplate that are implemented to enhance the host-implant interface. Prior to the introduction of the above-mentioned biomaterial, our work proposes to utilize a process for the treatment of the vertebral endplates. The goal of this process is to restore the endplates as closely as possible to their natural state prior to disease or degeneration. The nature of the treatment will depend upon the form of the endplate degeneration and on the type of scaffolding that is intended to be introduced in the nuclear cavity. Endplate therapy is a potential means of enhancing biomaterial integration and cell survival, but remains a long-term and currently untested methodology.
Literatur
1.
Zurück zum Zitat Adams MA, Bogduk N, Burton K, Dolan P (2002) Summary: spinal ageing, degeneration and pain. In: Adams MA, Bogduk N, Burton K, Dolan P (eds) The biomechanics of back pain. Churchill Livingstone, New York, pp 197–203 Adams MA, Bogduk N, Burton K, Dolan P (2002) Summary: spinal ageing, degeneration and pain. In: Adams MA, Bogduk N, Burton K, Dolan P (eds) The biomechanics of back pain. Churchill Livingstone, New York, pp 197–203
2.
Zurück zum Zitat Adams MA, Hutton WC (1983) The effects of posture on the fluid content of lumbar intervertebral discs. Spine 8:665–671PubMedCrossRef Adams MA, Hutton WC (1983) The effects of posture on the fluid content of lumbar intervertebral discs. Spine 8:665–671PubMedCrossRef
3.
Zurück zum Zitat Atlas SJ, Deyo RA, Ancker Mvd, Singer DE, Keller RB, Patrick DL (2003) The Maine-Seattle back questionnaire: A 12-item disability questionnaire for evaluating patients with lumbar sciatica or stenosis. Spine 28:1869–1876PubMedCrossRef Atlas SJ, Deyo RA, Ancker Mvd, Singer DE, Keller RB, Patrick DL (2003) The Maine-Seattle back questionnaire: A 12-item disability questionnaire for evaluating patients with lumbar sciatica or stenosis. Spine 28:1869–1876PubMedCrossRef
4.
Zurück zum Zitat Bao Q-BH, Yuan A (2001) Implantable tissue repair device. Patent 6,224,630 Bao Q-BH, Yuan A (2001) Implantable tissue repair device. Patent 6,224,630
5.
Zurück zum Zitat Benneker LM, Heini PF, Anderson SE, Ito K (2005) Young investigator award winner: vertebral endplate marrow contact channel occlusions and intervertebral disc degeneration. Spine 7:97–102 Benneker LM, Heini PF, Anderson SE, Ito K (2005) Young investigator award winner: vertebral endplate marrow contact channel occlusions and intervertebral disc degeneration. Spine 7:97–102
6.
Zurück zum Zitat Bernick S, Cailliet R (1982) Vertebral end-plate changes with aging of human vertebrae. Spine 7:97–102PubMedCrossRef Bernick S, Cailliet R (1982) Vertebral end-plate changes with aging of human vertebrae. Spine 7:97–102PubMedCrossRef
7.
Zurück zum Zitat Bibby SRS, Jones DA, Ribley RM, Urban JPG (2005) Metabolism of the intervertebral disc: effects of low levels of oxygen, glucose, and pH on rates of energy metabolism of bovine nucleus pulposus cells. Spine 30:487–496PubMedCrossRef Bibby SRS, Jones DA, Ribley RM, Urban JPG (2005) Metabolism of the intervertebral disc: effects of low levels of oxygen, glucose, and pH on rates of energy metabolism of bovine nucleus pulposus cells. Spine 30:487–496PubMedCrossRef
8.
Zurück zum Zitat Boos N, Weissbach S, Rohrbach H, Weiler C, Spratt KF, Nerlich AG (2002) Classification of age-related changes in lumbar intervertebral discs. Spine 27:2631–2644PubMedCrossRef Boos N, Weissbach S, Rohrbach H, Weiler C, Spratt KF, Nerlich AG (2002) Classification of age-related changes in lumbar intervertebral discs. Spine 27:2631–2644PubMedCrossRef
9.
Zurück zum Zitat Bos PK, DeGroot J, Budde M, Verhaar JA, Osch GJv (2002) Specific enzymatic treatment of bovine and human articular cartilage: Implications for integrative cartilage repair. Arthritis Rheum. 46:976–985PubMedCrossRef Bos PK, DeGroot J, Budde M, Verhaar JA, Osch GJv (2002) Specific enzymatic treatment of bovine and human articular cartilage: Implications for integrative cartilage repair. Arthritis Rheum. 46:976–985PubMedCrossRef
10.
Zurück zum Zitat Bravenboer JvdB, Maur CDId, Bos PK, Feenstra L, Verhaar JA, Weinans H, van Osch GJVM (2005) Improved cartilage integration and interfacial strength after enzymatic treatment in a cartilage transplantation model. Arthritis Res Therapy 6:469–476CrossRef Bravenboer JvdB, Maur CDId, Bos PK, Feenstra L, Verhaar JA, Weinans H, van Osch GJVM (2005) Improved cartilage integration and interfacial strength after enzymatic treatment in a cartilage transplantation model. Arthritis Res Therapy 6:469–476CrossRef
11.
Zurück zum Zitat Brinckmann P, Grootenboer H (1991) Change of disc height, radial disc bulge, and intradiscal pressure from discectomy: an in vitro investigation of human lumbar discs. Spine 16:641–646PubMedCrossRef Brinckmann P, Grootenboer H (1991) Change of disc height, radial disc bulge, and intradiscal pressure from discectomy: an in vitro investigation of human lumbar discs. Spine 16:641–646PubMedCrossRef
12.
Zurück zum Zitat Brodin H (1955) Paths of nutrition in articular cartilage and intervertebral discs. Acta Orthop Scand 24:177–183PubMed Brodin H (1955) Paths of nutrition in articular cartilage and intervertebral discs. Acta Orthop Scand 24:177–183PubMed
13.
Zurück zum Zitat Buschmann MD, Gluzband YA, Grodzinsky AJ, Huziker EB (1995) Mechanical compression modulates matrix biosynthesis in chondrocyte/agarose culture. J Cell Sci 108:1497–1508PubMed Buschmann MD, Gluzband YA, Grodzinsky AJ, Huziker EB (1995) Mechanical compression modulates matrix biosynthesis in chondrocyte/agarose culture. J Cell Sci 108:1497–1508PubMed
14.
Zurück zum Zitat Caplan AI, Elyaderani M, Mochizuki Y, Wakatani S, Goldberg VM (1997) Overview: Principles of cartilage repair and regeneration. Clin Orthop Rel Res 342:254–269CrossRef Caplan AI, Elyaderani M, Mochizuki Y, Wakatani S, Goldberg VM (1997) Overview: Principles of cartilage repair and regeneration. Clin Orthop Rel Res 342:254–269CrossRef
15.
Zurück zum Zitat Cappello J (1996) Genetically engineered protein polymers. In: Domb AJ, Kost J, Wiseman D (eds) Handbook of degradable polymers. Harwood Academic Publishers, Amsterdam, pp 387–414 Cappello J (1996) Genetically engineered protein polymers. In: Domb AJ, Kost J, Wiseman D (eds) Handbook of degradable polymers. Harwood Academic Publishers, Amsterdam, pp 387–414
16.
Zurück zum Zitat Cappello J Ferrari F (1994) Microbial production of structural protein polymers. In: Mobley DP (ed) Plastics from microbes. Carl Hanser Verlag, Munich, pp 35–92 Cappello J Ferrari F (1994) Microbial production of structural protein polymers. In: Mobley DP (ed) Plastics from microbes. Carl Hanser Verlag, Munich, pp 35–92
17.
Zurück zum Zitat Cappello JE, Stedronsky R (2002) Synthetic proteins for in vivo drug delivery and tissue augmentation, U.S. Patent 6,380,154 Cappello JE, Stedronsky R (2002) Synthetic proteins for in vivo drug delivery and tissue augmentation, U.S. Patent 6,380,154
18.
Zurück zum Zitat Carragee EJ, Han MY, Yang B, Kim DH, Kraemer H, Billys J (1999) Activity restrictions after posterior lumbar discectomy: a prospective study of outcomes in 152 cases with no postoperative restrictions. Spine 24:2346–2351PubMedCrossRef Carragee EJ, Han MY, Yang B, Kim DH, Kraemer H, Billys J (1999) Activity restrictions after posterior lumbar discectomy: a prospective study of outcomes in 152 cases with no postoperative restrictions. Spine 24:2346–2351PubMedCrossRef
19.
Zurück zum Zitat Chandraraj S, Briggs CA, Opeskin K (1998) Disc herniations in the young and end-plate vascularity. Clin Anat 11:171–176PubMedCrossRef Chandraraj S, Briggs CA, Opeskin K (1998) Disc herniations in the young and end-plate vascularity. Clin Anat 11:171–176PubMedCrossRef
20.
Zurück zum Zitat Chen J, Yan W, Setton LA (2004) Static compression induces zonal-specific changes in gene expression for extracellular matrix and cytoskeletal proteins in intervertebral disc cells in vitro. Matrix Biol 22:573–583PubMedCrossRef Chen J, Yan W, Setton LA (2004) Static compression induces zonal-specific changes in gene expression for extracellular matrix and cytoskeletal proteins in intervertebral disc cells in vitro. Matrix Biol 22:573–583PubMedCrossRef
21.
Zurück zum Zitat Chenite A, Chaput C, Wang D, Combes C, Buschmann MD, Hoemann CD, Leroux JC, Atkinson BL, Binette F, Selmani A (2000) Novel injectable neutral solutions of chitosan form biodegradable gels in situ. Biomaterials 21:2155–2161PubMedCrossRef Chenite A, Chaput C, Wang D, Combes C, Buschmann MD, Hoemann CD, Leroux JC, Atkinson BL, Binette F, Selmani A (2000) Novel injectable neutral solutions of chitosan form biodegradable gels in situ. Biomaterials 21:2155–2161PubMedCrossRef
22.
Zurück zum Zitat Crock H, Goldwasser VM (1984) Anatomic studies of the circulation in the region of the vertebral end-plate in adult greyhound dogs. Spine 9:702–706PubMedCrossRef Crock H, Goldwasser VM (1984) Anatomic studies of the circulation in the region of the vertebral end-plate in adult greyhound dogs. Spine 9:702–706PubMedCrossRef
23.
Zurück zum Zitat Donisch E, Trapp WW (1971) The cartilage endplates of the human vertebral column (some considerations of postnatal development). Anat Rec 169:705–716PubMedCrossRef Donisch E, Trapp WW (1971) The cartilage endplates of the human vertebral column (some considerations of postnatal development). Anat Rec 169:705–716PubMedCrossRef
24.
Zurück zum Zitat Felt JC, Rydell MA, Zdrahala RJ, Arsenyev A (2001) Biomaterial for in situ tissue repair, U.S. Patent 6,306,177 Felt JC, Rydell MA, Zdrahala RJ, Arsenyev A (2001) Biomaterial for in situ tissue repair, U.S. Patent 6,306,177
25.
Zurück zum Zitat Ferrari FA, Richardson C, Chambers J, Causey S, Pollock TJ, Cappello J, Crissmann JW (2002) Peptides comprising repetitive units of amino acids and DNA sequences encoding the same, U.S. Patent 6,355,776 Ferrari FA, Richardson C, Chambers J, Causey S, Pollock TJ, Cappello J, Crissmann JW (2002) Peptides comprising repetitive units of amino acids and DNA sequences encoding the same, U.S. Patent 6,355,776
26.
Zurück zum Zitat Frymoyer JW, Hanley EN, Howe J, Kuhlmann D, Matteri RE (1979) A comparison of radiographic findings in fusion and nonfusion patients ten and more years following disc surgery. Spine 4:435–440PubMedCrossRef Frymoyer JW, Hanley EN, Howe J, Kuhlmann D, Matteri RE (1979) A comparison of radiographic findings in fusion and nonfusion patients ten and more years following disc surgery. Spine 4:435–440PubMedCrossRef
27.
Zurück zum Zitat Gotfried Y, Bradford DS, Oegena TR Jr (1986) Facet joint changes after chemonucleolysis-induced disc space narrowing. Spine 11:944–950PubMedCrossRef Gotfried Y, Bradford DS, Oegena TR Jr (1986) Facet joint changes after chemonucleolysis-induced disc space narrowing. Spine 11:944–950PubMedCrossRef
28.
Zurück zum Zitat Hassler O (1970) The human intervertebral disc: a micro-angiographical study of its vascular supply at various ages. Acta Orthop Scand 40:765–772 Hassler O (1970) The human intervertebral disc: a micro-angiographical study of its vascular supply at various ages. Acta Orthop Scand 40:765–772
29.
Zurück zum Zitat Hermantin FU, Peters T, Quartararo L, Kambin P (1999) A prospective, randomized study comparing the results of open discectomy with those of video-assisted arthroscopic microdiscectomy. J Bone Jt Surg 81-A:958–965 Hermantin FU, Peters T, Quartararo L, Kambin P (1999) A prospective, randomized study comparing the results of open discectomy with those of video-assisted arthroscopic microdiscectomy. J Bone Jt Surg 81-A:958–965
30.
Zurück zum Zitat Hubbell JA, Pathak CP, Sawhney AS, Desai NP, Hill JL (1997) Photopolymerizable biodegradable hydrogels as tissue contacting materials and controlled-release microcarriers, U.S. Patent 5,626,863 Hubbell JA, Pathak CP, Sawhney AS, Desai NP, Hill JL (1997) Photopolymerizable biodegradable hydrogels as tissue contacting materials and controlled-release microcarriers, U.S. Patent 5,626,863
31.
Zurück zum Zitat Hubbell JA, Wetering Pvd, Cowling DSP (2002) Novel polymer compounds, Patent 2002/0177680 Hubbell JA, Wetering Pvd, Cowling DSP (2002) Novel polymer compounds, Patent 2002/0177680
32.
Zurück zum Zitat Iatridis JC, Mente PL, Stokes IAF, Aronsson DD, Alini M (1999) Compression -induced changes in intervertebral disc properties in a rat tail model. Spine 24:996–1002PubMedCrossRef Iatridis JC, Mente PL, Stokes IAF, Aronsson DD, Alini M (1999) Compression -induced changes in intervertebral disc properties in a rat tail model. Spine 24:996–1002PubMedCrossRef
33.
Zurück zum Zitat Iatridis JC, Weidenbaum M, Setton LA, Mow VC (1996) Is the nucleus pulposus a solid or fluid? Mechanical behavior of the nucleus pulposus of the human intervertebral disc. Spine 21:1174–1184PubMedCrossRef Iatridis JC, Weidenbaum M, Setton LA, Mow VC (1996) Is the nucleus pulposus a solid or fluid? Mechanical behavior of the nucleus pulposus of the human intervertebral disc. Spine 21:1174–1184PubMedCrossRef
34.
Zurück zum Zitat Kitano T, Zerwekh J, Usui Y, Edwards M, Flickere P, Mooney V (1993) Biochemical changes associated with the symptomatic human intervertebral disc. Clin Orthop Rel Res 293:372–377 Kitano T, Zerwekh J, Usui Y, Edwards M, Flickere P, Mooney V (1993) Biochemical changes associated with the symptomatic human intervertebral disc. Clin Orthop Rel Res 293:372–377
35.
Zurück zum Zitat Kokkonen SM, Kurunlahti M, Tervonen O, Iikko E, Vanharanta H (2002) Endplate degeneration observed on magnetic resonance imaging of the lumbar spine: correlation with pain provocation and disc changes observed on computed tomography diskography. Spine 27:2274–2278PubMedCrossRef Kokkonen SM, Kurunlahti M, Tervonen O, Iikko E, Vanharanta H (2002) Endplate degeneration observed on magnetic resonance imaging of the lumbar spine: correlation with pain provocation and disc changes observed on computed tomography diskography. Spine 27:2274–2278PubMedCrossRef
36.
Zurück zum Zitat Lotz JC, Colliou OK, Chin JR, Duncan NA, Liebenberg E (1998) Compression-induced degeneration of the intervertebral disc: an in vivo mouse model and finite-element study. Spine 23:2493–2506PubMedCrossRef Lotz JC, Colliou OK, Chin JR, Duncan NA, Liebenberg E (1998) Compression-induced degeneration of the intervertebral disc: an in vivo mouse model and finite-element study. Spine 23:2493–2506PubMedCrossRef
37.
Zurück zum Zitat Mahar AT, Oka R, Whitledge J, Cappello JR, Powell J, McArthur T (2002) Biomechanical efficacy of a protein polymer hydrogel for inter-vertebral nucleus augmentation and replacement. World Congress on Biomechanics, Calgary, Canada, p 356 Mahar AT, Oka R, Whitledge J, Cappello JR, Powell J, McArthur T (2002) Biomechanical efficacy of a protein polymer hydrogel for inter-vertebral nucleus augmentation and replacement. World Congress on Biomechanics, Calgary, Canada, p 356
38.
Zurück zum Zitat Maroudas A, Stockwell RA, Nachemson A, Urban J (1975) Factors involved in the nutrition of the human lumbar intervertebral disc: cellularity and diffusion of glucose in vitro. J Anat 120:113–130PubMed Maroudas A, Stockwell RA, Nachemson A, Urban J (1975) Factors involved in the nutrition of the human lumbar intervertebral disc: cellularity and diffusion of glucose in vitro. J Anat 120:113–130PubMed
39.
Zurück zum Zitat Milner R, Arrowsmith P, Millan EJ (2001) Intervertebral disc implant, U.S. Patent 6,187,048 Milner R, Arrowsmith P, Millan EJ (2001) Intervertebral disc implant, U.S. Patent 6,187,048
40.
Zurück zum Zitat Mochida J, Toh E, Nomura T, Nishimura K (2001) The risks and benefits of percutaneous nucleotomy for lumbar disc herniation: a ten-year longitudinal study. J Bone Jt Surg 83-B:501–505CrossRef Mochida J, Toh E, Nomura T, Nishimura K (2001) The risks and benefits of percutaneous nucleotomy for lumbar disc herniation: a ten-year longitudinal study. J Bone Jt Surg 83-B:501–505CrossRef
41.
Zurück zum Zitat Modic MT, Steinberg PM, Ross JS, Masaryk TJ, Carter JR (1988) Degenerative disc disease: assessment of changes in vertebral body marrow with mr imaging. Radiology 166:193–199PubMed Modic MT, Steinberg PM, Ross JS, Masaryk TJ, Carter JR (1988) Degenerative disc disease: assessment of changes in vertebral body marrow with mr imaging. Radiology 166:193–199PubMed
42.
Zurück zum Zitat Nachemson A (1962) Some mechanical properties of the lumbar intervertebral disc. Bull Hosp Joint Dis 23:130–132PubMed Nachemson A (1962) Some mechanical properties of the lumbar intervertebral disc. Bull Hosp Joint Dis 23:130–132PubMed
43.
Zurück zum Zitat Nachemson A, Lewin T, Maroudas A, Freeman MAR (1970) In vitro diffusion of dye through the end-plates and the annulus fibrosus of human lumbar inter-vertebral discs. Acta Orthop Scand 41:589–607PubMedCrossRef Nachemson A, Lewin T, Maroudas A, Freeman MAR (1970) In vitro diffusion of dye through the end-plates and the annulus fibrosus of human lumbar inter-vertebral discs. Acta Orthop Scand 41:589–607PubMedCrossRef
44.
Zurück zum Zitat Natarajan RN, Ke JH, Andersson GBJ (1994) A model to study the disc degeneration process. Spine 19:259–265PubMedCrossRef Natarajan RN, Ke JH, Andersson GBJ (1994) A model to study the disc degeneration process. Spine 19:259–265PubMedCrossRef
45.
Zurück zum Zitat Nishida K, Gilbertson LG, Evans CH, Kang JD (2000) Spine update: Potential applications of gene therapy to the treatment of spinal disorders. Spine 25:1308–1314PubMedCrossRef Nishida K, Gilbertson LG, Evans CH, Kang JD (2000) Spine update: Potential applications of gene therapy to the treatment of spinal disorders. Spine 25:1308–1314PubMedCrossRef
46.
Zurück zum Zitat Ohshima H, Urban JPG, Bergel DH (1995) Effect of static load on matrix synthesis rates in the intervertebral disc measured in vitro by a new perfusion technique. J Orthop Res 13:22–29PubMedCrossRef Ohshima H, Urban JPG, Bergel DH (1995) Effect of static load on matrix synthesis rates in the intervertebral disc measured in vitro by a new perfusion technique. J Orthop Res 13:22–29PubMedCrossRef
47.
Zurück zum Zitat Oki S, Matsuda Y, Shibata T, Okumura H, Desaki J (1996) Morphologic differences of the vascular buds in the vertebral endplate: scanning electron microscipic study. Spine 21:174–177PubMedCrossRef Oki S, Matsuda Y, Shibata T, Okumura H, Desaki J (1996) Morphologic differences of the vascular buds in the vertebral endplate: scanning electron microscipic study. Spine 21:174–177PubMedCrossRef
48.
Zurück zum Zitat Paajanen H, Lehto I, Alanen A, Erkintalo M, Komu M (1994) Diurnal fluid changes of lumbar discs measured indirectly by magnetic resonance imaging. J Orthop Res 12:509–514PubMedCrossRef Paajanen H, Lehto I, Alanen A, Erkintalo M, Komu M (1994) Diurnal fluid changes of lumbar discs measured indirectly by magnetic resonance imaging. J Orthop Res 12:509–514PubMedCrossRef
49.
Zurück zum Zitat Panjabi MM, Krag MH, Chung TQ (1984) Effects of disc injury on mechanical behavior of the human spine. Spine 9:707–713PubMedCrossRef Panjabi MM, Krag MH, Chung TQ (1984) Effects of disc injury on mechanical behavior of the human spine. Spine 9:707–713PubMedCrossRef
50.
Zurück zum Zitat Pritzker KPH (1977) Aging and degeneration in the lumbar intervertebral disc. Orthop Clin North Am 8:65–77 Pritzker KPH (1977) Aging and degeneration in the lumbar intervertebral disc. Orthop Clin North Am 8:65–77
51.
Zurück zum Zitat Quinn T, Hunziker B (2002) Controlled enzymatic matrix degradation for integrative cartilage repair: effects on viable cell density and proteoglycan deposition. Tissue Eng. 8:799–806PubMedCrossRef Quinn T, Hunziker B (2002) Controlled enzymatic matrix degradation for integrative cartilage repair: effects on viable cell density and proteoglycan deposition. Tissue Eng. 8:799–806PubMedCrossRef
52.
Zurück zum Zitat Rhee WM, DeLustro FA, Berg RA (2001) Method of making crosslinked polymer matrices in tissue treatment applications, U.S. Patent 6,323,278 Rhee WM, DeLustro FA, Berg RA (2001) Method of making crosslinked polymer matrices in tissue treatment applications, U.S. Patent 6,323,278
53.
Zurück zum Zitat Schneider P, Oyen GR (1974a) Intervertebral disc replacement, experimental studies, clinical consequences. Z Orthop Ihre Grenzgeb 112:791–792 Schneider P, Oyen GR (1974a) Intervertebral disc replacement, experimental studies, clinical consequences. Z Orthop Ihre Grenzgeb 112:791–792
54.
Zurück zum Zitat Schneider P, Oyen GR (1974b) Plastic surgery on intervertebral disc: Part i intervertebral disc replacement in the lumbar regions with silicone rubber. Theoretical and experimental studies. Z Orthop Ihre Grenzgeb 112:1078–1086 Schneider P, Oyen GR (1974b) Plastic surgery on intervertebral disc: Part i intervertebral disc replacement in the lumbar regions with silicone rubber. Theoretical and experimental studies. Z Orthop Ihre Grenzgeb 112:1078–1086
55.
Zurück zum Zitat Scoville W, Corkill BG (1973) Lumbar disc surgery: technique of radical removal and early mobilization. J Neurosurg 39:265–269PubMedCrossRef Scoville W, Corkill BG (1973) Lumbar disc surgery: technique of radical removal and early mobilization. J Neurosurg 39:265–269PubMedCrossRef
56.
Zurück zum Zitat Stedronsky E, Cappello RJ (2002) Sealing or filling tissue defects using polyfunctional crosslinking agents and protein polymers, U.S. Patent 6,423,333 Stedronsky E, Cappello RJ (2002) Sealing or filling tissue defects using polyfunctional crosslinking agents and protein polymers, U.S. Patent 6,423,333
57.
Zurück zum Zitat Tibrewal SB, Pearcy MJ (1985) Lumbar intervertebral disc heights in normal subjects and patients with disc herniation. Spine 10:452–454PubMedCrossRef Tibrewal SB, Pearcy MJ (1985) Lumbar intervertebral disc heights in normal subjects and patients with disc herniation. Spine 10:452–454PubMedCrossRef
58.
Zurück zum Zitat Urban JPG, Holm S, Maroudas A (1978) Diffusion of small solutes into the intervertebral disc: an in vivo study. Biorheology 15:203–223PubMed Urban JPG, Holm S, Maroudas A (1978) Diffusion of small solutes into the intervertebral disc: an in vivo study. Biorheology 15:203–223PubMed
59.
Zurück zum Zitat Urban JP, Maroudas GA (1979) The measurement of fixed charge density in the intervertebral disc. Biochim Biophys Acta 586:166–178 Urban JP, Maroudas GA (1979) The measurement of fixed charge density in the intervertebral disc. Biochim Biophys Acta 586:166–178
60.
Zurück zum Zitat Urban JPG, Smith S, Fairbank JCT (2004) Nutrition of the intervertebral disc. Spine 29:2700–2709PubMedCrossRef Urban JPG, Smith S, Fairbank JCT (2004) Nutrition of the intervertebral disc. Spine 29:2700–2709PubMedCrossRef
61.
Zurück zum Zitat Urry DW (1991) Polynanopeptide bioelastomers having an increased elastic modulus, U.S. Patent 5,064,430 Urry DW (1991) Polynanopeptide bioelastomers having an increased elastic modulus, U.S. Patent 5,064,430
62.
Zurück zum Zitat Vernon-Roberts BC, Pirie J (1973) Healing trabecular microfractures in the bodies of lumbar vertebrae. Ann Rheum Dis. 32:406–412PubMedCrossRef Vernon-Roberts BC, Pirie J (1973) Healing trabecular microfractures in the bodies of lumbar vertebrae. Ann Rheum Dis. 32:406–412PubMedCrossRef
63.
Zurück zum Zitat Walkenhorst J, Kitchel S, Spenciner D (2004) Effect of injectable disc nucleus on function of human cadaver spine. In: 11th International meeting on advanced spine techniques (IMAST) Bermuda Walkenhorst J, Kitchel S, Spenciner D (2004) Effect of injectable disc nucleus on function of human cadaver spine. In: 11th International meeting on advanced spine techniques (IMAST) Bermuda
64.
Zurück zum Zitat Wallace AL, Wyatt BC, McCarthy ID, Hughes SPF (1994) Humoral regulation of blood flow in the vertebral endplates. Spine 19:1324–1328PubMedCrossRef Wallace AL, Wyatt BC, McCarthy ID, Hughes SPF (1994) Humoral regulation of blood flow in the vertebral endplates. Spine 19:1324–1328PubMedCrossRef
65.
Zurück zum Zitat Whalen JL, Parke WW, Mazur JM, Stauffer ES (1985) The intrinsic vasculature of developing vertebral end plates and its nutritive significance to the intervertebral discs. J Pediatric Orthop 5:403–410 Whalen JL, Parke WW, Mazur JM, Stauffer ES (1985) The intrinsic vasculature of developing vertebral end plates and its nutritive significance to the intervertebral discs. J Pediatric Orthop 5:403–410
66.
Zurück zum Zitat Yoon ST (2004) The potential for gene therapy for the treatment of disc degeneration. Orthop Clin North Am 35:95–100PubMedCrossRef Yoon ST (2004) The potential for gene therapy for the treatment of disc degeneration. Orthop Clin North Am 35:95–100PubMedCrossRef
67.
Zurück zum Zitat Yorimitsu E, Chiba K, Toyama Y, Hirabayashi K (2001) Long-term outcomes of standard discectomy for lumbar disc herniation: a follow-up study of more than 10 years. Spine 26:652–657PubMedCrossRef Yorimitsu E, Chiba K, Toyama Y, Hirabayashi K (2001) Long-term outcomes of standard discectomy for lumbar disc herniation: a follow-up study of more than 10 years. Spine 26:652–657PubMedCrossRef
68.
Zurück zum Zitat Yuksel KU, Walsh SP, Black KS (2005) In situ bioprosthetic filler and methods, particularily for the in situ formation of vertebral disc bioprosthetics, U.S. Patent 6,921,412 Yuksel KU, Walsh SP, Black KS (2005) In situ bioprosthetic filler and methods, particularily for the in situ formation of vertebral disc bioprosthetics, U.S. Patent 6,921,412
Metadaten
Titel
Injectable biomaterials and vertebral endplate treatment for repair and regeneration of the intervertebral disc
verfasst von
Lawrence M. Boyd
Andrew J. Carter
Publikationsdatum
01.08.2006
Verlag
Springer-Verlag
Erschienen in
European Spine Journal / Ausgabe Sonderheft 3/2006
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-006-0172-2

Weitere Artikel der Sonderheft 3/2006

European Spine Journal 3/2006 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.