Skip to main content
Erschienen in: International Urogynecology Journal 10/2012

01.10.2012 | Original Article

Comparison of vaginal mesh extrusion rates between a lightweight type I polypropylene mesh versus heavier mesh in the treatment of pelvic organ prolapse

verfasst von: Robert D. Moore, James C. Lukban

Erschienen in: International Urogynecology Journal | Ausgabe 10/2012

Einloggen, um Zugang zu erhalten

Abstract

Introduction and hypothesis

The objective of the study was to compare extrusion (vaginal mesh exposure) rates in patients undergoing transvaginal prolapse repair with the trocar-based Apogee and/or Perigee devices (American Medical Systems, Minnetonka, MN, USA) using either the original type I polypropylene mesh (IntePro, American Medical Systems, Minnetonka, MN, USA) or a newer generation lightweight type I mesh (IntePro Lite, American Medical Systems, Minnetonka, MN, USA).

Methods

Data were pooled from three similarly designed prospective multicenter studies evaluating the safety and efficacy of Perigee for correction of the anterior (AC) and/or Apogee to repair the posterior/apical (PC/A) compartments. The first two studies utilized IntePro (mesh density 50 g/m2) and the third utilized IntePro Lite (mesh density 25.2 g/m2). Data were pooled to form IntePro and IntePro Lite groups for comparison. Patient demographics were recorded. Risk factors for vaginal mesh exposure were also considered.

Results

Two hundred and sixty-three patients were implanted with Perigee and/or Apogee with IntePro for a total of 371 heavier mesh implants (174 Perigee, 197 Apogee) compared to 86 patients who underwent Perigee and/or Apogee with IntePro Lite for a total of 116 lightweight mesh implants (60 Perigee, 56 Apogee). Demographics and potential risk factors for extrusion were compared between the two groups. Mean follow-up was 2.0 years and similar between the two groups. In the AC, there were 234 implants, with mesh extrusion occurring in 8.0 % following IntePro compared to 5.0 % following IntePro Lite (p = 0.57). In the PA/C, there were 253 implants, with mesh extrusion occurring in 13.7 % following IntePro compared to 7.1 % following IntePro Lite (p = 0.25). Overall mesh extrusion rates in 487 implants in all compartments were found to be 11.1 % with IntePro versus 6.0 % with IntePro Lite with an estimated odds ratio of 1.93 (95 % confidence interval 0.84–4.44, p = 0.12).

Conclusions

No statistically significant difference in extrusion rates were seen following use of IntePro versus IntePro Lite; however, the 46 % reduction in rate of mesh exposure observed in those receiving the lighter weight mesh may represent clinical importance.
Literatur
1.
Zurück zum Zitat Beer M, Kuhn A (2005) Surgical techniques for vault prolapse: a review of the literature. Eur J Obstet Gynecol Reprod Biol 119:144–155PubMedCrossRef Beer M, Kuhn A (2005) Surgical techniques for vault prolapse: a review of the literature. Eur J Obstet Gynecol Reprod Biol 119:144–155PubMedCrossRef
2.
Zurück zum Zitat Olsen AL, Smith VJ, Bergstrom JO et al (1997) Epidemiology of surgically managed pelvic organ prolapse and urinary incontinence. Obstet Gynecol 89:501–506PubMedCrossRef Olsen AL, Smith VJ, Bergstrom JO et al (1997) Epidemiology of surgically managed pelvic organ prolapse and urinary incontinence. Obstet Gynecol 89:501–506PubMedCrossRef
3.
Zurück zum Zitat Maher C, Baessler K (2006) Surgical management of anterior vaginal wall prolapse: an evidence based literature review. Int Urogynecol J Pelvic Floor Dysfunct 17:195–201PubMedCrossRef Maher C, Baessler K (2006) Surgical management of anterior vaginal wall prolapse: an evidence based literature review. Int Urogynecol J Pelvic Floor Dysfunct 17:195–201PubMedCrossRef
4.
Zurück zum Zitat Weber AM, Walters MD, Piedmonte MR, Ballard LA (2001) Anterior colporrhaphy: a randomized trial of three surgical techniques. Am J Obstet Gynecol 185:1299–1304, discussion 1304–1306PubMedCrossRef Weber AM, Walters MD, Piedmonte MR, Ballard LA (2001) Anterior colporrhaphy: a randomized trial of three surgical techniques. Am J Obstet Gynecol 185:1299–1304, discussion 1304–1306PubMedCrossRef
5.
Zurück zum Zitat Burger JW, Luijendijk RW, Hop WC, Halm JA, Verdaasdonk EG, Jeekel J (2004) Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia. Ann Surg 240:578–583; discussion 583–585PubMed Burger JW, Luijendijk RW, Hop WC, Halm JA, Verdaasdonk EG, Jeekel J (2004) Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia. Ann Surg 240:578–583; discussion 583–585PubMed
6.
Zurück zum Zitat Amid PK, Lichtenstein IL (1997) Current assessment of Lichtenstein tension-free hernia repair. Chirurg 68:959–964PubMedCrossRef Amid PK, Lichtenstein IL (1997) Current assessment of Lichtenstein tension-free hernia repair. Chirurg 68:959–964PubMedCrossRef
7.
Zurück zum Zitat Cosson M, Debodinance P, Boukerrou M et al (2003) Mechanical properties of synthetic implants used in the repair of prolapse and urinary incontinence in women: which is the ideal material? Int Urogynecol J Pelvic Floor Dysfunct 14:169–178, discussion 178PubMedCrossRef Cosson M, Debodinance P, Boukerrou M et al (2003) Mechanical properties of synthetic implants used in the repair of prolapse and urinary incontinence in women: which is the ideal material? Int Urogynecol J Pelvic Floor Dysfunct 14:169–178, discussion 178PubMedCrossRef
8.
Zurück zum Zitat Boulanger L, Boukerrou M, Lambaudie E et al (2006) Tissue integration and tolerance to meshes used in gynecologic surgery: an experimental study. Eur J Obstet Gynecol Reprod Biol 125:103–108PubMedCrossRef Boulanger L, Boukerrou M, Lambaudie E et al (2006) Tissue integration and tolerance to meshes used in gynecologic surgery: an experimental study. Eur J Obstet Gynecol Reprod Biol 125:103–108PubMedCrossRef
9.
Zurück zum Zitat Hiltunen R, Nieminen K, Takala T et al (2007) Low-weight polypropylene mesh for anterior vaginal wall prolapse: a randomized controlled trial. Obstet Gynecol 110:455–462PubMedCrossRef Hiltunen R, Nieminen K, Takala T et al (2007) Low-weight polypropylene mesh for anterior vaginal wall prolapse: a randomized controlled trial. Obstet Gynecol 110:455–462PubMedCrossRef
10.
Zurück zum Zitat Nguyen JN, Burchette RJ (2008) Outcome after anterior vaginal prolapse repair: a randomized controlled trial. Obstet Gynecol 111:891–898PubMedCrossRef Nguyen JN, Burchette RJ (2008) Outcome after anterior vaginal prolapse repair: a randomized controlled trial. Obstet Gynecol 111:891–898PubMedCrossRef
11.
Zurück zum Zitat Withagen MI, Milani AL, den Boon J et al (2011) Trocar-guided mesh compared with conventional vaginal repair in recurrent prolapse: a randomized controlled trial. Obstet Gynecol 117(2):242–250PubMedCrossRef Withagen MI, Milani AL, den Boon J et al (2011) Trocar-guided mesh compared with conventional vaginal repair in recurrent prolapse: a randomized controlled trial. Obstet Gynecol 117(2):242–250PubMedCrossRef
12.
Zurück zum Zitat Moore RD, Miklos JR (2009) Vaginal mesh kits for pelvic organ prolapse, friend or foe: a comprehensive review. ScientificWorldJournal 9:163–189PubMedCrossRef Moore RD, Miklos JR (2009) Vaginal mesh kits for pelvic organ prolapse, friend or foe: a comprehensive review. ScientificWorldJournal 9:163–189PubMedCrossRef
13.
Zurück zum Zitat Nieminen K, Hiltunen R, Takala T et al (2010) Outcomes after anterior vaginal wall repair with mesh: a randomized, controlled trial with a 3 year follow-up. Am J Obstet Gynecol 203(3):235.e1–235.e8CrossRef Nieminen K, Hiltunen R, Takala T et al (2010) Outcomes after anterior vaginal wall repair with mesh: a randomized, controlled trial with a 3 year follow-up. Am J Obstet Gynecol 203(3):235.e1–235.e8CrossRef
14.
Zurück zum Zitat Maher C, Baessler K, Glazener CM et al (2008) Surgical management of pelvic organ prolapse in women: a short version Cochrane review. Neurourol Urodyn 27(1):3–12PubMedCrossRef Maher C, Baessler K, Glazener CM et al (2008) Surgical management of pelvic organ prolapse in women: a short version Cochrane review. Neurourol Urodyn 27(1):3–12PubMedCrossRef
15.
16.
Zurück zum Zitat Margulies RU, Lewicky-Gaupp C, Fenner DE et al (2008) Complications requiring reoperation following vaginal mesh kit procedures for prolapse. Am J Obstet Gynecol 199:678e1–678e4CrossRef Margulies RU, Lewicky-Gaupp C, Fenner DE et al (2008) Complications requiring reoperation following vaginal mesh kit procedures for prolapse. Am J Obstet Gynecol 199:678e1–678e4CrossRef
17.
Zurück zum Zitat Ridgeway B, Walters MD, Paraiso MF et al (2008) Early experience with mesh excision for adverse outcomes after transvaginal mesh placement using prolapse kits. Am J Obstet Gynecol 199:703e1–703e7CrossRef Ridgeway B, Walters MD, Paraiso MF et al (2008) Early experience with mesh excision for adverse outcomes after transvaginal mesh placement using prolapse kits. Am J Obstet Gynecol 199:703e1–703e7CrossRef
18.
Zurück zum Zitat Iglesia CB, Sokol AL, Sokol ER et al (2010) Vaginal mesh for prolapse: a randomized controlled trial. Obstet Gynecol 116(2 Pt 1):293–303PubMedCrossRef Iglesia CB, Sokol AL, Sokol ER et al (2010) Vaginal mesh for prolapse: a randomized controlled trial. Obstet Gynecol 116(2 Pt 1):293–303PubMedCrossRef
19.
Zurück zum Zitat Moore R, Miklos J (2009) Vaginal repair of cystocele with anterior wall mesh via transobturator route: efficacy and complications with up to 3-year followup. Adv Urol 2009:743831 Moore R, Miklos J (2009) Vaginal repair of cystocele with anterior wall mesh via transobturator route: efficacy and complications with up to 3-year followup. Adv Urol 2009:743831
20.
Zurück zum Zitat Gauruder-Burmester A, Koutouzidou P, Rohne J et al (2007) Follow-up after polypropylene mesh repair of anterior and posterior compartments in patients with recurrent prolapse. Int Urogynecol J Pelvic Floor Dysfunct 18:1059–1064PubMedCrossRef Gauruder-Burmester A, Koutouzidou P, Rohne J et al (2007) Follow-up after polypropylene mesh repair of anterior and posterior compartments in patients with recurrent prolapse. Int Urogynecol J Pelvic Floor Dysfunct 18:1059–1064PubMedCrossRef
21.
Zurück zum Zitat Altman D, Falconer C (2007) Perioperative morbidity using transvaginal mesh in pelvic organ prolapse repair. Obstet Gynecol 109(2 Pt 1):303–308PubMedCrossRef Altman D, Falconer C (2007) Perioperative morbidity using transvaginal mesh in pelvic organ prolapse repair. Obstet Gynecol 109(2 Pt 1):303–308PubMedCrossRef
22.
Zurück zum Zitat Nygaard IE, McCreery R, Brubaker L (2004) Abdominal sacrocolpopexy: a comprehensive review. Obstet Gynecol 104(4):805–823PubMedCrossRef Nygaard IE, McCreery R, Brubaker L (2004) Abdominal sacrocolpopexy: a comprehensive review. Obstet Gynecol 104(4):805–823PubMedCrossRef
23.
Zurück zum Zitat Stepanian AA, Miklos JR, Moore RD, Mattox TF (2008) Risk of mesh extrusion and other mesh-related complications after laparoscopic sacral colpopexy with or without concurrent laparoscopic-assisted vaginal hysterectomy: experience of 402 patients. J Minim Invasive Gynecol 15(2):188–196PubMedCrossRef Stepanian AA, Miklos JR, Moore RD, Mattox TF (2008) Risk of mesh extrusion and other mesh-related complications after laparoscopic sacral colpopexy with or without concurrent laparoscopic-assisted vaginal hysterectomy: experience of 402 patients. J Minim Invasive Gynecol 15(2):188–196PubMedCrossRef
24.
Zurück zum Zitat Moore RD, Mitchell GK, Miklos JR (2012) Single-incision vaginal approach to treat cystocele and vault prolapse with an anterior wall mesh anchored apically to the sacrospinous ligaments. Int Urogynecol J 23(1):85–91PubMedCrossRef Moore RD, Mitchell GK, Miklos JR (2012) Single-incision vaginal approach to treat cystocele and vault prolapse with an anterior wall mesh anchored apically to the sacrospinous ligaments. Int Urogynecol J 23(1):85–91PubMedCrossRef
Metadaten
Titel
Comparison of vaginal mesh extrusion rates between a lightweight type I polypropylene mesh versus heavier mesh in the treatment of pelvic organ prolapse
verfasst von
Robert D. Moore
James C. Lukban
Publikationsdatum
01.10.2012
Verlag
Springer-Verlag
Erschienen in
International Urogynecology Journal / Ausgabe 10/2012
Print ISSN: 0937-3462
Elektronische ISSN: 1433-3023
DOI
https://doi.org/10.1007/s00192-012-1744-9

Weitere Artikel der Ausgabe 10/2012

International Urogynecology Journal 10/2012 Zur Ausgabe

Ambulantisierung: Erste Erfahrungen mit dem Hybrid-DRG

02.05.2024 DCK 2024 Kongressbericht

Die Hybrid-DRG-Verordnung soll dazu führen, dass mehr chirurgische Eingriffe ambulant durchgeführt werden, wie es in anderen Ländern schon länger üblich ist. Die gleiche Vergütung im ambulanten und stationären Sektor hatten Niedergelassene schon lange gefordert. Aber die Umsetzung bereitet ihnen doch Kopfzerbrechen.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Harninkontinenz: Netz-Op. erfordert über lange Zeit intensive Nachsorge

30.04.2024 Harninkontinenz Nachrichten

Frauen mit Belastungsinkontinenz oder Organprolaps sind nach einer Netz-Operation keineswegs beschwerdefrei. Vielmehr scheint die Krankheitslast weiterhin hoch zu sein, sogar höher als von harninkontinenten Frauen, die sich nicht haben operieren lassen.

Welche Übungen helfen gegen Diastase recti abdominis?

30.04.2024 Schwangerenvorsorge Nachrichten

Die Autorinnen und Autoren einer aktuellen Studie aus Griechenland sind sich einig, dass Bewegungstherapie, einschließlich Übungen zur Stärkung der Bauchmuskulatur und zur Stabilisierung des Rumpfes, eine Diastase recti abdominis postpartum wirksam reduzieren kann. Doch vieles ist noch nicht eindeutig belegt.

Update Gynäkologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.