Purpose

Myocardial perfusion with PET/CT has advantages over conventional SPECT. We describe our initial European experience using 82Rubidium-PET/CT, as part of a clinical myocardial perfusion service.

Methods

We studied the first 100 patients (64 male; 36 female, mean age = 60: SD +/−12.5y, mean body mass index = 30: SD +/−6.9kg/m 2 ) who underwent 82Rubidium cardiac PET/CT in our institution. Thirty patients had recently undergone coronary angiography. Patients underwent imaging during adenosine infusion and at rest. Images were acquired over 5 minutes using a GE-PET/CT instrument. Image quality was described as good, adequate or inadequate. Images were reported patient-by-patient by a minimum of five nuclear medicine physicians. A segment-by-segment analysis (17-segment model) was also performed.

Results

Image quality was good in 77%, adequate 23% and inadequate 0%. There was no statistical difference in image quality between obese and non-obese patients (Fisher’s exact test, p = 0.2864). 59% had normal perfusion studies, 29% had inducible ischaemia, 12% had myocardial infarction (11% with super added ischaemia). There was reduced 82Rubidium uptake in 132/1700 segments during stress. There was reduced 82Rubidium uptake at rest in 42/1700 segments. The 82Rubidium PET/CT findings were consistent with the angiographic findings in 28/30 cases.

Conclusion

We show that, even from initial use of 82Rubidium, it is possible to perform myocardial perfusion studies quickly with good image quality, even in the obese. The PET findings correlated well in the third of the cases where angiography was available. As such, 82Rubidium cardiac PET/CT is likely to be an exciting addition to the European nuclear physician/ cardiologist’s radionuclide imaging arsenal.
Literatur
1.
Zurück zum Zitat Cuocolo A, Acampa W, Inbriaco M, De Luca N, Iovino GL, Salvatore MG. The many ways to myocardial perfusion imaging. Q J Nucl Med Mol Imaging 2005;49:4–18.PubMed Cuocolo A, Acampa W, Inbriaco M, De Luca N, Iovino GL, Salvatore MG. The many ways to myocardial perfusion imaging. Q J Nucl Med Mol Imaging 2005;49:4–18.PubMed
2.
3.
Zurück zum Zitat Di Carli MF, Dorbala S. Integrated PET/CT for cardiac imaging. Q J Nucl Med Mol Imaging 2006;50:44–52.PubMed Di Carli MF, Dorbala S. Integrated PET/CT for cardiac imaging. Q J Nucl Med Mol Imaging 2006;50:44–52.PubMed
4.
Zurück zum Zitat Machac J, Bacharach SL, Bateman TM, Bax JJ, Beanlands R, Bengel F, et al. Quality assurance committee of the american society of nuclear cardiology. Positron emission tomography myocardial perfusion and glucose metabolism imaging. J Nucl Cardiol 2006;13:e121–51.PubMedCrossRef Machac J, Bacharach SL, Bateman TM, Bax JJ, Beanlands R, Bengel F, et al. Quality assurance committee of the american society of nuclear cardiology. Positron emission tomography myocardial perfusion and glucose metabolism imaging. J Nucl Cardiol 2006;13:e121–51.PubMedCrossRef
5.
Zurück zum Zitat Gould KL, Goldstein RA, Mullani NA, Kirkeeide RL, Wong WH, Tewson TJ, et al. Noninvasive assessment of coronary stenoses by myocardial perfusion imaging during pharmacologic coronary vasodilation. VIII. Clinical feasibility of positron cardiac imaging without a cyclotron using generator-produced rubidium-82. J Am Coll Cardiol 1986;7:775–89.PubMedCrossRef Gould KL, Goldstein RA, Mullani NA, Kirkeeide RL, Wong WH, Tewson TJ, et al. Noninvasive assessment of coronary stenoses by myocardial perfusion imaging during pharmacologic coronary vasodilation. VIII. Clinical feasibility of positron cardiac imaging without a cyclotron using generator-produced rubidium-82. J Am Coll Cardiol 1986;7:775–89.PubMedCrossRef
6.
Zurück zum Zitat Cerqueira MD, Weissman NJ, Dilsizian V, Jacobs AK, Kaul S, Laskey WK, et al. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac imaging committee of the council on clinical cardiology of the American heart association. Circulation 2002;105:539–42.PubMedCrossRef Cerqueira MD, Weissman NJ, Dilsizian V, Jacobs AK, Kaul S, Laskey WK, et al. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac imaging committee of the council on clinical cardiology of the American heart association. Circulation 2002;105:539–42.PubMedCrossRef
7.
Zurück zum Zitat Brown KA, Heller GV, Landin RS, Shaw LJ, Beller GA, Pasquale MJ, et al. Early dipyridamole (99m)Tc-sestamibi single photon emission computed tomographic imaging 2 to 4 days after acute myocardial infarction predicts in-hospital and postdischarge cardiac events. Circulation 1999;100:2060–66.PubMed Brown KA, Heller GV, Landin RS, Shaw LJ, Beller GA, Pasquale MJ, et al. Early dipyridamole (99m)Tc-sestamibi single photon emission computed tomographic imaging 2 to 4 days after acute myocardial infarction predicts in-hospital and postdischarge cardiac events. Circulation 1999;100:2060–66.PubMed
8.
Zurück zum Zitat Stabin MG, Stubbs JB, Toohey RE. Radiation dose estimates for radiopharmaceuticals-NUREG/CR-6345. Oak Ridge Institute of Science and Education, Oak Ridge, Tennessee; 1996. Stabin MG, Stubbs JB, Toohey RE. Radiation dose estimates for radiopharmaceuticals-NUREG/CR-6345. Oak Ridge Institute of Science and Education, Oak Ridge, Tennessee; 1996.
9.
Zurück zum Zitat International Commission on Radiological Protection (1998) Radiation Dose to Patients from radiopharmaceuticals publication 80. Addendum 2 to IRCP 53. Also includes Addendum 1 to IRCP Publication 72. Ann ICRP 28(3):116. International Commission on Radiological Protection (1998) Radiation Dose to Patients from radiopharmaceuticals publication 80. Addendum 2 to IRCP 53. Also includes Addendum 1 to IRCP Publication 72. Ann ICRP 28(3):116.
10.
Zurück zum Zitat Schleipman AR, Castronovo FP Jr, Di Carli MF, Dorbala S. Occupational radiation dose associated with Rb-82 myocardial perfusion positron emission tomography imaging. J Nucl Cardiol 2006;13:378–84.PubMedCrossRef Schleipman AR, Castronovo FP Jr, Di Carli MF, Dorbala S. Occupational radiation dose associated with Rb-82 myocardial perfusion positron emission tomography imaging. J Nucl Cardiol 2006;13:378–84.PubMedCrossRef
11.
Zurück zum Zitat Administration of Radioactive Substances Advisory Committee. Notes for guidance on clinical administration of radiopharmaceuticals and use of sealed sources. Chilton, UK: National Radiological Protection Board; 2006;36. Administration of Radioactive Substances Advisory Committee. Notes for guidance on clinical administration of radiopharmaceuticals and use of sealed sources. Chilton, UK: National Radiological Protection Board; 2006;36.
12.
Zurück zum Zitat Kaufmann PA, Camici PG. Myocardial blood flow measurement by PET: Technical aspects and clinical applications. J Nucl Med 2005;46:75–86.PubMed Kaufmann PA, Camici PG. Myocardial blood flow measurement by PET: Technical aspects and clinical applications. J Nucl Med 2005;46:75–86.PubMed
13.
Zurück zum Zitat El Fakhri G, Sitek A, Guerin B, Kijewski MF, Di Carli MF, Moore SC. Quantitative dynamic cardiac 82Rb PET using generalized factor and compartment analyses. J Nucl Med 2005;46:1264–71.PubMed El Fakhri G, Sitek A, Guerin B, Kijewski MF, Di Carli MF, Moore SC. Quantitative dynamic cardiac 82Rb PET using generalized factor and compartment analyses. J Nucl Med 2005;46:1264–71.PubMed
Metadaten
Titel
Cardiac 82rubidium PET/CT: initial European experience
verfasst von
Ashley M. Groves
Marie-Elsya Speechly-Dick
John C. Dickson
Irfan Kayani
Raymondo Endozo
Patty Blanchard
Manu Shastry
Elizabeth Prvulovich
Wendy A. Waddington
Simona Ben-Haim
Jamshed B. Bomanji
Jean R. McEwan
Peter J. Ell
Publikationsdatum
01.12.2007
Verlag
Springer-Verlag
Erschienen in
European Journal of Nuclear Medicine and Molecular Imaging / Ausgabe 12/2007
Print ISSN: 1619-7070
Elektronische ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-007-0537-8

Weitere Artikel der Ausgabe 12/2007

European Journal of Nuclear Medicine and Molecular Imaging 12/2007 Zur Ausgabe