Skip to main content
Erschienen in: European Spine Journal 5/2003

01.10.2003 | Original Article

Biomechanical evaluation of a bipedicular spinal fixation device: three different strength tests

verfasst von: Laurent Balabaud, Emeric Gallard, Wafa Skalli, Bernard Dupas, Robert Roger, François Lavaste, Jean-Paul Steib

Erschienen in: European Spine Journal | Ausgabe 5/2003

Einloggen, um Zugang zu erhalten

Abstract

Disadvantages of thoracic posterior implants and developments in rod contouring in situ led to the design of a new spinal implant: the bipedicular spinal fixation device (BSF). The BSF is composed of two bifid hooks linked by a compression transverse connector and inserted into the costo-vertebral and costo-transverse joints. The aim of this biomechanical study was to determine the loading tolerance of the BSF. Three strength tests—a pull-out test, a lateral load-to-failure test and a uniaxial transversal compression test to failure—were performed using six human thoracic spines on an Instron testing device. Specimen evaluation consisted of: bone mineral density (BMD) measurement with the dual-energy X-ray absorptiometry (DEXA) technique, cortical thickness measurements and a morphometric study. The mean values for load-to-failure in the posterior and lateral tests were 324 N and 400 N respectively. The mean value of the uniaxial compression was 988 N. The mean BMD estimated by DEXA was 0.557 g/cm2. The BSF loading tolerance was compatible with the in situ rod contouring technique requirements when we considered posterior and lateral pull-out tests. The transversal compression test determined the appropriate and efficient BSF tightening force.
Literatur
1.
Zurück zum Zitat Balabaud L, Gallard E, Skalli W, Lassau JP, Lavaste F, Steib JP (2002) Biomechanical evaluation of a bipedicular spinal fixation system. A comparative stiffness test. Spine 27:1875–1880PubMed Balabaud L, Gallard E, Skalli W, Lassau JP, Lavaste F, Steib JP (2002) Biomechanical evaluation of a bipedicular spinal fixation system. A comparative stiffness test. Spine 27:1875–1880PubMed
2.
Zurück zum Zitat Berlemann U, Cripton P, Nolte L-P, Lippuner K, Schläpfer F (1995) New means in spinal pedicle hook fixation. Eur Spine J 4:114–122PubMed Berlemann U, Cripton P, Nolte L-P, Lippuner K, Schläpfer F (1995) New means in spinal pedicle hook fixation. Eur Spine J 4:114–122PubMed
3.
Zurück zum Zitat Berry JL, Moran JM, Berg WS, Steffee AD (1987) A morphological study of human lumbar and selected thoracic vertebrae. Spine 12:362–367PubMed Berry JL, Moran JM, Berg WS, Steffee AD (1987) A morphological study of human lumbar and selected thoracic vertebrae. Spine 12:362–367PubMed
4.
Zurück zum Zitat Breeze SW, Doherty BJ, Noble PS, LeBlanc A, Heggeness MH (1998) A biomechanical study of anterior thoracolumbar screw fixation. Spine 23:1829–1831PubMed Breeze SW, Doherty BJ, Noble PS, LeBlanc A, Heggeness MH (1998) A biomechanical study of anterior thoracolumbar screw fixation. Spine 23:1829–1831PubMed
5.
Zurück zum Zitat Coe JD, Warden KE, Herzig MA, McAfee PC (1990) Influence of bone mineral density on the fixation of thoracolumbar implants. A comparative study of transpedicular screws, laminar hooks, and spinous process wires. Spine 15:902–907PubMed Coe JD, Warden KE, Herzig MA, McAfee PC (1990) Influence of bone mineral density on the fixation of thoracolumbar implants. A comparative study of transpedicular screws, laminar hooks, and spinous process wires. Spine 15:902–907PubMed
6.
Zurück zum Zitat Cotrel Y, Dubousset J (1984) Nouvelle technique d'ostéosynthèse rachidienne segmentaire par voie postérieure. Rev Chir Orthop 70:489–494PubMed Cotrel Y, Dubousset J (1984) Nouvelle technique d'ostéosynthèse rachidienne segmentaire par voie postérieure. Rev Chir Orthop 70:489–494PubMed
7.
Zurück zum Zitat Dvorak M, McDonald S, Gurr KR, Bailey SI, Haddad RG (1993) An anatomic, radiographic, and biomechanical assessment of extrapedicular screw fixation in the thoracic spine. Spine 18:1689–1694PubMed Dvorak M, McDonald S, Gurr KR, Bailey SI, Haddad RG (1993) An anatomic, radiographic, and biomechanical assessment of extrapedicular screw fixation in the thoracic spine. Spine 18:1689–1694PubMed
8.
Zurück zum Zitat Harrington PR (1962) Treatment of scoliosis. Correction and internal fixation by spine instrumentation. J Bone Joint Surg Am 44:591–610 Harrington PR (1962) Treatment of scoliosis. Correction and internal fixation by spine instrumentation. J Bone Joint Surg Am 44:591–610
9.
Zurück zum Zitat Heller JG, Shuster JK, Hutton WC (1999) Pedicle and transverse process screws of the upper thoracic spine. Spine 24:654–658CrossRefPubMed Heller JG, Shuster JK, Hutton WC (1999) Pedicle and transverse process screws of the upper thoracic spine. Spine 24:654–658CrossRefPubMed
10.
Zurück zum Zitat Kim N-H, Lee H-M, Chung I-H, Kim H-J, Kim S-J (1994) Morphometric study of the pedicles of thoracic and lumbar vertebrae in Koreans. Spine 19:1390–1394PubMed Kim N-H, Lee H-M, Chung I-H, Kim H-J, Kim S-J (1994) Morphometric study of the pedicles of thoracic and lumbar vertebrae in Koreans. Spine 19:1390–1394PubMed
11.
Zurück zum Zitat Krag MH, Weaver DL, Beynnon BD, Haugh LD (1988) Morphometry of the thoracic and lumbar spine related to transpedicular screw placement for surgical spinal fixation. Spine 13:27–32PubMed Krag MH, Weaver DL, Beynnon BD, Haugh LD (1988) Morphometry of the thoracic and lumbar spine related to transpedicular screw placement for surgical spinal fixation. Spine 13:27–32PubMed
12.
Zurück zum Zitat Lambert de Cursay G, Azais O, Bontoux D (1992) Arthrose inter-apophysaire lombaire et contenu minéral osseux: étude prospective versus témoins par absorptiométrie di-photonique et tomodensitométrie. Rev Rhum Mal Ostéoartic 59:311–316 Lambert de Cursay G, Azais O, Bontoux D (1992) Arthrose inter-apophysaire lombaire et contenu minéral osseux: étude prospective versus témoins par absorptiométrie di-photonique et tomodensitométrie. Rev Rhum Mal Ostéoartic 59:311–316
13.
Zurück zum Zitat Laporte S, Mitton D, Ismaël B, de Fouchecour M, Lasseau JP, Lavaste F, Skalli W (2000) Quantitative morphometric study of thoracic spine. A preliminary parameters statistical analysis. Eur Spine J 10:85–91 Laporte S, Mitton D, Ismaël B, de Fouchecour M, Lasseau JP, Lavaste F, Skalli W (2000) Quantitative morphometric study of thoracic spine. A preliminary parameters statistical analysis. Eur Spine J 10:85–91
14.
Zurück zum Zitat Luque ER (1982) The anatomic basis and development of segmental spinal instrumentation. Spine 7:256–259PubMed Luque ER (1982) The anatomic basis and development of segmental spinal instrumentation. Spine 7:256–259PubMed
15.
Zurück zum Zitat Orwoll ES, Oviatt SK, Mann T (1990) The impact of osteophytic and vascular calcifications on vertebral mineral density measurements in men. J Clin Endocrinol Metab 70:1202–1207PubMed Orwoll ES, Oviatt SK, Mann T (1990) The impact of osteophytic and vascular calcifications on vertebral mineral density measurements in men. J Clin Endocrinol Metab 70:1202–1207PubMed
16.
Zurück zum Zitat Panjabi MM, Takata K, Goel V, Federico D, Oxland T, Duranceau J, Krag M (1991) Thoracic human vertebrae. Quantitative three-dimensional anatomy. Spine 16:888–901PubMed Panjabi MM, Takata K, Goel V, Federico D, Oxland T, Duranceau J, Krag M (1991) Thoracic human vertebrae. Quantitative three-dimensional anatomy. Spine 16:888–901PubMed
17.
Zurück zum Zitat Roy-Camille R, Demeulenaere C (1970) Ostéosynthèse du rachis dorsal, lombaire et lombo-sacré par plaque métallique vissée dans les pédicules vertébraux et les apophyses articulaires. Presse Méd 78:1447–1448 Roy-Camille R, Demeulenaere C (1970) Ostéosynthèse du rachis dorsal, lombaire et lombo-sacré par plaque métallique vissée dans les pédicules vertébraux et les apophyses articulaires. Presse Méd 78:1447–1448
18.
Zurück zum Zitat Roy-Camille R, Garcon P, Begue Th (1990) Techniques chirurgicales. Etude biomécanique de l'ancrage des vis pédiculaires dorsales et lombaires. 7èmes Journées de la Pitié-Salpétrières, Paris, pp 29–35 Roy-Camille R, Garcon P, Begue Th (1990) Techniques chirurgicales. Etude biomécanique de l'ancrage des vis pédiculaires dorsales et lombaires. 7èmes Journées de la Pitié-Salpétrières, Paris, pp 29–35
19.
Zurück zum Zitat Ruland CM, McAfee PC, Warden KE, Cunningham BW (1991) Triangulation of pedicular instrumentation. A biomechanical analysis. Spine 16 [6 Suppl]:270–276 Ruland CM, McAfee PC, Warden KE, Cunningham BW (1991) Triangulation of pedicular instrumentation. A biomechanical analysis. Spine 16 [6 Suppl]:270–276
20.
Zurück zum Zitat Scoles PV, Linton AE, Latimer B, Levy ME, Digiovanni BF (1988) Vertebral body and posterior element morphology: the normal spine in middle life. Spine 13:1082–1086PubMed Scoles PV, Linton AE, Latimer B, Levy ME, Digiovanni BF (1988) Vertebral body and posterior element morphology: the normal spine in middle life. Spine 13:1082–1086PubMed
21.
Zurück zum Zitat Stanescu S, Ebraheim NA, Yeasting R, Bailey AS, Jackson T (1994) Morphometric evaluation of the cervico-thoracic junction. Spine 19:2082–2088PubMed Stanescu S, Ebraheim NA, Yeasting R, Bailey AS, Jackson T (1994) Morphometric evaluation of the cervico-thoracic junction. Spine 19:2082–2088PubMed
22.
Zurück zum Zitat Steib JP (1997) Instrumentation "SCS". In: Pous, Les instrumentations rachidiennes. Cahiers d'enseignement de la SOFCOT, Expansion Scientifique Française, Paris, pp 121–124 Steib JP (1997) Instrumentation "SCS". In: Pous, Les instrumentations rachidiennes. Cahiers d'enseignement de la SOFCOT, Expansion Scientifique Française, Paris, pp 121–124
23.
Zurück zum Zitat Voor MJ, Roberts CS, Rose SM, Glassman SD (1997) Biomechanics of in situ rod contouring of short-segment pedicle screw instrumentation in the thoracolumbar spine. J Spinal Dis 10:106–116 Voor MJ, Roberts CS, Rose SM, Glassman SD (1997) Biomechanics of in situ rod contouring of short-segment pedicle screw instrumentation in the thoracolumbar spine. J Spinal Dis 10:106–116
24.
Zurück zum Zitat Yerby SA, Ehteshami JR, McLain RF (1997) Offset laminar hooks decrease bending moments of pedicle screws during in situ contouring. Spine 22:376–381CrossRefPubMed Yerby SA, Ehteshami JR, McLain RF (1997) Offset laminar hooks decrease bending moments of pedicle screws during in situ contouring. Spine 22:376–381CrossRefPubMed
25.
Zurück zum Zitat Zindrick MR, Wiltse LL, Doornick A, Widell EH, Knight GW, Patwardhan AG, Thomas JC, Rothman SL, Fields BT (1987) Analysis of the morphometric characteristics of the thoracic and lumbar pedicles. Spine 12:160–166PubMed Zindrick MR, Wiltse LL, Doornick A, Widell EH, Knight GW, Patwardhan AG, Thomas JC, Rothman SL, Fields BT (1987) Analysis of the morphometric characteristics of the thoracic and lumbar pedicles. Spine 12:160–166PubMed
Metadaten
Titel
Biomechanical evaluation of a bipedicular spinal fixation device: three different strength tests
verfasst von
Laurent Balabaud
Emeric Gallard
Wafa Skalli
Bernard Dupas
Robert Roger
François Lavaste
Jean-Paul Steib
Publikationsdatum
01.10.2003
Verlag
Springer-Verlag
Erschienen in
European Spine Journal / Ausgabe 5/2003
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-002-0520-9

Weitere Artikel der Ausgabe 5/2003

European Spine Journal 5/2003 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.