Skip to main content
Erschienen in: Clinical Oral Investigations 1/2009

01.03.2009 | Original Article

LCD and CRT display of storage phosphor plate and limited cone beam computed tomography images for the evaluation of root canal fillings

verfasst von: B. Güniz Baksı, Elif Soğur, Hans-Göran Gröndahl

Erschienen in: Clinical Oral Investigations | Ausgabe 1/2009

Einloggen, um Zugang zu erhalten

Abstract

The aim was to compare quality of liquid crystal display (LCD) and high resolution cathode ray tube (CRT) screens for the evaluation of length and homogeneity of root canal fillings in storage phosphor plate (SPP) and limited cone beam computed tomography (LCBCT) images. Endodontic treatment was performed to 17 extracted permanent lower incisor teeth. Images of each tooth positioned in a dried mandible were obtained with Digora® SPP and Accu-I-Tomo LCBCT systems. Six observers scored the quality of all images on CRT and LCD screens. Results were compared using McNemar’s and Cochran’s Q tests (p < 0.05). The differences among the LCBCT and SPP images were determined by binomial test. No significant difference was found between ratings of CRT and LCD displays (p > 0.05). Agreement among observers’ scores was higher with CRT display. Within the limits of this ex vivo study, differences between LCD and CRT monitors for the evaluation of root canal fillings are clinically insignificant independent on whether conventional radiographs, captured by means of image plates, or cone beam images are being displayed.
Literatur
1.
Zurück zum Zitat Abreu M Jr, Tyndall DA, Ludlow JB (1999) Detection of caries with conventional digital imaging and tuned-aperture computed tomography using CRT monitor and laptop displays. Oral Surg Oral Med Oral Pathol Oral Radiol and Endod 88:234–238CrossRef Abreu M Jr, Tyndall DA, Ludlow JB (1999) Detection of caries with conventional digital imaging and tuned-aperture computed tomography using CRT monitor and laptop displays. Oral Surg Oral Med Oral Pathol Oral Radiol and Endod 88:234–238CrossRef
2.
Zurück zum Zitat Akdeniz BG, Gröndahl HG, Magnusson B (2006) Accuracy of proximal caries depth measurements: comparison between limited cone beam computed tomography, storage phosphor and film radiography. Caries Res 40:202–207PubMedCrossRef Akdeniz BG, Gröndahl HG, Magnusson B (2006) Accuracy of proximal caries depth measurements: comparison between limited cone beam computed tomography, storage phosphor and film radiography. Caries Res 40:202–207PubMedCrossRef
3.
Zurück zum Zitat Baker WP 3rd, Loushine RJ, West LA, Kudryk LV, Zadinsky JR (2000) Interpretation of artificial and in vivo periapical bone lesions comparing conventional viewing versus a video conferencing system. J Endod 26:39–41PubMedCrossRef Baker WP 3rd, Loushine RJ, West LA, Kudryk LV, Zadinsky JR (2000) Interpretation of artificial and in vivo periapical bone lesions comparing conventional viewing versus a video conferencing system. J Endod 26:39–41PubMedCrossRef
4.
Zurück zum Zitat Cederberg RA, Frederiksen NL, Benson BW, Shulman JD (1999) Influence of the digital image display monitor on observer performance. Dentomaxillofac Radiol 28:203–207PubMedCrossRef Cederberg RA, Frederiksen NL, Benson BW, Shulman JD (1999) Influence of the digital image display monitor on observer performance. Dentomaxillofac Radiol 28:203–207PubMedCrossRef
5.
Zurück zum Zitat Compton K (2001) Factors affecting cathode ray tube display performance. J Digit Imaging 14:92–106PubMedCrossRef Compton K (2001) Factors affecting cathode ray tube display performance. J Digit Imaging 14:92–106PubMedCrossRef
6.
Zurück zum Zitat Donner A, Eliasziw M (1994) Statistical implications of the choice between a dichotomous or continuous trait in studies of inter-observer agreement. Biometrics 50:550–555PubMedCrossRef Donner A, Eliasziw M (1994) Statistical implications of the choice between a dichotomous or continuous trait in studies of inter-observer agreement. Biometrics 50:550–555PubMedCrossRef
7.
Zurück zum Zitat Finger WJ, Ahlstrand WM, Fritz UB (2002) Radiopacity of fiber-reinforced resin posts. Am J Dent 15:81–84PubMed Finger WJ, Ahlstrand WM, Fritz UB (2002) Radiopacity of fiber-reinforced resin posts. Am J Dent 15:81–84PubMed
8.
Zurück zum Zitat Gröndahl HG, Huumonen S (2004) Radiographic manifestations of periapical inflammatory lesions. Endod Topics 8:55–67CrossRef Gröndahl HG, Huumonen S (2004) Radiographic manifestations of periapical inflammatory lesions. Endod Topics 8:55–67CrossRef
9.
Zurück zum Zitat Hirsch E, Graf H-L, Hemprich A (2003) Comparative investigation of image quality of three different x-ray procedures. Dentomaxillofac Radiol 32:201–211CrossRef Hirsch E, Graf H-L, Hemprich A (2003) Comparative investigation of image quality of three different x-ray procedures. Dentomaxillofac Radiol 32:201–211CrossRef
10.
Zurück zum Zitat Holberg C, Steinhäuser S, Geis P, Rudzki-Janson I (2005) Cone-beam computed tomography in orthodontics: benefits and limitations. J Orofac Orthop 66:434–444PubMedCrossRef Holberg C, Steinhäuser S, Geis P, Rudzki-Janson I (2005) Cone-beam computed tomography in orthodontics: benefits and limitations. J Orofac Orthop 66:434–444PubMedCrossRef
11.
Zurück zum Zitat Kamitani T, Yabuuchi H, Soeda H, Matsuo Y, Okafuji T, Sakai S, Furuya A, Hatakenaka M, Ishii N, Honda H (2007) Detection of masses and microcalcifications of breast cancer on digital mammograms: comparison among hard-copy film, 3-megapixel liquid crystal display (LCD) monitors and 5-megapixel LCD monitors: an observer performance study. Eur Radiol 17:1365–1371PubMedCrossRef Kamitani T, Yabuuchi H, Soeda H, Matsuo Y, Okafuji T, Sakai S, Furuya A, Hatakenaka M, Ishii N, Honda H (2007) Detection of masses and microcalcifications of breast cancer on digital mammograms: comparison among hard-copy film, 3-megapixel liquid crystal display (LCD) monitors and 5-megapixel LCD monitors: an observer performance study. Eur Radiol 17:1365–1371PubMedCrossRef
12.
Zurück zum Zitat Kim AY, Cho KS, Song KS, Kim JH, Kim JG, Ha HK (2001) Urinary calculi on computed radiography: comparison of observer performance with hard-copy versus soft-copy images on different viewer systems. AJR Am J Roentgenol 177:331–335PubMed Kim AY, Cho KS, Song KS, Kim JH, Kim JG, Ha HK (2001) Urinary calculi on computed radiography: comparison of observer performance with hard-copy versus soft-copy images on different viewer systems. AJR Am J Roentgenol 177:331–335PubMed
13.
Zurück zum Zitat Ludlow JB, Abreu M Jr (1999) Performance of film, desktop monitor and laptop displays in caries detection. Dentomaxillofac Radiol 28:26–30PubMedCrossRef Ludlow JB, Abreu M Jr (1999) Performance of film, desktop monitor and laptop displays in caries detection. Dentomaxillofac Radiol 28:26–30PubMedCrossRef
14.
Zurück zum Zitat Mileman PA, van den Hout WB, Sanderink GC (2003) Randomized controlled trial of a computer-assisted learning program to improve caries detection from bitewing radiographs. Dentomaxillofac Radiol 32:116–123PubMedCrossRef Mileman PA, van den Hout WB, Sanderink GC (2003) Randomized controlled trial of a computer-assisted learning program to improve caries detection from bitewing radiographs. Dentomaxillofac Radiol 32:116–123PubMedCrossRef
15.
Zurück zum Zitat Møystad A, Svanaes DB, Larheim TA, Gröndahl HG (1994) The effect of cathode ray tube display format on observer performance in dental digitized radiography: comparison with plain films. Dentomaxillofac Radiol 23:206–210PubMed Møystad A, Svanaes DB, Larheim TA, Gröndahl HG (1994) The effect of cathode ray tube display format on observer performance in dental digitized radiography: comparison with plain films. Dentomaxillofac Radiol 23:206–210PubMed
16.
Zurück zum Zitat Mozzo P, Procacci C, Tacconi A, Martini PT, Andreis IA (1998) A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results. Eur Radiol 8:1558–1564PubMedCrossRef Mozzo P, Procacci C, Tacconi A, Martini PT, Andreis IA (1998) A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results. Eur Radiol 8:1558–1564PubMedCrossRef
17.
Zurück zum Zitat Patel S, Dawood A, Ford TP, Whaites E (2007) The potential applications of cone beam computed tomography in the management of endodontic problems. Int Endod J 40:818–830PubMedCrossRef Patel S, Dawood A, Ford TP, Whaites E (2007) The potential applications of cone beam computed tomography in the management of endodontic problems. Int Endod J 40:818–830PubMedCrossRef
18.
Zurück zum Zitat Samei E, Rowberg A, Avraham E, Cornelius C (2004) Toward clinically relevant standardization of image quality. J Digit Imaging 17:271–278PubMedCrossRef Samei E, Rowberg A, Avraham E, Cornelius C (2004) Toward clinically relevant standardization of image quality. J Digit Imaging 17:271–278PubMedCrossRef
19.
Zurück zum Zitat Sarma KR, Akinwande T (1996) Flat Panel Displays for Portable Systems. J VLST Signal Process Syst Signal Image Video Technol 13:165–190CrossRef Sarma KR, Akinwande T (1996) Flat Panel Displays for Portable Systems. J VLST Signal Process Syst Signal Image Video Technol 13:165–190CrossRef
20.
Zurück zum Zitat Sogur E, Baksi BG, Gröndahl HG (2007) Imaging of root canal fillings: a comparison of subjective image quality between limited cone-beam CT, storage phosphor and film radiography. Int Endod J 40:179–185PubMedCrossRef Sogur E, Baksi BG, Gröndahl HG (2007) Imaging of root canal fillings: a comparison of subjective image quality between limited cone-beam CT, storage phosphor and film radiography. Int Endod J 40:179–185PubMedCrossRef
21.
Zurück zum Zitat Stavropoulos A, Wenzel A (2007) Accuracy of cone beam dental CT, intraoral digital and conventional film radiography for the detection of periapical lesionsAn ex vivo study in pig jaws. Clin Oral Invest 11:1001–1006CrossRef Stavropoulos A, Wenzel A (2007) Accuracy of cone beam dental CT, intraoral digital and conventional film radiography for the detection of periapical lesionsAn ex vivo study in pig jaws. Clin Oral Invest 11:1001–1006CrossRef
22.
Zurück zum Zitat Wang J, Anderson J, Lane T, Stetson C, Moore J (2000) Contrast-detail characteristics evaluations of several display devices. J Digit Imaging 13:62–67CrossRef Wang J, Anderson J, Lane T, Stetson C, Moore J (2000) Contrast-detail characteristics evaluations of several display devices. J Digit Imaging 13:62–67CrossRef
23.
Zurück zum Zitat Wenzel A, Hintze H, Mikkelsen L, Mouyen F (1991) Radiographic detection of occlusal caries in noncavitated teethA comparison of conventional film radiographs, digitized film radiographs, and RadioVisioGraphy. Oral Surg Oral Med Oral Pathol 72:621–626PubMedCrossRef Wenzel A, Hintze H, Mikkelsen L, Mouyen F (1991) Radiographic detection of occlusal caries in noncavitated teethA comparison of conventional film radiographs, digitized film radiographs, and RadioVisioGraphy. Oral Surg Oral Med Oral Pathol 72:621–626PubMedCrossRef
Metadaten
Titel
LCD and CRT display of storage phosphor plate and limited cone beam computed tomography images for the evaluation of root canal fillings
verfasst von
B. Güniz Baksı
Elif Soğur
Hans-Göran Gröndahl
Publikationsdatum
01.03.2009
Verlag
Springer-Verlag
Erschienen in
Clinical Oral Investigations / Ausgabe 1/2009
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-008-0211-y

Weitere Artikel der Ausgabe 1/2009

Clinical Oral Investigations 1/2009 Zur Ausgabe

List of Authors

List of authors

Parodontalbehandlung verbessert Prognose bei Katheterablation

19.04.2024 Vorhofflimmern Nachrichten

Werden Personen mit Vorhofflimmern in der Blanking-Periode nach einer Katheterablation gegen eine bestehende Parodontitis behandelt, verbessert dies die Erfolgsaussichten. Dafür sprechen die Resultate einer prospektiven Untersuchung.

Invasive Zahnbehandlung: Wann eine Antibiotikaprophylaxe vor infektiöser Endokarditis schützt

11.04.2024 Endokarditis Nachrichten

Bei welchen Personen eine Antibiotikaprophylaxe zur Prävention einer infektiösen Endokarditis nach invasiven zahnärztlichen Eingriffen sinnvoll ist, wird diskutiert. Neue Daten stehen im Einklang mit den europäischen Leitlinienempfehlungen.

Zell-Organisatoren unter Druck: Mechanismen des embryonalen Zahnwachstums aufgedeckt

08.04.2024 Zahnmedizin Nachrichten

Der Aufbau von Geweben und Organen während der Embryonalentwicklung wird von den Zellen bemerkenswert choreografiert. Für diesen Prozess braucht es spezielle sogenannte „Organisatoren“. In einer aktuellen Veröffentlichung im Fachjournal Nature Cell Biology berichten Forschende durch welchen Vorgang diese Organisatoren im Gewebe entstehen und wie sie dann die Bildung von Zähnen orchestrieren.

Die Oralprophylaxe & Kinderzahnheilkunde umbenannt

11.03.2024 Kinderzahnmedizin Nachrichten

Infolge der Umbenennung der Deutschen Gesellschaft für Kinderzahnheilkunde in Deutsche Gesellschaft für Kinderzahnmedizin (DGKiZ) wird deren Mitgliederzeitschrift Oralprophylaxe & Kinderzahnheilkunde in Oralprophylaxe & Kinderzahnmedizin umbenannt. Aus diesem Grunde trägt die erste Ausgabe in 2024 erstmalig den neuen Titel.

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.