Skip to main content
Erschienen in: Osteoporosis International 2/2005

01.03.2005 | Original Article

Mechanical behavior of screws in normal and osteoporotic bone

verfasst von: J. Seebeck, J. Goldhahn, M. M. Morlock, E. Schneider

Erschienen in: Osteoporosis International | Sonderheft 2/2005

Einloggen, um Zugang zu erhalten

Abstract

Fracture fixation in severe osteoporotic bone by means of implants that rely on screw anchorage is still a clinical problem. So far, a sufficiently accurate prediction of the holding capacity of screws as a function of local bone morphology has not been obtained. In this study the ultimate pullout loads of screws in the epi-, meta-, and diaphyseal regions of human tibiae were correlated to the cortical thicknesses and cancellous bone mineral densities at the screw axes determined from QCT densitometric data. Stepwise multiple linear regression showed that in regions with cortical thicknesses below 1.5 mm, cancellous density determined the ultimate pullout load (R2=0.85, p<0.001), while in regions with cortices above 1.5 mm, cortical thickness alone significantly influenced the holding capacity of a screw (R2=0.90, p<0.001). The findings of this study provide a basis for a bone morphology-related pre-operative estimation of the holding capacity of screws, which could help to improve their proper application in osteoporotic bone.
Literatur
1.
Zurück zum Zitat Asnis SE, Ernberg JJ, Bostrom MP, Wright TM, Harrington RM, Tencer A, Peterson M (1996) Cancellous bone screw thread design and holding power. J Orthop Trauma 10:462–469CrossRefPubMed Asnis SE, Ernberg JJ, Bostrom MP, Wright TM, Harrington RM, Tencer A, Peterson M (1996) Cancellous bone screw thread design and holding power. J Orthop Trauma 10:462–469CrossRefPubMed
2.
Zurück zum Zitat Bloom RA (1980) A comparative estimation of the combined cortical thickness of various bone sites. Skeletal Radiol 5:167–170PubMed Bloom RA (1980) A comparative estimation of the combined cortical thickness of various bone sites. Skeletal Radiol 5:167–170PubMed
3.
Zurück zum Zitat Brown GA, McCarthy T, Bourgeault CA, Callahan DJ (2000) Mechanical performance of standard and cannulated 4.0-mm cancellous bone screws. J Orthop Res 18:307–312PubMed Brown GA, McCarthy T, Bourgeault CA, Callahan DJ (2000) Mechanical performance of standard and cannulated 4.0-mm cancellous bone screws. J Orthop Res 18:307–312PubMed
4.
Zurück zum Zitat Chapman JR, Harrington RM, Lee KM, Anderson PA, Tencer AF, Kowalski D (1996) Factors affecting the pullout strength of cancellous bone screws. J Biomech Eng 118:391–398PubMed Chapman JR, Harrington RM, Lee KM, Anderson PA, Tencer AF, Kowalski D (1996) Factors affecting the pullout strength of cancellous bone screws. J Biomech Eng 118:391–398PubMed
5.
Zurück zum Zitat DeCoster TA, Heetderks DB, Downey DJ, Ferries JS, Jones W (1990) Optimizing bone screw pullout force. J Orthop Trauma 4:169–174PubMed DeCoster TA, Heetderks DB, Downey DJ, Ferries JS, Jones W (1990) Optimizing bone screw pullout force. J Orthop Trauma 4:169–174PubMed
6.
Zurück zum Zitat Eckstein F, Lochmuller EM, Lill CA, Kuhn V, Schneider E, Delling G, Muller R (2002) Bone strength at clinically relevant sites displays substantial heterogeneity and is best predicted from site-specific bone densitometry. J Bone Miner Res 17:162–171PubMed Eckstein F, Lochmuller EM, Lill CA, Kuhn V, Schneider E, Delling G, Muller R (2002) Bone strength at clinically relevant sites displays substantial heterogeneity and is best predicted from site-specific bone densitometry. J Bone Miner Res 17:162–171PubMed
7.
Zurück zum Zitat Faran KJ, Ichioka N, Trzeciak MA, Han S, Medige J, Moy OJ (1999) Effect of bone quality on the forces generated by compression screws. J Biomech 32:861–864CrossRefPubMed Faran KJ, Ichioka N, Trzeciak MA, Han S, Medige J, Moy OJ (1999) Effect of bone quality on the forces generated by compression screws. J Biomech 32:861–864CrossRefPubMed
8.
Zurück zum Zitat Frigg R (2001) Locking compression plate (LCP): an osteosynthesis plate based on the dynamic compression plate and the Point Contact Fixator (PC-Fix). Injury 32 (Suppl) 2:63–66CrossRefPubMed Frigg R (2001) Locking compression plate (LCP): an osteosynthesis plate based on the dynamic compression plate and the Point Contact Fixator (PC-Fix). Injury 32 (Suppl) 2:63–66CrossRefPubMed
9.
Zurück zum Zitat Harnroongroj T, Techataweewan A (1999) Determination of the role of the cancellous bone in generation of screw holding power at metaphysis. Clin Biomech 14:364–366CrossRef Harnroongroj T, Techataweewan A (1999) Determination of the role of the cancellous bone in generation of screw holding power at metaphysis. Clin Biomech 14:364–366CrossRef
10.
Zurück zum Zitat Jergas M, Schmid G (1999) Conventional radiology of osteoporosis and radiographic absorptiometry. Radiologe 39:174–185CrossRefPubMed Jergas M, Schmid G (1999) Conventional radiology of osteoporosis and radiographic absorptiometry. Radiologe 39:174–185CrossRefPubMed
11.
Zurück zum Zitat Messmer P, Long G, Suhm N, Regazzoni P, Jacob AL (2001) Volumetric model determination of the tibia based on 2D radiographs using a 2D/3D database. Comput Aided Surg 6:183–194CrossRefPubMed Messmer P, Long G, Suhm N, Regazzoni P, Jacob AL (2001) Volumetric model determination of the tibia based on 2D radiographs using a 2D/3D database. Comput Aided Surg 6:183–194CrossRefPubMed
12.
Zurück zum Zitat Pearson J, Ruegsegger P, Dequeker J, Henley M, Bright J, Reeve J, Kalender W, Felsenberg D, Laval-Jeantet AM, Adams JE (1994) European semi-anthropomorphic phantom for the cross-calibration of peripheral bone densitometers: assessment of precision accuracy and stability. Bone Miner 27:109–120PubMed Pearson J, Ruegsegger P, Dequeker J, Henley M, Bright J, Reeve J, Kalender W, Felsenberg D, Laval-Jeantet AM, Adams JE (1994) European semi-anthropomorphic phantom for the cross-calibration of peripheral bone densitometers: assessment of precision accuracy and stability. Bone Miner 27:109–120PubMed
13.
Zurück zum Zitat Prevrhal S, Engelke K, Kalender WA (1999) Accuracy limits for the determination of cortical width and density: the influence of object size and CT imaging parameters. Phys Med Biol 44:751–764CrossRefPubMed Prevrhal S, Engelke K, Kalender WA (1999) Accuracy limits for the determination of cortical width and density: the influence of object size and CT imaging parameters. Phys Med Biol 44:751–764CrossRefPubMed
14.
Zurück zum Zitat Snyder SM, Schneider E (1991) Estimation of mechanical properties of cortical bone by computed tomography. J Orthop Res 9:422–431PubMed Snyder SM, Schneider E (1991) Estimation of mechanical properties of cortical bone by computed tomography. J Orthop Res 9:422–431PubMed
15.
Zurück zum Zitat Stromsoe K, Kok WL, Hoiseth A, Alho A (1993) Holding power of the 4.5 mm AO/ASIF cortex screw in cortical bone in relation to bone mineral. Injury 24:656–659CrossRefPubMed Stromsoe K, Kok WL, Hoiseth A, Alho A (1993) Holding power of the 4.5 mm AO/ASIF cortex screw in cortical bone in relation to bone mineral. Injury 24:656–659CrossRefPubMed
Metadaten
Titel
Mechanical behavior of screws in normal and osteoporotic bone
verfasst von
J. Seebeck
J. Goldhahn
M. M. Morlock
E. Schneider
Publikationsdatum
01.03.2005
Verlag
Springer-Verlag
Erschienen in
Osteoporosis International / Ausgabe Sonderheft 2/2005
Print ISSN: 0937-941X
Elektronische ISSN: 1433-2965
DOI
https://doi.org/10.1007/s00198-004-1777-0

Weitere Artikel der Sonderheft 2/2005

Osteoporosis International 2/2005 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.