Skip to main content
Erschienen in: European Spine Journal 5/2007

01.05.2007 | Original Article

Computer tomography assessment of pedicle screw insertion in percutaneous posterior transpedicular stabilization

verfasst von: Constantin Schizas, Jacky Michel, Victor Kosmopoulos, Nicolas Theumann

Erschienen in: European Spine Journal | Ausgabe 5/2007

Einloggen, um Zugang zu erhalten

Abstract

Percutaneous insertion of cannulated pedicle screws has been recently developed as a minimally invasive alternative to the open technique during instrumented fusion procedures. Given the reported rate of screw misplacement using open techniques (up to 40%), we considered it important to analyze possible side effects of this new technique. Placement of 60 pedicle screws in 15 consecutive patients undergoing lumbar or lumbosacral fusion, mainly for spondylolisthesis, were analyzed. Axial, coronal, and sagittal reformatted computer tomography images were examined by three observers. Individual and consensus interpretation was obtained for each screw position. Along with frank penetration, we also looked at cortical encroachment of the pedicular wall by the screw. Thirteen percent of the patients (2/15) had severe frank penetration from the screws, while 80% of them (12/15) had some perforation. On axial images the incidence of severe frank pedicle penetration was 3.3% while the overall rate of screw perforation was 23%. In coronal images the overall screw perforation rate rose to 30% while the rate of severe frank pedicle penetration remained unchanged. One patient (6.6%) suffered S1 root symptoms due to a frankly medially misplaced screw, requiring re-operation. This study has shown that percutaneous insertion of cannulated pedicle screws in the lumbar spine is an acceptable procedure. The overall rate of perforation in axial images is below the higher rates reported in the literature but does remain important. Frank penetration of the pedicle was nevertheless low. It remains a demanding technique and has to be performed with extreme care to detail.
Literatur
1.
Zurück zum Zitat Castro WH, Halm H, Jerosch J, Malms J, Steinbeck J, Blasius S (1996) Accuracy of pedicle screw placement in lumbar vertebrae. Spine 21:1320–1324PubMedCrossRef Castro WH, Halm H, Jerosch J, Malms J, Steinbeck J, Blasius S (1996) Accuracy of pedicle screw placement in lumbar vertebrae. Spine 21:1320–1324PubMedCrossRef
2.
Zurück zum Zitat Esses SI, Botsford DJ, Kostuik JP (1989) The role of external spinal skeletal fixation in the assessment of low-back disorders. Spine 14:594–601PubMedCrossRef Esses SI, Botsford DJ, Kostuik JP (1989) The role of external spinal skeletal fixation in the assessment of low-back disorders. Spine 14:594–601PubMedCrossRef
3.
Zurück zum Zitat Farber GL, Place HM, Mazur RA, Jones DE, Damiano TR (1995) Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography. Spine 20:1494–1499PubMedCrossRef Farber GL, Place HM, Mazur RA, Jones DE, Damiano TR (1995) Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography. Spine 20:1494–1499PubMedCrossRef
4.
Zurück zum Zitat Foley KT, Gupta SK (2002) Percutaneous pedicle screw fixation of the lumbar spine: preliminary clinical results. J Neurosurg 97:7–12PubMed Foley KT, Gupta SK (2002) Percutaneous pedicle screw fixation of the lumbar spine: preliminary clinical results. J Neurosurg 97:7–12PubMed
5.
Zurück zum Zitat Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine 15:11–14PubMedCrossRef Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine 15:11–14PubMedCrossRef
6.
Zurück zum Zitat Holly LT, Foley KT (2003) Three-dimensional fluoroscopy-guided percutaneous thoracolumbar pedicle screw placement. Technical note. J Neurosurg 99:324–329PubMed Holly LT, Foley KT (2003) Three-dimensional fluoroscopy-guided percutaneous thoracolumbar pedicle screw placement. Technical note. J Neurosurg 99:324–329PubMed
7.
Zurück zum Zitat Khoo LT, Palmer S, Laich DT, Fessler RG (2002) Minimally invasive percutaneous posterior lumbar interbody fusion (see comment). Neurosurgery 51:S166–S171PubMed Khoo LT, Palmer S, Laich DT, Fessler RG (2002) Minimally invasive percutaneous posterior lumbar interbody fusion (see comment). Neurosurgery 51:S166–S171PubMed
8.
Zurück zum Zitat Kim YJ, Lenke LG, Cheh G, Riew KD (2005) Evaluation of pedicle screw placement in the deformed spine using intraoperative plain radiographs: a comparison with computerized tomography. Spine 30:2084–2088PubMedCrossRef Kim YJ, Lenke LG, Cheh G, Riew KD (2005) Evaluation of pedicle screw placement in the deformed spine using intraoperative plain radiographs: a comparison with computerized tomography. Spine 30:2084–2088PubMedCrossRef
9.
Zurück zum Zitat Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D (2000) Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients (see comment). Eur Spine J 9:235–240PubMedCrossRef Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D (2000) Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients (see comment). Eur Spine J 9:235–240PubMedCrossRef
10.
Zurück zum Zitat Laine T, Makitalo K, Schlenzka D, Tallroth K, Poussa M, Alho A (1997) Accuracy of pedicle screw insertion: a prospective CT study in 30 low back patients. Eur Spine J 6:402–405PubMedCrossRef Laine T, Makitalo K, Schlenzka D, Tallroth K, Poussa M, Alho A (1997) Accuracy of pedicle screw insertion: a prospective CT study in 30 low back patients. Eur Spine J 6:402–405PubMedCrossRef
11.
Zurück zum Zitat Laine T, Schlenzka D, Makitalo K, Tallroth K, Nolte LP, Visarius H (1997) Improved accuracy of pedicle screw insertion with computer-assisted surgery A prospective clinical trial of 30 patients. Spine 22:1254–1258PubMedCrossRef Laine T, Schlenzka D, Makitalo K, Tallroth K, Nolte LP, Visarius H (1997) Improved accuracy of pedicle screw insertion with computer-assisted surgery A prospective clinical trial of 30 patients. Spine 22:1254–1258PubMedCrossRef
12.
Zurück zum Zitat Learch TJ, Massie JB, Pathria MN, Ahlgren BA, Garfin SR (2004) Assessment of pedicle screw placement utilizing conventional radiography and computed tomography: a proposed systematic approach to improve accuracy of interpretation. Spine 29:767–773PubMedCrossRef Learch TJ, Massie JB, Pathria MN, Ahlgren BA, Garfin SR (2004) Assessment of pedicle screw placement utilizing conventional radiography and computed tomography: a proposed systematic approach to improve accuracy of interpretation. Spine 29:767–773PubMedCrossRef
13.
Zurück zum Zitat Magerl FP (1984) Stabilization of the lower thoracic and lumbar spine with external skeletal fixation. Clin Orthop Relat Res 189:125–141PubMed Magerl FP (1984) Stabilization of the lower thoracic and lumbar spine with external skeletal fixation. Clin Orthop Relat Res 189:125–141PubMed
14.
Zurück zum Zitat Roy-Camille R, Saillant G, Mazel C (1986) Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop Relat Res 203:7–17PubMed Roy-Camille R, Saillant G, Mazel C (1986) Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop Relat Res 203:7–17PubMed
15.
Zurück zum Zitat Schulze CJ, Munzinger E, Weber U (1998) Clinical relevance of accuracy of pedicle screw placement. A computed tomographic-supported analysis. Spine 23:2215–2220PubMedCrossRef Schulze CJ, Munzinger E, Weber U (1998) Clinical relevance of accuracy of pedicle screw placement. A computed tomographic-supported analysis. Spine 23:2215–2220PubMedCrossRef
16.
Zurück zum Zitat Schwender JD, Holly LT, Rouben DP, Foley KT (2005) Minimally invasive transforaminal lumbar interbody fusion (TLIF): technical feasibility and initial results. J Spinal Disord Techn 18(Suppl):S1–S6CrossRef Schwender JD, Holly LT, Rouben DP, Foley KT (2005) Minimally invasive transforaminal lumbar interbody fusion (TLIF): technical feasibility and initial results. J Spinal Disord Techn 18(Suppl):S1–S6CrossRef
17.
Zurück zum Zitat Wiesner L, Kothe R, Ruther W (1999) Anatomic evaluation of two different techniques for the percutaneous insertion of pedicle screws in the lumbar spine. Spine 24:1599–1603PubMedCrossRef Wiesner L, Kothe R, Ruther W (1999) Anatomic evaluation of two different techniques for the percutaneous insertion of pedicle screws in the lumbar spine. Spine 24:1599–1603PubMedCrossRef
18.
Zurück zum Zitat Wiesner L, Kothe R, Schulitz KP, Ruther W (2000) Clinical evaluation and computed tomography scan analysis of screw tracts after percutaneous insertion of pedicle screws in the lumbar spine. Spine 25:615–621PubMedCrossRef Wiesner L, Kothe R, Schulitz KP, Ruther W (2000) Clinical evaluation and computed tomography scan analysis of screw tracts after percutaneous insertion of pedicle screws in the lumbar spine. Spine 25:615–621PubMedCrossRef
Metadaten
Titel
Computer tomography assessment of pedicle screw insertion in percutaneous posterior transpedicular stabilization
verfasst von
Constantin Schizas
Jacky Michel
Victor Kosmopoulos
Nicolas Theumann
Publikationsdatum
01.05.2007
Verlag
Springer-Verlag
Erschienen in
European Spine Journal / Ausgabe 5/2007
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-006-0221-x

Weitere Artikel der Ausgabe 5/2007

European Spine Journal 5/2007 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.