The EOS™ imaging system and its uses in daily orthopaedic practice

verfasst von: Tamás Illés, Szabolcs Somoskeöy

Erschienen in: International Orthopaedics | Ausgabe 7/2012

Einloggen, um Zugang zu erhalten

Abstract

Background

The EOS™ X-ray machine, based on a Nobel prize-winning invention in physics in the field of particle detection, is capable of a simultaneous capture of biplanar X-ray images by slot scanning of the whole body in an upright, physiological load-bearing position, using ultra-low radiation doses. The simultaneous capture of spatially calibrated anterioposterior and lateral images provides a three-dimensional (3D) surface reconstruction of the skeletal system using a special software. Parts of the skeletal system in X-ray images and 3D-reconstructed models appear in true 1:1 scale for size and volume, thus spinal and vertebral parameters, lower limb axis lengths and angles, as well as any relevant clinical parameters in orthopaedic practice can be very precisely measured and calculated. Visualisation of 3D reconstructed models in various views by sterEOS 3D software enables presentation of top view images to help analyse rotational conditions of lower limbs, joints and spine deformities in the horizontal plane, providing revolutionary novel possibilities in orthopaedic surgery, especially in spine surgery.

Approach and conclusions

Our department has been extensively using the very first commercially available EOS™ imaging system worldwide for routine orthopaedic diagnostics since June 2007. During this period of about 4.5 years, more than 5,700 standard examinations have been carried out, about a third of them in spine deformity cases and the rest in lower limb orthopaedic cases. In this mini-review, general principles and uses of this groundbreaking integrated orthopaedic solution is reviewed with a few highlighted examples from our own clinical practice.
Literatur
2.
Zurück zum Zitat Charpak G (1981) La détection des particules. Recherche 128:1384–1396 Charpak G (1981) La détection des particules. Recherche 128:1384–1396
3.
Zurück zum Zitat Charpak G (1993) Electronic imaging of ionizing radiation with limited avalanches in gases. Rev Mod Phys 6:591–598CrossRef Charpak G (1993) Electronic imaging of ionizing radiation with limited avalanches in gases. Rev Mod Phys 6:591–598CrossRef
4.
Zurück zum Zitat Després P, Beaudoin G, Gravel P et al (2005) Evaluation of a full-scale gas microstrip detector for low-dose X-ray imaging. Nucl Instr Meth Phys Res A 536:52–60CrossRef Després P, Beaudoin G, Gravel P et al (2005) Evaluation of a full-scale gas microstrip detector for low-dose X-ray imaging. Nucl Instr Meth Phys Res A 536:52–60CrossRef
5.
Zurück zum Zitat Dubousset J, Charpak G, Dorion I et al (2005) Le system EOS nouvelle imagerie osteo-articulaire basse dose en position debout. E-mémoire de l’Académie National de Chirugie 4:22–27 Dubousset J, Charpak G, Dorion I et al (2005) Le system EOS nouvelle imagerie osteo-articulaire basse dose en position debout. E-mémoire de l’Académie National de Chirugie 4:22–27
6.
Zurück zum Zitat Dubousset J, Charpak G, Dorion I et al (2005) A new 2D and 3D imaging approach to musculoskeletal physiology and pathology with low-dose radiation and the standing position: the EOS system. Bull Acad Natl Med 189:287–297PubMed Dubousset J, Charpak G, Dorion I et al (2005) A new 2D and 3D imaging approach to musculoskeletal physiology and pathology with low-dose radiation and the standing position: the EOS system. Bull Acad Natl Med 189:287–297PubMed
7.
Zurück zum Zitat Le Bras A, Laporte S, Mitton D et al (2002) 3D detailed reconstruction of vertebrae with low dose digital stereoradiography. Stud Health Technol Inform 91:286–290PubMed Le Bras A, Laporte S, Mitton D et al (2002) 3D detailed reconstruction of vertebrae with low dose digital stereoradiography. Stud Health Technol Inform 91:286–290PubMed
8.
Zurück zum Zitat Le Bras A, Laporte S, Mitton D et al (2003) A biplanar reconstruction method based on 2D and 3D contours: application to the distal femur. Comput Methods Biomech Biomed Engin 6:1–6CrossRef Le Bras A, Laporte S, Mitton D et al (2003) A biplanar reconstruction method based on 2D and 3D contours: application to the distal femur. Comput Methods Biomech Biomed Engin 6:1–6CrossRef
9.
Zurück zum Zitat Mitton D, Landry C, Véron S et al (2000) A 3D reconstruction method from biplanar radiography using non-stereocorresponding points and elastic deformable meshes. Med Biol Eng Comput 38:133–139PubMedCrossRef Mitton D, Landry C, Véron S et al (2000) A 3D reconstruction method from biplanar radiography using non-stereocorresponding points and elastic deformable meshes. Med Biol Eng Comput 38:133–139PubMedCrossRef
10.
Zurück zum Zitat Mitulescu A, Semaan I, De Guise JA et al (2001) Validation of the non-stereo corresponding points stereoradiographic 3D reconstruction technique. Med Biol Eng Comput 39:152–158PubMedCrossRef Mitulescu A, Semaan I, De Guise JA et al (2001) Validation of the non-stereo corresponding points stereoradiographic 3D reconstruction technique. Med Biol Eng Comput 39:152–158PubMedCrossRef
11.
Zurück zum Zitat Kalifa G, Charpak G, Maccia C et al (1998) Evaluation of a new low-dose digital x-ray device: first dosimetric and clinical result in children. Pediatr Radiol 28:557–561PubMedCrossRef Kalifa G, Charpak G, Maccia C et al (1998) Evaluation of a new low-dose digital x-ray device: first dosimetric and clinical result in children. Pediatr Radiol 28:557–561PubMedCrossRef
12.
Zurück zum Zitat Than P, Szuper K, Somoskeöy S et al (2011) Geometrical values of the normal and arthritic hip and knee detected with the EOS imaging system. Int Orthop (SICOT). doi:10.1007/s00264-011-1403-7 Than P, Szuper K, Somoskeöy S et al (2011) Geometrical values of the normal and arthritic hip and knee detected with the EOS imaging system. Int Orthop (SICOT). doi:10.​1007/​s00264-011-1403-7
Metadaten
Titel
The EOS™ imaging system and its uses in daily orthopaedic practice
verfasst von
Tamás Illés
Szabolcs Somoskeöy
Publikationsdatum
01.07.2012
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 7/2012
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-012-1512-y

Weitere Artikel der Ausgabe 7/2012

International Orthopaedics 7/2012 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.