Skip to main content
Erschienen in: International Orthopaedics 11/2015

01.11.2015 | Original Paper

Prospective longitudinal study of one hundred patients with total hip arthroplasty using a second-generation cementless dual-mobility cup

verfasst von: Thibault Vermersch, Anthony Viste, Romain Desmarchelier, Michel-Henri Fessy

Erschienen in: International Orthopaedics | Ausgabe 11/2015

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The aim of our study was to assess the radio-clinical results, mid-term survivorship and dislocation rate of a new-generation dual-mobility cup.

Methods

The first 100 patients (104 primary total hip arthroplasties) who were implanted with a new-generation cementless dual-mobility cup (Sunfit TH, Serf, Décines) were included in our study, with a minimum follow-up of five years.

Results

Average follow-up was six years ± 0.44 (5–7). At last follow-up, the Harris and PMA scores were significantly improved, from 56 to 94 and 13 to 17 respectively (p < 0.001). No radiolucent line could be observed. There were no cases of prosthetic or intraprosthetic dislocation in our series. Survivorship without cup loosening as the endpoint was 100 %.

Conclusions

This study confirmed the interest of dual mobility in preventing prosthetic hip dislocation. Intraprosthetic dislocation is a complication that seems to have been resolved in the mid-term follow-up.
Literatur
3.
Zurück zum Zitat Berry DJ, von Knoch M, Schleck CD, Harmsen WS (2005) Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty. J Bone Joint Surg Am 87(11):2456–2463. doi:10.2106/JBJS.D.02860 CrossRefPubMed Berry DJ, von Knoch M, Schleck CD, Harmsen WS (2005) Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty. J Bone Joint Surg Am 87(11):2456–2463. doi:10.​2106/​JBJS.​D.​02860 CrossRefPubMed
4.
Zurück zum Zitat Philippot R, Camilleri JP, Boyer B, Adam P, Farizon F (2009) The use of a dual-articulation acetabular cup system to prevent dislocation after primary total hip arthroplasty: analysis of 384 cases at a mean follow-up of 15 years. Int Orthop 33(4):927–932. doi:10.1007/s00264-008-0589-9 PubMedCentralCrossRefPubMed Philippot R, Camilleri JP, Boyer B, Adam P, Farizon F (2009) The use of a dual-articulation acetabular cup system to prevent dislocation after primary total hip arthroplasty: analysis of 384 cases at a mean follow-up of 15 years. Int Orthop 33(4):927–932. doi:10.​1007/​s00264-008-0589-9 PubMedCentralCrossRefPubMed
6.
Zurück zum Zitat Charnley J, Kamangar A, Longfield MD (1969) The optimum size of prosthetic heads in relation to the wear of plastic sockets in total replacement of the hip. Med Biol Eng 7(1):31–39CrossRefPubMed Charnley J, Kamangar A, Longfield MD (1969) The optimum size of prosthetic heads in relation to the wear of plastic sockets in total replacement of the hip. Med Biol Eng 7(1):31–39CrossRefPubMed
7.
Zurück zum Zitat Lecuire F, Benareau I, Rubini J, Basso M (2004) Intra-prosthetic dislocation of the Bousquet dual mobility socket. Rev Chir Orthop Reparatrice Appar Mot 90(3):249–255CrossRefPubMed Lecuire F, Benareau I, Rubini J, Basso M (2004) Intra-prosthetic dislocation of the Bousquet dual mobility socket. Rev Chir Orthop Reparatrice Appar Mot 90(3):249–255CrossRefPubMed
8.
Zurück zum Zitat Kobayashi S, Takaoka K, Tsukada A, Ueno M (1998) Polyethylene wear from femoral bipolar neck-cup impingement as a cause of femoral prosthetic loosening. Arch Orthop Trauma Surg 117(6–7):390–391CrossRefPubMed Kobayashi S, Takaoka K, Tsukada A, Ueno M (1998) Polyethylene wear from femoral bipolar neck-cup impingement as a cause of femoral prosthetic loosening. Arch Orthop Trauma Surg 117(6–7):390–391CrossRefPubMed
9.
Zurück zum Zitat Farizon F, de Lavison R, Azoulai JJ, Bousquet G (1998) Results with a cementless alumina-coated cup with dual mobility. A twelve-year follow-up study. Int Orthop 22(4):219–224PubMedCentralCrossRefPubMed Farizon F, de Lavison R, Azoulai JJ, Bousquet G (1998) Results with a cementless alumina-coated cup with dual mobility. A twelve-year follow-up study. Int Orthop 22(4):219–224PubMedCentralCrossRefPubMed
10.
Zurück zum Zitat DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 121:20–32PubMed DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 121:20–32PubMed
11.
Zurück zum Zitat Brooker AF, Bowerman JW, Robinson RA, Riley LH Jr (1973) Ectopic ossification following total hip replacement. Incidence and a method of classification. J Bone Joint Surg Am 55(8):1629–1632PubMed Brooker AF, Bowerman JW, Robinson RA, Riley LH Jr (1973) Ectopic ossification following total hip replacement. Incidence and a method of classification. J Bone Joint Surg Am 55(8):1629–1632PubMed
12.
Zurück zum Zitat Massin P, Schmidt L, Engh CA (1989) Evaluation of cementless acetabular component migration. An experimental study. J Arthroplast 4(3):245–251CrossRef Massin P, Schmidt L, Engh CA (1989) Evaluation of cementless acetabular component migration. An experimental study. J Arthroplast 4(3):245–251CrossRef
13.
Zurück zum Zitat Bauchu P, Bonnard O, Cypres A, Fiquet A, Girardin P, Noyer D (2008) The dual-mobility POLARCUP: first results from a multicenter study. Orthopedics 31 (12 Suppl 2) Bauchu P, Bonnard O, Cypres A, Fiquet A, Girardin P, Noyer D (2008) The dual-mobility POLARCUP: first results from a multicenter study. Orthopedics 31 (12 Suppl 2)
14.
20.
Zurück zum Zitat Markel DC, Hora N, Grimm M (2002) Press-fit stability of uncemented hemispheric acetabular components: a comparison of three porous coating systems. Int Orthop 26(2):72–75PubMedCentralCrossRefPubMed Markel DC, Hora N, Grimm M (2002) Press-fit stability of uncemented hemispheric acetabular components: a comparison of three porous coating systems. Int Orthop 26(2):72–75PubMedCentralCrossRefPubMed
21.
Zurück zum Zitat Loving L, Lee RK, Herrera L, Essner AP, Nevelos JE (2013) Wear performance evaluation of a contemporary dual mobility hip bearing using multiple hip simulator testing conditions. J Arthroplast 28(6):1041–1046. doi:10.1016/j.arth.2012.09.011 CrossRef Loving L, Lee RK, Herrera L, Essner AP, Nevelos JE (2013) Wear performance evaluation of a contemporary dual mobility hip bearing using multiple hip simulator testing conditions. J Arthroplast 28(6):1041–1046. doi:10.​1016/​j.​arth.​2012.​09.​011 CrossRef
22.
25.
Zurück zum Zitat Maisongrosse P, Lepage B, Cavaignac E, Pailhe R, Reina N, Chiron P, Laffosse JM (2015) Obesity is no longer a risk factor for dislocation after total hip arthroplasty with a double-mobility cup. Int Orthop 39(7):1251–1258. doi:10.1007/s00264-014-2612-7 CrossRefPubMed Maisongrosse P, Lepage B, Cavaignac E, Pailhe R, Reina N, Chiron P, Laffosse JM (2015) Obesity is no longer a risk factor for dislocation after total hip arthroplasty with a double-mobility cup. Int Orthop 39(7):1251–1258. doi:10.​1007/​s00264-014-2612-7 CrossRefPubMed
26.
Zurück zum Zitat Berry DJ, von Knoch M, Schleck CD, Harmsen WS (2004) The cumulative long-term risk of dislocation after primary Charnley total hip arthroplasty. J Bone Joint Surg Am 86-A(1):9–14PubMed Berry DJ, von Knoch M, Schleck CD, Harmsen WS (2004) The cumulative long-term risk of dislocation after primary Charnley total hip arthroplasty. J Bone Joint Surg Am 86-A(1):9–14PubMed
Metadaten
Titel
Prospective longitudinal study of one hundred patients with total hip arthroplasty using a second-generation cementless dual-mobility cup
verfasst von
Thibault Vermersch
Anthony Viste
Romain Desmarchelier
Michel-Henri Fessy
Publikationsdatum
01.11.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 11/2015
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-015-2985-2

Weitere Artikel der Ausgabe 11/2015

International Orthopaedics 11/2015 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.