Skip to main content
Erschienen in: International Orthopaedics 12/2014

01.12.2014 | Original Paper

Clinical and radiological results of patients treated with orthogonal double plating for periprosthetic femoral fractures

verfasst von: Franz Josef Müller, Michael Galler, Bernd Füchtmeier

Erschienen in: International Orthopaedics | Ausgabe 12/2014

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The aim of this study was to determine the outcome of surgically-treated periprosthetic femoral fractures with an orthogonal double plate system.

Methods

We performed a retrospective study of ten patients (mean age 79.5 years) surgically treated for periprosthetic femoral fractures using orthogonal double plating (lateral and additional anterior plate position) from 2010 to 2013. The patients’ demographic characteristics, complications and initial follow-up data were retrieved from our institutional database. After a minimum of six months post-surgery, we performed a radiological and clinical follow-up.

Results

The surgical indications for orthogonal plating were heterogenic; five patients were treated for periprosthetic fractures around their total hip prosthesis. One was treated for a fracture around a total knee prosthesis and one for an interprosthetic fracture. Additionally, three patients were treated for postoperative implant failure after the stabilisation of periprosthetic fractures around a total hip prosthesis (one) or total knee prosthesis (two). Osteosynthesis was performed using locking compression plates exclusively (length between eight and 20 holes). After a mean follow-up of 22.6 months (range, six to 42 months), two patients died, but their deaths were due to old age morbidity and were unrelated to the surgery. Surgical revision for implant failure was necessary for only one female patient due to a breakage of the lateral plate. In addition, no other failures, such as infection or non-union, were observed. At the time of follow-up, seven out of ten patients were mobile and subjectively satisfied in regards to their outcome.

Conclusions

Based on a small number of cases, we were able to show for the first time that the use of orthogonal double plating is not associated with an increased rate of complications in patients with periprosthetic femoral fractures and stable components. Moreover, orthogonal double plating can be used successfully as a salvage procedure. At the time of follow up, seven out of ten patients were mobile. More cases must be investigated to validate our findings.
Literatur
1.
Zurück zum Zitat Duncan CP, Masri BA (1995) Fractures of the femur after hip replacement. Instr Course Lect 44:293–304PubMed Duncan CP, Masri BA (1995) Fractures of the femur after hip replacement. Instr Course Lect 44:293–304PubMed
2.
Zurück zum Zitat Parvizi J, Rapuri VR, Purtill JJ, Sharkey PF, Rothman RH, Hozack WL (2004) Treatment protocol for proximal femoral periprosthetic fractures. J Bone Joint Surg Am 86(Suppl 2):8–16PubMed Parvizi J, Rapuri VR, Purtill JJ, Sharkey PF, Rothman RH, Hozack WL (2004) Treatment protocol for proximal femoral periprosthetic fractures. J Bone Joint Surg Am 86(Suppl 2):8–16PubMed
3.
Zurück zum Zitat Bryant GK, Morshed S, Agel J et al (2009) Isolated locked compression plating for Vancouver Type B1 periprosthetic femoral fractures. Injury 40:1180–1186PubMedCrossRef Bryant GK, Morshed S, Agel J et al (2009) Isolated locked compression plating for Vancouver Type B1 periprosthetic femoral fractures. Injury 40:1180–1186PubMedCrossRef
4.
Zurück zum Zitat Laurer HL, Wutzler S, Possner S et al (2011) Outcome after operative treatment of Vancouver type B1 and C periprosthetic femoral fractures: open reduction and internal fixation versus revision arthroplasty. Arch Orthop Trauma Surg 131:983–989PubMedCrossRef Laurer HL, Wutzler S, Possner S et al (2011) Outcome after operative treatment of Vancouver type B1 and C periprosthetic femoral fractures: open reduction and internal fixation versus revision arthroplasty. Arch Orthop Trauma Surg 131:983–989PubMedCrossRef
5.
Zurück zum Zitat Fink B, Grossmann A, Singer J (2012) Hip revision arthroplasty in periprosthetic fractures of Vancouver type B2 and B3. J Orthop Trauma 26:206–211PubMedCrossRef Fink B, Grossmann A, Singer J (2012) Hip revision arthroplasty in periprosthetic fractures of Vancouver type B2 and B3. J Orthop Trauma 26:206–211PubMedCrossRef
6.
Zurück zum Zitat Neumann D, Thaler C, Dorn U (2012) Management of Vancouver B2 and B3 femoral periprosthetic fractures using a modular cementless stem without allografting. Int Orthop 36:1045–1050PubMedCentralPubMedCrossRef Neumann D, Thaler C, Dorn U (2012) Management of Vancouver B2 and B3 femoral periprosthetic fractures using a modular cementless stem without allografting. Int Orthop 36:1045–1050PubMedCentralPubMedCrossRef
7.
Zurück zum Zitat Su ET, DeWal H, Di Cesare PE (2004) Periprosthetic femoral fractures above total knee replacements. J Am Acad Orthop Surg 12:12–20PubMed Su ET, DeWal H, Di Cesare PE (2004) Periprosthetic femoral fractures above total knee replacements. J Am Acad Orthop Surg 12:12–20PubMed
8.
Zurück zum Zitat Rorabeck CH, Tayler JW (1999) Classification of periprosthetic fractures complication total knee arthroplasty. Orthop Clin N Am 30:209–214CrossRef Rorabeck CH, Tayler JW (1999) Classification of periprosthetic fractures complication total knee arthroplasty. Orthop Clin N Am 30:209–214CrossRef
9.
Zurück zum Zitat Choi JK, Gardner TR, Yoon E, Morrison TA, Macaulay WB, Geller JA (2010) The effect of fixation technique on the stiffness of comminuted Vancouver B1 periprosthetic femur fractures. J Arthroplasty 25:124–128PubMedCrossRef Choi JK, Gardner TR, Yoon E, Morrison TA, Macaulay WB, Geller JA (2010) The effect of fixation technique on the stiffness of comminuted Vancouver B1 periprosthetic femur fractures. J Arthroplasty 25:124–128PubMedCrossRef
10.
Zurück zum Zitat Dennis MG, Simon JA, Kummer FJ, Koval KJ, DiCesare PE (2000) Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem: a biomechanical study of 5 techniques. J Arthroplasty 15:523–528PubMedCrossRef Dennis MG, Simon JA, Kummer FJ, Koval KJ, DiCesare PE (2000) Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem: a biomechanical study of 5 techniques. J Arthroplasty 15:523–528PubMedCrossRef
11.
Zurück zum Zitat Ziran BH, Rohde RH, Wharton AR (2002) Lateral and anterior plating of intra-articular distal femoral fractures treated via an anterior apporach. Int Orthop 26:370–373PubMedCentralPubMedCrossRef Ziran BH, Rohde RH, Wharton AR (2002) Lateral and anterior plating of intra-articular distal femoral fractures treated via an anterior apporach. Int Orthop 26:370–373PubMedCentralPubMedCrossRef
12.
Zurück zum Zitat El Haj M, Khoury A, Mosheiff R, Liebergall M, Weil YA (2013) Orthogonal double plate fixation for long bone fracture nonunion. Acta Chir Orthop Traumatol Cech 80:131–137PubMed El Haj M, Khoury A, Mosheiff R, Liebergall M, Weil YA (2013) Orthogonal double plate fixation for long bone fracture nonunion. Acta Chir Orthop Traumatol Cech 80:131–137PubMed
13.
Zurück zum Zitat Beals RK, Tower SS (1996) Periprosthetic fractures of the femur. An analysis of 93 fractures. Clin Orthop Relat Res 327:238–246PubMedCrossRef Beals RK, Tower SS (1996) Periprosthetic fractures of the femur. An analysis of 93 fractures. Clin Orthop Relat Res 327:238–246PubMedCrossRef
14.
Zurück zum Zitat Ehlinger M, Czekaj J, Adam P, Brinkert D, Ducrot G, Bonnomet F (2013) Minimally invasive fixation of type B and C interprosthetic femoral fractures. Orthop Traumatol Surg Res 99:563–569PubMedCrossRef Ehlinger M, Czekaj J, Adam P, Brinkert D, Ducrot G, Bonnomet F (2013) Minimally invasive fixation of type B and C interprosthetic femoral fractures. Orthop Traumatol Surg Res 99:563–569PubMedCrossRef
15.
Zurück zum Zitat Demos HA, Briones MS, White PH, Hogan KA, Barfield WR (2012) A biomechanical comparison of periprosthetic femoral fracture fixation in normal and osteoporotic cadaveric bone. J Arthroplasty 27:783–788PubMedCrossRef Demos HA, Briones MS, White PH, Hogan KA, Barfield WR (2012) A biomechanical comparison of periprosthetic femoral fracture fixation in normal and osteoporotic cadaveric bone. J Arthroplasty 27:783–788PubMedCrossRef
16.
Zurück zum Zitat Wähnert D, Schröder R, Schulze M, Westerhoff P, Raschke M, Stange R (2014) Biomechanical comparison of two angular stable plate constructions for periprosthetic femur fracture fixation. Int Orthop 38:47–53PubMedCrossRef Wähnert D, Schröder R, Schulze M, Westerhoff P, Raschke M, Stange R (2014) Biomechanical comparison of two angular stable plate constructions for periprosthetic femur fracture fixation. Int Orthop 38:47–53PubMedCrossRef
17.
Zurück zum Zitat Lenz M, Windolf M, Mückley T, Hofmann GO, Wagner M, Richards RG, Schwieger K, Gueorguiev B (2012) The locking attachment plate for proximal fixation of periprosthetic femur fractures—a biomechanical comparison of two techniques. Int Orthop 36:1915–1921PubMedCentralPubMedCrossRef Lenz M, Windolf M, Mückley T, Hofmann GO, Wagner M, Richards RG, Schwieger K, Gueorguiev B (2012) The locking attachment plate for proximal fixation of periprosthetic femur fractures—a biomechanical comparison of two techniques. Int Orthop 36:1915–1921PubMedCentralPubMedCrossRef
18.
Zurück zum Zitat Bastian JD, Butscher A, Bigolin G, Zumstein M, Nötzli HP (2014) Extracortical plate fixation with new plate inserts and cerclage wires for the treatment of periprosthetic hip fractures. Int Orthop 38:489–494PubMedCrossRef Bastian JD, Butscher A, Bigolin G, Zumstein M, Nötzli HP (2014) Extracortical plate fixation with new plate inserts and cerclage wires for the treatment of periprosthetic hip fractures. Int Orthop 38:489–494PubMedCrossRef
19.
Zurück zum Zitat Zdero R, Walker R, Waddell JP et al (2008) Biomechanical evaluation of periprosthetic femoral fracture fixation. J Bone Joint Surg Am 90:1068–1077PubMedCrossRef Zdero R, Walker R, Waddell JP et al (2008) Biomechanical evaluation of periprosthetic femoral fracture fixation. J Bone Joint Surg Am 90:1068–1077PubMedCrossRef
Metadaten
Titel
Clinical and radiological results of patients treated with orthogonal double plating for periprosthetic femoral fractures
verfasst von
Franz Josef Müller
Michael Galler
Bernd Füchtmeier
Publikationsdatum
01.12.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 12/2014
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-014-2464-1

Weitere Artikel der Ausgabe 12/2014

International Orthopaedics 12/2014 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.