Skip to main content
Erschienen in: Osteoporosis International 6/2008

01.06.2008 | Review Article

Influence of osteoporosis on fracture fixation - a systematic literature review

verfasst von: J. Goldhahn, N. Suhm, S. Goldhahn, M. Blauth, B. Hanson

Erschienen in: Osteoporosis International | Ausgabe 6/2008

Einloggen, um Zugang zu erhalten

Abstract

Summary

The goal of our systematic literature search was to prove whether the experimentally shown influence of osteoporosis on fracture fixation could be confirmed in clinical studies. Despite significant effects in several studies, this is not supported by pooled data due to lack of accurate osteoporosis assessment and complication definitions.

Introduction

The fact that osteoporosis causes fractures is well-known; the assumption that it aggravates their orthopaedic treatment has not been proven. The goal of our systematic literature search was to find out whether the experimentally proven influence of osteoporosis on fracture fixation could be confirmed in clinical studies.

Methods

A systematic electronic database search was performed identifying articles that evaluated complications after fracture fixation among patients suspected of having osteoporosis as measured by BMD or surrogates including Singh index or risk factors. To determine complications risks (relative risk within 95% confidence interval) data were pooled across studies, weighted by sample size and stratified by treatment type.

Results

Ten studies out of 77 randomized controlled trials (51 hip, 23 distal radius and three proximal humerus studies) and three systematic reviews finally met eligibility criteria. Despite significant differences of the relative complication risk between osteoporotic and non-osteoporotic patients in several studies, this could not be proven in the pooled data.

Conclusions

In contrast to biomechanical evidence that local osteoporosis affects anchorage of implants, this could not be reproduced in clinical studies, due to the lack of accurate osteoporosis assessment, missing complication definitions and heterogeneous inclusion criteria in these studies. Prospective studies are required that address specifically the correlation between local bone status and the risk of fixation failure.
Literatur
1.
Zurück zum Zitat Schneider E, Goldhahn J, Burckhardt P (2005) The challenge: fracture treatment in osteoporotic bone. Osteoporos Int 16(Suppl 2):S1–2PubMedCrossRef Schneider E, Goldhahn J, Burckhardt P (2005) The challenge: fracture treatment in osteoporotic bone. Osteoporos Int 16(Suppl 2):S1–2PubMedCrossRef
2.
Zurück zum Zitat Osteoporosis Prevention, Diagnosis, and Therapy (2000) NIH Consensus Statement 17:1–36 Osteoporosis Prevention, Diagnosis, and Therapy (2000) NIH Consensus Statement 17:1–36
4.
Zurück zum Zitat Klotzbuecher CM, Ross PD, Landsman PB, Abbott TA, 3rd, Berger M (2000) Patients with prior fractures have an increased risk of future fractures: a summary of the literature and statistical synthesis. J Bone Miner Res 15:721–739PubMedCrossRef Klotzbuecher CM, Ross PD, Landsman PB, Abbott TA, 3rd, Berger M (2000) Patients with prior fractures have an increased risk of future fractures: a summary of the literature and statistical synthesis. J Bone Miner Res 15:721–739PubMedCrossRef
5.
Zurück zum Zitat Kanis JA, Johnell O, De Laet C, Johansson H, Oden A, Delmas P, Eisman J, Fujiwara S, Garnero P, Kroger H, McCloskey EV, Mellstrom D, Melton LJ, Pols H, Reeve J, Silman A, Tenenhouse A (2004) A meta-analysis of previous fracture and subsequent fracture risk. Bone 35:375–382PubMedCrossRef Kanis JA, Johnell O, De Laet C, Johansson H, Oden A, Delmas P, Eisman J, Fujiwara S, Garnero P, Kroger H, McCloskey EV, Mellstrom D, Melton LJ, Pols H, Reeve J, Silman A, Tenenhouse A (2004) A meta-analysis of previous fracture and subsequent fracture risk. Bone 35:375–382PubMedCrossRef
6.
Zurück zum Zitat Chao EY, Inoue N, Koo TK, Kim YH (2004) Biomechanical considerations of fracture treatment and bone quality maintenance in elderly patients and patients with osteoporosis. Clin Orthop:12–25 Chao EY, Inoue N, Koo TK, Kim YH (2004) Biomechanical considerations of fracture treatment and bone quality maintenance in elderly patients and patients with osteoporosis. Clin Orthop:12–25
7.
Zurück zum Zitat Seebeck J, Goldhahn J, Stadele H, Messmer P, Morlock MM, Schneider E (2004) Effect of cortical thickness and cancellous bone density on the holding strength of internal fixator screws. J Orthop Res 22:1237–1242PubMedCrossRef Seebeck J, Goldhahn J, Stadele H, Messmer P, Morlock MM, Schneider E (2004) Effect of cortical thickness and cancellous bone density on the holding strength of internal fixator screws. J Orthop Res 22:1237–1242PubMedCrossRef
8.
Zurück zum Zitat Pitzen T, Franta F, Barbier D, Steudel WI (2004) Insertion torque and pullout force of rescue screws for anterior cervical plate fixation in a fatigued initial pilot hole. J Neurosurg Spine 1:198–201PubMedCrossRef Pitzen T, Franta F, Barbier D, Steudel WI (2004) Insertion torque and pullout force of rescue screws for anterior cervical plate fixation in a fatigued initial pilot hole. J Neurosurg Spine 1:198–201PubMedCrossRef
9.
Zurück zum Zitat Koistinen A, Santavirta SS, Kroger H, Lappalainen R (2005) Effect of bone mineral density and amorphous diamond coatings on insertion torque of bone screws. Biomaterials 26:5687–5694PubMedCrossRef Koistinen A, Santavirta SS, Kroger H, Lappalainen R (2005) Effect of bone mineral density and amorphous diamond coatings on insertion torque of bone screws. Biomaterials 26:5687–5694PubMedCrossRef
10.
Zurück zum Zitat Bonnaire F, Zenker H, Lill C, Weber AT, Linke B (2005) Treatment strategies for proximal femur fractures in osteoporotic patients. Osteoporos Int 16(Suppl 2):S93–S102PubMedCrossRef Bonnaire F, Zenker H, Lill C, Weber AT, Linke B (2005) Treatment strategies for proximal femur fractures in osteoporotic patients. Osteoporos Int 16(Suppl 2):S93–S102PubMedCrossRef
11.
Zurück zum Zitat Dvorak MF, Pitzen T, Zhu Q, Gordon JD, Fisher CG, Oxland TR (2005) Anterior cervical plate fixation: a biomechanical study to evaluate the effects of plate design, endplate preparation, and bone mineral density. Spine 30:294–301PubMedCrossRef Dvorak MF, Pitzen T, Zhu Q, Gordon JD, Fisher CG, Oxland TR (2005) Anterior cervical plate fixation: a biomechanical study to evaluate the effects of plate design, endplate preparation, and bone mineral density. Spine 30:294–301PubMedCrossRef
12.
Zurück zum Zitat Fankhauser F, Schippinger G, Weber K, Heinz S, Quehenberger F, Boldin C, Bratschitsch G, Szyszkowitz R, Georg L, Friedrich A (2003) Cadaveric-biomechanical evaluation of bone-implant construct of proximal humerus fractures (Neer type 3). J Trauma 55:345–349PubMedCrossRef Fankhauser F, Schippinger G, Weber K, Heinz S, Quehenberger F, Boldin C, Bratschitsch G, Szyszkowitz R, Georg L, Friedrich A (2003) Cadaveric-biomechanical evaluation of bone-implant construct of proximal humerus fractures (Neer type 3). J Trauma 55:345–349PubMedCrossRef
13.
Zurück zum Zitat Knoller SM, Meyer G, Eckhardt C, Lill CA, Schneider E, Linke B (2005) Range of motion in reconstruction situations following corpectomy in the lumbar spine: a question of bone mineral density? Spine 30:E229–235PubMedCrossRef Knoller SM, Meyer G, Eckhardt C, Lill CA, Schneider E, Linke B (2005) Range of motion in reconstruction situations following corpectomy in the lumbar spine: a question of bone mineral density? Spine 30:E229–235PubMedCrossRef
14.
Zurück zum Zitat Reinhold M, Schwieger K, Goldhahn J, Linke B, Knop C, Blauth M (2006) Influence of screw positioning in a new anterior spine fixator on implant loosening in osteoporotic vertebrae. Spine 31:406–413PubMedCrossRef Reinhold M, Schwieger K, Goldhahn J, Linke B, Knop C, Blauth M (2006) Influence of screw positioning in a new anterior spine fixator on implant loosening in osteoporotic vertebrae. Spine 31:406–413PubMedCrossRef
15.
Zurück zum Zitat Yoshimine F, Latta LL, Milne EL (1993) Sliding characteristics of compression hip screws in the intertrochanteric fracture: a clinical study. J Orthop Trauma 7:348–353PubMedCrossRef Yoshimine F, Latta LL, Milne EL (1993) Sliding characteristics of compression hip screws in the intertrochanteric fracture: a clinical study. J Orthop Trauma 7:348–353PubMedCrossRef
16.
Zurück zum Zitat Barrios C, Brostrom LA, Stark A, Walheim G (1993) Healing complications after internal fixation of trochanteric hip fractures: the prognostic value of osteoporosis. J Orthop Trauma 7:438–442PubMedCrossRef Barrios C, Brostrom LA, Stark A, Walheim G (1993) Healing complications after internal fixation of trochanteric hip fractures: the prognostic value of osteoporosis. J Orthop Trauma 7:438–442PubMedCrossRef
17.
Zurück zum Zitat Davis TR, Sher JL, Horsman A, Simpson M, Porter BB, Checketts RG (1990) Intertrochanteric femoral fractures. Mechanical failure after internal fixation. J Bone Joint Surg Br 72:26–31PubMed Davis TR, Sher JL, Horsman A, Simpson M, Porter BB, Checketts RG (1990) Intertrochanteric femoral fractures. Mechanical failure after internal fixation. J Bone Joint Surg Br 72:26–31PubMed
18.
Zurück zum Zitat Kawaguchi S, Sawada K, Nabeta Y (1998) Cutting-out of the lag screw after internal fixation with the Asiatic gamma nail. Injury 29:47–53PubMedCrossRef Kawaguchi S, Sawada K, Nabeta Y (1998) Cutting-out of the lag screw after internal fixation with the Asiatic gamma nail. Injury 29:47–53PubMedCrossRef
19.
Zurück zum Zitat Kim WY, Han CH, Park JI, Kim JY (2001) Failure of intertrochanteric fracture fixation with a dynamic hip screw in relation to pre-operative fracture stability and osteoporosis. Int Orthop 25:360–362PubMedPubMedCentralCrossRef Kim WY, Han CH, Park JI, Kim JY (2001) Failure of intertrochanteric fracture fixation with a dynamic hip screw in relation to pre-operative fracture stability and osteoporosis. Int Orthop 25:360–362PubMedPubMedCentralCrossRef
20.
Zurück zum Zitat Nordin S, Zulkifli O, Faisham WI (2001) Mechanical failure of Dynamic Hip Screw (DHS) fixation in intertrochanteric fracture of the femur. Med J Malaysia 56(Suppl D):12–17PubMed Nordin S, Zulkifli O, Faisham WI (2001) Mechanical failure of Dynamic Hip Screw (DHS) fixation in intertrochanteric fracture of the femur. Med J Malaysia 56(Suppl D):12–17PubMed
21.
Zurück zum Zitat Pankovich AM, Tarabishy IE (1980) Ender nailing of intertrochanteric and subtrochanteric fractures of the femur. J Bone Joint Surg Am 62:635–645PubMed Pankovich AM, Tarabishy IE (1980) Ender nailing of intertrochanteric and subtrochanteric fractures of the femur. J Bone Joint Surg Am 62:635–645PubMed
22.
Zurück zum Zitat Spangler L, Cummings P, Tencer AF, Mueller BA, Mock C (2001) Biomechanical factors and failure of transcervical hip fracture repair. Injury 32:223–228PubMedCrossRef Spangler L, Cummings P, Tencer AF, Mueller BA, Mock C (2001) Biomechanical factors and failure of transcervical hip fracture repair. Injury 32:223–228PubMedCrossRef
23.
Zurück zum Zitat Weinrobe M, Stankewich CJ, Mueller B, Tencer AF (1998) Predicting the mechanical outcome of femoral neck fractures fixed with cancellous screws: an in vivo study. J Orthop Trauma 12:27–36; discussion 36–7PubMedCrossRef Weinrobe M, Stankewich CJ, Mueller B, Tencer AF (1998) Predicting the mechanical outcome of femoral neck fractures fixed with cancellous screws: an in vivo study. J Orthop Trauma 12:27–36; discussion 36–7PubMedCrossRef
24.
Zurück zum Zitat Heetveld MJ, Raaymakers EL, van Eck-Smit BL, van Walsum AD, Luitse JS (2005) Internal fixation for displaced fractures of the femoral neck. Does bone density affect clinical outcome? J Bone Joint Surg Br 87:367–373PubMedCrossRef Heetveld MJ, Raaymakers EL, van Eck-Smit BL, van Walsum AD, Luitse JS (2005) Internal fixation for displaced fractures of the femoral neck. Does bone density affect clinical outcome? J Bone Joint Surg Br 87:367–373PubMedCrossRef
25.
Zurück zum Zitat Barnett E, Nordin BE (1960) The radiological diagnosis of osteoporosis: a new approach. Clin Radiol 11:166–174CrossRef Barnett E, Nordin BE (1960) The radiological diagnosis of osteoporosis: a new approach. Clin Radiol 11:166–174CrossRef
26.
Zurück zum Zitat Wachter NJ, Augat P, Hoellen IP, Krischak GD, Sarkar MR, Mentzel M, Kinzl L, Claes L (2001) Predictive value of Singh index and bone mineral density measured by quantitative computed tomography in determining the local cancellous bone quality of the proximal femur. Clin Biomech 16:257–262CrossRef Wachter NJ, Augat P, Hoellen IP, Krischak GD, Sarkar MR, Mentzel M, Kinzl L, Claes L (2001) Predictive value of Singh index and bone mineral density measured by quantitative computed tomography in determining the local cancellous bone quality of the proximal femur. Clin Biomech 16:257–262CrossRef
27.
Zurück zum Zitat Koot VC, Kesselaer SM, Clevers GJ, de Hooge P, Weits T, van der Werken C (1996) Evaluation of the Singh index for measuring osteoporosis. J Bone Joint Surg Br 78:831–834PubMed Koot VC, Kesselaer SM, Clevers GJ, de Hooge P, Weits T, van der Werken C (1996) Evaluation of the Singh index for measuring osteoporosis. J Bone Joint Surg Br 78:831–834PubMed
28.
Zurück zum Zitat Eckstein F, Lochmuller EM, Lill CA, Kuhn V, Schneider E, Delling G, Muller R (2002) Bone strength at clinically relevant sites displays substantial heterogeneity and is best predicted from site-specific bone densitometry. J Bone Miner Res 17:162–171PubMedCrossRef Eckstein F, Lochmuller EM, Lill CA, Kuhn V, Schneider E, Delling G, Muller R (2002) Bone strength at clinically relevant sites displays substantial heterogeneity and is best predicted from site-specific bone densitometry. J Bone Miner Res 17:162–171PubMedCrossRef
29.
Zurück zum Zitat Tingart MJ, Lehtinen J, Zurakowski D, Warner JJ, Apreleva M (2006) Proximal humeral fractures: regional differences in bone mineral density of the humeral head affect the fixation strength of cancellous screws. J Shoulder Elbow Surg 15:620–624PubMedCrossRef Tingart MJ, Lehtinen J, Zurakowski D, Warner JJ, Apreleva M (2006) Proximal humeral fractures: regional differences in bone mineral density of the humeral head affect the fixation strength of cancellous screws. J Shoulder Elbow Surg 15:620–624PubMedCrossRef
30.
Zurück zum Zitat Myers BS, Belmont PJ Jr., Richardson WJ, Yu JR, Harper KD, Nightingale RW (1996) The role of imaging and in situ biomechanical testing in assessing pedicle screw pull-out strength. Spine 21:1962–1968PubMedCrossRef Myers BS, Belmont PJ Jr., Richardson WJ, Yu JR, Harper KD, Nightingale RW (1996) The role of imaging and in situ biomechanical testing in assessing pedicle screw pull-out strength. Spine 21:1962–1968PubMedCrossRef
31.
Zurück zum Zitat Knop C, Lange U, Bastian L, Oeser M, Blauth M (2001) Biomechanical compression tests with a new implant for thoracolumbar vertebral body replacement. Eur Spine J 10:30–37PubMedCrossRef Knop C, Lange U, Bastian L, Oeser M, Blauth M (2001) Biomechanical compression tests with a new implant for thoracolumbar vertebral body replacement. Eur Spine J 10:30–37PubMedCrossRef
32.
Zurück zum Zitat Ali AM, Saleh M, Eastell R, Wigderowitz CA, Rigby AS, Yang L (2006) Influence of bone quality on the strength of internal and external fixation of tibial plateau fractures. J Orthop Res 24:2080–2086PubMedCrossRef Ali AM, Saleh M, Eastell R, Wigderowitz CA, Rigby AS, Yang L (2006) Influence of bone quality on the strength of internal and external fixation of tibial plateau fractures. J Orthop Res 24:2080–2086PubMedCrossRef
33.
Zurück zum Zitat Hogh J, Lund B, Lucht U (1981) Trochanteric and subtrochanteric fractures. The operative results in a prospective and comparative study of Ender nailing and McLaughlin Osteosynthesis. Acta Orthop Scand 52:639–643PubMedCrossRef Hogh J, Lund B, Lucht U (1981) Trochanteric and subtrochanteric fractures. The operative results in a prospective and comparative study of Ender nailing and McLaughlin Osteosynthesis. Acta Orthop Scand 52:639–643PubMedCrossRef
34.
Zurück zum Zitat Brostrom LA, Barrios C, Kronberg M, Stark A, Walheim G (1992) Clinical features and walking ability in the early postoperative period after treatment of trochanteric hip fractures. Results with special reference to fracture type and surgical treatment. Ann Chir Gynaecol 81:66–71PubMed Brostrom LA, Barrios C, Kronberg M, Stark A, Walheim G (1992) Clinical features and walking ability in the early postoperative period after treatment of trochanteric hip fractures. Results with special reference to fracture type and surgical treatment. Ann Chir Gynaecol 81:66–71PubMed
35.
Zurück zum Zitat Dalsgard J, Yde JR, Olsen AD (1987) [Pertrochanteric fractures. Comparison between 2 surgical methods of internal fixation]. Ugeskr Laeger 149:900–904PubMed Dalsgard J, Yde JR, Olsen AD (1987) [Pertrochanteric fractures. Comparison between 2 surgical methods of internal fixation]. Ugeskr Laeger 149:900–904PubMed
36.
Zurück zum Zitat Chapman MW, Bowman WE, Csongradi JJ, Day LJ, Trafton PG, Bovill EG Jr (1981) The use of Ender’s pins in extracapsular fractures of the hip. J Bone Joint Surg Am 63:14–28PubMed Chapman MW, Bowman WE, Csongradi JJ, Day LJ, Trafton PG, Bovill EG Jr (1981) The use of Ender’s pins in extracapsular fractures of the hip. J Bone Joint Surg Am 63:14–28PubMed
37.
Zurück zum Zitat Liem F. In R Marti, P Dunki Jacobs (ed) Proximal femoral fractures. Operative technique and complications. Medical Press Limited, London, pp 381–388 Liem F. In R Marti, P Dunki Jacobs (ed) Proximal femoral fractures. Operative technique and complications. Medical Press Limited, London, pp 381–388
38.
Zurück zum Zitat Juhn A, Krimerman J, Mendes DG (1988) Intertrochanteric fracture of the hip. Comparison of nail-plate fixation and Ender’s nailing. Arch Orthop Trauma Surg 107:136–139PubMedCrossRef Juhn A, Krimerman J, Mendes DG (1988) Intertrochanteric fracture of the hip. Comparison of nail-plate fixation and Ender’s nailing. Arch Orthop Trauma Surg 107:136–139PubMedCrossRef
39.
Zurück zum Zitat Nungu S, Olerud C, Rehnberg L (1991) Treatment of intertrochanteric fractures: comparison of Ender nails and sliding screw plates. J Orthop Trauma 5:452–457PubMedCrossRef Nungu S, Olerud C, Rehnberg L (1991) Treatment of intertrochanteric fractures: comparison of Ender nails and sliding screw plates. J Orthop Trauma 5:452–457PubMedCrossRef
40.
Zurück zum Zitat Sernbo I, Johnell O, Gentz CF, Nilsson JA (1988) Unstable intertrochanteric fractures of the hip. Treatment with Ender pins compared with a compression hip-screw. J Bone Joint Surg Am 70:1297–1303PubMed Sernbo I, Johnell O, Gentz CF, Nilsson JA (1988) Unstable intertrochanteric fractures of the hip. Treatment with Ender pins compared with a compression hip-screw. J Bone Joint Surg Am 70:1297–1303PubMed
41.
Zurück zum Zitat Adams CI, Robinson CM, Court-Brown CM, McQueen MM (2001) Prospective randomized controlled trial of an intramedullary nail versus dynamic screw and plate for intertrochanteric fractures of the femur. J Orthop Trauma 15:394–400PubMedCrossRef Adams CI, Robinson CM, Court-Brown CM, McQueen MM (2001) Prospective randomized controlled trial of an intramedullary nail versus dynamic screw and plate for intertrochanteric fractures of the femur. J Orthop Trauma 15:394–400PubMedCrossRef
42.
Zurück zum Zitat Ahrengart L, Tornkvist H, Fornander P, Thorngren KG, Pasanen L, Wahlstrom P, Honkonen S, Lindgren U (2002) A randomized study of the compression hip screw and Gamma nail in 426 fractures. Clin Orthop Relat Res:209–222 Ahrengart L, Tornkvist H, Fornander P, Thorngren KG, Pasanen L, Wahlstrom P, Honkonen S, Lindgren U (2002) A randomized study of the compression hip screw and Gamma nail in 426 fractures. Clin Orthop Relat Res:209–222
43.
Zurück zum Zitat Aune AK, Ekeland A, Odegaard B, Grogaard B, Alho A (1994) Gamma nail vs compression screw for trochanteric femoral fractures. 15 reoperations in a prospective, randomized study of 378 patients. Acta Orthop Scand 65:127–130PubMedCrossRef Aune AK, Ekeland A, Odegaard B, Grogaard B, Alho A (1994) Gamma nail vs compression screw for trochanteric femoral fractures. 15 reoperations in a prospective, randomized study of 378 patients. Acta Orthop Scand 65:127–130PubMedCrossRef
44.
Zurück zum Zitat Baumgaertner MR, Curtin SL, Lindskog DM (1998) Intramedullary versus extramedullary fixation for the treatment of intertrochanteric hip fractures. Clin Orthop Relat Res:87–94 Baumgaertner MR, Curtin SL, Lindskog DM (1998) Intramedullary versus extramedullary fixation for the treatment of intertrochanteric hip fractures. Clin Orthop Relat Res:87–94
45.
Zurück zum Zitat Parker MJ, Handoll HH (2005) Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Cochrane Database Syst Rev:CD000093 Parker MJ, Handoll HH (2005) Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Cochrane Database Syst Rev:CD000093
46.
Zurück zum Zitat Bridle SH, Patel AD, Bircher M, Calvert PT (1991) Fixation of intertrochanteric fractures of the femur. A randomised prospective comparison of the gamma nail and the dynamic hip screw. J Bone Joint Surg Br 73:330–334PubMed Bridle SH, Patel AD, Bircher M, Calvert PT (1991) Fixation of intertrochanteric fractures of the femur. A randomised prospective comparison of the gamma nail and the dynamic hip screw. J Bone Joint Surg Br 73:330–334PubMed
47.
Zurück zum Zitat Fornander P, Thorngren K-G, Tornqvist H, Ahrengart L, Lindgren U (1994) Swedish experience with the Gamma nail versus sliding hip screw in 209 randomised cases. Int J Orthp Trauma 4:118–122CrossRef Fornander P, Thorngren K-G, Tornqvist H, Ahrengart L, Lindgren U (1994) Swedish experience with the Gamma nail versus sliding hip screw in 209 randomised cases. Int J Orthp Trauma 4:118–122CrossRef
48.
Zurück zum Zitat Fritz T, Hiersemann K, Krieglstein C, Friedl W (1999) Prospective randomized comparison of gliding nail and gamma nail in the therapy of trochanteric fractures. Arch Orthop Trauma Surg 119:1–6PubMedCrossRef Fritz T, Hiersemann K, Krieglstein C, Friedl W (1999) Prospective randomized comparison of gliding nail and gamma nail in the therapy of trochanteric fractures. Arch Orthop Trauma Surg 119:1–6PubMedCrossRef
49.
Zurück zum Zitat Goldhagen PR, O’Connor DR, Schwarze D, Schwartz E (1994) A prospective comparative study of the compression hip screw and the gamma nail. J Orthop Trauma 8:367–372PubMedCrossRef Goldhagen PR, O’Connor DR, Schwarze D, Schwartz E (1994) A prospective comparative study of the compression hip screw and the gamma nail. J Orthop Trauma 8:367–372PubMedCrossRef
50.
Zurück zum Zitat Guyer P, Landolt M, Keller H, Eberle C (1991) [The Gamma Nail in per- and intertrochanteric femoral fractures-alternative or supplement to the dynamic hip screw? A prospective randomized study of 100 patients with per- and intertrochanteric femoral fractures in the surgical clinic of the City Hospital of Triemli, Zurich, September 1989 - June 1990]. Aktuelle Traumatol 21:242–249PubMed Guyer P, Landolt M, Keller H, Eberle C (1991) [The Gamma Nail in per- and intertrochanteric femoral fractures-alternative or supplement to the dynamic hip screw? A prospective randomized study of 100 patients with per- and intertrochanteric femoral fractures in the surgical clinic of the City Hospital of Triemli, Zurich, September 1989 - June 1990]. Aktuelle Traumatol 21:242–249PubMed
51.
Zurück zum Zitat Hardy DC, Descamps PY, Krallis P, Fabeck L, Smets P, Bertens CL, Delince PE (1998) Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures. A prospective, randomized study of one hundred patients. J Bone Joint Surg Am 80:618–630PubMed Hardy DC, Descamps PY, Krallis P, Fabeck L, Smets P, Bertens CL, Delince PE (1998) Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures. A prospective, randomized study of one hundred patients. J Bone Joint Surg Am 80:618–630PubMed
52.
Zurück zum Zitat Harrington P, Nihal A, Singhania AK, Howell FR (2002) Intramedullary hip screw versus sliding hip screw for unstable intertrochanteric femoral fractures in the elderly. Injury 33:23–28PubMedCrossRef Harrington P, Nihal A, Singhania AK, Howell FR (2002) Intramedullary hip screw versus sliding hip screw for unstable intertrochanteric femoral fractures in the elderly. Injury 33:23–28PubMedCrossRef
53.
Zurück zum Zitat Herrera A, Domingo LJ, Calvo A, Martinez A, Cuenca J (2002) A comparative study of trochanteric fractures treated with the Gamma nail or the proximal femoral nail. Int Orthop 26:365–369PubMedPubMedCentralCrossRef Herrera A, Domingo LJ, Calvo A, Martinez A, Cuenca J (2002) A comparative study of trochanteric fractures treated with the Gamma nail or the proximal femoral nail. Int Orthop 26:365–369PubMedPubMedCentralCrossRef
54.
Zurück zum Zitat Hoffman CW, Lynskey TG (1996) Intertrochanteric fractures of the femur: a randomized prospective comparison of the Gamma nail and the Ambi hip screw. Aust N Z J Surg 66:151–155PubMedCrossRef Hoffman CW, Lynskey TG (1996) Intertrochanteric fractures of the femur: a randomized prospective comparison of the Gamma nail and the Ambi hip screw. Aust N Z J Surg 66:151–155PubMedCrossRef
55.
Zurück zum Zitat Hoffmann R, Schmidmaier G, Schulz R, Schutz M, Sudkamp NP (1999) [Classic nail versus DHS. A prospective randomised study of fixation of trochanteric femur fractures]. Unfallchirurg 102:182–190PubMedCrossRef Hoffmann R, Schmidmaier G, Schulz R, Schutz M, Sudkamp NP (1999) [Classic nail versus DHS. A prospective randomised study of fixation of trochanteric femur fractures]. Unfallchirurg 102:182–190PubMedCrossRef
56.
Zurück zum Zitat \Kukla C, Heinz T, Berger G, Kwasny O, Rosenberger A, Vecsei V (1997) Gamma nail vs. dynamic hip screw in 120 patients over 60 years - a randomized trial. Acta Chirurgica Austriaca 29:290–293CrossRef \Kukla C, Heinz T, Berger G, Kwasny O, Rosenberger A, Vecsei V (1997) Gamma nail vs. dynamic hip screw in 120 patients over 60 years - a randomized trial. Acta Chirurgica Austriaca 29:290–293CrossRef
57.
Zurück zum Zitat Kuwabara H, Wada T, Minagi Y, Iwasaki T, Tsuji H (1998) [Compression hip screw and gamma nail for intertrochanteric fractures - Randomized prospective study]. Hokkaido Journal of Orthopaedics & Traumatology 40:29–33 Kuwabara H, Wada T, Minagi Y, Iwasaki T, Tsuji H (1998) [Compression hip screw and gamma nail for intertrochanteric fractures - Randomized prospective study]. Hokkaido Journal of Orthopaedics & Traumatology 40:29–33
58.
Zurück zum Zitat Leung KS, So WS, Shen WY, Hui PW (1992) Gamma nails and dynamic hip screws for peritrochanteric fractures. A randomised prospective study in elderly patients. J Bone Joint Surg Br 74:345–351PubMed Leung KS, So WS, Shen WY, Hui PW (1992) Gamma nails and dynamic hip screws for peritrochanteric fractures. A randomised prospective study in elderly patients. J Bone Joint Surg Br 74:345–351PubMed
59.
Zurück zum Zitat Madsen JE, Naess L, Aune AK, Alho A, Ekeland A, Stromsoe K (1998) Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the Gamma nail and compression hip screw. J Orthop Trauma 12:241–248PubMedCrossRef Madsen JE, Naess L, Aune AK, Alho A, Ekeland A, Stromsoe K (1998) Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the Gamma nail and compression hip screw. J Orthop Trauma 12:241–248PubMedCrossRef
60.
Zurück zum Zitat Marques Lopez F, Pelfort Lopez X, Barcia Casa O, Ramirez Valencia M, Leon Garcia Vao A, Ballester Soleda J (2002) Prospective, comparative, randomized study of the sliding screw and Gamma nail in the treatment of pertrochanteric fractures [Estudio prospectivo aleatorio comparativo del tornillo deslizante y el clavo gamma en el tratamiento de las fracturas pertrcantereas]. Revista de Ortopedia y Traumatologia 46:505–509 Marques Lopez F, Pelfort Lopez X, Barcia Casa O, Ramirez Valencia M, Leon Garcia Vao A, Ballester Soleda J (2002) Prospective, comparative, randomized study of the sliding screw and Gamma nail in the treatment of pertrochanteric fractures [Estudio prospectivo aleatorio comparativo del tornillo deslizante y el clavo gamma en el tratamiento de las fracturas pertrcantereas]. Revista de Ortopedia y Traumatologia 46:505–509
61.
Zurück zum Zitat O’Brien PJ, Meek RN, Blachut PA, Broekhuyse HM, Sabharwal S (1995) Fixation of intertrochanteric hip fractures: gamma nail versus dynamic hip screw. A randomized, prospective study. Can J Surg 38:516–520PubMed O’Brien PJ, Meek RN, Blachut PA, Broekhuyse HM, Sabharwal S (1995) Fixation of intertrochanteric hip fractures: gamma nail versus dynamic hip screw. A randomized, prospective study. Can J Surg 38:516–520PubMed
62.
Zurück zum Zitat Pajarinen J, Lindahl J, Michelsson O, Savolainen V, Hirvensalo E (2005) Pertrochanteric femoral fractures treated with a dynamic hip screw or a proximal femoral nail. A randomised study comparing post-operative rehabilitation. J Bone Joint Surg Br 87:76–81PubMedCrossRef Pajarinen J, Lindahl J, Michelsson O, Savolainen V, Hirvensalo E (2005) Pertrochanteric femoral fractures treated with a dynamic hip screw or a proximal femoral nail. A randomised study comparing post-operative rehabilitation. J Bone Joint Surg Br 87:76–81PubMedCrossRef
63.
Zurück zum Zitat Park SR, Kang JS, Kim HS, Lee WH, Kim YH (1998) Treatment of intertrochanteric fracture with the Gamma AP locking nail or by a compression hip screw-a randomised prospective trial. Int Orthop 22:157–160PubMedPubMedCentralCrossRef Park SR, Kang JS, Kim HS, Lee WH, Kim YH (1998) Treatment of intertrochanteric fracture with the Gamma AP locking nail or by a compression hip screw-a randomised prospective trial. Int Orthop 22:157–160PubMedPubMedCentralCrossRef
64.
Zurück zum Zitat Pelet S, Arlettaz Y, Chevalley F (2001) [Osteosynthesis of per- and subtrochanteric fractures by blade plate versus gamma nail. A randomized prospective study]. Swiss Surg 7:126–133PubMedCrossRef Pelet S, Arlettaz Y, Chevalley F (2001) [Osteosynthesis of per- and subtrochanteric fractures by blade plate versus gamma nail. A randomized prospective study]. Swiss Surg 7:126–133PubMedCrossRef
65.
Zurück zum Zitat Radford PJ, Needoff M, Webb JK (1993) A prospective randomised comparison of the dynamic hip screw and the gamma locking nail. J Bone Joint Surg Br 75:789–793PubMed Radford PJ, Needoff M, Webb JK (1993) A prospective randomised comparison of the dynamic hip screw and the gamma locking nail. J Bone Joint Surg Br 75:789–793PubMed
66.
Zurück zum Zitat Saudan M, Lubbeke A, Sadowski C, Riand N, Stern R, Hoffmeyer P (2002) Pertrochanteric fractures: is there an advantage to an intramedullary nail?: a randomized, prospective study of 206 patients comparing the dynamic hip screw and proximal femoral nail. J Orthop Trauma 16:386–393PubMedCrossRef Saudan M, Lubbeke A, Sadowski C, Riand N, Stern R, Hoffmeyer P (2002) Pertrochanteric fractures: is there an advantage to an intramedullary nail?: a randomized, prospective study of 206 patients comparing the dynamic hip screw and proximal femoral nail. J Orthop Trauma 16:386–393PubMedCrossRef
67.
Zurück zum Zitat Sadowski C, Lubbeke A, Saudan M, Riand N, Stern R, Hoffmeyer P (2002) Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95 degrees screw-plate: a prospective, randomized study. J Bone Joint Surg Am 84-A:372–381PubMed Sadowski C, Lubbeke A, Saudan M, Riand N, Stern R, Hoffmeyer P (2002) Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95 degrees screw-plate: a prospective, randomized study. J Bone Joint Surg Am 84-A:372–381PubMed
68.
Zurück zum Zitat Utrilla AL, Reig JS, Munoz FM, Tufanisco CB (2005) Trochanteric gamma nail and compression hip screw for trochanteric fractures: a randomized, prospective, comparative study in 210 elderly patients with a new design of the gamma nail. J Orthop Trauma 19:229–233PubMedCrossRef Utrilla AL, Reig JS, Munoz FM, Tufanisco CB (2005) Trochanteric gamma nail and compression hip screw for trochanteric fractures: a randomized, prospective, comparative study in 210 elderly patients with a new design of the gamma nail. J Orthop Trauma 19:229–233PubMedCrossRef
69.
Zurück zum Zitat Buciuto R, Hammer R (2001) RAB-plate versus sliding hip screw for unstable trochanteric hip fractures: stability of the fixation and modes of failure-radiographic analysis of 218 fractures. J Trauma 50:545–550PubMedCrossRef Buciuto R, Hammer R (2001) RAB-plate versus sliding hip screw for unstable trochanteric hip fractures: stability of the fixation and modes of failure-radiographic analysis of 218 fractures. J Trauma 50:545–550PubMedCrossRef
70.
Zurück zum Zitat Davis TR, Sher JL, Checketts RG, Porter BB (1988) Intertrochanteric fractures of the femur: a prospective study comparing the use of the Kuntscher-Y nail and a sliding hip screw. Injury 19:421–426PubMedCrossRef Davis TR, Sher JL, Checketts RG, Porter BB (1988) Intertrochanteric fractures of the femur: a prospective study comparing the use of the Kuntscher-Y nail and a sliding hip screw. Injury 19:421–426PubMedCrossRef
71.
Zurück zum Zitat Janzing HM, Houben BJ, Brandt SE, Chhoeurn V, Lefever S, Broos P, Reynders P, Vanderschot P (2002) The Gotfried PerCutaneous Compression Plate versus the Dynamic Hip Screw in the treatment of pertrochanteric hip fractures: minimal invasive treatment reduces operative time and postoperative pain. J Trauma 52:293–298PubMed Janzing HM, Houben BJ, Brandt SE, Chhoeurn V, Lefever S, Broos P, Reynders P, Vanderschot P (2002) The Gotfried PerCutaneous Compression Plate versus the Dynamic Hip Screw in the treatment of pertrochanteric hip fractures: minimal invasive treatment reduces operative time and postoperative pain. J Trauma 52:293–298PubMed
72.
Zurück zum Zitat Kosygan KP, Mohan R, Newman RJ (2002) The Gotfried percutaneous compression plate compared with the conventional classic hip screw for the fixation of intertrochanteric fractures of the hip. J Bone Joint Surg Br 84:19–22PubMedCrossRef Kosygan KP, Mohan R, Newman RJ (2002) The Gotfried percutaneous compression plate compared with the conventional classic hip screw for the fixation of intertrochanteric fractures of the hip. J Bone Joint Surg Br 84:19–22PubMedCrossRef
73.
Zurück zum Zitat Lizaur Utrilla AL, Cebrian Gomez R, Sebastia Forcada E (1998) Compression screw plate or monoblock nail-plate in trochanteric fractures of the femur in the elderly [Tornillo-placa a compresion o clavo-placa monobloque en las fracturas trocantereas del femur del anciano]. Revista de Ortopedia y Traumatologia 42:368–373 Lizaur Utrilla AL, Cebrian Gomez R, Sebastia Forcada E (1998) Compression screw plate or monoblock nail-plate in trochanteric fractures of the femur in the elderly [Tornillo-placa a compresion o clavo-placa monobloque en las fracturas trocantereas del femur del anciano]. Revista de Ortopedia y Traumatologia 42:368–373
74.
Zurück zum Zitat Miedel R, Ponzer S, Tornkvist H, Soderqvist A, Tidermark J (2005) The standard Gamma nail or the Medoff sliding plate for unstable trochanteric and subtrochanteric fractures. A randomised, controlled trial. J Bone Joint Surg Br 87:68–75PubMed Miedel R, Ponzer S, Tornkvist H, Soderqvist A, Tidermark J (2005) The standard Gamma nail or the Medoff sliding plate for unstable trochanteric and subtrochanteric fractures. A randomised, controlled trial. J Bone Joint Surg Br 87:68–75PubMed
75.
Zurück zum Zitat Moroni A, Faldini C, Pegreffi F, Hoang-Kim A, Vannini F, Giannini S (2005) Dynamic hip screw compared with external fixation for treatment of osteoporotic pertrochanteric fractures. A prospective, randomized study. J Bone Joint Surg Am 87:753–759PubMedCrossRef Moroni A, Faldini C, Pegreffi F, Hoang-Kim A, Vannini F, Giannini S (2005) Dynamic hip screw compared with external fixation for treatment of osteoporotic pertrochanteric fractures. A prospective, randomized study. J Bone Joint Surg Am 87:753–759PubMedCrossRef
76.
Zurück zum Zitat Olsson O, Ceder L, Hauggaard A (2001) Femoral shortening in intertrochanteric fractures. A comparison between the Medoff sliding plate and the compression hip screw. J Bone Joint Surg Br 83:572–578PubMedCrossRef Olsson O, Ceder L, Hauggaard A (2001) Femoral shortening in intertrochanteric fractures. A comparison between the Medoff sliding plate and the compression hip screw. J Bone Joint Surg Br 83:572–578PubMedCrossRef
77.
Zurück zum Zitat Pitsaer E, Samuel AW (1993) Functional outcome after intertrochanteric fractures of the femur: does the implant matter? A prospective study of 100 consecutive cases. Injury 24:35–36PubMedCrossRef Pitsaer E, Samuel AW (1993) Functional outcome after intertrochanteric fractures of the femur: does the implant matter? A prospective study of 100 consecutive cases. Injury 24:35–36PubMedCrossRef
78.
Zurück zum Zitat Vossinakis IC, Badras LS (2002) The external fixator compared with the sliding hip screw for pertrochanteric fractures of the femur. J Bone Joint Surg Br 84:23–29PubMedCrossRef Vossinakis IC, Badras LS (2002) The external fixator compared with the sliding hip screw for pertrochanteric fractures of the femur. J Bone Joint Surg Br 84:23–29PubMedCrossRef
79.
Zurück zum Zitat Lunsjo K, Ceder L, Thorngren KG, Skytting B, Tidermark J, Berntson PO, Allvin I, Norberg S, Hjalmars K, Larsson S, Knebel R, Hauggaard A, Stigsson L (2001) Extramedullary fixation of 569 unstable intertrochanteric fractures: a randomized multicenter trial of the Medoff sliding plate versus three other screw-plate systems. Acta Orthop Scand 72:133–140PubMedCrossRef Lunsjo K, Ceder L, Thorngren KG, Skytting B, Tidermark J, Berntson PO, Allvin I, Norberg S, Hjalmars K, Larsson S, Knebel R, Hauggaard A, Stigsson L (2001) Extramedullary fixation of 569 unstable intertrochanteric fractures: a randomized multicenter trial of the Medoff sliding plate versus three other screw-plate systems. Acta Orthop Scand 72:133–140PubMedCrossRef
80.
Zurück zum Zitat Lunsjo K, Ceder L, Tidermark J, Hamberg P, Larsson BE, Ragnarsson B, Knebel RW, Allvin I, Hjalmars K, Norberg S, Fornander P, Hauggaard A, Stigsson L (1999) Extramedullary fixation of 107 subtrochanteric fractures: a randomized multicenter trial of the Medoff sliding plate versus 3 other screw-plate systems. Acta Orthop Scand 70:459–466PubMedCrossRef Lunsjo K, Ceder L, Tidermark J, Hamberg P, Larsson BE, Ragnarsson B, Knebel RW, Allvin I, Hjalmars K, Norberg S, Fornander P, Hauggaard A, Stigsson L (1999) Extramedullary fixation of 107 subtrochanteric fractures: a randomized multicenter trial of the Medoff sliding plate versus 3 other screw-plate systems. Acta Orthop Scand 70:459–466PubMedCrossRef
81.
Zurück zum Zitat Parker MJ, Handoll HH (2006) Extramedullary fixation implants and external fixators for extracapsular hip fractures in adults. Cochrane Database Syst Rev:CD000339 Parker MJ, Handoll HH (2006) Extramedullary fixation implants and external fixators for extracapsular hip fractures in adults. Cochrane Database Syst Rev:CD000339
82.
Zurück zum Zitat Schipper IB, Steyerberg EW, Castelein RM, van der Heijden FH, den Hoed PT, Kerver AJ, van Vugt AB (2004) Treatment of unstable trochanteric fractures. Randomised comparison of the gamma nail and the proximal femoral nail. J Bone Joint Surg Br 86:86–94PubMed Schipper IB, Steyerberg EW, Castelein RM, van der Heijden FH, den Hoed PT, Kerver AJ, van Vugt AB (2004) Treatment of unstable trochanteric fractures. Randomised comparison of the gamma nail and the proximal femoral nail. J Bone Joint Surg Br 86:86–94PubMed
83.
Zurück zum Zitat Butt MS, Krikler SJ, Nafie S, Ali MS (1995) Comparison of dynamic hip screw and gamma nail: a prospective, randomized, controlled trial. Injury 26:615–618PubMedCrossRef Butt MS, Krikler SJ, Nafie S, Ali MS (1995) Comparison of dynamic hip screw and gamma nail: a prospective, randomized, controlled trial. Injury 26:615–618PubMedCrossRef
84.
Zurück zum Zitat Dalen N, Jacobsson B, Eriksson PA (1988) A comparison of nail-plate fixation and Ender’s nailing in pertrochanteric fractures. J Trauma 28:405–406PubMedCrossRef Dalen N, Jacobsson B, Eriksson PA (1988) A comparison of nail-plate fixation and Ender’s nailing in pertrochanteric fractures. J Trauma 28:405–406PubMedCrossRef
85.
Zurück zum Zitat Hayward SJ, Lowe LW, Tzevelekos S (1983) Intertrochanteric fractures: a comparison between fixation with a two-piece nail plate and Ender’s nails. Int Orthop 7:153–158PubMedCrossRef Hayward SJ, Lowe LW, Tzevelekos S (1983) Intertrochanteric fractures: a comparison between fixation with a two-piece nail plate and Ender’s nails. Int Orthop 7:153–158PubMedCrossRef
86.
Zurück zum Zitat Widman J, Isacson J (2002) Primary bone grafting does not improve the results in severely displaced distal radius fractures. Int Orthop 26:20–22PubMedPubMedCentralCrossRef Widman J, Isacson J (2002) Primary bone grafting does not improve the results in severely displaced distal radius fractures. Int Orthop 26:20–22PubMedPubMedCentralCrossRef
87.
Zurück zum Zitat McQueen MM, Hajducka C, Court-Brown CM (1996) Redisplaced unstable fractures of the distal radius: a prospective randomised comparison of four methods of treatment. J Bone Joint Surg Br 78:404–409PubMed McQueen MM, Hajducka C, Court-Brown CM (1996) Redisplaced unstable fractures of the distal radius: a prospective randomised comparison of four methods of treatment. J Bone Joint Surg Br 78:404–409PubMed
88.
Zurück zum Zitat Sanchez-Sotelo J, Munuera L, Madero R (2000) Treatment of fractures of the distal radius with a remodellable bone cement: a prospective, randomised study using Norian SRS. J Bone Joint Surg Br 82:856–863PubMedCrossRef Sanchez-Sotelo J, Munuera L, Madero R (2000) Treatment of fractures of the distal radius with a remodellable bone cement: a prospective, randomised study using Norian SRS. J Bone Joint Surg Br 82:856–863PubMedCrossRef
89.
Zurück zum Zitat McQueen MM (1998) Redisplaced unstable fractures of the distal radius. A randomised, prospective study of bridging versus non-bridging external fixation. J Bone Joint Surg Br 80:665–669PubMedCrossRef McQueen MM (1998) Redisplaced unstable fractures of the distal radius. A randomised, prospective study of bridging versus non-bridging external fixation. J Bone Joint Surg Br 80:665–669PubMedCrossRef
90.
Zurück zum Zitat Handoll HH, Madhok R (2003) Surgical interventions for treating distal radial fractures in adults. Cochrane Database Syst Rev:CD003209 Handoll HH, Madhok R (2003) Surgical interventions for treating distal radial fractures in adults. Cochrane Database Syst Rev:CD003209
91.
Zurück zum Zitat Rodriguez-Merchan EC (1997) Plaster cast versus percutaneous pin fixation for comminuted fractures of the distal radius in patients between 46 and 65 years of age. J Orthop Trauma 11:212–217PubMedCrossRef Rodriguez-Merchan EC (1997) Plaster cast versus percutaneous pin fixation for comminuted fractures of the distal radius in patients between 46 and 65 years of age. J Orthop Trauma 11:212–217PubMedCrossRef
92.
Zurück zum Zitat Young CF, Nanu AM, Checketts RG (2003) Seven-year outcome following Colles’ type distal radial fracture. A comparison of two treatment methods. J Hand Surg [Br] 28:422–426CrossRef Young CF, Nanu AM, Checketts RG (2003) Seven-year outcome following Colles’ type distal radial fracture. A comparison of two treatment methods. J Hand Surg [Br] 28:422–426CrossRef
93.
Zurück zum Zitat US Food and Drug Administration - Center for Devices and Radiological Health. Norian(R) SRS(R) Cement. P970010. Issued 23–12–1998. Accessed 7/7/06 US Food and Drug Administration - Center for Devices and Radiological Health. Norian(R) SRS(R) Cement. P970010. Issued 23–12–1998. Accessed 7/7/06
94.
Zurück zum Zitat Pring DJ, Barber L, Williams DJ (1988) Bipolar fixation of fractures of the distal end of the radius: a comparative study. Injury 19:145–148PubMedCrossRef Pring DJ, Barber L, Williams DJ (1988) Bipolar fixation of fractures of the distal end of the radius: a comparative study. Injury 19:145–148PubMedCrossRef
95.
Zurück zum Zitat Stein H, Volpin G, Horesh Z, Hoerer D (1990) Cast or external fixation for fracture of the distal radius. A prospective study of 126 cases. Acta Orthop Scand 61:453–456PubMedCrossRef Stein H, Volpin G, Horesh Z, Hoerer D (1990) Cast or external fixation for fracture of the distal radius. A prospective study of 126 cases. Acta Orthop Scand 61:453–456PubMedCrossRef
96.
Zurück zum Zitat Abbaszadegan H, Jonsson U (1990) External fixation or plaster cast for severely displaced Colles’ fractures? Prospective 1-year study of 46 patients. Acta Orthop Scand 61:528–530PubMedCrossRef Abbaszadegan H, Jonsson U (1990) External fixation or plaster cast for severely displaced Colles’ fractures? Prospective 1-year study of 46 patients. Acta Orthop Scand 61:528–530PubMedCrossRef
97.
Zurück zum Zitat Howard PW, Stewart HD, Hind RE, Burke FD (1989) External fixation or plaster for severely displaced comminuted Colles’ fractures? A prospective study of anatomical and functional results. J Bone Joint Surg Br 71:68–73PubMed Howard PW, Stewart HD, Hind RE, Burke FD (1989) External fixation or plaster for severely displaced comminuted Colles’ fractures? A prospective study of anatomical and functional results. J Bone Joint Surg Br 71:68–73PubMed
98.
Zurück zum Zitat Lagerstrom C, Nordgren B, Olerud C (1999) Evaluation of grip strength measurements after Colles’ fracture: a methodological study. Scand J Rehabil Med 31:49–54PubMedCrossRef Lagerstrom C, Nordgren B, Olerud C (1999) Evaluation of grip strength measurements after Colles’ fracture: a methodological study. Scand J Rehabil Med 31:49–54PubMedCrossRef
99.
Zurück zum Zitat Raskin KB, Melone CP Jr (1993) Unstable articular fractures of the distal radius. Comparative techniques of ligamentotaxis. Orthop Clin North Am 24:275–286PubMed Raskin KB, Melone CP Jr (1993) Unstable articular fractures of the distal radius. Comparative techniques of ligamentotaxis. Orthop Clin North Am 24:275–286PubMed
100.
Zurück zum Zitat Hutchinson DT, Strenz GO, Cautilli RA (1995) Pins and plaster vs external fixation in the treatment of unstable distal radial fractures. A randomized prospective study. J Hand Surg [Br] 20:365–372CrossRef Hutchinson DT, Strenz GO, Cautilli RA (1995) Pins and plaster vs external fixation in the treatment of unstable distal radial fractures. A randomized prospective study. J Hand Surg [Br] 20:365–372CrossRef
101.
Zurück zum Zitat Sommerkamp TG, Seeman M, Silliman J, Jones A, Patterson S, Walker J, Semmler M, Browne R, Ezaki M (1994) Dynamic external fixation of unstable fractures of the distal part of the radius. A prospective, randomized comparison with static external fixation. J Bone Joint Surg Am 76:1149–1161PubMed Sommerkamp TG, Seeman M, Silliman J, Jones A, Patterson S, Walker J, Semmler M, Browne R, Ezaki M (1994) Dynamic external fixation of unstable fractures of the distal part of the radius. A prospective, randomized comparison with static external fixation. J Bone Joint Surg Am 76:1149–1161PubMed
102.
Zurück zum Zitat Horne JG, Devane P, Purdie G (1990) A prospective randomized trial of external fixation and plaster cast immobilization in the treatment of distal radial fractures. J Orthop Trauma 4:30–34PubMedCrossRef Horne JG, Devane P, Purdie G (1990) A prospective randomized trial of external fixation and plaster cast immobilization in the treatment of distal radial fractures. J Orthop Trauma 4:30–34PubMedCrossRef
103.
Zurück zum Zitat Merchan EC, Breton AF, Galindo E, Peinado JF, Beltran J (1992) Plaster cast versus Clyburn external fixation for fractures of the distal radius in patients under 45 years of age. Orthop Rev 21:1203–1209PubMed Merchan EC, Breton AF, Galindo E, Peinado JF, Beltran J (1992) Plaster cast versus Clyburn external fixation for fractures of the distal radius in patients under 45 years of age. Orthop Rev 21:1203–1209PubMed
104.
Zurück zum Zitat Lenoble E, Dumontier C, Goutallier D, Apoil A (1995) Fracture of the distal radius. A prospective comparison between trans-styloid and Kapandji fixations. J Bone Joint Surg Br 77:562–567PubMed Lenoble E, Dumontier C, Goutallier D, Apoil A (1995) Fracture of the distal radius. A prospective comparison between trans-styloid and Kapandji fixations. J Bone Joint Surg Br 77:562–567PubMed
105.
Zurück zum Zitat Gupta R, Raheja A, Modi U (1999) Colles’ fracture: management by percutaneous crossed-pin fixation versus plaster of Paris cast immobilization. Orthopedics 22:680–682PubMed Gupta R, Raheja A, Modi U (1999) Colles’ fracture: management by percutaneous crossed-pin fixation versus plaster of Paris cast immobilization. Orthopedics 22:680–682PubMed
106.
Zurück zum Zitat Shankar NS, Craxford AD (1992) Comminuted Colles’ fractures: a prospective trial of management. J R Coll Surg Edinb 37:199–202PubMed Shankar NS, Craxford AD (1992) Comminuted Colles’ fractures: a prospective trial of management. J R Coll Surg Edinb 37:199–202PubMed
107.
Zurück zum Zitat Fikry T, Fadili M, Harfaoui A, Dkhissi M, Zryouil B (1998) [Metaphysis fracture of the distal radius: Kapandji’s or Py’s pinning?]. Ann Chir Main Memb Super 17:31–40PubMedCrossRef Fikry T, Fadili M, Harfaoui A, Dkhissi M, Zryouil B (1998) [Metaphysis fracture of the distal radius: Kapandji’s or Py’s pinning?]. Ann Chir Main Memb Super 17:31–40PubMedCrossRef
108.
Zurück zum Zitat Schmalholz A (1989) Bone cement for redislocated Colles’ fracture. A prospective comparison with closed treatment. Acta Orthop Scand 60:212–217PubMedCrossRef Schmalholz A (1989) Bone cement for redislocated Colles’ fracture. A prospective comparison with closed treatment. Acta Orthop Scand 60:212–217PubMedCrossRef
109.
Zurück zum Zitat Kapoor H, Agarwal A, Dhaon BK (2000) Displaced intra-articular fractures of distal radius: a comparative evaluation of results following closed reduction, external fixation and open reduction with internal fixation. Injury 31:75–79PubMedCrossRef Kapoor H, Agarwal A, Dhaon BK (2000) Displaced intra-articular fractures of distal radius: a comparative evaluation of results following closed reduction, external fixation and open reduction with internal fixation. Injury 31:75–79PubMedCrossRef
110.
Zurück zum Zitat Rommens PM, Heyvaert G (1993) [Conservative treatment of subcapital humerus fractures. A comparative study of the classical Desault bandage and the new Gilchrist bandage]. Unfallchirurgie 19:114–118PubMedCrossRef Rommens PM, Heyvaert G (1993) [Conservative treatment of subcapital humerus fractures. A comparative study of the classical Desault bandage and the new Gilchrist bandage]. Unfallchirurgie 19:114–118PubMedCrossRef
111.
Zurück zum Zitat Zyto K, Ahrengart L, Sperber A, Tornkvist H (1997) Treatment of displaced proximal humeral fractures in elderly patients. J Bone Joint Surg Br 79:412–417PubMedCrossRef Zyto K, Ahrengart L, Sperber A, Tornkvist H (1997) Treatment of displaced proximal humeral fractures in elderly patients. J Bone Joint Surg Br 79:412–417PubMedCrossRef
112.
Zurück zum Zitat Kristiansen B, Kofoed H (1988) Transcutaneous reduction and external fixation of displaced fractures of the proximal humerus. A controlled clinical trial. J Bone Joint Surg Br 70:821–824PubMed Kristiansen B, Kofoed H (1988) Transcutaneous reduction and external fixation of displaced fractures of the proximal humerus. A controlled clinical trial. J Bone Joint Surg Br 70:821–824PubMed
Metadaten
Titel
Influence of osteoporosis on fracture fixation - a systematic literature review
verfasst von
J. Goldhahn
N. Suhm
S. Goldhahn
M. Blauth
B. Hanson
Publikationsdatum
01.06.2008
Verlag
Springer London
Erschienen in
Osteoporosis International / Ausgabe 6/2008
Print ISSN: 0937-941X
Elektronische ISSN: 1433-2965
DOI
https://doi.org/10.1007/s00198-007-0515-9

Weitere Artikel der Ausgabe 6/2008

Osteoporosis International 6/2008 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.