Background
The diagnosis of prostate cancer (PCa) is currently made by histological confirmation from a prostate biopsy guided by altered serum prostate-specific antigen (PSA) values (≥ 4 ng/ml) and/or a suspicious digital rectal examination (DRE) [
1‐
3]. However, this approach presents many limitations including low specificity of PSA and DRE and the molecular heterogeneity of PCa that at the end determines tumour behavior [
4]. For this reason, there is an urgent need in developing more targeted and non-invasive diagnostic tools, based on the molecular characterization of body fluids, that provide information about the malignant potential of PCa and allowing the monitoring of the disease into the different clinical scenarios.
Urine, due to the anatomic proximity of the prostate gland to the urethra, constitutes a valuable source of PCa biomarkers particularly derived from exfoliated prostatic cells, excreted proteins, circulating nucleic acids or extracellular vesicles (EVs) [
5]. EVs are small membrane vesicles that are classified according to their size, cellular origin and biogenesis into microvesicles, exosomes, and apoptotic bodies [
6,
7]. They are released by most cell types in physiological and pathological conditions [
7] and can be isolated from all body fluids (including urine, blood, saliva, milk, semen, cerebrospinal fluid, etc.) [
8,
9]. EVs contains a variety of molecules including nucleic acids, proteins, lipids, and some other metabolites [
10‐
12], and their composition is affected by different environmental factors and health status [
13,
14]. Given their ability to horizontally transfer genetic material and signaling moieties between different cells in the organism, EVs have recently emerged as powerful mediators of cell–cell communication [
7].
Currently, EVs-cargo represents a doubtless source of biomarkers that may represent the different PCa progression stages [
15,
16] and constitute promising tools for the development of minimally invasive diagnostic approaches. Hence, because of their increasing potential for their use in clinical scenarios, it has become vitally important to improve the isolation methods for maximum purity, yield, and assay reproducibility [
17]. The most common approaches for EVs isolation include size exclusion chromatography (SEC); classical ultracentrifugation (UC) [
17]; sucrose density-gradient centrifugation; affinity chromatography using antibodies against EVs markers (such as CD9, CD81, CD63) [
18]; or commercial kits [
8,
19‐
21]. Despite their importance, EVs isolation and characterization are still considered major scientific challenges [
22,
23], and identifying the best techniques for their isolation is crucial for further biomarker discoveries.
The aim of this study was to compare three different EVs isolation methods: UC, SEC, and a commercial kit (Exolute® Urine Kit) using urine from a series of PCa patients and healthy donors (HDs). The outperformance of the three methods was evaluated by using different analytic approaches, including NanoDrop protein quantification, nanoparticle tracking analysis (NTA), transmission electron microscopy (TEM), AlphaScreen Technology, and HTG EdgeSeq miRNA Whole Transcriptome Assay (miRNA WTA).
Methods
Sample collection and ethical considerations
Urine samples from six PCa patients and four HDs (men with no history of cancer or other prior chronical diseases), were retrieved from the archives of the Biobank of the Fundación Instituto Valenciano de Oncología (FIVO). Written informed consent for sample donation for research purposes was obtained from all patients prior to sample collection, and the study was approved by the Clinical Research Ethics Committee (CREC) and the Institutional Ethics Committee (Ref. PROMETEO 2016/103), at the meeting held on May 28, 2015. All methods used during the study were performed in accordance with the relevant guidelines and regulations.
Urine processing
A median of 72 mL (range: 54–90 mL) of urine were collected in sterile urine containers (Ref. 409726 Deltalab, Barcelona, Spain). Protease Inhibitor Cocktail (P8340-5 mL, Sigma Aldrich, San Luis, MO, USA) was added to preserve exosomes (50 µL cocktail in 100 mL urine sample) [
24]. Each sample was centrifuged at 1000×
g, 10 min at 4 °C, and supernatant were frozen at − 80 °C until use. The pre-analytical variables of the samples with SPREC code [
25‐
27] are shown in Table
1.
Table 1
Preanalytical variables included in the Standard PREanalytical Code (SPREC), applied to urine samples
127 | PCa patient | URN-PIX-D-D-N-N-J |
129 | PCa patient | URN-PIX-D-D-N-N-J |
132 | PCa patient | URN-PIX-A-D-N-N-J |
144 | PCa patient | URN-PIX-B-D-N-N-J |
146 | PCa patient | URN-PIX-B-D-N-N-J |
148 | PCa patient | URN-PIX-B-D-N-N-J |
161 | HDs | URN-PIX-A-D-N-N-J |
163 | HDs | URN-PIX-A-D-N-N-J |
164 | HDs | URN-PIX-A-D-N-N-J |
167 | HDs | URN-PIX-A-D-N-N-J |
Briefly, urine samples were thawed at 4 °C before use. Samples were centrifuged at 1000×
g, 15 min at room temperature (RT) to remove cell debris, and the collected supernatants were then centrifuged at 3000×
g, 15 min at 4 °C. The major urinary contaminant, mucoprotein (the Tamm-Horsfall protein), was removed by adding NaCl to a final concentration of 0.58 M and incubated for 2 h at RT, as previously described [
28]. Samples were then centrifuged at 16,000×
g, for 20 min at 4 °C, and the supernatant was collected and filtered through 0.22 µm membrane filters (Thermo Fisher Scientific, Waltham, MA, USA). Finally, the total volume of urine from each sample was divided into 3 equal parts, to perform the 3 different EVs isolation methods.
Isolation methods
EVs enrichment by ultracentrifugation (UC) Urine supernatants were centrifuged at 100,000× g, 2 h at 4 °C (in a 50.2 Ti Titanium rotor, Beckman coulter, using a CP100NX ultracentrifuge, Hitachi). The 100,000× g pellet was resuspended in 150 µL of filtered Phosphate-Buffered Saline (PBS).
Size exclusion chromatography (SEC) EVs isolation was performed as described by Böïng et al. [
29]. Briefly, up to 12 mL of Sepharose-CL2B (Sigma-Aldrich, San Luis, MO, USA) were stacked in a 15 mL syringe (Sigma-Aldrich, San Luis, MO, USA), and washed 3 times with PBS, previously filtered through 0.22 µm membrane filters, and used as elution buffer. Samples were concentrated using Amicon® Ultra-4 Centrifugal Filter Devices (EMD Millipore, Burlington, MA, USA) by centrifugation at 3200×
g, 20 min at 4 °C. Then, up to 0.75 mL of concentrated urine was loaded into the column, and a total of 20 fractions of 0.5 mL were collected from each sample. Fractions 8 and 9 were pooled and selected for further EVs analysis.
ExoLutE® Urine Kit Urine supernatants were concentrated to a final volume of 7 mL using Amicon® Ultra-4 Centrifugal Filter Devices (EMD Millipore Burlington, Ma, USA), and then processed with ExoLutE® Urine Kit (Rosetta Exosome® Inc., Seoul, Republic of Korea) following the manufacturer’s instructions. A total of 130 µL of EVs-enriched samples were obtained.
Characterization methods
NanoDrop quantification The protein concentration in each sample was measured at 280 nm absorbance using a NanoDrop 1000 spectrophotometer (Thermo Scientific, Waltham, MA, USA).
Nanoparticle tracking analysis (NTA) Size distribution of particles was determined by NTA in a NanoSight LM10 (Malvern Instrument Ltd, Malvern, UK), using a 405 nm laser and sCMOS camera. Data were analyzed with using the NTA software version 3.3 (Dev Build 3.3.104), with Min track Length, Max Jump Distance, and Blur set to auto, and detection threshold set to 5. Camera level was set to 15, and 5 readings of 30 s at 30 frames per second were taken with manual monitoring of temperature. Samples were diluted with filtered PBS to reach the concentration (20–120 particles/frame) recommended by the manufacturer.
Transmission electron microscopy (TEM) Sample preparation was performed as already described [
30] with modifications. Briefly, 8 µL of EVs-containing samples were fixed in 2% paraformaldehyde (PFA) for 30 min, and deposited on Formvar-carbon coated EM grids for 15 min. Then, samples were washed with PBS 0, 1 M, and post-fixed with 1% Glutaraldehyde for 5 min, washed with distilled water, and then contrasted in a mixture of uranyl acetate (1%) and methyl cellulose (0.5%). Samples were analyzed with a Jeol JEM1010 TEM, operating at 80 kV. Four different samples were analyzed for each of the isolation methods, and 100 vesicles were counted in each sample. Images were recorded on a MegaView III digital camera, and EVs size was determined using the Olympus Image Analysis Software. The sample analysis was performed at the Microscopy facility of the Central Service for Experimental Research (SCSIE) from the University of Valencia.
AlphaScreen™ Technology Five µL of EVs resuspended in PBS were transferred to a 96-well white 1/2 area microplate (Perkin Elmer, Madrid, Spain). Samples were incubated overnight at 4 °C with 10 µL/well of anti-human CD9 antibody (SHI-EXO-M01-50; CosmoBio Co, Tokyo, Japan) conjugated to AlphaLisa acceptor beads (10 µg/mL; 6,772,001, Perkin Elmer, Madrid, Spain), and 10 µL/well of biotinylated human anti-CD63 antibody (3 nM, SHI-EXO-M02-50, CosmoBio Co, Tokyo, Japan) previously biotinylated. Then, 25 µL/well of AlphaScreenTM streptavidin-coated donor beads (40 µg/mL; 6,760,002, Perkin Elmer, Madrid, Spain) were added and incubated in the dark for another 30 min at RT. A signal appears (excitation spectra at 680 nm, emission spectra at 615 nm) if the distance between both beads is less than 200 nm (compatible with exosomes size and other small EVs) thanks to the reactivity of O2, and is detected using a Multifunctional microplate reader CLARIOstar® (BMG LABTECH, Ortenberg, Germany). Assays were carried out at Centro de Investigación Principe Felipe (CIPF), Valencia, Spain.
HTG EdgeSeq miRNA Whole Transcriptome Assay (miRNA WTA) Whole miRNA transcriptome expression analysis was performed with urine derived EVs of PCa patients and HDs using the HTG EdgeSeq System (HTG Molecular Diagnostics, Inc., Tucson, AZ, USA) with the HTG EdgeSeq miRNA Whole Transcriptome Assay (miRNA WTA). This assay quantified the expression of 2083 human RNA transcripts (
https://www.htgmolecular.com/assays/mirna-wta).
The same amount of EVs (3,6 × 109) from each patient were digested with proteinase K following the manufacturer’s instructions. miRNAs of interest were then selected by a protection nuclease assay (qNPA) in the HTG EdgeSeq processor using miRNA Whole Transcriptome Assay (miRNA WTA) panel (HTG Molecular Diagnostics, Inc., Tucson, AZ, USA). Library prepared with the miRNA selected was amplified by PCR using adapters for NextSeq 550 System sequencer (Illumina, San Diego, CA, USA). Samples were purified using Agencourt AMPure XP beads kit (Beckman Coulter, Brea, CA, USA), and then quantified by ABI 7500 Fast Real-Time PCR System (qPCR) using KAPA Library Quant Kit Universal qPCR Mix (KAPA Biosystems, Wilmington, MA, USA). For the qPCR, six standards were used in triplicate. Negative controls for PCR and qPCR were also used. After library quantification, all samples were normalized to a concentration of 20 pM. Library sequencing was performed using Next Generation Sequencing (NGS) in a NextSeq 550 System, High Output, 75 cycle v2.5 (Illumina, San Diego, CA, USA). Sequenced data were processed in HTG Parser Software using Bowtie2 for sequenced reads alignment.
Statistical analysis
Kruskal–Wallis non-parametric test and U- Mann Whitney test for post-hoc pairwise comparisons were used to perform a statistical analysis of the different characterization methods. All statistical inference was performed with two-tailed tests with a significance level of 5%.
Additionally, in the processing of HTG EdgeSeq data, Principal Component Analysis was used for data visualization and DESeq2 method for the study of differentially expressed miRNAs. The IBM SPSS Statistics V22.0 package (SPSS, Chicago, IL), R v. 4.0.1 and GraphPad Prism 7 (GraphPad Software Inc.) were used for statistical analysis [
31].
Discussion
EVs have been postulated as a valuable source of potential biomarkers in PCa that at some point would complement or replace the routine diagnostic procedures [
15,
35]. Urinary EVs take special relevance since their cargo reflect changes in the cellular biology of the tumour during progression and can be isolated by non-invasive procedures. However, translation of these biomarkers into the clinical setting is not exempt of limitations, including the irreproducibility of results as one of the most important [
36]. In this regard, EVs isolation and characterization approaches still constitute a scientific challenge [
23]. Hence, with the aim of deepening in the knowledge of EVs isolation methods, we evaluated three different methodologies including the classical UC and SEC, as well as a commercial eVs isolation kit (Exolute®). EVs characterization was performed using NTA, TEM, spectrophotometry (Nanodrop), AlphaScreen™ Technology and whole miRNA transcriptome expression analysis with the EdgeSeq System (HTG Molecular Diagnostics). For this purpose, a series of urines collected from 10 individuals (6 PCa patients and 4 HDs) were analysed with each isolation method.
Absorbance measurements showed similar protein concentrations in UC and SEC; however, a significant increase was noticed in Exolute® samples (Additional file
1: Figure S1A). This effect can be explained by TEM analysis, in which preparations from EVs obtained with Exolute® showed a background of precipitated proteins (Fig.
2A) consistent with the presence of protein aggregates, as it has been previously described [
37]. NTA evaluation showed that UC provided the highest number of particles per mL and particles per µg protein ratio, in comparison with SEC and Exolute®, suggesting a higher EV yield obtained by this technique (Fig.
1A,
C). Besides that, a significant increase in size of particles obtained by SEC was noticed (~ 190 nm), when compared to the other EVs isolation procedures (~ 165 nm) (Fig.
1B). However, no differences in size were appreciated when EVs were analyzed by TEM with a median in size of around 90 nm (range: 30–200 nm). Interestingly, approximately 95% of EVs were ranged from 30 to 120 nm, and around 40% were between 60 and 90 nm of diameter (Fig.
2C). These findings correlate with previous reports showing that the size of urine EVs varies from 30 to 100 nm [
38‐
41]. Discordances between NTA and TEM herein reported may be due to different aspects including: the difficulty of NTA to resolve EVs aggregates (a correct dilution of the sample is crucial to avoid this) [
42]; the limitation of NTA in detecting particles which dimeter is lower than 100 nm [
43] and finally, the size overestimation of NTA [
44,
45]. Additionally, and as mentioned above, TEM analyses revealed high variability in EVs yield obtained by Exolute®, with some samples showing the presence of protein aggregates that would explain the highest protein content of the spectrophotometric analysis (Fig.
2A). Interestingly, SEC-isolated EVs had a broader size distribution than those isolated with Exolute® and UC, which could be due to the growing evidence that SEC minimally alters the physical properties of EVs, whereas UC might cause vesicle rupture or fusion with proteins because of the high speed used in centrifugations [
46]. No significant differences in particle concentration and size (measured by both NTA or TEM) were detected between PCa samples and HDs (Fig.
1D) which is in accordance with previous studies [
38].
Once characterized through NTA and TEM, EVs were analysed with AlphaScreen™ Technology, a strategy lately used to improve the typical immunoassays [
34] through the simultaneous detection for two specific EV-tetraspanins, CD9 and CD63 [
22,
33] and designed to specifically detect EVs lower than 200 nm. Our AlphaScreen data revealed that all three isolation methods obtained CD9 and CD63 positive EVs, as can be appreciated in Fig.
3A where luminescent signal was higher in purified EVs compared to crude urine. Furthermore, SEC provided the highest luminescent intensity followed by UC and Exolute®, which luminescent intensity was significantly lower. Interestingly, a high signal variation was noted among the analysed cases, especially in Exolute® and UC isolated EVs, for which in some cases the luminescent signal was low or null, whereas SEC isolated EVs provided a measurable signal in most of the cases (Fig.
3B). These differences would be related to those herein noticed with regards EVs size distribution, or as suggested by some reports, as consequence of differences in the membrane proteomic content of small and large EVs [
47]. Moreover, EVs rupture due to UC high-speed centrifugations [
46] or the reported variability on EVs yield depending on the equipment and operator technical variability could have affected the results [
48]. Hence, and according to the AlphaScreen™ Technology, our results highlight SEC as the most efficient method to isolate CD9 and CD63 positive microvesicles, followed by UC and Exolute®, respectively. Like the other characterization methods, no differences of luminescent signal were appreciated between EVs isolated from PCa patients and HDs for any of the isolation methods tested.
Forward characterization of EVs was carried through a whole miRNA transcriptomic analysis by using one of the newest and most reproducible RNA quantification platforms, the EdgeSeq Technology (HTG Molecular Diagnostics), currently used in many studies [
49,
50]. Among the advantages of this system are that it does not require an RNA-extraction step which, reduces the extraction-associated data bias and sample loss; and the low input of sample necessary for being analysed [
51]. Our results have shown that the sum of the normalized miRNA counts was higher in EVs isolated from SEC, followed by UC and Exolute® (Fig.
4), suggesting that the isolation methods influence on the yield of the transcriptomic analysis. Many -omic studies have been found to be highly dependent on the EVs isolation procedures, so that different methods produce EVs and EV sub-fractions of variable homogeneity, which makes difficult to extrapolate findings between different studies of EVs [
7]. This is in line with the results we have obtained, in which samples were classified based more on the EVs isolation method than on their origin (PCa patients or HDs) (Additional file
1: Figure S3). Despite this, correlation of miRNA profiles between the different isolation approaches was high in all cases, being better between UC and SEC (Table
2). Interestingly, when miRNA expression was divided into quartiles, the best correlation coefficients (R
2) were obtained in q4 (higher number of miRNAs) with a R
2 = 0.97 between SEC and UC, the correlation in q2 and q1 being lower (Additional file
1: Figure S15). To demonstrate that the isolation procedures influence at biological level, two sets of RNA were evaluated: the housekeeping genes provided by the assay and the
Let-7 family of miRNAs. This approach showed significant differences with regards number of reads for any of the two RNA sets of UC and SEC with Exolute® (Fig.
5), indicating that Exolute® provides the lowest performance from the biological point of view.
DEA between PCa cases and HDs for each EVs isolation method showed that a total of 21 and 3 miRNAs were differentially expressed between groups for SEC and UC respectively, and none for Exolute®. The only miRNA that was differentially expressed in both methods was miR-8052 [
52], a miRNA not previously described in PCa but in serum from sepsis patients with different outcomes [
53]. Remarkably, two of the 3 miRNAs differentially expressed in EVs isolated by UC from urine of PCa patients were miR-142-5p and miR-223-3p, two miRNA that have been recently described in EVs from urine isolated also by UC as non-invasive PCa diagnostic biomarkers [
54].
Although our study sample is limited, and further studies need to be addressed, our results point out to what other authors have suggested, the need of methodological standardization of EVs isolation and characterization to guaranty the success and reproducibility of the subsequent analysis, especially for clinical settings, where a large number of samples should be analysed [
55‐
57]. In this line, we suggest developing a codification system focused on the EV isolation and characterization variables like the SPREC codification system for pre-analytical conditions [
25] that we have introduce with our samples (Table
1) and that provides information on the handling of biological specimens before analysis, another critical point that not always comprehensively considered [
58,
59].
Publisher's Note