Skip to main content
Erschienen in: International Orthopaedics 9/2012

01.09.2012 | Original Paper

Long-term follow-up and metal ion trend of patients with metal-on-metal total hip arthroplasty

verfasst von: Mitchell Bernstein, Nicholas M. Desy, Alain Petit, David J. Zukor, Olga L. Huk, John Antoniou

Erschienen in: International Orthopaedics | Ausgabe 9/2012

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Long-term studies are required to support the use of metal-on-metal (MoM) bearings in total hip arthroplasty (THA) given the concern about systemic metal ion release and reports of adverse local soft tissue reactions. The purpose of this study was to report the seven to 13-year clinical, radiographic, and metal ion results in patients following MoM THA.

Methods

We studied 163 prostheses after second-generation MoM THA between July 1997 and November 2003. Cobalt and chromium metal ions were collected using whole and analysed by inductively-coupled plasma-mass spectrometry.

Results

The mean follow-up was 8.87 years (range, 7–13 years). Four hips (2.5 %) were revised. The Kaplan-Meier survivorship was 91.3 % for revision for all causes, and 97.5 % when excluding the hips revised for a manufacturer’s defect. Median whole blood cobalt levels peaked at a value of 2.87 μg/L at four years (p < 0.0001 vs. pre-operative) and subsequently decreased to 2.0 μg/L after nine years (p = 0.002 vs. four years). Median chromium levels maximally increased up to 0.75 μg/L after five years (p < 0.0001 vs. pre-operative) and tended to decrease thereafter to values of 0.56 μg/L after seven years.

Conclusions

This seven to 13-year follow-up study indicates that the clinical and radiological results following MoM THA are satisfactory with low revision rates. Cobalt and chromium ion levels peaked at four and five years, respectively, and gradually decreased thereafter.
Literatur
1.
Zurück zum Zitat Chan FW, Bobyn JD, Medley JB, Krygier JJ, Tanzer M (1999) The Otto Aufranc Award. Wear and lubrication of metal-on-metal hip implants. Clin Orthop Relat Res 369:10–24PubMedCrossRef Chan FW, Bobyn JD, Medley JB, Krygier JJ, Tanzer M (1999) The Otto Aufranc Award. Wear and lubrication of metal-on-metal hip implants. Clin Orthop Relat Res 369:10–24PubMedCrossRef
2.
Zurück zum Zitat Girard J, Bocquet D, Autissier G, Fouilleron N, Fron D, Migaud H (2010) Metal-on-metal hip arthroplasty in patients thirty years of age or younger. J Bone Joint Surg Am 92(14):2419–2426PubMedCrossRef Girard J, Bocquet D, Autissier G, Fouilleron N, Fron D, Migaud H (2010) Metal-on-metal hip arthroplasty in patients thirty years of age or younger. J Bone Joint Surg Am 92(14):2419–2426PubMedCrossRef
3.
Zurück zum Zitat Chan FW, Bobyn JD, Medley JB, Krygier JJ, Yue S, Tanzer M (1996) Engineering issues and wear performance of metal on metal hip implants. Clin Orthop Relat Res 333:96–107PubMedCrossRef Chan FW, Bobyn JD, Medley JB, Krygier JJ, Yue S, Tanzer M (1996) Engineering issues and wear performance of metal on metal hip implants. Clin Orthop Relat Res 333:96–107PubMedCrossRef
4.
Zurück zum Zitat Prosser GH, Yates PJ, Wood DJ, Graves SE, de Steiger RN, Miller LN (2010) Outcome of primary resurfacing hip replacement: evaluation of risk factors for early revision. Acta Orthop 81(1):66–71PubMedCrossRef Prosser GH, Yates PJ, Wood DJ, Graves SE, de Steiger RN, Miller LN (2010) Outcome of primary resurfacing hip replacement: evaluation of risk factors for early revision. Acta Orthop 81(1):66–71PubMedCrossRef
5.
Zurück zum Zitat Jacobs JJ, Skipor AK, Patterson LM, Hallab NJ, Paprosky WG, Black J, Galante JO (1998) Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study. J Bone Joint Surg Am 80(10):1447–1458PubMed Jacobs JJ, Skipor AK, Patterson LM, Hallab NJ, Paprosky WG, Black J, Galante JO (1998) Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study. J Bone Joint Surg Am 80(10):1447–1458PubMed
6.
Zurück zum Zitat Antoniou J, Zukor DJ, Mwale F, Minarik W, Petit A, Huk OL (2008) Metal ion levels in the blood of patients after hip resurfacing: a comparison between twenty-eight and thirty-six-millimeter-head metal-on-metal prostheses. J Bone Joint Surg Am 90(Suppl 3):142–148PubMedCrossRef Antoniou J, Zukor DJ, Mwale F, Minarik W, Petit A, Huk OL (2008) Metal ion levels in the blood of patients after hip resurfacing: a comparison between twenty-eight and thirty-six-millimeter-head metal-on-metal prostheses. J Bone Joint Surg Am 90(Suppl 3):142–148PubMedCrossRef
7.
Zurück zum Zitat Vendittoli PA, Amzica T, Roy AG, Lusignan D, Girard J, Lavigne M (2011) Metal ion release with large-diameter metal-on-metal hip arthroplasty. J Arthroplasty 26(2):282–288PubMedCrossRef Vendittoli PA, Amzica T, Roy AG, Lusignan D, Girard J, Lavigne M (2011) Metal ion release with large-diameter metal-on-metal hip arthroplasty. J Arthroplasty 26(2):282–288PubMedCrossRef
8.
Zurück zum Zitat Walter LR, Marel E, Harbury R, Wearne J (2008) Distribution of chromium and cobalt ions in various blood fractions after resurfacing hip arthroplasty. J Arthroplasty 23(6):814–821PubMedCrossRef Walter LR, Marel E, Harbury R, Wearne J (2008) Distribution of chromium and cobalt ions in various blood fractions after resurfacing hip arthroplasty. J Arthroplasty 23(6):814–821PubMedCrossRef
9.
Zurück zum Zitat MacDonald SJ, Brodner W, Jacobs JJ (2004) A consensus paper on metal ions in metal-on-metal hip arthroplasties. J Arthroplasty 19(8 Suppl 3):12–16PubMedCrossRef MacDonald SJ, Brodner W, Jacobs JJ (2004) A consensus paper on metal ions in metal-on-metal hip arthroplasties. J Arthroplasty 19(8 Suppl 3):12–16PubMedCrossRef
10.
Zurück zum Zitat Davies AP, Sood A, Lewis AC, Newson R, Learmonth ID, Case CP (2005) Metal-specific differences in levels of DNA damage caused by synovial fluid recovered at revision arthroplasty. J Bone Joint Surg Br 87(10):1439–1444PubMedCrossRef Davies AP, Sood A, Lewis AC, Newson R, Learmonth ID, Case CP (2005) Metal-specific differences in levels of DNA damage caused by synovial fluid recovered at revision arthroplasty. J Bone Joint Surg Br 87(10):1439–1444PubMedCrossRef
11.
Zurück zum Zitat Huk OL, Catelas I, Mwale F, Antoniou J, Zukor DJ, Petit A (2004) Induction of apoptosis and necrosis by metal ions in vitro. J Arthroplasty 19(8 Suppl 3):84–87PubMedCrossRef Huk OL, Catelas I, Mwale F, Antoniou J, Zukor DJ, Petit A (2004) Induction of apoptosis and necrosis by metal ions in vitro. J Arthroplasty 19(8 Suppl 3):84–87PubMedCrossRef
12.
Zurück zum Zitat Eswaramoorthy V, Moonot P, Kalairajah Y, Biant LC, Field RE (2008) The Metasul metal-on-metal articulation in primary total hip replacement: clinical and radiological results at ten years. J Bone Joint Surg Br 90(10):1278–1283PubMedCrossRef Eswaramoorthy V, Moonot P, Kalairajah Y, Biant LC, Field RE (2008) The Metasul metal-on-metal articulation in primary total hip replacement: clinical and radiological results at ten years. J Bone Joint Surg Br 90(10):1278–1283PubMedCrossRef
13.
Zurück zum Zitat Grubl A, Marker M, Brodner W, Giurea A, Heinze G, Meisinger V, Zehetgruber H, Kotz R (2007) Long-term follow-up of metal-on-metal total hip replacement. J Orthop Res 25(7):841–848PubMedCrossRef Grubl A, Marker M, Brodner W, Giurea A, Heinze G, Meisinger V, Zehetgruber H, Kotz R (2007) Long-term follow-up of metal-on-metal total hip replacement. J Orthop Res 25(7):841–848PubMedCrossRef
14.
Zurück zum Zitat Maezawa K, Nozawa M, Yuasa T, Aritomi K, Matsuda K, Shitoto K (2010) Seven years of chronological changes of serum chromium levels after Metasul metal-on-metal total hip arthroplasty. J Arthroplasty 25(8):1196–1200PubMedCrossRef Maezawa K, Nozawa M, Yuasa T, Aritomi K, Matsuda K, Shitoto K (2010) Seven years of chronological changes of serum chromium levels after Metasul metal-on-metal total hip arthroplasty. J Arthroplasty 25(8):1196–1200PubMedCrossRef
15.
Zurück zum Zitat Neumann DR, Thaler C, Hitzl W, Huber M, Hofstädter T, Dorn U (2010) Long-term results of a contemporary metal-on-metal total hip arthroplasty: a 10-year follow-up study. J Arthroplasty 25(5):700–708PubMedCrossRef Neumann DR, Thaler C, Hitzl W, Huber M, Hofstädter T, Dorn U (2010) Long-term results of a contemporary metal-on-metal total hip arthroplasty: a 10-year follow-up study. J Arthroplasty 25(5):700–708PubMedCrossRef
16.
Zurück zum Zitat Saito S, Ishii T, Mori S, Hosaka K, Ootaki M, Tokuhashi Y (2010) Long-term results of metasul metal-on-metal total hip arthroplasty. Orthopedics 33(8):548 Saito S, Ishii T, Mori S, Hosaka K, Ootaki M, Tokuhashi Y (2010) Long-term results of metasul metal-on-metal total hip arthroplasty. Orthopedics 33(8):548
17.
Zurück zum Zitat Dastane M, Wan Z, Deshmane P, Long WT, Dorr LD (2011) Primary hip arthroplasty with 28-mm Metasul articulation. J Arthroplasty 26(4):662–664PubMedCrossRef Dastane M, Wan Z, Deshmane P, Long WT, Dorr LD (2011) Primary hip arthroplasty with 28-mm Metasul articulation. J Arthroplasty 26(4):662–664PubMedCrossRef
18.
Zurück zum Zitat Milosev I, Trebse R, Kovac S, Cör A, Pisot V (2006) Survivorship and retrieval analysis of Sikomet metal-on-metal total hip replacements at a mean of seven years. J Bone Joint Surg Am 88(6):1173–1182PubMedCrossRef Milosev I, Trebse R, Kovac S, Cör A, Pisot V (2006) Survivorship and retrieval analysis of Sikomet metal-on-metal total hip replacements at a mean of seven years. J Bone Joint Surg Am 88(6):1173–1182PubMedCrossRef
19.
Zurück zum Zitat Randelli F, Banci L, D’Anna A, Visentin O, Randelli G (2012) Cementless Metasul metal-on-metal total hip arthroplasties at 13 years. J Arthroplasty 27(2):186–192PubMedCrossRef Randelli F, Banci L, D’Anna A, Visentin O, Randelli G (2012) Cementless Metasul metal-on-metal total hip arthroplasties at 13 years. J Arthroplasty 27(2):186–192PubMedCrossRef
20.
Zurück zum Zitat Blumenfeld TJ, Bargar WL (2006) Early aseptic loosening of a modern acetabular component secondary to a change in manufacturing. J Arthroplasty 21(5):689–695PubMedCrossRef Blumenfeld TJ, Bargar WL (2006) Early aseptic loosening of a modern acetabular component secondary to a change in manufacturing. J Arthroplasty 21(5):689–695PubMedCrossRef
21.
Zurück zum Zitat Krismer M, Bauer R, Tschupik J, Mayrhofer P (1995) EBRA: a method to measure migration of acetabular components. J Biomech 28(10):1225–1236PubMedCrossRef Krismer M, Bauer R, Tschupik J, Mayrhofer P (1995) EBRA: a method to measure migration of acetabular components. J Biomech 28(10):1225–1236PubMedCrossRef
22.
Zurück zum Zitat Case CP, Ellis L, Turner JC, Fairman B (2001) Development of a routine method for the determination of trace metals in whole blood by magnetic sector inductively coupled plasma mass spectrometry with particular relevance to patients with total hip and knee arthroplasty. Clin Chem 47(2):275–280PubMed Case CP, Ellis L, Turner JC, Fairman B (2001) Development of a routine method for the determination of trace metals in whole blood by magnetic sector inductively coupled plasma mass spectrometry with particular relevance to patients with total hip and knee arthroplasty. Clin Chem 47(2):275–280PubMed
23.
Zurück zum Zitat Brodner W, Grubl A, Jankovsky R, Meisinger V, Lehr S, Gottsauner-Wolf F (2004) Cup inclination and serum concentration of cobalt and chromium after metal-on-metal total hip arthroplasty. J Arthroplasty 19(8 Suppl 3):66–70PubMedCrossRef Brodner W, Grubl A, Jankovsky R, Meisinger V, Lehr S, Gottsauner-Wolf F (2004) Cup inclination and serum concentration of cobalt and chromium after metal-on-metal total hip arthroplasty. J Arthroplasty 19(8 Suppl 3):66–70PubMedCrossRef
24.
Zurück zum Zitat De Haan R, Pattyn C, Gill HS, Murray DW, Campbell PA, De Smet K (2008) Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. J Bone Joint Surg Br 90(10):1291–1297PubMedCrossRef De Haan R, Pattyn C, Gill HS, Murray DW, Campbell PA, De Smet K (2008) Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. J Bone Joint Surg Br 90(10):1291–1297PubMedCrossRef
25.
Zurück zum Zitat Hart AJ, Hester T, Sinclair K, Powell JJ, Goodship AE, Pele L, Fersht NL, Skinner J (2006) The association between metal ions from hip resurfacing and reduced T-cell counts. J Bone Joint Surg Br 88(4):449–454PubMedCrossRef Hart AJ, Hester T, Sinclair K, Powell JJ, Goodship AE, Pele L, Fersht NL, Skinner J (2006) The association between metal ions from hip resurfacing and reduced T-cell counts. J Bone Joint Surg Br 88(4):449–454PubMedCrossRef
26.
Zurück zum Zitat Hart AJ, Skinner JA, Winship P, Faria N, Kulinskaya E, Webster D, Muirhead-Allwood S, Aldam CH, Anwar H, Powell JJ (2009) Circulating levels of cobalt and chromium from metal-on-metal hip replacement are associated with CD8+ T-cell lymphopenia. J Bone Joint Surg Br 91(6):835–842PubMedCrossRef Hart AJ, Skinner JA, Winship P, Faria N, Kulinskaya E, Webster D, Muirhead-Allwood S, Aldam CH, Anwar H, Powell JJ (2009) Circulating levels of cobalt and chromium from metal-on-metal hip replacement are associated with CD8+ T-cell lymphopenia. J Bone Joint Surg Br 91(6):835–842PubMedCrossRef
27.
Zurück zum Zitat Kwon YM, Thomas P, Summer B, Pandit H, Taylor A, Beard D, Murray DW, Gill HS (2010) Lymphocyte proliferation responses in patients with pseudotumors following metal-on-metal hip resurfacing arthroplasty. J Orthop Res 28(4):444–450PubMed Kwon YM, Thomas P, Summer B, Pandit H, Taylor A, Beard D, Murray DW, Gill HS (2010) Lymphocyte proliferation responses in patients with pseudotumors following metal-on-metal hip resurfacing arthroplasty. J Orthop Res 28(4):444–450PubMed
28.
Zurück zum Zitat Willert HG, Buchhorn GH, Fayyazi A, Flury R, Windler M, Köster G, Lohmann CH (2005) Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am 87(1):28–36PubMedCrossRef Willert HG, Buchhorn GH, Fayyazi A, Flury R, Windler M, Köster G, Lohmann CH (2005) Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am 87(1):28–36PubMedCrossRef
29.
Zurück zum Zitat Williams S, Leslie I, Isaac G, Jin Z, Ingham E, Fisher J (2008) Tribology and wear of metal-on-metal hip prostheses: influence of cup angle and head position. J Bone Joint Surg Am 90(Suppl 3):111–117PubMedCrossRef Williams S, Leslie I, Isaac G, Jin Z, Ingham E, Fisher J (2008) Tribology and wear of metal-on-metal hip prostheses: influence of cup angle and head position. J Bone Joint Surg Am 90(Suppl 3):111–117PubMedCrossRef
30.
Zurück zum Zitat Daniel J, Ziaee H, Pynsent PB, McMinn DJ (2007) The validity of serum levels as a surrogate measure of systemic exposure to metal ions in hip replacement. J Bone Joint Surg Br 89(6):736–741PubMedCrossRef Daniel J, Ziaee H, Pynsent PB, McMinn DJ (2007) The validity of serum levels as a surrogate measure of systemic exposure to metal ions in hip replacement. J Bone Joint Surg Br 89(6):736–741PubMedCrossRef
31.
Zurück zum Zitat Hur CI, Yoon TR, Cho SG, Song EK, Seon JK (2008) Serum ion level after metal-on-metal THA in patients with renal failure. Clin Orthop Relat Res 466(3):696–699PubMedCrossRef Hur CI, Yoon TR, Cho SG, Song EK, Seon JK (2008) Serum ion level after metal-on-metal THA in patients with renal failure. Clin Orthop Relat Res 466(3):696–699PubMedCrossRef
Metadaten
Titel
Long-term follow-up and metal ion trend of patients with metal-on-metal total hip arthroplasty
verfasst von
Mitchell Bernstein
Nicholas M. Desy
Alain Petit
David J. Zukor
Olga L. Huk
John Antoniou
Publikationsdatum
01.09.2012
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 9/2012
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-012-1570-1

Weitere Artikel der Ausgabe 9/2012

International Orthopaedics 9/2012 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.