Introduction

Pedicle screw fixation is the standard technique for the stabilization of the spine, a clinically relevant complication of which is screw loosening. This retrospective study investigates whether preoperative CT scanning can offer a predictor of screw loosening.

Methods

CT-scan attenuation in 365 patients was evaluated to determine the mean bone density of each vertebral body. Screw loosening or dislocation was determined in CT scans postoperatively using the standard radiological criteria.

Results

Forty-five of 365 patients (12.3 %; 24 male, 21 female) suffered postoperative screw loosening (62 of 2038 screws) over a mean follow-up time of 50.8 months. Revision surgeries were necessary in 23 patients (6.3 %). The correlation between decreasing mean CT attenuation in Hounsfield Units (HU) and increasing patient age was significant (p < 0.001). Mean bone density was 116.3 (SD 53.5) HU in cases with screw loosening and 132.7 (SD 41.3) HU in cases in which screws remained fixed. The difference was statistically significant (p = 0.003).

Conclusion

The determination of bone density with preoperative CT scanning can predict the risk of screw loosening and inform the decision to use cement augmentation to reduce the incidence of screw loosening.
Literatur
2.
Zurück zum Zitat Burval DJ, McLain RF, Milks R, Inceoglu S (2007) Primary pedicle screw augmentation in osteoporotic lumbar vertebrae: biomechanical analysis of pedicle fixation strength. Spine (Phila Pa 1976) 32:1077–1083. doi:10.1097/01.brs.0000261566.38422.40 Burval DJ, McLain RF, Milks R, Inceoglu S (2007) Primary pedicle screw augmentation in osteoporotic lumbar vertebrae: biomechanical analysis of pedicle fixation strength. Spine (Phila Pa 1976) 32:1077–1083. doi:10.​1097/​01.​brs.​0000261566.​38422.​40
4.
Zurück zum Zitat Coe JD, Arlet V, Donaldson W, Berven S, Hanson DS, Mudiyam R, Perra JH, Shaffrey CI (2006) Complications in spinal fusion for adolescent idiopathic scoliosis in the new millennium. A report of the Scoliosis Research Society Morbidity and Mortality Committee. Spine (Phila Pa 1976) 31:345–349. doi:10.1097/01.brs.0000197188.76369.13 Coe JD, Arlet V, Donaldson W, Berven S, Hanson DS, Mudiyam R, Perra JH, Shaffrey CI (2006) Complications in spinal fusion for adolescent idiopathic scoliosis in the new millennium. A report of the Scoliosis Research Society Morbidity and Mortality Committee. Spine (Phila Pa 1976) 31:345–349. doi:10.​1097/​01.​brs.​0000197188.​76369.​13
5.
Zurück zum Zitat Coe JD, Warden KE, Herzig MA, McAfee PC (1990) Influence of bone mineral density on the fixation of thoracolumbar implants. A comparative study of transpedicular screws, laminar hooks, and spinous process wires. Spine (Phila Pa 1976) 15:902–907 Coe JD, Warden KE, Herzig MA, McAfee PC (1990) Influence of bone mineral density on the fixation of thoracolumbar implants. A comparative study of transpedicular screws, laminar hooks, and spinous process wires. Spine (Phila Pa 1976) 15:902–907
6.
8.
Zurück zum Zitat Halvorson TL, Kelley LA, Thomas KA, Whitecloud TS, 3rd, Cook SD (1994) Effects of bone mineral density on pedicle screw fixation. Spine (Phila Pa 1976) 19:2415–2420 Halvorson TL, Kelley LA, Thomas KA, Whitecloud TS, 3rd, Cook SD (1994) Effects of bone mineral density on pedicle screw fixation. Spine (Phila Pa 1976) 19:2415–2420
9.
Zurück zum Zitat Kocak T, Cakir B, Reichel H, Mattes T (2010) Screw loosening after posterior dynamic stabilization–review of the literature. Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca 77:134–139PubMed Kocak T, Cakir B, Reichel H, Mattes T (2010) Screw loosening after posterior dynamic stabilization–review of the literature. Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca 77:134–139PubMed
10.
Zurück zum Zitat Lee S, Chung CK, Oh SH, Park SB (2013) Correlation between Bone mineral density measured by dual-energy X-Ray absorptiometry and Hounsfield units measured by diagnostic CT in Lumbar Spine. J Kor Neurosurg Soc 54:384–389. doi:10.3340/jkns.2013.54.5.384 CrossRef Lee S, Chung CK, Oh SH, Park SB (2013) Correlation between Bone mineral density measured by dual-energy X-Ray absorptiometry and Hounsfield units measured by diagnostic CT in Lumbar Spine. J Kor Neurosurg Soc 54:384–389. doi:10.​3340/​jkns.​2013.​54.​5.​384 CrossRef
11.
Zurück zum Zitat Lehman RA, Jr., Kuklo TR (2003) Use of the anatomic trajectory for thoracic pedicle screw salvage after failure/violation using the straight-forward technique: a biomechanical analysis. Spine (Phila Pa 1976) 28:2072–2077. doi:10.1097/01.BRS.0000084628.37133.BA Lehman RA, Jr., Kuklo TR (2003) Use of the anatomic trajectory for thoracic pedicle screw salvage after failure/violation using the straight-forward technique: a biomechanical analysis. Spine (Phila Pa 1976) 28:2072–2077. doi:10.​1097/​01.​BRS.​0000084628.​37133.​BA
12.
Zurück zum Zitat McAfee PC, Weiland DJ, Carlow JJ (1991) Survivorship analysis of pedicle spinal instrumentation. Spine (Phila Pa 1976) 16:S422–S427 McAfee PC, Weiland DJ, Carlow JJ (1991) Survivorship analysis of pedicle spinal instrumentation. Spine (Phila Pa 1976) 16:S422–S427
14.
Zurück zum Zitat Orphanoudakis SC, Jensen PS, Rauschkolb EN, Lang R, Rasmussen H (1979) Bone mineral analysis using single-energy computed tomography. Invest Radiol 14:122–130CrossRefPubMed Orphanoudakis SC, Jensen PS, Rauschkolb EN, Lang R, Rasmussen H (1979) Bone mineral analysis using single-energy computed tomography. Invest Radiol 14:122–130CrossRefPubMed
16.
17.
Zurück zum Zitat Schreiber JJ, Anderson PA, Rosas HG, Buchholz AL, Au AG (2011) Hounsfield units for assessing bone mineral density and strength: a tool for osteoporosis management. J Bone Joint Surg Am 93:1057–1063. doi:10.2106/JBJS.J.00160 CrossRefPubMed Schreiber JJ, Anderson PA, Rosas HG, Buchholz AL, Au AG (2011) Hounsfield units for assessing bone mineral density and strength: a tool for osteoporosis management. J Bone Joint Surg Am 93:1057–1063. doi:10.​2106/​JBJS.​J.​00160 CrossRefPubMed
18.
Zurück zum Zitat Schwaiger BJ, Gersing AS, Baum T, Noel PB, Zimmer C, Bauer JS (2014) Bone mineral density values derived from routine lumbar spine multidetector row CT predict osteoporotic vertebral fractures and screw loosening. AJNR Am J Neuroradiol 35:1628–1633. doi:10.3174/ajnr.A3893 CrossRefPubMed Schwaiger BJ, Gersing AS, Baum T, Noel PB, Zimmer C, Bauer JS (2014) Bone mineral density values derived from routine lumbar spine multidetector row CT predict osteoporotic vertebral fractures and screw loosening. AJNR Am J Neuroradiol 35:1628–1633. doi:10.​3174/​ajnr.​A3893 CrossRefPubMed
19.
Zurück zum Zitat Shea TM, Laun J, Gonzalez-Blohm SA, Doulgeris JJ, Lee WE 3rd, Aghayev K, Vrionis FD (2014) Designs and techniques that improve the pullout strength of pedicle screws in osteoporotic vertebrae: current status. Biomed Res Int 2014:748393. doi:10.1155/2014/748393 CrossRefPubMedPubMedCentral Shea TM, Laun J, Gonzalez-Blohm SA, Doulgeris JJ, Lee WE 3rd, Aghayev K, Vrionis FD (2014) Designs and techniques that improve the pullout strength of pedicle screws in osteoporotic vertebrae: current status. Biomed Res Int 2014:748393. doi:10.​1155/​2014/​748393 CrossRefPubMedPubMedCentral
21.
23.
Zurück zum Zitat Wu ZX, Gong FT, Liu L, Ma ZS, Zhang Y, Zhao X, Yang M, Lei W, Sang HX (2012) A comparative study on screw loosening in osteoporotic lumbar spine fusion between expandable and conventional pedicle screws. Arch Orthop Trauma Surg 132:471–476. doi:10.1007/s00402-011-1439-6 CrossRefPubMed Wu ZX, Gong FT, Liu L, Ma ZS, Zhang Y, Zhao X, Yang M, Lei W, Sang HX (2012) A comparative study on screw loosening in osteoporotic lumbar spine fusion between expandable and conventional pedicle screws. Arch Orthop Trauma Surg 132:471–476. doi:10.​1007/​s00402-011-1439-6 CrossRefPubMed
24.
Zurück zum Zitat Wurgler-Hauri CC, Kalbarczyk A, Wiesli M, Landolt H, Fandino J (2008) Dynamic neutralization of the lumbar spine after microsurgical decompression in acquired lumbar spinal stenosis and segmental instability. Spine (Phila Pa 1976) 33:E66–E72. doi:10.1097/BRS.0b013e31816245c0 Wurgler-Hauri CC, Kalbarczyk A, Wiesli M, Landolt H, Fandino J (2008) Dynamic neutralization of the lumbar spine after microsurgical decompression in acquired lumbar spinal stenosis and segmental instability. Spine (Phila Pa 1976) 33:E66–E72. doi:10.​1097/​BRS.​0b013e31816245c0​
25.
Zurück zum Zitat Zindrick MR, Wiltse LL, Widell EH, Thomas JC, Holland WR, Field BT, Spencer CW (1986) A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. Clin Orthop Relat Res 99–112 Zindrick MR, Wiltse LL, Widell EH, Thomas JC, Holland WR, Field BT, Spencer CW (1986) A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. Clin Orthop Relat Res 99–112
Metadaten
Titel
Predictive validity of preoperative CT scans and the risk of pedicle screw loosening in spinal surgery
verfasst von
Jan Bredow
C. K. Boese
C. M. L. Werner
J. Siewe
L. Löhrer
K. Zarghooni
P. Eysel
M. J. Scheyerer
Publikationsdatum
16.06.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 8/2016
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-016-2487-8

Weitere Artikel der Ausgabe 8/2016

Archives of Orthopaedic and Trauma Surgery 8/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.