Abstract

This study was designed to investigate bone remodelling around the cup in cementless THA. Previous studies indicate an advantage of better sealing of the bone-prosthesis interface by HA/TCP coating of implants, inhibiting polyethylene-induced osteolysis. One hundred patients gave informed consent to participate in a controlled randomized study between porous coated Trilogy versus Trilogy Calcicoat (HA/TCP coated). The cup was inserted in press-fit fixation. The femoral component was a cementless porous coated titanium alloy stem (Bi-Metric), with a modular 28-mm CrCo head. The Harris Hip Score (HHS) and bone mineral density (BMD) determined by DEXA scanning were used to study the effect. Measurements revealed no difference between the two groups after 3 years either in the clinical outcome or in terms of periprosthetic bone density. Patients with a body mass index above normal regained more bone mineral than patients with normal weight. This finding supports the assumption that load is beneficial to bone remodelling.
Literatur
1.
Zurück zum Zitat Aldinger PR, Sabo D, Pritsch M, Thomsen M, Mau H, Ewerbeck V, Breusch SJ (2003) Pattern of periprosthetic bone remodeling around stable uncemented tapered hip stems: a prospective 84-month follow-up study and a median 156-month cross-sectional study with DXA. Calcif Tissue Int 73:115–121PubMedCrossRef Aldinger PR, Sabo D, Pritsch M, Thomsen M, Mau H, Ewerbeck V, Breusch SJ (2003) Pattern of periprosthetic bone remodeling around stable uncemented tapered hip stems: a prospective 84-month follow-up study and a median 156-month cross-sectional study with DXA. Calcif Tissue Int 73:115–121PubMedCrossRef
2.
Zurück zum Zitat Bauer TW, Stulberg BN, Ming J, Geesink RG (1993) Uncemented acetabular components. Histologic analysis of retrieved hydroxyapatite-coated and porous implants. J Arthroplasty 8:167–177PubMed Bauer TW, Stulberg BN, Ming J, Geesink RG (1993) Uncemented acetabular components. Histologic analysis of retrieved hydroxyapatite-coated and porous implants. J Arthroplasty 8:167–177PubMed
3.
Zurück zum Zitat Boden H, Adolphson P (2004) No adverse effects of early weight bearing after uncemented total hip arthroplasty: a randomized study of 20 patients. Acta Orthop Scand 75:21–29PubMed Boden H, Adolphson P (2004) No adverse effects of early weight bearing after uncemented total hip arthroplasty: a randomized study of 20 patients. Acta Orthop Scand 75:21–29PubMed
4.
Zurück zum Zitat Engh CA Jr, Sychterz C, Engh C Sr (1999) Factors affecting femoral bone remodeling after cementless total hip arthroplasty. J Arthroplasty 14:637–644PubMedCrossRef Engh CA Jr, Sychterz C, Engh C Sr (1999) Factors affecting femoral bone remodeling after cementless total hip arthroplasty. J Arthroplasty 14:637–644PubMedCrossRef
5.
Zurück zum Zitat Gehrchen PM (1999) Quantitative measurements of adaptive bone remodeling in the proximal femur following uncemented total hip arthroplasty using dual energy X-ray absorptiometry. Ph.D.-thesis. Danish National Hospital, University of Copenhagen Gehrchen PM (1999) Quantitative measurements of adaptive bone remodeling in the proximal femur following uncemented total hip arthroplasty using dual energy X-ray absorptiometry. Ph.D.-thesis. Danish National Hospital, University of Copenhagen
6.
Zurück zum Zitat Havelin LI, Engesaeter LB, Espehaug B, Furnes O, Lie SA, Vollset SE (2000) The Norwegian arthroplasty register: 11 years and 73,000 arthroplasties. Acta Orthop Scand 71:337–353PubMedCrossRef Havelin LI, Engesaeter LB, Espehaug B, Furnes O, Lie SA, Vollset SE (2000) The Norwegian arthroplasty register: 11 years and 73,000 arthroplasties. Acta Orthop Scand 71:337–353PubMedCrossRef
7.
Zurück zum Zitat Ibrahim T, Hobson S, Beiri A, Esler CN (2005) No influence of body mass index on early outcome following total hip arthroplasty. Int Orthop 29:359–361PubMedCrossRef Ibrahim T, Hobson S, Beiri A, Esler CN (2005) No influence of body mass index on early outcome following total hip arthroplasty. Int Orthop 29:359–361PubMedCrossRef
8.
Zurück zum Zitat Karrholm J, Malchau H, Snorrason F, Herberts P (1994) Micromotion of femoral stems in total hip arthroplasty. A randomized study of cemented, hydroxyapatite-coated, and porous-coated stems with roentgen stereophotogrammetric analysis. J Bone Joint Surg Am 76:1692–1705PubMed Karrholm J, Malchau H, Snorrason F, Herberts P (1994) Micromotion of femoral stems in total hip arthroplasty. A randomized study of cemented, hydroxyapatite-coated, and porous-coated stems with roentgen stereophotogrammetric analysis. J Bone Joint Surg Am 76:1692–1705PubMed
9.
Zurück zum Zitat Laursen MB, Nielsen PT, Soballe K (2006) Detection of bony defects around cementless acetabular components in total hip arthroplasty. A DEXA study on ten human cadavers. Acta Orthop Scand 77(2):209–217 Laursen MB, Nielsen PT, Soballe K (2006) Detection of bony defects around cementless acetabular components in total hip arthroplasty. A DEXA study on ten human cadavers. Acta Orthop Scand 77(2):209–217
10.
Zurück zum Zitat Laursen MB, Nielsen PT, Soballe K (2005) DXA scanning of acetabulum in patients with cementless total hip arthroplasty. J Clin Densitom 8:476–483PubMedCrossRef Laursen MB, Nielsen PT, Soballe K (2005) DXA scanning of acetabulum in patients with cementless total hip arthroplasty. J Clin Densitom 8:476–483PubMedCrossRef
11.
Zurück zum Zitat Levenston ME, Beaupre GS, Schurman DJ, Carter DR (1993) Computer simulations of stress-related bone remodeling around noncemented acetabular components. J Arthroplasty 8:595–605PubMedCrossRef Levenston ME, Beaupre GS, Schurman DJ, Carter DR (1993) Computer simulations of stress-related bone remodeling around noncemented acetabular components. J Arthroplasty 8:595–605PubMedCrossRef
12.
Zurück zum Zitat Rahbek O, Kold S, Zippor B, Overgaard S, Soballe K (2005) Particle migration and gap healing around trabecular metal implants. Int Orthop 29:368–374PubMedCrossRef Rahbek O, Kold S, Zippor B, Overgaard S, Soballe K (2005) Particle migration and gap healing around trabecular metal implants. Int Orthop 29:368–374PubMedCrossRef
13.
Zurück zum Zitat Rohrl SM, Nivbrant B, Strom H, Nilsson KG (2004) Effect of augmented cup fixation on stability, wear, and osteolysis: a 5-year follow-up of total hip arthroplasty with RSA. J Arthroplasty 19:962–971PubMed Rohrl SM, Nivbrant B, Strom H, Nilsson KG (2004) Effect of augmented cup fixation on stability, wear, and osteolysis: a 5-year follow-up of total hip arthroplasty with RSA. J Arthroplasty 19:962–971PubMed
14.
Zurück zum Zitat Sabo D, Reiter A, Simank HG, Thomsen M, Lukoschek M, Ewerbeck V (1998) Periprosthetic mineralization around cementless total hip endoprosthesis: longitudinal study and cross-sectional study on titanium threaded acetabular cup and cementless Spotorno stem with DEXA. Calcif Tissue Int 62:177–182PubMedCrossRef Sabo D, Reiter A, Simank HG, Thomsen M, Lukoschek M, Ewerbeck V (1998) Periprosthetic mineralization around cementless total hip endoprosthesis: longitudinal study and cross-sectional study on titanium threaded acetabular cup and cementless Spotorno stem with DEXA. Calcif Tissue Int 62:177–182PubMedCrossRef
15.
Zurück zum Zitat Schmalzried TP, Wessinger SJ, Hill GE, Harris WH (1994) The Harris-Galante porous acetabular component press-fit without screw fixation. Five-year radiographic analysis of primary cases. J Arthroplasty 9:235–242PubMedCrossRef Schmalzried TP, Wessinger SJ, Hill GE, Harris WH (1994) The Harris-Galante porous acetabular component press-fit without screw fixation. Five-year radiographic analysis of primary cases. J Arthroplasty 9:235–242PubMedCrossRef
16.
Zurück zum Zitat Soballe K, Hansen ES, Brockstedt RH, Pedersen CM, Bunger C (1990) Hydroxyapatite coating enhances fixation of porous coated implants. A comparison in dogs between press fit and noninterference fit. Acta Orthop Scand 61:299–306PubMedCrossRef Soballe K, Hansen ES, Brockstedt RH, Pedersen CM, Bunger C (1990) Hydroxyapatite coating enhances fixation of porous coated implants. A comparison in dogs between press fit and noninterference fit. Acta Orthop Scand 61:299–306PubMedCrossRef
17.
Zurück zum Zitat Soballe K, Toksvig-Larsen S, Gelineck J, Fruensgaard S, Hansen ES, Ryd L, Lucht U, Bunger C (1993) Migration of hydroxyapatite coated femoral prostheses. A Roentgen Stereophotogrammetric study. J Bone Joint Surg Br 75:681–687PubMed Soballe K, Toksvig-Larsen S, Gelineck J, Fruensgaard S, Hansen ES, Ryd L, Lucht U, Bunger C (1993) Migration of hydroxyapatite coated femoral prostheses. A Roentgen Stereophotogrammetric study. J Bone Joint Surg Br 75:681–687PubMed
18.
Zurück zum Zitat Thanner J, Karrholm J, Herberts P, Malchau H (1999) Porous cups with and without hydroxylapatite-tricalcium phosphate coating: 23 matched pairs evaluated with radiostereometry. J Arthroplasty 14:266–271PubMedCrossRef Thanner J, Karrholm J, Herberts P, Malchau H (1999) Porous cups with and without hydroxylapatite-tricalcium phosphate coating: 23 matched pairs evaluated with radiostereometry. J Arthroplasty 14:266–271PubMedCrossRef
19.
Zurück zum Zitat Thanner J, Karrholm J, Herberts P, Malchau H (2000) Hydroxyapatite and tricalcium phosphate-coated cups with and without screw fixation: a randomized study of 64 hips. J Arthroplasty 15:405–412PubMedCrossRef Thanner J, Karrholm J, Herberts P, Malchau H (2000) Hydroxyapatite and tricalcium phosphate-coated cups with and without screw fixation: a randomized study of 64 hips. J Arthroplasty 15:405–412PubMedCrossRef
20.
Zurück zum Zitat Wilkinson JM, Hamer AJ, Rogers A, Stockley I, Eastell R (2003) Bone mineral density and biochemical markers of bone turnover in aseptic loosening after total hip arthroplasty. J. Orthop Res. 21:691–696PubMedCrossRef Wilkinson JM, Hamer AJ, Rogers A, Stockley I, Eastell R (2003) Bone mineral density and biochemical markers of bone turnover in aseptic loosening after total hip arthroplasty. J. Orthop Res. 21:691–696PubMedCrossRef
21.
Zurück zum Zitat Wilkinson JM, Peel NF, Elson RA, Stockley I, Eastell R (2001) Measuring bone mineral density of the pelvis and proximal femur after total hip arthroplasty. J Bone Joint Surg Br 83:283–288PubMedCrossRef Wilkinson JM, Peel NF, Elson RA, Stockley I, Eastell R (2001) Measuring bone mineral density of the pelvis and proximal femur after total hip arthroplasty. J Bone Joint Surg Br 83:283–288PubMedCrossRef
22.
Zurück zum Zitat Wright JM, Pellicci PM, Salvati EA, Ghelman B, Roberts MM, Koh JL (2001) Bone density adjacent to press-fit acetabular components. A prospective analysis with quantitative computed tomography. J Bone Joint Surg Am 83-A:529–536PubMed Wright JM, Pellicci PM, Salvati EA, Ghelman B, Roberts MM, Koh JL (2001) Bone density adjacent to press-fit acetabular components. A prospective analysis with quantitative computed tomography. J Bone Joint Surg Am 83-A:529–536PubMed
Metadaten
Titel
Bone remodelling around HA-coated acetabular cups
A DEXA study with a 3-year follow-up in a randomised trial
verfasst von
M. B. Laursen
P. T. Nielsen
K. Søballe
Publikationsdatum
01.04.2007
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 2/2007
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-006-0148-1

Weitere Artikel der Ausgabe 2/2007

International Orthopaedics 2/2007 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.