Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 1/2017

22.12.2016 | Trauma Surgery

PEEK versus titanium locking plates for proximal humerus fracture fixation: a comparative biomechanical study in two- and three-part fractures

verfasst von: Benedikt Schliemann, Robert Seifert, Christina Theisen, Dominic Gehweiler, Dirk Wähnert, Martin Schulze, Michael J. Raschke, Andre Weimann

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 1/2017

Einloggen, um Zugang zu erhalten

Abstract

Introduction

The high rigidity of metal implants may be a cause of failure after fixation of proximal humerus fractures. Carbon fiber-reinforced polyetheretherketone (PEEK) plates with a modulus similar to human cortical bone may help to overcome this problem. The present study assesses the biomechanical behavior of a PEEK plate compared with a titanium locking plate.

Materials and methods

Unstable two- and three-part fractures were simulated in 12 pairs of cadaveric humeri and were fixed with either a PEEK or a titanium locking plate using a pairwise comparison. With an optical motion capture system, the stiffness, failure load, plate bending, and the relative motion at the bone–implant interface and at the fracture site were evaluated.

Results

The mean load to failure for two- and three-part fracture fixations was, respectively, 191 N (range 102–356 N) and 142 N (range 102–169 N) in the PEEK plate group compared with 286 N (range 191–395 N) and 258 N (range 155–366 N) in the titanium locking plate group. The PEEK plate showed significantly more bending in both the two- and three-part fractures (p < 0.05), an increased relative motion at the bone–implant interface and lower stiffness values (p < 0.05).

Conclusion

In this biomechanical study on unstable proximal humerus fractures, fixation with a PEEK plate showed lower fixation strength and increased motion at the bone–implant interface compared with a titanium locking plate.
Literatur
1.
Zurück zum Zitat Bell JE, Leung BC, Spratt KF, Koval KJ, Weinstein JD, Goodman DC, Tosteson AN (2011) Trends and variation in incidence, surgical treatment, and repeat surgery of proximal humeral fractures in the elderly. J Bone Jt Surg Am 93(2):121–131. doi:10.2106/JBJS.I.01505 CrossRef Bell JE, Leung BC, Spratt KF, Koval KJ, Weinstein JD, Goodman DC, Tosteson AN (2011) Trends and variation in incidence, surgical treatment, and repeat surgery of proximal humeral fractures in the elderly. J Bone Jt Surg Am 93(2):121–131. doi:10.​2106/​JBJS.​I.​01505 CrossRef
3.
Zurück zum Zitat Palvanen M, Kannus P, Niemi S, Parkkari J (2006) Update in the epidemiology of proximal humeral fractures. Clin Orthop Relat Res 442:87–92CrossRefPubMed Palvanen M, Kannus P, Niemi S, Parkkari J (2006) Update in the epidemiology of proximal humeral fractures. Clin Orthop Relat Res 442:87–92CrossRefPubMed
4.
Zurück zum Zitat Gupta AK, Harris JD, Erickson BJ, Abrams GD, Bruce B, McCormick F, Nicholson GP, Romeo AA (2014) Surgical management of complex proximal humerus fractures—a systematic review of 92 studies including 4500 patients. J Orthop Trauma. doi:10.1097/BOT.0000000000000229 Gupta AK, Harris JD, Erickson BJ, Abrams GD, Bruce B, McCormick F, Nicholson GP, Romeo AA (2014) Surgical management of complex proximal humerus fractures—a systematic review of 92 studies including 4500 patients. J Orthop Trauma. doi:10.​1097/​BOT.​0000000000000229​
5.
Zurück zum Zitat Schliemann B, Siemoneit J, Theisen C, Kösters C, Weimann A, Raschke MJ (2012) Complex fractures of the proximal humerus in the elderly—outcome and complications after locking plate fixation. Musculoskelet Surg 96(Suppl 1):S3–S11. doi:10.1007/s12306-012-0181-8 CrossRefPubMed Schliemann B, Siemoneit J, Theisen C, Kösters C, Weimann A, Raschke MJ (2012) Complex fractures of the proximal humerus in the elderly—outcome and complications after locking plate fixation. Musculoskelet Surg 96(Suppl 1):S3–S11. doi:10.​1007/​s12306-012-0181-8 CrossRefPubMed
8.
Zurück zum Zitat Maldonado ZM, Seebeck J, Heller MO, Brandt D, Hepp P, Lill H, Duda GN (2003) Straining of the intact and fractured proximal humerus under physiological-like loading. J Biomech 36(12):1865–1873CrossRefPubMed Maldonado ZM, Seebeck J, Heller MO, Brandt D, Hepp P, Lill H, Duda GN (2003) Straining of the intact and fractured proximal humerus under physiological-like loading. J Biomech 36(12):1865–1873CrossRefPubMed
10.
Zurück zum Zitat Epari DR, Kassi JP, Schell H, Duda GN (2007) Timely fracture-healing requires optimization of axial fixation stability. J Bone Jt Surg Am 89(7):1575–1585. doi:10.2106/JBJS.F.00247 Epari DR, Kassi JP, Schell H, Duda GN (2007) Timely fracture-healing requires optimization of axial fixation stability. J Bone Jt Surg Am 89(7):1575–1585. doi:10.​2106/​JBJS.​F.​00247
11.
Zurück zum Zitat Brunner A, Resch H, Babst R, Kathrein S, Fierlbeck J, Niederberger A, Schmolz W (2012) The Humerusblock NG: a new concept for stabilization of proximal humeral fractures and its biomechanical evaluation. Arch Orthop Trauma Surg 132(7):985–992. doi:10.1007/s00402-012-1503-x CrossRefPubMed Brunner A, Resch H, Babst R, Kathrein S, Fierlbeck J, Niederberger A, Schmolz W (2012) The Humerusblock NG: a new concept for stabilization of proximal humeral fractures and its biomechanical evaluation. Arch Orthop Trauma Surg 132(7):985–992. doi:10.​1007/​s00402-012-1503-x CrossRefPubMed
13.
Zurück zum Zitat Kralinger F, Gschwentner M, Wambacher M, Smekal V, Haid C (2008) Proximal humeral fractures: what is semi-rigid? Biomechanical properties of semi-rigid implants, a biomechanical cadaver based evaluation. Arch Orthop Trauma Surg 128(2):205–210. doi:10.1007/s00402-007-0512-7 CrossRefPubMed Kralinger F, Gschwentner M, Wambacher M, Smekal V, Haid C (2008) Proximal humeral fractures: what is semi-rigid? Biomechanical properties of semi-rigid implants, a biomechanical cadaver based evaluation. Arch Orthop Trauma Surg 128(2):205–210. doi:10.​1007/​s00402-007-0512-7 CrossRefPubMed
14.
Zurück zum Zitat Steinberg EL, Rath E, Shlaifer A, Chechik O, Maman E, Salai M (2013) Carbon fiber reinforced PEEK optima—a composite material biomechanical properties and wear/debris characteristics of CF-PEEK composites for orthopedic trauma implants. J Mech Behav Biomed Mater 17:221–228. doi:10.1016/j.jmbbm.2012.09.013 CrossRefPubMed Steinberg EL, Rath E, Shlaifer A, Chechik O, Maman E, Salai M (2013) Carbon fiber reinforced PEEK optima—a composite material biomechanical properties and wear/debris characteristics of CF-PEEK composites for orthopedic trauma implants. J Mech Behav Biomed Mater 17:221–228. doi:10.​1016/​j.​jmbbm.​2012.​09.​013 CrossRefPubMed
17.
Zurück zum Zitat Lill H, Hepp P, Korner J, Kassi JP, Verheyden AP, Josten C, Duda GN (2003) Proximal humeral fractures: how stiff should an implant be? A comparative mechanical study with new implants in human specimens. Arch Orthop Trauma Surg 123(2–3):74–81. doi:10.1007/s00402-002-0465-9 PubMed Lill H, Hepp P, Korner J, Kassi JP, Verheyden AP, Josten C, Duda GN (2003) Proximal humeral fractures: how stiff should an implant be? A comparative mechanical study with new implants in human specimens. Arch Orthop Trauma Surg 123(2–3):74–81. doi:10.​1007/​s00402-002-0465-9 PubMed
18.
Zurück zum Zitat Bottlang M, Doornink J, Byrd GD, Fitzpatrick DC, Madey SM (2009) A nonlocking end screw can decrease fracture risk caused by locked plating in the osteoporotic diaphysis. J Bone Jt Surg Am 91(3):620–627. doi:10.2106/JBJS.H.00408 CrossRef Bottlang M, Doornink J, Byrd GD, Fitzpatrick DC, Madey SM (2009) A nonlocking end screw can decrease fracture risk caused by locked plating in the osteoporotic diaphysis. J Bone Jt Surg Am 91(3):620–627. doi:10.​2106/​JBJS.​H.​00408 CrossRef
19.
Zurück zum Zitat Dietrich M, Meier C, Lattmann T, Zingg U, Gruninger P, Platz A (2008) Complex fracture of the proximal humerus in the elderly. Locking plate osteosynthesis vs hemiarthroplasty. Chirurg 79(3):231–240. doi:10.1007/s00104-007-1436-z CrossRefPubMed Dietrich M, Meier C, Lattmann T, Zingg U, Gruninger P, Platz A (2008) Complex fracture of the proximal humerus in the elderly. Locking plate osteosynthesis vs hemiarthroplasty. Chirurg 79(3):231–240. doi:10.​1007/​s00104-007-1436-z CrossRefPubMed
20.
Zurück zum Zitat Schliemann B, Hartensuer R, Koch T, Theisen C, Raschke MJ, Kösters C, Weimann A (2015) Treatment of proximal humerus fractures with a CFR-PEEK plate: 2-year-results of a prospective study and comparison to fixation with a conventional locking plate. J Shoulder Elbow Surg 24(8):1282–1288. doi:10.1016/j.jse.2014.12.028 CrossRefPubMed Schliemann B, Hartensuer R, Koch T, Theisen C, Raschke MJ, Kösters C, Weimann A (2015) Treatment of proximal humerus fractures with a CFR-PEEK plate: 2-year-results of a prospective study and comparison to fixation with a conventional locking plate. J Shoulder Elbow Surg 24(8):1282–1288. doi:10.​1016/​j.​jse.​2014.​12.​028 CrossRefPubMed
22.
Zurück zum Zitat Owsley KC, Gorczyca JT (2008) Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures [corrected]. J Bone Jt Surg Am 90(2):233–240. doi:10.2106/JBJS.F.01351 CrossRef Owsley KC, Gorczyca JT (2008) Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures [corrected]. J Bone Jt Surg Am 90(2):233–240. doi:10.​2106/​JBJS.​F.​01351 CrossRef
23.
Zurück zum Zitat Katthagen JC, Schwarze M, Meyer-Kobbe J, Voigt C, Hurschler C, Lill H (2014) Biomechanical effects of calcar screws and bone block augmentation on medial support in locked plating of proximal humeral fractures. Clin Biomech (Bristol, Avon) 29(7):735–741. doi:10.1016/j.clinbiomech.2014.06.008 CrossRef Katthagen JC, Schwarze M, Meyer-Kobbe J, Voigt C, Hurschler C, Lill H (2014) Biomechanical effects of calcar screws and bone block augmentation on medial support in locked plating of proximal humeral fractures. Clin Biomech (Bristol, Avon) 29(7):735–741. doi:10.​1016/​j.​clinbiomech.​2014.​06.​008 CrossRef
24.
26.
Zurück zum Zitat Schliemann B, Seifert R, Rosslenbroich SB, Theisen C, Wahnert D, Raschke MJ, Weimann A (2015) Screw augmentation reduces motion at the bone-implant interface: a biomechanical study of locking plate fixation of proximal humeral fractures. J Shoulder Elbow Surg 4(12):1968–1973. doi:10.1016/j.jse.2015.06.028 CrossRef Schliemann B, Seifert R, Rosslenbroich SB, Theisen C, Wahnert D, Raschke MJ, Weimann A (2015) Screw augmentation reduces motion at the bone-implant interface: a biomechanical study of locking plate fixation of proximal humeral fractures. J Shoulder Elbow Surg 4(12):1968–1973. doi:10.​1016/​j.​jse.​2015.​06.​028 CrossRef
27.
Zurück zum Zitat Kathrein S, Kralinger F, Blauth M, Schmoelz W (2013) Biomechanical comparison of an angular stable plate with augmented and non-augmented screws in a newly developed shoulder test bench. Clin Biomech (Bristol, Avon) 28(3):273–277. doi:10.1016/j.clinbiomech.2012.12.013 CrossRef Kathrein S, Kralinger F, Blauth M, Schmoelz W (2013) Biomechanical comparison of an angular stable plate with augmented and non-augmented screws in a newly developed shoulder test bench. Clin Biomech (Bristol, Avon) 28(3):273–277. doi:10.​1016/​j.​clinbiomech.​2012.​12.​013 CrossRef
28.
Zurück zum Zitat Roderer G, Gebhard F, Krischak G, Wilke HJ, Claes L (2011) Biomechanical in vitro assessment of fixed angle plating using a new concept of locking for the treatment of osteoporotic proximal humerus fractures. Int Orthop 35(4):535–541. doi:10.1007/s00264-010-1021-9 CrossRefPubMed Roderer G, Gebhard F, Krischak G, Wilke HJ, Claes L (2011) Biomechanical in vitro assessment of fixed angle plating using a new concept of locking for the treatment of osteoporotic proximal humerus fractures. Int Orthop 35(4):535–541. doi:10.​1007/​s00264-010-1021-9 CrossRefPubMed
29.
Zurück zum Zitat Euler SA, Hengg C, Wambacher M, Spiegl UJ, Kralinger F (2014) Allogenic bone grafting for augmentation in two-part proximal humeral fracture fixation in a high-risk patient population. Arch Orthop Trauma Surg. doi:10.1007/s00402-014-2128-z Euler SA, Hengg C, Wambacher M, Spiegl UJ, Kralinger F (2014) Allogenic bone grafting for augmentation in two-part proximal humeral fracture fixation in a high-risk patient population. Arch Orthop Trauma Surg. doi:10.​1007/​s00402-014-2128-z
32.
34.
Zurück zum Zitat Zhu L, Liu Y, Yang Z, Li H, Wang J, Zhao C, Chen X, Zhang Y (2014) Locking plate fixation combined with iliac crest bone autologous graft for proximal humerus comminuted fracture. Chin Med J 127(9):1672–1676PubMed Zhu L, Liu Y, Yang Z, Li H, Wang J, Zhao C, Chen X, Zhang Y (2014) Locking plate fixation combined with iliac crest bone autologous graft for proximal humerus comminuted fracture. Chin Med J 127(9):1672–1676PubMed
36.
Zurück zum Zitat Katthagen JC, Schwarze M, Warnhoff M, Voigt C, Hurschler C, Lill H (2016) Influence of plate material and screw design on stiffness and ultimate load of locked plating in osteoporotic proximal humeral fractures. Injury 47(3):617–624. doi:10.1016/j.injury.2016.01.004 CrossRefPubMed Katthagen JC, Schwarze M, Warnhoff M, Voigt C, Hurschler C, Lill H (2016) Influence of plate material and screw design on stiffness and ultimate load of locked plating in osteoporotic proximal humeral fractures. Injury 47(3):617–624. doi:10.​1016/​j.​injury.​2016.​01.​004 CrossRefPubMed
Metadaten
Titel
PEEK versus titanium locking plates for proximal humerus fracture fixation: a comparative biomechanical study in two- and three-part fractures
verfasst von
Benedikt Schliemann
Robert Seifert
Christina Theisen
Dominic Gehweiler
Dirk Wähnert
Martin Schulze
Michael J. Raschke
Andre Weimann
Publikationsdatum
22.12.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 1/2017
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-016-2620-8

Weitere Artikel der Ausgabe 1/2017

Archives of Orthopaedic and Trauma Surgery 1/2017 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.