Skip to main content
Erschienen in: European Journal of Nuclear Medicine and Molecular Imaging 6/2019

13.11.2018 | Original Article

Comparing diagnostic accuracy of 18F-FDG-PET/CT, contrast enhanced CT and combined imaging in patients with suspected vascular graft infections

verfasst von: Lars Husmann, Martin W. Huellner, Bruno Ledergerber, Alexia Anagnostopoulos, Paul Stolzmann, Bert-Ram Sah, Irene A. Burger, Zoran Rancic, Barbara Hasse, and the Vasgra Cohort

Erschienen in: European Journal of Nuclear Medicine and Molecular Imaging | Ausgabe 6/2019

Einloggen, um Zugang zu erhalten

Abstract

Background

To evaluate the diagnostic accuracy of positron emission tomography/computed tomography with 18F-fluorodeoxyglucose (PET/CT), contrast-enhanced CT (CE-CT), and a combined imaging approach (CE-PET/CT) in patients with suspected vascular graft infection (VGI).

Methods

PET/CT and CE-CT were performed prospectively in 23 patients with suspected VGI. Diagnostic accuracy for PET/CT was assessed by using previously suggested cut-off points for maximum standardized uptake values (SUVmax) measured in the vicinity of the graft. Using a new 4-point scale for visual grading, two readers independently assessed the diagnostic accuracy for CE-CT and combined CE-PET/CT. Microbiological culture, obtained after open biopsy or graft explantation, and clinical follow-up of the patients served as the standard of reference.

Results

Sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV), and accuracy of PET/CT for the diagnosis of VGI was 100%, 50%, 100%, 72.2%, and 78.3%, using the most favorable SUVmax cut-off ≥ 4.9. Respective values for CE-CT were 100%, 50%, 100%, 72.2%, and 78.3% for reader 1, and 92.3%, 80%, 88.9%, 85.7%, and 86.9% for reader 2; while respective values for combined CE-PET/CT were 100%, 70%, 100%, 81.3%, and 86.9% for reader 1, and 100%, 80%, 100%, 86.7%, and 91.3% for reader 2. Additionally, imaging provided a conclusive clinical diagnosis in patients without graft infection (i.e., other sites of infection): five of ten patients with CE-CT, six of ten patients with PET/CT, and seven of ten patients with combined CE-PET/CT.

Conclusion

The diagnostic accuracy of combined CE-PET/CT in patients with suspected VGI is very high. The combination of the high sensitivity of PET/CT in detecting metabolically active foci in infection, and the high specificity of CE-CT in detecting anatomic alterations, appears to be the reason why combined imaging outperforms stand-alone imaging in diagnosing VGI and may be supportive in future decision-making of difficult cases of suspected VGI.
Clinical Trials.gov Identifier: NCT01821664.
Literatur
1.
Zurück zum Zitat Hallett JW Jr, Marshall DM, Petterson TM, et al. Graft-related complications after abdominal aortic aneurysm repair: reassurance from a 36-year population-based experience. J Vasc Surg. 1997;25(2):277–84 discussion 285–286. Hallett JW Jr, Marshall DM, Petterson TM, et al. Graft-related complications after abdominal aortic aneurysm repair: reassurance from a 36-year population-based experience. J Vasc Surg. 1997;25(2):277–84 discussion 285–286.
2.
Zurück zum Zitat Wilson WR, Bower TC, Creager MA, et al. Vascular graft infections, mycotic aneurysms, and endovascular infections: a scientific statement from the American Heart Association. Circulation. 2016;134(20):e412–e60. Wilson WR, Bower TC, Creager MA, et al. Vascular graft infections, mycotic aneurysms, and endovascular infections: a scientific statement from the American Heart Association. Circulation. 2016;134(20):e412–e60.
3.
Zurück zum Zitat Hasse B, Husmann L, Zinkernagel A, Weber R, Lachat M, Mayer D. Vascular graft infections. Swiss Med Wkly. 2013;143:w13754.PubMed Hasse B, Husmann L, Zinkernagel A, Weber R, Lachat M, Mayer D. Vascular graft infections. Swiss Med Wkly. 2013;143:w13754.PubMed
4.
Zurück zum Zitat Keidar Z, Nitecki S. FDG-PET in prosthetic graft infections. Semin Nucl Med. 2013;43(5):396–402.CrossRefPubMed Keidar Z, Nitecki S. FDG-PET in prosthetic graft infections. Semin Nucl Med. 2013;43(5):396–402.CrossRefPubMed
5.
Zurück zum Zitat Lyons OT, Baguneid M, Barwick TD, et al. Diagnosis of aortic graft infection: a case definition by the Management of Aortic Graft Infection Collaboration (MAGIC). Eur J Vasc Endovasc Surg. 2016;52(6):758–63.CrossRefPubMed Lyons OT, Baguneid M, Barwick TD, et al. Diagnosis of aortic graft infection: a case definition by the Management of Aortic Graft Infection Collaboration (MAGIC). Eur J Vasc Endovasc Surg. 2016;52(6):758–63.CrossRefPubMed
6.
Zurück zum Zitat Fukuchi K, Ishida Y, Higashi M, et al. Detection of aortic graft infection by fluorodeoxyglucose positron emission tomography: comparison with computed tomographic findings. J Vasc Surg. 2005;42(5):919–25.CrossRefPubMed Fukuchi K, Ishida Y, Higashi M, et al. Detection of aortic graft infection by fluorodeoxyglucose positron emission tomography: comparison with computed tomographic findings. J Vasc Surg. 2005;42(5):919–25.CrossRefPubMed
7.
Zurück zum Zitat Keidar Z, Engel A, Hoffman A, Israel O, Nitecki S. Prosthetic vascular graft infection: the role of 18F-FDG PET/CT. J Nucl Med. 2007;48(8):1230–6.CrossRefPubMed Keidar Z, Engel A, Hoffman A, Israel O, Nitecki S. Prosthetic vascular graft infection: the role of 18F-FDG PET/CT. J Nucl Med. 2007;48(8):1230–6.CrossRefPubMed
8.
Zurück zum Zitat Spacek M, Belohlavek O, Votrubova J, Sebesta P, Stadler P. Diagnostics of "non-acute" vascular prosthesis infection using 18F-FDG PET/CT: our experience with 96 prostheses. Eur J Nucl Med Mol Imaging. 2009;36(5):850–8.CrossRefPubMed Spacek M, Belohlavek O, Votrubova J, Sebesta P, Stadler P. Diagnostics of "non-acute" vascular prosthesis infection using 18F-FDG PET/CT: our experience with 96 prostheses. Eur J Nucl Med Mol Imaging. 2009;36(5):850–8.CrossRefPubMed
9.
Zurück zum Zitat Bruggink JL, Glaudemans AW, Saleem BR, et al. Accuracy of FDG-PET-CT in the diagnostic work-up of vascular prosthetic graft infection. Eur J Vasc Endovasc Surg. 2010;40(3):348–54.CrossRefPubMed Bruggink JL, Glaudemans AW, Saleem BR, et al. Accuracy of FDG-PET-CT in the diagnostic work-up of vascular prosthetic graft infection. Eur J Vasc Endovasc Surg. 2010;40(3):348–54.CrossRefPubMed
10.
Zurück zum Zitat Sah BR, Husmann L, Mayer D, et al. Diagnostic performance of F-FDG-PET/CT in vascular graft infections. Eur J Vasc Endovasc Surg 2015;49(4):455–64. Sah BR, Husmann L, Mayer D, et al. Diagnostic performance of F-FDG-PET/CT in vascular graft infections. Eur J Vasc Endovasc Surg 2015;49(4):455–64.
11.
Zurück zum Zitat Tokuda Y, Oshima H, Araki Y, et al. Detection of thoracic aortic prosthetic graft infection with 18F-fluorodeoxyglucose positron emission tomography/computed tomography. Eur J Cardiothorac Surg. 2013;43(6):1183–7.CrossRefPubMed Tokuda Y, Oshima H, Araki Y, et al. Detection of thoracic aortic prosthetic graft infection with 18F-fluorodeoxyglucose positron emission tomography/computed tomography. Eur J Cardiothorac Surg. 2013;43(6):1183–7.CrossRefPubMed
12.
Zurück zum Zitat Stumpe KD, Dazzi H, Schaffner A, von Schulthess GK. Infection imaging using whole-body FDG-PET. Eur J Nucl Med. 2000;27(7):822–32.CrossRefPubMed Stumpe KD, Dazzi H, Schaffner A, von Schulthess GK. Infection imaging using whole-body FDG-PET. Eur J Nucl Med. 2000;27(7):822–32.CrossRefPubMed
13.
Zurück zum Zitat Low RN, Wall SD, Jeffrey RB Jr, Sollitto RA, Reilly LM, Tierney LM Jr. Aortoenteric fistula and perigraft infection: evaluation with CT. Radiology. 1990;175(1):157–62.CrossRefPubMed Low RN, Wall SD, Jeffrey RB Jr, Sollitto RA, Reilly LM, Tierney LM Jr. Aortoenteric fistula and perigraft infection: evaluation with CT. Radiology. 1990;175(1):157–62.CrossRefPubMed
14.
Zurück zum Zitat Bruggink JL, Slart RH, Pol JA, Reijnen MM, Zeebregts CJ. Current role of imaging in diagnosing aortic graft infections. Semin Vasc Surg. 2011;24(4):182–90.CrossRefPubMed Bruggink JL, Slart RH, Pol JA, Reijnen MM, Zeebregts CJ. Current role of imaging in diagnosing aortic graft infections. Semin Vasc Surg. 2011;24(4):182–90.CrossRefPubMed
15.
Zurück zum Zitat Keidar Z, Pirmisashvili N, Leiderman M, Nitecki S, Israel O. 18F-FDG uptake in noninfected prosthetic vascular grafts: incidence, patterns, and changes over time. J Nucl Med. 2014;55(3):392–5.CrossRefPubMed Keidar Z, Pirmisashvili N, Leiderman M, Nitecki S, Israel O. 18F-FDG uptake in noninfected prosthetic vascular grafts: incidence, patterns, and changes over time. J Nucl Med. 2014;55(3):392–5.CrossRefPubMed
16.
Zurück zum Zitat Husmann L, Hasse B. PET-CT in vascular graft infections. Zentralbl Chir. 2017;142(5):502–5.CrossRefPubMed Husmann L, Hasse B. PET-CT in vascular graft infections. Zentralbl Chir. 2017;142(5):502–5.CrossRefPubMed
17.
Zurück zum Zitat Pfannenberg AC, Aschoff P, Brechtel K, et al. Value of contrast-enhanced multiphase CT in combined PET/CT protocols for oncological imaging. Br J Radiol. 2007;80(954):437–45.CrossRefPubMed Pfannenberg AC, Aschoff P, Brechtel K, et al. Value of contrast-enhanced multiphase CT in combined PET/CT protocols for oncological imaging. Br J Radiol. 2007;80(954):437–45.CrossRefPubMed
18.
Zurück zum Zitat Saleem BR, Berger P, Vaartjes I, et al. Modest utility of quantitative measures in F-fluorodeoxyglucose positron emission tomography scanning for the diagnosis of aortic prosthetic graft infection. J Vasc Surg 2014;61(4):965–71.CrossRefPubMed Saleem BR, Berger P, Vaartjes I, et al. Modest utility of quantitative measures in F-fluorodeoxyglucose positron emission tomography scanning for the diagnosis of aortic prosthetic graft infection. J Vasc Surg 2014;61(4):965–71.CrossRefPubMed
19.
Zurück zum Zitat Cheson BD, Fisher RI, Barrington SF, et al. Recommendations for initial evaluation, staging, and response assessment of Hodgkin and non-Hodgkin lymphoma: the Lugano classification. J Clin Oncol. 2014;32(27):3059–68.CrossRefPubMedPubMedCentral Cheson BD, Fisher RI, Barrington SF, et al. Recommendations for initial evaluation, staging, and response assessment of Hodgkin and non-Hodgkin lymphoma: the Lugano classification. J Clin Oncol. 2014;32(27):3059–68.CrossRefPubMedPubMedCentral
20.
Zurück zum Zitat Pizzi MN, Roque A, Fernandez-Hidalgo N, et al. Improving the diagnosis of infective endocarditis in prosthetic valves and Intracardiac devices with 18F-Fluordeoxyglucose positron emission tomography/computed tomography angiography: initial results at an infective endocarditis referral center. Circulation. 2015;132(12):1113–26.CrossRefPubMed Pizzi MN, Roque A, Fernandez-Hidalgo N, et al. Improving the diagnosis of infective endocarditis in prosthetic valves and Intracardiac devices with 18F-Fluordeoxyglucose positron emission tomography/computed tomography angiography: initial results at an infective endocarditis referral center. Circulation. 2015;132(12):1113–26.CrossRefPubMed
21.
Zurück zum Zitat Kagna O, Kurash M, Ghanem-Zouabi N, Keidar Z, Israel O. Does antibiotic treatment affect the diagnostic accuracy of FDG PET/CT studies in patients with suspected infectious processes? J Nucl Med. 2017;58(11):1827–1830.CrossRefPubMed Kagna O, Kurash M, Ghanem-Zouabi N, Keidar Z, Israel O. Does antibiotic treatment affect the diagnostic accuracy of FDG PET/CT studies in patients with suspected infectious processes? J Nucl Med. 2017;58(11):1827–1830.CrossRefPubMed
Metadaten
Titel
Comparing diagnostic accuracy of 18F-FDG-PET/CT, contrast enhanced CT and combined imaging in patients with suspected vascular graft infections
verfasst von
Lars Husmann
Martin W. Huellner
Bruno Ledergerber
Alexia Anagnostopoulos
Paul Stolzmann
Bert-Ram Sah
Irene A. Burger
Zoran Rancic
Barbara Hasse
and the Vasgra Cohort
Publikationsdatum
13.11.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Nuclear Medicine and Molecular Imaging / Ausgabe 6/2019
Print ISSN: 1619-7070
Elektronische ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-018-4205-y

Weitere Artikel der Ausgabe 6/2019

European Journal of Nuclear Medicine and Molecular Imaging 6/2019 Zur Ausgabe