Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 9/2008

01.09.2008 | Orthopaedic Outcome Assessment

Short-term wear of Japanese highly cross-linked polyethylene in cementless THA

verfasst von: Keita Miyanishi, Toshihiko Hara, Shigekazu Kaminomachi, Masayuki Maekawa, Mikio Iwamoto, Takehiko Torisu

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 9/2008

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Production of polyethylene wear from acetabular liners is thought, in part, to mediate the periprosthetic osteolysis. This study examined the in vivo wear performance of Japanese highly cross-linked polyethylene (Aeonian) in cementless total hip arthroplasty.

Matherials and methods

Ninety-five hips received a highly cross-linked polyethylene liner, while 20 hips were implanted with conventional polyethylene. Two-dimensional linear wear was measured on radiographs and volumetric wear was then calculated. Both linear and volumetric wear rates were examined for the 1-year postoperative period as well as for the time frame beginning after 1 year ending with the final follow-up.

Results

The amount of linear wear was significantly lower in the cross-linked group at 3 and 5 years postoperatively (P < 0.01 and < 0.001, respectively). Linear and volumetric wear rates after 1 year postoperatively for hips with the cross-linked polyethylene were significantly reduced by 57 and 59%, respectively, when compared to rates for those who received conventional polyethylene (P < 0.01). A multiple logistic regression analysis revealed that cross-linking was a significant factor influencing linear wear rate after 1 year postoperatively with an odds ratio, exp(ß) = 10.033 (P < 0.001).

Conclusion

These results suggest that the highly cross-linked polyethylene reduces penetration of the femoral head and may be an optimal bearing surface for patients receiving total hip arthroplasty.
Literatur
1.
Zurück zum Zitat D’Antonio JA, Manley MT, Capello WN et al (2005) Five-year experience with crossfire highly cross-linked polyethylene. Clin Orthop 441:143–150PubMedCrossRef D’Antonio JA, Manley MT, Capello WN et al (2005) Five-year experience with crossfire highly cross-linked polyethylene. Clin Orthop 441:143–150PubMedCrossRef
2.
Zurück zum Zitat Devane PA, Horne JG (1999) Assessment of polyethylene wear in total hip replacement. Clin Orthop 369:59–72PubMedCrossRef Devane PA, Horne JG (1999) Assessment of polyethylene wear in total hip replacement. Clin Orthop 369:59–72PubMedCrossRef
3.
Zurück zum Zitat Digas G, Karrholm J, Thanner J, Malchau H, Herberts P (2003) Highly cross-linked polyethylene in cemented THA: randomized study of 61 hips. Clin Orthop 417:126–138PubMed Digas G, Karrholm J, Thanner J, Malchau H, Herberts P (2003) Highly cross-linked polyethylene in cemented THA: randomized study of 61 hips. Clin Orthop 417:126–138PubMed
4.
Zurück zum Zitat Dumbleton JH, Manley MT, Edidin AA (2002) A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplasty 17:649–661PubMedCrossRef Dumbleton JH, Manley MT, Edidin AA (2002) A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplasty 17:649–661PubMedCrossRef
5.
Zurück zum Zitat Goodman SB, Lind M, Song Y, Smith RL (1998) In vitro, in vivo, and tissue retrieval studies on particulate debris. Clin Orthop 352:25–34PubMed Goodman SB, Lind M, Song Y, Smith RL (1998) In vitro, in vivo, and tissue retrieval studies on particulate debris. Clin Orthop 352:25–34PubMed
6.
Zurück zum Zitat Goodman SB, Trindade M, Ma T, Genovese M, Smith RL (2005) Pharmacologic modulation of periprosthetic osteolysis. Clin Orthop 430:39–45PubMed Goodman SB, Trindade M, Ma T, Genovese M, Smith RL (2005) Pharmacologic modulation of periprosthetic osteolysis. Clin Orthop 430:39–45PubMed
7.
Zurück zum Zitat Harris WH, McCarthy JC Jr, O’Neill DA (1982) Femoral component loosening using contemporary techniques of femoral cement fixation. J Bone Joint Surg Am 64:1063–1067PubMed Harris WH, McCarthy JC Jr, O’Neill DA (1982) Femoral component loosening using contemporary techniques of femoral cement fixation. J Bone Joint Surg Am 64:1063–1067PubMed
8.
Zurück zum Zitat Hasegawa M, Sudo A, Uchida A (2006) Alumina ceramic-on-ceramic total hip replacement with a layered acetabular component. J Bone Joint Surg Br 88:877–882PubMedCrossRef Hasegawa M, Sudo A, Uchida A (2006) Alumina ceramic-on-ceramic total hip replacement with a layered acetabular component. J Bone Joint Surg Br 88:877–882PubMedCrossRef
9.
Zurück zum Zitat Heisel C, Silva M, dela Rosa MA, Schmalzried TP (2004) Short-term in vivo wear of cross-linked polyethylene. J Bone Joint Surg Am 86:748–751PubMed Heisel C, Silva M, dela Rosa MA, Schmalzried TP (2004) Short-term in vivo wear of cross-linked polyethylene. J Bone Joint Surg Am 86:748–751PubMed
10.
Zurück zum Zitat Heisel C, Silva M, Schmalzried TP (2004) Bearing surface options for total hip replacement in young patients. Instr Course Lect 53:49–65PubMed Heisel C, Silva M, Schmalzried TP (2004) Bearing surface options for total hip replacement in young patients. Instr Course Lect 53:49–65PubMed
11.
Zurück zum Zitat Hopper RH Jr, Young AM, Orishimo KF, McAuley JP (2003) Correlation between early and late wear rates in total hip arthroplasty with application to the performance of marathon cross-linked polyethylene liners. J Arthroplasty 18(7 Suppl 1):60–67PubMedCrossRef Hopper RH Jr, Young AM, Orishimo KF, McAuley JP (2003) Correlation between early and late wear rates in total hip arthroplasty with application to the performance of marathon cross-linked polyethylene liners. J Arthroplasty 18(7 Suppl 1):60–67PubMedCrossRef
12.
Zurück zum Zitat Ikada Y, Nakamura K, Ogata S (1999) Characterization of ultrahigh molecular weight polyethylene irradiation with g-rays and electron beams to high doses. J Polym Sci Polym Chem 37:159CrossRef Ikada Y, Nakamura K, Ogata S (1999) Characterization of ultrahigh molecular weight polyethylene irradiation with g-rays and electron beams to high doses. J Polym Sci Polym Chem 37:159CrossRef
13.
Zurück zum Zitat Kabo JM, Gebhard JS, Loren G, Amstutz HC (1993) In vivo wear of polyethylene acetabular components. J Bone Joint Surg Br 75:254–258PubMed Kabo JM, Gebhard JS, Loren G, Amstutz HC (1993) In vivo wear of polyethylene acetabular components. J Bone Joint Surg Br 75:254–258PubMed
14.
Zurück zum Zitat Kurtz SM, Pruitt LA, Jewett CW, Foulds JR, Edidin AA (1999) Radiation and chemical crosslinking promote strain hardening behavior and molecular alignment in ultra high molecular weight polyethylene during multi-axial loading conditions. Biomaterials 20:1449–1462PubMedCrossRef Kurtz SM, Pruitt LA, Jewett CW, Foulds JR, Edidin AA (1999) Radiation and chemical crosslinking promote strain hardening behavior and molecular alignment in ultra high molecular weight polyethylene during multi-axial loading conditions. Biomaterials 20:1449–1462PubMedCrossRef
15.
Zurück zum Zitat Martell JM, Verner JJ, Incavo SJ (2003) Clinical performance of a highly cross-linked polyethylene at two years in total hip arthroplasty: a randomized prospective trial. J Arthroplasty 18(7 Suppl 1):55–59PubMedCrossRef Martell JM, Verner JJ, Incavo SJ (2003) Clinical performance of a highly cross-linked polyethylene at two years in total hip arthroplasty: a randomized prospective trial. J Arthroplasty 18(7 Suppl 1):55–59PubMedCrossRef
16.
Zurück zum Zitat McKellop H, Shen FW, Lu B, Campbell P, Salovey R (1999) Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. J Orthop Res 17:157–167PubMedCrossRef McKellop H, Shen FW, Lu B, Campbell P, Salovey R (1999) Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. J Orthop Res 17:157–167PubMedCrossRef
17.
Zurück zum Zitat Meneghini RM, Hallab NJ, Jacobs JJ (2005) The biology of alternative bearing surfaces in total joint arthroplasty. Instr Course Lect 54:481–493PubMed Meneghini RM, Hallab NJ, Jacobs JJ (2005) The biology of alternative bearing surfaces in total joint arthroplasty. Instr Course Lect 54:481–493PubMed
18.
Zurück zum Zitat Muratoglu OK, Mark A, Vittetoe DA, Harris WH, Rubash HE (2003) Polyethylene damage in total knees and use of highly crosslinked polyethylene. J Bone Joint Surg Am 85(Suppl 1):S7–S13PubMed Muratoglu OK, Mark A, Vittetoe DA, Harris WH, Rubash HE (2003) Polyethylene damage in total knees and use of highly crosslinked polyethylene. J Bone Joint Surg Am 85(Suppl 1):S7–S13PubMed
19.
Zurück zum Zitat Muratoglu OK, Merrill EW, Bragdon CR et al (2003) Effect of radiation, heat, and aging on in vitro wear resistance of polyethylene. Clin Orthop 417:253–262PubMed Muratoglu OK, Merrill EW, Bragdon CR et al (2003) Effect of radiation, heat, and aging on in vitro wear resistance of polyethylene. Clin Orthop 417:253–262PubMed
20.
Zurück zum Zitat Nashed RS, Becker DA, Gustilo RB (1995) Are cementless acetabular components the cause of excess wear and osteolysis in total hip arthroplasty? Clin Orthop 317:19–28PubMed Nashed RS, Becker DA, Gustilo RB (1995) Are cementless acetabular components the cause of excess wear and osteolysis in total hip arthroplasty? Clin Orthop 317:19–28PubMed
21.
Zurück zum Zitat Oonishi H, Tsuji E, Kim YY (1998) Retrieved total hip prostheses: part II. Wear behaviour and structural changes. J Mater Sci Mater Med 9:575–581PubMedCrossRef Oonishi H, Tsuji E, Kim YY (1998) Retrieved total hip prostheses: part II. Wear behaviour and structural changes. J Mater Sci Mater Med 9:575–581PubMedCrossRef
22.
Zurück zum Zitat Rohrl S, Nivbrant B, Mingguo L, Hewitt B (2005) In vivo wear and migration of highly cross-linked polyethylene cups a radiostereometry analysis study. J Arthroplasty 20:409–413PubMedCrossRef Rohrl S, Nivbrant B, Mingguo L, Hewitt B (2005) In vivo wear and migration of highly cross-linked polyethylene cups a radiostereometry analysis study. J Arthroplasty 20:409–413PubMedCrossRef
23.
Zurück zum Zitat Schmalzried TP, Callaghan JJ (1999) Wear in total hip and knee replacements. J Bone Joint Surg Am 81:115–136PubMed Schmalzried TP, Callaghan JJ (1999) Wear in total hip and knee replacements. J Bone Joint Surg Am 81:115–136PubMed
24.
Zurück zum Zitat Schmalzried TP, Huk OL (2004) Patient factors and wear in total hip arthroplasty. Clin Orthop 418:94–97PubMedCrossRef Schmalzried TP, Huk OL (2004) Patient factors and wear in total hip arthroplasty. Clin Orthop 418:94–97PubMedCrossRef
25.
Zurück zum Zitat Schmalzried TP, Jasty M, Harris WH (1992) Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space. J Bone Joint Surg Am 74:849–863PubMed Schmalzried TP, Jasty M, Harris WH (1992) Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space. J Bone Joint Surg Am 74:849–863PubMed
26.
Zurück zum Zitat Sychterz CJ, Engh CA Jr, Shah N, Engh CA Sr (1997) Radiographic evaluation of penetration by the femoral head into the polyethylene liner over time. J Bone Joint Surg Am 79:1040–1046PubMed Sychterz CJ, Engh CA Jr, Shah N, Engh CA Sr (1997) Radiographic evaluation of penetration by the femoral head into the polyethylene liner over time. J Bone Joint Surg Am 79:1040–1046PubMed
27.
Zurück zum Zitat Wroblewski BM, Siney PD, Dowson D, Collins SN (1996) Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups. J Bone Joint Surg Br 78:280–285PubMed Wroblewski BM, Siney PD, Dowson D, Collins SN (1996) Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups. J Bone Joint Surg Br 78:280–285PubMed
Metadaten
Titel
Short-term wear of Japanese highly cross-linked polyethylene in cementless THA
verfasst von
Keita Miyanishi
Toshihiko Hara
Shigekazu Kaminomachi
Masayuki Maekawa
Mikio Iwamoto
Takehiko Torisu
Publikationsdatum
01.09.2008
Verlag
Springer-Verlag
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 9/2008
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-007-0544-z

Weitere Artikel der Ausgabe 9/2008

Archives of Orthopaedic and Trauma Surgery 9/2008 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.