Abstract

Introduction

Rotator cuff tears are increasing with age. Does osteopenic bone have an influence on the pullout strength of suture anchors?

Materials and methods

SPIRALOK 5.0 mm (DePuy Mitek), Super Revo 5 mm and UltraSorb (both ConMed Linvatec) suture anchors were tested in six osteopenic and six healthy human cadaveric humeri. Incremental cyclic loading was performed. The ultimate failure load, anchor displacement, and the mode of failure were recorded.

Results

In the non-osteopenic bone group, the absorbable SPIRALOK 5.0 mm achieved a significantly better pullout strength (274 N ± 29 N, mean ± SD) than the titanium anchor Super Revo 5 mm (188 N ± 34 N, mean ± SD), and the tilting anchor UltraSorb (192 N ± 34 N, mean ± SD). In the osteopenic bone group no significant difference in the pullout strength was found. The failure mechanisms, such as anchor pullout, rupture at eyelet, suture breakage and breakage of eyelet, varied between the anchors.

Conclusion

The present study demonstrates that, in osteopenic bone, absorbable suture anchors do not have lower pullout strengths than metal anchors. In normal bone, the bioabsorbable anchor in this study even outperformed the non-absorbable anchor.
Literatur
1.
Zurück zum Zitat Barber FA, Feder SM, Burkhart SS, Ahrens J (1997) The relationship of suture anchor failure and bone density to proximal humerus location: a cadaveric study. Arthroscopy 13(3):340–345PubMed Barber FA, Feder SM, Burkhart SS, Ahrens J (1997) The relationship of suture anchor failure and bone density to proximal humerus location: a cadaveric study. Arthroscopy 13(3):340–345PubMed
2.
Zurück zum Zitat Bardana DD, Burks RT, West JR, Greis PE (2003) The effect of suture anchor design and orientation on suture abrasion: an in vitro study. Arthroscopy 19(3):274–281PubMed Bardana DD, Burks RT, West JR, Greis PE (2003) The effect of suture anchor design and orientation on suture abrasion: an in vitro study. Arthroscopy 19(3):274–281PubMed
3.
Zurück zum Zitat Bostman OM (1991) Osteolytic changes accompanying degradation of absorbable fracture fixation implants. J Bone Joint Surg Br 73(4):679–682PubMed Bostman OM (1991) Osteolytic changes accompanying degradation of absorbable fracture fixation implants. J Bone Joint Surg Br 73(4):679–682PubMed
4.
Zurück zum Zitat Burkart A, Imhoff AB, Roscher E (2000) Foreign-body reaction to the bioabsorbable suretac device. Arthroscopy 16(1):91–95PubMed Burkart A, Imhoff AB, Roscher E (2000) Foreign-body reaction to the bioabsorbable suretac device. Arthroscopy 16(1):91–95PubMed
5.
Zurück zum Zitat Burkhart SS (1995) The deadman theory of suture anchors: observations along a south Texas fence line. Arthroscopy 11(1):119–123PubMed Burkhart SS (1995) The deadman theory of suture anchors: observations along a south Texas fence line. Arthroscopy 11(1):119–123PubMed
6.
Zurück zum Zitat Burkhart SS, Diaz Pagan JL, Wirth MA, Athanasiou KA (1997) Cyclic loading of anchor-based rotator cuff repairs: confirmation of the tension overload phenomenon and comparison of suture anchor fixation with transosseous fixation. Arthroscopy 13(6):720–724PubMed Burkhart SS, Diaz Pagan JL, Wirth MA, Athanasiou KA (1997) Cyclic loading of anchor-based rotator cuff repairs: confirmation of the tension overload phenomenon and comparison of suture anchor fixation with transosseous fixation. Arthroscopy 13(6):720–724PubMed
7.
Zurück zum Zitat De Carli A, Vadala A, Monaco E, Labianca L, Zanzotto E, Ferretti A (2005) Effect of cyclic loading on new polyblend suture coupled with different anchors. Am J Sports Med 33(2):214–219PubMedCrossRef De Carli A, Vadala A, Monaco E, Labianca L, Zanzotto E, Ferretti A (2005) Effect of cyclic loading on new polyblend suture coupled with different anchors. Am J Sports Med 33(2):214–219PubMedCrossRef
8.
Zurück zum Zitat Dejong ES, DeBerardino TM, Brooks DE, Judson K (2004) In vivo comparison of a metal versus a biodegradable suture anchor. Arthroscopy 20(5):511–516PubMed Dejong ES, DeBerardino TM, Brooks DE, Judson K (2004) In vivo comparison of a metal versus a biodegradable suture anchor. Arthroscopy 20(5):511–516PubMed
9.
Zurück zum Zitat Gerber C, Schneeberger AG, Beck M, Schlegel U (1994) Mechanical strength of repairs of the rotator cuff. J Bone Joint Surg Br 76(3):371–380PubMed Gerber C, Schneeberger AG, Beck M, Schlegel U (1994) Mechanical strength of repairs of the rotator cuff. J Bone Joint Surg Br 76(3):371–380PubMed
10.
Zurück zum Zitat Hollinger JO, Battistone GC (1986) Biodegradable bone repair materials. Synthetic polymers and ceramics. Clin Orthop Relat Res (207): 290–305 Hollinger JO, Battistone GC (1986) Biodegradable bone repair materials. Synthetic polymers and ceramics. Clin Orthop Relat Res (207): 290–305
11.
Zurück zum Zitat Kaar TK, Schenck RC Jr, Wirth MA, Rockwood CA Jr (2001) Complications of metallic suture anchors in shoulder surgery: a report of 8 cases. Arthroscopy 17(1):31–37PubMed Kaar TK, Schenck RC Jr, Wirth MA, Rockwood CA Jr (2001) Complications of metallic suture anchors in shoulder surgery: a report of 8 cases. Arthroscopy 17(1):31–37PubMed
12.
Zurück zum Zitat Leedle BP, Miller MD (2005) Pullout strength of knotless suture anchors. Arthroscopy 21(1):81–85PubMed Leedle BP, Miller MD (2005) Pullout strength of knotless suture anchors. Arthroscopy 21(1):81–85PubMed
13.
Zurück zum Zitat Mahar A, Allred DW, Wedemeyer M, Abbi G, Pedowitz R (2006) A biomechanical and radiographic analysis of standard and intracortical suture anchors for arthroscopic rotator cuff repair. Arthroscopy 22(2):130–135PubMed Mahar A, Allred DW, Wedemeyer M, Abbi G, Pedowitz R (2006) A biomechanical and radiographic analysis of standard and intracortical suture anchors for arthroscopic rotator cuff repair. Arthroscopy 22(2):130–135PubMed
14.
Zurück zum Zitat McFarland EG, Park HB, Keyurapan E, Gill HS, Selhi HS (2005) Suture anchors and tacks for shoulder surgery, part 1: biology and biomechanics. Am J Sports Med 33(12):1918–1923PubMedCrossRef McFarland EG, Park HB, Keyurapan E, Gill HS, Selhi HS (2005) Suture anchors and tacks for shoulder surgery, part 1: biology and biomechanics. Am J Sports Med 33(12):1918–1923PubMedCrossRef
15.
Zurück zum Zitat Meier SW, Meier JD (2006) The effect of double-row fixation on initial repair strength in rotator cuff repair: a biomechanical study. Arthroscopy 22(11):1168–1173PubMedCrossRef Meier SW, Meier JD (2006) The effect of double-row fixation on initial repair strength in rotator cuff repair: a biomechanical study. Arthroscopy 22(11):1168–1173PubMedCrossRef
16.
Zurück zum Zitat Rickert M, Witzel U, Kolbel R, Georgousis H (2002) Primary strength of conventional and alternative suture techniques of the rotator cuff. A biomechanical study. Unfallchirurg 105(1):23–30PubMedCrossRef Rickert M, Witzel U, Kolbel R, Georgousis H (2002) Primary strength of conventional and alternative suture techniques of the rotator cuff. A biomechanical study. Unfallchirurg 105(1):23–30PubMedCrossRef
17.
Zurück zum Zitat Rupp S, Georg T, Gauss C, Kohn D, Seil R (2002) Fatigue testing of suture anchors. Am J Sports Med 30(2):239–247PubMed Rupp S, Georg T, Gauss C, Kohn D, Seil R (2002) Fatigue testing of suture anchors. Am J Sports Med 30(2):239–247PubMed
18.
Zurück zum Zitat Schneeberger AG, von Roll A, Kalberer F, Jacob HA, Gerber C (2002) Mechanical strength of arthroscopic rotator cuff repair techniques: an in vitro study. J Bone Joint Surg Am 84-A(12):2152–2160PubMed Schneeberger AG, von Roll A, Kalberer F, Jacob HA, Gerber C (2002) Mechanical strength of arthroscopic rotator cuff repair techniques: an in vitro study. J Bone Joint Surg Am 84-A(12):2152–2160PubMed
19.
Zurück zum Zitat Sher JS, Uribe JW, Posada A, Murphy BJ, Zlatkin MB (1995) Abnormal findings on magnetic resonance images of asymptomatic shoulders. J Bone Joint Surg Am 77(1):10–15PubMed Sher JS, Uribe JW, Posada A, Murphy BJ, Zlatkin MB (1995) Abnormal findings on magnetic resonance images of asymptomatic shoulders. J Bone Joint Surg Am 77(1):10–15PubMed
20.
Zurück zum Zitat Tingart MJ, Apreleva M, Lehtinen J, Zurakowski D, Warner JJ (2004) Anchor design and bone mineral density affect the pull-out strength of suture anchors in rotator cuff repair: which anchors are best to use in patients with low bone quality? Am J Sports Med 32(6):1466–1473PubMedCrossRef Tingart MJ, Apreleva M, Lehtinen J, Zurakowski D, Warner JJ (2004) Anchor design and bone mineral density affect the pull-out strength of suture anchors in rotator cuff repair: which anchors are best to use in patients with low bone quality? Am J Sports Med 32(6):1466–1473PubMedCrossRef
21.
Zurück zum Zitat Tingart MJ, Apreleva M, Zurakowski D, Warner JJ (2003) Pullout strength of suture anchors used in rotator cuff repair. J Bone Joint Surg Am 85-A(11):2190–2198PubMed Tingart MJ, Apreleva M, Zurakowski D, Warner JJ (2003) Pullout strength of suture anchors used in rotator cuff repair. J Bone Joint Surg Am 85-A(11):2190–2198PubMed
Metadaten
Titel
Suture anchor fixation strength in osteopenic versus non-osteopenic bone for rotator cuff repair
verfasst von
Matthias F. Pietschmann
Valerie Fröhlich
Andreas Ficklscherer
Mehmet F. Gülecyüz
Bernd Wegener
Volkmar Jansson
Peter E. Müller
Publikationsdatum
01.03.2009
Verlag
Springer-Verlag
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 3/2009
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-008-0689-4

Weitere Artikel der Ausgabe 3/2009

Archives of Orthopaedic and Trauma Surgery 3/2009 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.