Objective

The Isocentric C-arm 3D navigation has been widely used in superior cervical surgeries in recent years. Several clinical researches reported that navigation system was an effective support device for treatment of atlantoaxial instability. But there were few studies about the advantages of navigation system compared to conventional C-arm fluoroscopy in C1–C2 transarticular screw fixation for atlantoaxial instability. The aim of the study was to evaluate the precision of computer-assisted C1–C2 transarticular screw fixation (Magerl’s technique) for atlantoaxial instability and compare the clinical results with conventional C-arm fluoroscopy.

Methods

Forty-two patients diagnosed as atlantoaxial instability who underwent C1–C2 transarticular screw fixation under two different fluoroscopy methods were studied. The Iso-C 3D navigation group included 18 patients and the other 24 patients were in the conventional C-arm group. The clinical and radiographic results were recorded and compared between the two groups. Patients were followed up with clinical examination and radiographs at a mean of 18.4 months.

Results

There were no significant differences between two groups in the mean age, gender, and causes of atlantoaxial instability. The mean blood loss in the navigation group was 236.1 ± 28.5 mL versus 308.3 ± 21.2 mL in the conventional C-arm group. The radiation time was significantly reduced using 3D navigation (48.8 ± 1.05 s versus 60.3 ± 2.23 s). Overall, 97.2 % (35/36) of 3D navigated screws and 91.7 % (44/48) of fluoroscopy screws were placed into the C1–C2 transarticular passages. Thirty-nine of forty patients showed evidence of solid fusion after 12 months on cervical plain radiographies or CT scans.

Conclusions

On comparing the two imaging techniques, it was found that using Iso-C 3D navigation can improve accuracy of the C1–C2 transarticular screws, decrease intra-operative fluoroscopic time and blood loss, and not prolong the operative time. This study demonstrates that Iso-C 3D navigation is a safe and effective means of guiding C1–C2 transarticular screw fixation for atlantoaxial instability.
Literatur
1.
Zurück zum Zitat Briem D, Linhart W, Lehmann W, Begemann PG, Adam G, Schumacher U et al (2006) Computer-assisted screw insertion into the first sacral vertebra using a three-dimensional image intensifier: results of a controlled experimental investigation. Eur Spine J 15:757–763PubMedCentralPubMedCrossRef Briem D, Linhart W, Lehmann W, Begemann PG, Adam G, Schumacher U et al (2006) Computer-assisted screw insertion into the first sacral vertebra using a three-dimensional image intensifier: results of a controlled experimental investigation. Eur Spine J 15:757–763PubMedCentralPubMedCrossRef
2.
Zurück zum Zitat Citak M, Kendoff D, Kfuri M Jr, Pearle A, Krettek C, Hufner T (2007) Accuracy analysis of Iso-C3D versus fluoroscopy-based navigated retrograde drilling of osteochondral lesions: a pilot study. J Bone Joint Surg Br 89:323–326PubMedCrossRef Citak M, Kendoff D, Kfuri M Jr, Pearle A, Krettek C, Hufner T (2007) Accuracy analysis of Iso-C3D versus fluoroscopy-based navigated retrograde drilling of osteochondral lesions: a pilot study. J Bone Joint Surg Br 89:323–326PubMedCrossRef
3.
Zurück zum Zitat Dickman CA, Sonntag VK (1998) Posterior C1–C2 transarticular screw fixation for atlantoaxial arthrodesis. Neurosurgery 43:275–280 (discussion 280–271) PubMedCrossRef Dickman CA, Sonntag VK (1998) Posterior C1–C2 transarticular screw fixation for atlantoaxial arthrodesis. Neurosurgery 43:275–280 (discussion 280–271) PubMedCrossRef
4.
Zurück zum Zitat Gebhard FT, Kraus MD, Schneider E, Liener UC, Kinzl L, Arand M (2006) Does computer-assisted spine surgery reduce intraoperative radiation doses? Spine 31:2024–2027 (discussion 2028) PubMedCrossRef Gebhard FT, Kraus MD, Schneider E, Liener UC, Kinzl L, Arand M (2006) Does computer-assisted spine surgery reduce intraoperative radiation doses? Spine 31:2024–2027 (discussion 2028) PubMedCrossRef
5.
Zurück zum Zitat Gluf WM, Schmidt MH, Apfelbaum RI (2005) Atlantoaxial transarticular screw fixation: a review of surgical indications, fusion rate, complications, and lessons learned in 191 adult patients. J Neurosurg Spine 2:155–163PubMedCrossRef Gluf WM, Schmidt MH, Apfelbaum RI (2005) Atlantoaxial transarticular screw fixation: a review of surgical indications, fusion rate, complications, and lessons learned in 191 adult patients. J Neurosurg Spine 2:155–163PubMedCrossRef
6.
Zurück zum Zitat Haid RW Jr, Subach BR, McLaughlin MR, Rodts GE Jr, Wahlig JB Jr (2001) C1–C2 transarticular screw fixation for atlantoaxial instability: a 6 year experience. Neurosurgery 49:65–68 (discussion 69–70) PubMed Haid RW Jr, Subach BR, McLaughlin MR, Rodts GE Jr, Wahlig JB Jr (2001) C1–C2 transarticular screw fixation for atlantoaxial instability: a 6 year experience. Neurosurgery 49:65–68 (discussion 69–70) PubMed
7.
Zurück zum Zitat Kazan S, Yildirim F, Sindel M, Tuncer R (2000) Anatomical evaluation of the groove for the vertebral artery in the axis vertebrae for atlanto-axial transarticular screw fixation technique. Clin Anat 13:237–243PubMedCrossRef Kazan S, Yildirim F, Sindel M, Tuncer R (2000) Anatomical evaluation of the groove for the vertebral artery in the axis vertebrae for atlanto-axial transarticular screw fixation technique. Clin Anat 13:237–243PubMedCrossRef
8.
Zurück zum Zitat Madawi AA, Casey AT, Solanki GA, Tuite G, Veres R, Crockard HA (1997) Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg 86:961–968PubMedCrossRef Madawi AA, Casey AT, Solanki GA, Tuite G, Veres R, Crockard HA (1997) Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg 86:961–968PubMedCrossRef
9.
Zurück zum Zitat Magerl F, Seemann P-S (1987) Stable posterior fusion of the atlas and axis by transarticular screw fixation. In: Kehr P, Weidner A (eds) Cervical Spine I. Springer, Wien, pp 322–327CrossRef Magerl F, Seemann P-S (1987) Stable posterior fusion of the atlas and axis by transarticular screw fixation. In: Kehr P, Weidner A (eds) Cervical Spine I. Springer, Wien, pp 322–327CrossRef
10.
Zurück zum Zitat Martirosyan NL, Kalb S, Cavalcanti DD, Lochhead RA, Uschold TD, Loh A et al (2013) Comparative analysis of isocentric 3-dimensional C-arm fluoroscopy and biplanar fluoroscopy for anterior screw fixation in odontoid fractures. J Spinal Disord Tech 26:189–193PubMedCrossRef Martirosyan NL, Kalb S, Cavalcanti DD, Lochhead RA, Uschold TD, Loh A et al (2013) Comparative analysis of isocentric 3-dimensional C-arm fluoroscopy and biplanar fluoroscopy for anterior screw fixation in odontoid fractures. J Spinal Disord Tech 26:189–193PubMedCrossRef
11.
Zurück zum Zitat Rajasekaran S, Tubaki VR, Shetty AP (2012) Results of direct repair of type 2 hangman fracture using Iso-C3D navigation: 20 cases. J Spinal Disord Tech 25:E134–E139PubMedCrossRef Rajasekaran S, Tubaki VR, Shetty AP (2012) Results of direct repair of type 2 hangman fracture using Iso-C3D navigation: 20 cases. J Spinal Disord Tech 25:E134–E139PubMedCrossRef
12.
Zurück zum Zitat Sim HB, Lee JW, Park JT, Mindea SA, Lim J, Park J (2011) Biomechanical evaluations of various c1–c2 posterior fixation techniques. Spine 36:E401–E407PubMedCrossRef Sim HB, Lee JW, Park JT, Mindea SA, Lim J, Park J (2011) Biomechanical evaluations of various c1–c2 posterior fixation techniques. Spine 36:E401–E407PubMedCrossRef
13.
Zurück zum Zitat Smith HE, Welsch MD, Sasso RC, Vaccaro AR (2008) Comparison of radiation exposure in lumbar pedicle screw placement with fluoroscopy vs computer-assisted image guidance with intraoperative three-dimensional imaging. J Spinal Cord Med 31:532–537PubMedCentralPubMed Smith HE, Welsch MD, Sasso RC, Vaccaro AR (2008) Comparison of radiation exposure in lumbar pedicle screw placement with fluoroscopy vs computer-assisted image guidance with intraoperative three-dimensional imaging. J Spinal Cord Med 31:532–537PubMedCentralPubMed
14.
Zurück zum Zitat Suchomel P, Stulik J, Klezl Z, Chrobok J, Lukas R, Krbec M et al (2004) Transarticular fixation of C1-C2: a multicenter retrospective study. Acta Chir Orthop Traumatol Cech 71:6–12PubMed Suchomel P, Stulik J, Klezl Z, Chrobok J, Lukas R, Krbec M et al (2004) Transarticular fixation of C1-C2: a multicenter retrospective study. Acta Chir Orthop Traumatol Cech 71:6–12PubMed
15.
Zurück zum Zitat Summers LE, Kouri JG, Yang M, Patrick Jacob R (2008) Odontoid screw placement using Isocentric 3-dimensional C-arm fluoroscopy. J Spinal Disord Tech 21:45–48PubMedCrossRef Summers LE, Kouri JG, Yang M, Patrick Jacob R (2008) Odontoid screw placement using Isocentric 3-dimensional C-arm fluoroscopy. J Spinal Disord Tech 21:45–48PubMedCrossRef
16.
Zurück zum Zitat Uehara M, Takahashi J, Hirabayashi H, Hashidate H, Ogihara N, Mukaiyama K et al (2012) Computer-assisted C1–C2 transarticular screw fixation “magerl technique” for atlantoaxial instability. Asian Spine J 6:168–177PubMedCentralPubMedCrossRef Uehara M, Takahashi J, Hirabayashi H, Hashidate H, Ogihara N, Mukaiyama K et al (2012) Computer-assisted C1–C2 transarticular screw fixation “magerl technique” for atlantoaxial instability. Asian Spine J 6:168–177PubMedCentralPubMedCrossRef
17.
Zurück zum Zitat Yang YL, Fu BS, Li RW, Smith PN, Mu WD, Li LX et al (2011) Anterior single screw fixation of odontoid fracture with intraoperative Iso-C 3-dimensional imaging. Eur Spine J 20:1899–1907PubMedCentralPubMedCrossRef Yang YL, Fu BS, Li RW, Smith PN, Mu WD, Li LX et al (2011) Anterior single screw fixation of odontoid fracture with intraoperative Iso-C 3-dimensional imaging. Eur Spine J 20:1899–1907PubMedCentralPubMedCrossRef
18.
Zurück zum Zitat Wright NM, Lauryssen C (1998) Vertebral artery injury in C1–2 transarticular screw fixation: results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves. American Association of Neurological Surgeons/Congress of Neurological Surgeons. J Neurosurg 88:634–640PubMedCrossRef Wright NM, Lauryssen C (1998) Vertebral artery injury in C1–2 transarticular screw fixation: results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves. American Association of Neurological Surgeons/Congress of Neurological Surgeons. J Neurosurg 88:634–640PubMedCrossRef
19.
Zurück zum Zitat Weng C, Tian W, Li ZY, Liu B, Li Q, Wang YQ et al (2012) Surgical management of symptomatic os odontoideum with posterior screw fixation performed using the magerl and harms techniques with intraoperative 3-dimensional fluoroscopy-based navigation. Spine 37:1839–1846PubMedCrossRef Weng C, Tian W, Li ZY, Liu B, Li Q, Wang YQ et al (2012) Surgical management of symptomatic os odontoideum with posterior screw fixation performed using the magerl and harms techniques with intraoperative 3-dimensional fluoroscopy-based navigation. Spine 37:1839–1846PubMedCrossRef
20.
Zurück zum Zitat Yang YL, Zhou DS, He JL (2013) Comparison of isocentric C-arm 3-dimensional navigation and conventional fluoroscopy for C1 lateral mass and C2 pedicle screw placement for atlantoaxial instability. J Spinal Disord Tech 26:127–134PubMedCrossRef Yang YL, Zhou DS, He JL (2013) Comparison of isocentric C-arm 3-dimensional navigation and conventional fluoroscopy for C1 lateral mass and C2 pedicle screw placement for atlantoaxial instability. J Spinal Disord Tech 26:127–134PubMedCrossRef
Metadaten
Titel
Isocentric C-arm three-dimensional navigation versus conventional C-arm assisted C1–C2 transarticular screw fixation for atlantoaxial instability
verfasst von
Yongliang Yang
Fu Wang
Shumei Han
Yonghui Wang
Jinlei Dong
Lianxin Li
Dongsheng Zhou
Publikationsdatum
01.08.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 8/2015
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-015-2249-z

Weitere Artikel der Ausgabe 8/2015

Archives of Orthopaedic and Trauma Surgery 8/2015 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.