Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 7/2007

01.09.2007 | Trauma Surgery

Minimally invasive plating for complex humeral shaft fractures

verfasst von: Rui Jiang, Cong-Feng Luo, Bing-Fang Zeng, Guo-Hua Mei

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 7/2007

Einloggen, um Zugang zu erhalten

Abstract

Introduction

The treatment for humeral shaft fracture is still controversial, especially for complex fractures. The purpose of this study was to evaluate the clinical and radiographic outcomes of treating complex humeral shaft fractures by using locking compression plate with minimally invasive technique.

Materials and methods

A total of 21 patients with 21 acute complex humeral shaft fractures (AO type C) were included in this study. All were treated with locking compression plate in a minimally invasive way. The average age of the patients was 42.9 years and there were 14 males and 7 females. Plain radiographs of humerus were used to assess bony union. Functional recovery of the shoulder joint was assessed using the Constant and HSS scoring systems.

Results

The patients were followed for a mean of 28.7 months (range 19–37). With one operation, nineteen fractures (90.4%) achieved a solid union in an average of 14.3 weeks. At final follow-up, 20 patients (95.2%) had satisfactory alignment, except for one associated with olecranon fracture, all patients had a good to excellent elbow function with a mean HSS score of 91.7 points. Eighteen patients (85.7%) achieved satisfactory shoulder function with a mean Constant score of 83.1 points. One superficial infection (4.8%) and two non-unions (9.6%) were found postoperatively.

Conclusions

It was concluded that use of a minimally invasive plate osteosynthesis with locking compression plate is a safe alternative way to classic surgical methods in the treatment of complex humeral shaft fractures, which had a high union rate with less risk of complications.
Literatur
1.
Zurück zum Zitat Apivatthakakul T, Arpornchayanon O, Bavornratanavech S (2005) Minimally invasive plate osteosynthesis (MIPO) of the humeral shaft fracture. Is it possible? A cadaveric study and preliminary report. Injury 36:530–538PubMedCrossRef Apivatthakakul T, Arpornchayanon O, Bavornratanavech S (2005) Minimally invasive plate osteosynthesis (MIPO) of the humeral shaft fracture. Is it possible? A cadaveric study and preliminary report. Injury 36:530–538PubMedCrossRef
2.
Zurück zum Zitat Bell MJ, Beauchamp CG, Kellam JK, McMurtry RY (1985) The results of plating humeral shaft fractures in patients with multiple injuries. The Sunnybrook experience. J Bone Joint Surg Br 67:293–296PubMed Bell MJ, Beauchamp CG, Kellam JK, McMurtry RY (1985) The results of plating humeral shaft fractures in patients with multiple injuries. The Sunnybrook experience. J Bone Joint Surg Br 67:293–296PubMed
3.
Zurück zum Zitat Chen AL, Joseph TN, Wolinksy PR, Tejwani NC, Kummer FJ, Egol KA, Koval KJ (2002) Fixation stability of comminuted humeral shaft fractures: locked intramedullary nailing versus plate fixation. J Trauma 53:733–737PubMedCrossRef Chen AL, Joseph TN, Wolinksy PR, Tejwani NC, Kummer FJ, Egol KA, Koval KJ (2002) Fixation stability of comminuted humeral shaft fractures: locked intramedullary nailing versus plate fixation. J Trauma 53:733–737PubMedCrossRef
4.
Zurück zum Zitat Constant CR, Murley AH (1987) A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res 214:160–164PubMed Constant CR, Murley AH (1987) A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res 214:160–164PubMed
5.
Zurück zum Zitat Farragos AF, Schemitsch EH, McKee MD (1999) Complications of intramedullary nailing for fractures of the humeral shaft: a review. J Orthop Trauma 13:258–267PubMedCrossRef Farragos AF, Schemitsch EH, McKee MD (1999) Complications of intramedullary nailing for fractures of the humeral shaft: a review. J Orthop Trauma 13:258–267PubMedCrossRef
6.
Zurück zum Zitat Figgie MP, Inglis AE, Mow CS, Figgie HE 3rd (1989) Total elbow arthroplasty for complete ankylosis elbow. J Bone Joint Surg Am 71:513–520PubMed Figgie MP, Inglis AE, Mow CS, Figgie HE 3rd (1989) Total elbow arthroplasty for complete ankylosis elbow. J Bone Joint Surg Am 71:513–520PubMed
7.
Zurück zum Zitat Gustilo RB, Anderson JT (1976) Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones: retrospective and prospective analysis. J Bone Joint Surg Am 58:453–458PubMed Gustilo RB, Anderson JT (1976) Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones: retrospective and prospective analysis. J Bone Joint Surg Am 58:453–458PubMed
8.
Zurück zum Zitat Gautier E, Sommer C (2003) Guidelines for the clinical application of the LCP. Injury 34(Suppl 2):B63–76PubMedCrossRef Gautier E, Sommer C (2003) Guidelines for the clinical application of the LCP. Injury 34(Suppl 2):B63–76PubMedCrossRef
9.
Zurück zum Zitat Heim D, Herkert F, Hess P, Regazzoni P (1993) Surgical treatment of humeral shaft fractures—the Basel experience. J Trauma 35:226–232PubMed Heim D, Herkert F, Hess P, Regazzoni P (1993) Surgical treatment of humeral shaft fractures—the Basel experience. J Trauma 35:226–232PubMed
10.
Zurück zum Zitat Lin J, Hou SM, Hang YS, Chao EY (1997) Treatment of humeral shaft fractures by retrograde locked nailing. Clin Orthop Relat Res 342:147–155PubMedCrossRef Lin J, Hou SM, Hang YS, Chao EY (1997) Treatment of humeral shaft fractures by retrograde locked nailing. Clin Orthop Relat Res 342:147–155PubMedCrossRef
11.
Zurück zum Zitat Lin J, Hou SM (2003) Locked nailing of severely comminuted or segmental humeral fractures. Clin Orthop Relat Res 406:195–204PubMedCrossRef Lin J, Hou SM (2003) Locked nailing of severely comminuted or segmental humeral fractures. Clin Orthop Relat Res 406:195–204PubMedCrossRef
12.
Zurück zum Zitat Livani B, Belangero WD (2004) Bridging plate osteosynthesis of humeral shaft fractures. Injury 35:587–595PubMedCrossRef Livani B, Belangero WD (2004) Bridging plate osteosynthesis of humeral shaft fractures. Injury 35:587–595PubMedCrossRef
13.
Zurück zum Zitat Rosen H (1990) The treatment of nonunions and pseudarthroses of the humeral shaft. Orthop Clin North Am 21:725–742PubMed Rosen H (1990) The treatment of nonunions and pseudarthroses of the humeral shaft. Orthop Clin North Am 21:725–742PubMed
14.
Zurück zum Zitat Rhinelander FW (1987) The vascular response of bone to internal fixation. In: Browner BD, Edwards CC (eds) The science and practice of intramedullary nailing. Lea & Febiger, Philadelphia, pp 25–60 Rhinelander FW (1987) The vascular response of bone to internal fixation. In: Browner BD, Edwards CC (eds) The science and practice of intramedullary nailing. Lea & Febiger, Philadelphia, pp 25–60
15.
Zurück zum Zitat Seide K, Morlock MM, Schümann U (1999) Mechanical effects of the locked screw plate interface in internal fixator osteosyntheses. Trauma Berufskrankh 1:320–325CrossRef Seide K, Morlock MM, Schümann U (1999) Mechanical effects of the locked screw plate interface in internal fixator osteosyntheses. Trauma Berufskrankh 1:320–325CrossRef
16.
Zurück zum Zitat Shao YC, Harwood P, Grotz MR, Limb D, Giannoudis PV (2005) Radial nerve palsy associated with fractures of the shaft of the humerus: a systematic review. J Bone Joint Surg Br 87:1647–1652PubMedCrossRef Shao YC, Harwood P, Grotz MR, Limb D, Giannoudis PV (2005) Radial nerve palsy associated with fractures of the shaft of the humerus: a systematic review. J Bone Joint Surg Br 87:1647–1652PubMedCrossRef
17.
Zurück zum Zitat Wagner M, (2003) General principles for the clinical use of the LCP. Injury 34(Suppl 2):B31–42PubMedCrossRef Wagner M, (2003) General principles for the clinical use of the LCP. Injury 34(Suppl 2):B31–42PubMedCrossRef
18.
Zurück zum Zitat Yang KH (2005) Helical plate fixation for treatment of comminuted fractures of the proximal and middle one-third of the humerus. Injury 36:75–80PubMedCrossRef Yang KH (2005) Helical plate fixation for treatment of comminuted fractures of the proximal and middle one-third of the humerus. Injury 36:75–80PubMedCrossRef
Metadaten
Titel
Minimally invasive plating for complex humeral shaft fractures
verfasst von
Rui Jiang
Cong-Feng Luo
Bing-Fang Zeng
Guo-Hua Mei
Publikationsdatum
01.09.2007
Verlag
Springer-Verlag
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 7/2007
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-007-0313-z

Weitere Artikel der Ausgabe 7/2007

Archives of Orthopaedic and Trauma Surgery 7/2007 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.