Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 1/2005

01.02.2005 | Original Article

Intraoperative cutting errors in total knee arthroplasty

verfasst von: H. Bäthis, L. Perlick, M. Tingart, C. Perlick, C. Lüring, J. Grifka

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 1/2005

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Precise reconstruction of leg alignment offers the best opportunity for achieving good long-term results in total knee arthroplasty (TKA). It was the aim of this study to evaluate the bone-cutting process as a potential source of inaccuracy in TKA.

Materials and methods

In a consecutive series of 50 computer-assisted TKAs, cutting errors, which were defined as a difference between the cutting block position before sawing and the achieved resection plane afterwards, were measured for the distal femur and proximal tibia resection. Measurements were performed using a CT-based navigation system.

Results

For the distal femoral cut, there was a mean varus/valgus deviation of 0.6° (SD±0.5°) and a mean flexion/extension deviation of 1.4° (SD±1.3°). For the proximal tibia, varus/valgus alignment showed a mean deviation of 0.5° (SD±0.5°). The mean sagittal variability was 1.0° (SD±0.9°). Differences between the frontal and the sagittal plane were significant.

Conclusion

To minimize cutting errors, techniques and instruments are needed which enable a more stable fixation of the cutting blocks or even more appropriate preparation instruments. Using a computer-assisted technique, the surgeon is aware of cutting errors occurring at each point of the operation and will therefore be able to correct these errors during surgery, while he is not aware of those errors with the conventional TKA technique.
Literatur
1.
Zurück zum Zitat Bathis H, Perlick L, Tingart M, Luring C, Perlick C, Grifka J (2004) Radiological results of image-based and non-image-based computer-assisted total knee arthroplasty. Int Orthop 28:87–90CrossRefPubMed Bathis H, Perlick L, Tingart M, Luring C, Perlick C, Grifka J (2004) Radiological results of image-based and non-image-based computer-assisted total knee arthroplasty. Int Orthop 28:87–90CrossRefPubMed
2.
Zurück zum Zitat Brys DA, Lombardi AV Jr, Mallory TH, Vaughn BK (1991) A comparison of intramedullary and extramedullary alignment systems for tibial component placement in total knee arthroplasty. Clin Orthop 263:175–179PubMed Brys DA, Lombardi AV Jr, Mallory TH, Vaughn BK (1991) A comparison of intramedullary and extramedullary alignment systems for tibial component placement in total knee arthroplasty. Clin Orthop 263:175–179PubMed
3.
Zurück zum Zitat Department of Health UK (2002) Evaluation of image guided surgery systems. Official report of the ‘Medicines and Healthcare Products Regulatory Agency’, MDA 01025 Department of Health UK (2002) Evaluation of image guided surgery systems. Official report of the ‘Medicines and Healthcare Products Regulatory Agency’, MDA 01025
4.
Zurück zum Zitat Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73:709–714PubMed Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73:709–714PubMed
5.
Zurück zum Zitat Laskin RS (2001) The Genesis total knee prosthesis: a 10-year followup study. Clin Orthop 388:95–102PubMed Laskin RS (2001) The Genesis total knee prosthesis: a 10-year followup study. Clin Orthop 388:95–102PubMed
6.
Zurück zum Zitat Lennox DW, Cohn BT, Eschenroeder HC Jr (1988) The effects of inaccurate bone cuts on femoral component position in total knee arthroplasty. Orthopedics 11:257–260PubMed Lennox DW, Cohn BT, Eschenroeder HC Jr (1988) The effects of inaccurate bone cuts on femoral component position in total knee arthroplasty. Orthopedics 11:257–260PubMed
7.
Zurück zum Zitat Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59:77–79PubMed Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59:77–79PubMed
8.
Zurück zum Zitat Mahaluxmivala J, Bankes MJ, Nicolai P, Aldam CH, Allen PW (2001) The effect of surgeon experience on component positioning in 673 press fit condylar posterior cruciate-sacrificing total knee arthroplasties. J Arthroplasty 16:635–640CrossRefPubMed Mahaluxmivala J, Bankes MJ, Nicolai P, Aldam CH, Allen PW (2001) The effect of surgeon experience on component positioning in 673 press fit condylar posterior cruciate-sacrificing total knee arthroplasties. J Arthroplasty 16:635–640CrossRefPubMed
9.
Zurück zum Zitat Matsuda S, Miura H, Nagamine R, Urabe K, Hirata G, Iwamoto Y (2001) Effect of femoral and tibial component position on patellar tracking following total knee arthroplasty: 10-year follow-up of Miller-Galante I knees. Am J Knee Surg 14:152–156PubMed Matsuda S, Miura H, Nagamine R, Urabe K, Hirata G, Iwamoto Y (2001) Effect of femoral and tibial component position on patellar tracking following total knee arthroplasty: 10-year follow-up of Miller-Galante I knees. Am J Knee Surg 14:152–156PubMed
10.
Zurück zum Zitat Minns RJ (1992) Surgical instrument design for the accurate cutting of bone for implant fixation. Clin Mater 10:207–212PubMed Minns RJ (1992) Surgical instrument design for the accurate cutting of bone for implant fixation. Clin Mater 10:207–212PubMed
11.
Zurück zum Zitat Mont MA, Urquhart MA, Hungerford DS, Krackow KA (1997) Intramedullary goniometer can improve alignment in knee arthroplasty surgery. J Arthroplasty 12:332–336CrossRefPubMed Mont MA, Urquhart MA, Hungerford DS, Krackow KA (1997) Intramedullary goniometer can improve alignment in knee arthroplasty surgery. J Arthroplasty 12:332–336CrossRefPubMed
12.
Zurück zum Zitat Otani T, Whiteside LA, White SE (1993) Cutting errors in preparation of femoral components in total knee arthroplasty. J Arthroplasty 8:503–510PubMed Otani T, Whiteside LA, White SE (1993) Cutting errors in preparation of femoral components in total knee arthroplasty. J Arthroplasty 8:503–510PubMed
13.
Zurück zum Zitat Petersen TL, Engh GA (1988) Radiographic assessment of knee alignment after total knee arthroplasty. J Arthroplasty 3:67–72PubMed Petersen TL, Engh GA (1988) Radiographic assessment of knee alignment after total knee arthroplasty. J Arthroplasty 3:67–72PubMed
14.
Zurück zum Zitat Plaskos C, Hodgson AJ, Inkpen K, McGraw RW (2002) Bone cutting errors in total knee arthroplasty. J Arthroplasty 17:698–705CrossRefPubMed Plaskos C, Hodgson AJ, Inkpen K, McGraw RW (2002) Bone cutting errors in total knee arthroplasty. J Arthroplasty 17:698–705CrossRefPubMed
15.
Zurück zum Zitat Reed SC, Gollish J (1997) The accuracy of femoral intramedullary guides in total knee arthroplasty. J Arthroplasty 12:677–682CrossRefPubMed Reed SC, Gollish J (1997) The accuracy of femoral intramedullary guides in total knee arthroplasty. J Arthroplasty 12:677–682CrossRefPubMed
16.
Zurück zum Zitat Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop 299:153–156PubMed Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop 299:153–156PubMed
17.
Zurück zum Zitat Rodriguez JA, Bhende H, Ranawat CS (2001) Total condylar knee replacement: a 20-year followup study. Clin Orthop 388:10–17CrossRefPubMed Rodriguez JA, Bhende H, Ranawat CS (2001) Total condylar knee replacement: a 20-year followup study. Clin Orthop 388:10–17CrossRefPubMed
18.
Zurück zum Zitat Scott WN, Rubinstein M, Scuderi G (1988) Results after knee replacement with a posterior cruciate-substituting prosthesis. J Bone Joint Surg Am 70:1163–1173PubMed Scott WN, Rubinstein M, Scuderi G (1988) Results after knee replacement with a posterior cruciate-substituting prosthesis. J Bone Joint Surg Am 70:1163–1173PubMed
19.
Zurück zum Zitat Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study. J Bone Joint Surg Br 85:830–835PubMed Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study. J Bone Joint Surg Br 85:830–835PubMed
20.
Zurück zum Zitat Teter KE, Bregman D, Colwell CW Jr (1995) Accuracy of intramedullary versus extramedullary tibial alignment cutting systems in total knee arthroplasty. Clin Orthop 321:106–110PubMed Teter KE, Bregman D, Colwell CW Jr (1995) Accuracy of intramedullary versus extramedullary tibial alignment cutting systems in total knee arthroplasty. Clin Orthop 321:106–110PubMed
Metadaten
Titel
Intraoperative cutting errors in total knee arthroplasty
verfasst von
H. Bäthis
L. Perlick
M. Tingart
C. Perlick
C. Lüring
J. Grifka
Publikationsdatum
01.02.2005
Verlag
Springer-Verlag
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 1/2005
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-004-0759-1

Weitere Artikel der Ausgabe 1/2005

Archives of Orthopaedic and Trauma Surgery 1/2005 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.