Skip to main content
Erschienen in: European Spine Journal 1/2008

01.01.2008 | Original Article

Analysis of post-operative pain patterns following total lumbar disc replacement: results from fluoroscopically guided spine infiltrations

verfasst von: Christoph J. Siepe, Andreas Korge, Frank Grochulla, Christoph Mehren, H. Michael Mayer

Erschienen in: European Spine Journal | Ausgabe 1/2008

Einloggen, um Zugang zu erhalten

Abstract

Although a variety of biomechanical laboratory investigations and radiological studies have highlighted the potential problems associated with total lumbar disc replacement (TDR), no previous study has performed a systematic clinical failure analysis. The aim of this study was to identify the post-operative pain sources, establish the incidence of post-operative pain patterns and investigate the effect on post-operative outcome with the help of fluoroscopically guided spine infiltrations in patients from an ongoing prospective study with ProDisc II. Patients who reported unsatisfactory results at any of the FU-examinations received fluoroscopically guided spine infiltrations as part of a semi-invasive diagnostic and conservative treatment program. Pain sources were identified in patients with reproducible (≥2×) significant (50–75%) or highly significant (75–100%) pain relief. Results were correlated with outcome parameters visual analogue scale (VAS), Oswestry disability index (ODI) and the subjective patient satisfaction rate. From a total of 175 operated patients with a mean follow-up (FU) of 29.3 months (range 12.2–74.9 months), n = 342 infiltrations were performed in n = 58 patients (33.1%) overall. Facet joint pain, predominantly at the index level (86.4%), was identified in n = 22 patients (12.6%). The sacroiliac joint was a similarly frequent cause of post-operative pain (n = 21, 12.0%). Pain from both structures influenced all outcome parameters negatively (P < 0.05). Patients with an early onset of pain (≤6 months) were 2–5× higher at risk of developing persisting complaints and unsatisfactory outcome at later FU-stages in comparison to the entire study cohort (P < 0.05). The level of TDR significantly influenced post-operative outcome. Best results were achieved for the TDRs above the lumbosacral junction at L4/5 (incidence of posterior joint pain 14.8%). Inferior outcome and a significantly higher incidence of posterior joint pain were observed for TDR at L5/S1 (21.6%) and bisegmental TDR at L4/5/S1 (33.3%), respectively. Lumbar facet and/or ISJ-pain are a frequent and currently underestimated source of post-operative pain and the most common reasons for unsatisfactory results following TDR. Further failure-analysis studies are required and adequate salvage treatment options need to be established with respect to the underlying pathology of post-operative pain. The question as to whether or not TDR will reduce the incidence of posterior joint pain, which has been previously attributed to lumbar fusion procedures, remains unanswered. Additional studies will have to investigate whether TDR compromises the index-segment in an attempt to avoid adjacent segment degeneration.
Literatur
1.
Zurück zum Zitat Akamaru T, Kawahara N, Tim Yoon S, Minamide A, Su Kim K, Tomita K, Hutton WC (2003) Adjacent segment motion after a simulated lumbar fusion in different sagittal alignments: a biomechanical analysis. Spine 28:1560–1566PubMedCrossRef Akamaru T, Kawahara N, Tim Yoon S, Minamide A, Su Kim K, Tomita K, Hutton WC (2003) Adjacent segment motion after a simulated lumbar fusion in different sagittal alignments: a biomechanical analysis. Spine 28:1560–1566PubMedCrossRef
2.
Zurück zum Zitat Bertagnoli R, Marnay T, Mayer HM (2003) The Prodisc book. Spine solutions GmbH, Tuttlingen Bertagnoli R, Marnay T, Mayer HM (2003) The Prodisc book. Spine solutions GmbH, Tuttlingen
3.
Zurück zum Zitat Block AR, Vanharanta H, Ohnmeiss DD, Guyer RD (1996) Discographic pain report. Influence of psychological factors. Spine 21:334–338PubMedCrossRef Block AR, Vanharanta H, Ohnmeiss DD, Guyer RD (1996) Discographic pain report. Influence of psychological factors. Spine 21:334–338PubMedCrossRef
4.
Zurück zum Zitat Blumenthal S, McAfee PC, Guyer RD, Hochschuler SH, Geisler FH, Holt RT, Garcia R Jr, Regan JJ, Ohnmeiss DD (2005) A prospective, randomized, multicenter food and drug administration investigational device exemptions study of lumbar total disc replacement with the CHARITE artificial disc versus lumbar fusion: part I: evaluation of clinical outcomes. Spine 30:1565–1575; discussion E1387–E1591PubMedCrossRef Blumenthal S, McAfee PC, Guyer RD, Hochschuler SH, Geisler FH, Holt RT, Garcia R Jr, Regan JJ, Ohnmeiss DD (2005) A prospective, randomized, multicenter food and drug administration investigational device exemptions study of lumbar total disc replacement with the CHARITE artificial disc versus lumbar fusion: part I: evaluation of clinical outcomes. Spine 30:1565–1575; discussion E1387–E1591PubMedCrossRef
5.
Zurück zum Zitat Cakir B, Richter M, Kafer W, Puhl W, Schmidt R (2005) The impact of total lumbar disc replacement on segmental and total lumbar lordosis. Clin Biomech (Bristol, Avon) 20:357–364CrossRef Cakir B, Richter M, Kafer W, Puhl W, Schmidt R (2005) The impact of total lumbar disc replacement on segmental and total lumbar lordosis. Clin Biomech (Bristol, Avon) 20:357–364CrossRef
6.
Zurück zum Zitat Cakir B, Schmidt R, Huch K, Puhl W, Richter M (2004) [Sagittal alignment and segmental range of motion after total disc replacement of the lumbar spine]. Z Orthop Ihre Grenzgeb 142:159–165PubMedCrossRef Cakir B, Schmidt R, Huch K, Puhl W, Richter M (2004) [Sagittal alignment and segmental range of motion after total disc replacement of the lumbar spine]. Z Orthop Ihre Grenzgeb 142:159–165PubMedCrossRef
7.
Zurück zum Zitat Carragee EJ, Chen Y, Tanner CM, Hayward C, Rossi M, Hagle C (2000) Can discography cause long-term back symptoms in previously asymptomatic subjects? Spine 25:1803–1808PubMedCrossRef Carragee EJ, Chen Y, Tanner CM, Hayward C, Rossi M, Hagle C (2000) Can discography cause long-term back symptoms in previously asymptomatic subjects? Spine 25:1803–1808PubMedCrossRef
8.
Zurück zum Zitat Carragee EJ, Tanner CM, Yang B, Brito JL, Truong T (1999) False-positive findings on lumbar discography. Reliability of subjective concordance assessment during provocative disc injection. Spine 24:2542–2547PubMedCrossRef Carragee EJ, Tanner CM, Yang B, Brito JL, Truong T (1999) False-positive findings on lumbar discography. Reliability of subjective concordance assessment during provocative disc injection. Spine 24:2542–2547PubMedCrossRef
9.
Zurück zum Zitat Carreon LY, Puno RM, Dimar JR 2nd, Glassman SD, Johnson JR (2003) Perioperative complications of posterior lumbar decompression and arthrodesis in older adults. J Bone Joint Surg Am 85-A:2089–2092PubMed Carreon LY, Puno RM, Dimar JR 2nd, Glassman SD, Johnson JR (2003) Perioperative complications of posterior lumbar decompression and arthrodesis in older adults. J Bone Joint Surg Am 85-A:2089–2092PubMed
10.
Zurück zum Zitat Chung SS, Lee CS, Kang CS, Kim SH (2006) The effect of lumbar total disc replacement on the spinopelvic alignment and range of motion of the lumbar spine. J Spinal Disord Tech 19:307–311PubMedCrossRef Chung SS, Lee CS, Kang CS, Kim SH (2006) The effect of lumbar total disc replacement on the spinopelvic alignment and range of motion of the lumbar spine. J Spinal Disord Tech 19:307–311PubMedCrossRef
11.
Zurück zum Zitat Cinotti G, David T, Postacchini F (1996) Results of disc prosthesis after a minimum follow-up period of 2 years. Spine 21:995–1000PubMedCrossRef Cinotti G, David T, Postacchini F (1996) Results of disc prosthesis after a minimum follow-up period of 2 years. Spine 21:995–1000PubMedCrossRef
12.
Zurück zum Zitat Cunningham BW (2004) Basic scientific considerations in total disc arthroplasty. Spine J 4:219S–230SPubMedCrossRef Cunningham BW (2004) Basic scientific considerations in total disc arthroplasty. Spine J 4:219S–230SPubMedCrossRef
13.
Zurück zum Zitat Cunningham BW, Gordon JD, Dmitriev AE, Hu N, McAfee PC (2003) Biomechanical evaluation of total disc replacement arthroplasty: an in vitro human cadaveric model. Spine 28:S110–S117PubMedCrossRef Cunningham BW, Gordon JD, Dmitriev AE, Hu N, McAfee PC (2003) Biomechanical evaluation of total disc replacement arthroplasty: an in vitro human cadaveric model. Spine 28:S110–S117PubMedCrossRef
14.
Zurück zum Zitat David T (1993) Lumbar disc prosthesis: surgical technique, indications and clinical results in 22 patients with a minimum of 12 months follow-up. Eur Spine J 1:254–259CrossRef David T (1993) Lumbar disc prosthesis: surgical technique, indications and clinical results in 22 patients with a minimum of 12 months follow-up. Eur Spine J 1:254–259CrossRef
15.
Zurück zum Zitat Delamarter RB, Fribourg DM, Kanim LE, Bae H (2003) ProDisc artificial total lumbar disc replacement: introduction and early results from the United States clinical trial. Spine 28:S167–175PubMedCrossRef Delamarter RB, Fribourg DM, Kanim LE, Bae H (2003) ProDisc artificial total lumbar disc replacement: introduction and early results from the United States clinical trial. Spine 28:S167–175PubMedCrossRef
16.
Zurück zum Zitat Denoziere G, Ku DN (2006) Biomechanical comparison between fusion of two vertebrae and implantation of an artificial intervertebral disc. J Biomech 39:766–775PubMedCrossRef Denoziere G, Ku DN (2006) Biomechanical comparison between fusion of two vertebrae and implantation of an artificial intervertebral disc. J Biomech 39:766–775PubMedCrossRef
17.
Zurück zum Zitat Dooris AP, Goel VK, Grosland NM, Gilbertson LG, Wilder DG (2001) Load-sharing between anterior and posterior elements in a lumbar motion segment implanted with an artificial disc. Spine 26:E122–E129PubMedCrossRef Dooris AP, Goel VK, Grosland NM, Gilbertson LG, Wilder DG (2001) Load-sharing between anterior and posterior elements in a lumbar motion segment implanted with an artificial disc. Spine 26:E122–E129PubMedCrossRef
18.
Zurück zum Zitat Dreyfuss PH, Dreyer SJ (2003) Lumbar zygapophysial (facet) joint injections. Spine J 3:50S–59SPubMedCrossRef Dreyfuss PH, Dreyer SJ (2003) Lumbar zygapophysial (facet) joint injections. Spine J 3:50S–59SPubMedCrossRef
19.
Zurück zum Zitat Dreyfuss PH, Dreyer SJ, Herring SA (1995) Lumbar zygapophysial (facet) joint injections. Spine 20:2040–2047PubMedCrossRef Dreyfuss PH, Dreyer SJ, Herring SA (1995) Lumbar zygapophysial (facet) joint injections. Spine 20:2040–2047PubMedCrossRef
20.
Zurück zum Zitat Fairbank JC, Couper J, Davies JB, O’Brien JP (1980) The Oswestry low back pain disability questionnaire. Physiotherapy 66:271–273PubMed Fairbank JC, Couper J, Davies JB, O’Brien JP (1980) The Oswestry low back pain disability questionnaire. Physiotherapy 66:271–273PubMed
21.
Zurück zum Zitat Gillet P (2003) The fate of the adjacent motion segments after lumbar fusion. J Spinal Disord Tech 16:338–345PubMed Gillet P (2003) The fate of the adjacent motion segments after lumbar fusion. J Spinal Disord Tech 16:338–345PubMed
22.
Zurück zum Zitat Goel VK, Grauer JN, Patel T, Biyani A, Sairyo K, Vishnubhotla S, Matyas A, Cowgill I, Shaw M, Long R, Dick D, Panjabi MM, Serhan H (2005) Effects of charite artificial disc on the implanted and adjacent spinal segments mechanics using a hybrid testing protocol. Spine 30:2755–2764PubMedCrossRef Goel VK, Grauer JN, Patel T, Biyani A, Sairyo K, Vishnubhotla S, Matyas A, Cowgill I, Shaw M, Long R, Dick D, Panjabi MM, Serhan H (2005) Effects of charite artificial disc on the implanted and adjacent spinal segments mechanics using a hybrid testing protocol. Spine 30:2755–2764PubMedCrossRef
23.
Zurück zum Zitat Goulet JA, Senunas LE, DeSilva GL, Greenfield ML (1997) Autogenous iliac crest bone graft. Complications and functional assessment. Clin Orthop Relat Res 339:76–81PubMedCrossRef Goulet JA, Senunas LE, DeSilva GL, Greenfield ML (1997) Autogenous iliac crest bone graft. Complications and functional assessment. Clin Orthop Relat Res 339:76–81PubMedCrossRef
24.
Zurück zum Zitat Grauer JN, Biyani A, Faizan A, Kiapour A, Sairyo K, Ivanov A, Ebraheim NA, Patel T, Goel VK (2006) Biomechanics of two-level Charite artificial disc placement in comparison to fusion plus single-level disc placement combination. Spine J 6:659–666PubMedCrossRef Grauer JN, Biyani A, Faizan A, Kiapour A, Sairyo K, Ivanov A, Ebraheim NA, Patel T, Goel VK (2006) Biomechanics of two-level Charite artificial disc placement in comparison to fusion plus single-level disc placement combination. Spine J 6:659–666PubMedCrossRef
25.
Zurück zum Zitat Hitchon PW, Eichholz K, Barry C, Rubenbauer P, Ingalhalikar A, Nakamura S, Follett K, Lim TH, Torner J (2005) Biomechanical studies of an artificial disc implant in the human cadaveric spine. J Neurosurg Spine 2:339–343PubMedCrossRef Hitchon PW, Eichholz K, Barry C, Rubenbauer P, Ingalhalikar A, Nakamura S, Follett K, Lim TH, Torner J (2005) Biomechanical studies of an artificial disc implant in the human cadaveric spine. J Neurosurg Spine 2:339–343PubMedCrossRef
26.
Zurück zum Zitat Hochschuler SH, Ohnmeiss DD, Guyer RD, Blumenthal SL (2002) Artificial disc: preliminary results of a prospective study in the United States. Eur Spine J 11(Suppl 2):S106–110PubMed Hochschuler SH, Ohnmeiss DD, Guyer RD, Blumenthal SL (2002) Artificial disc: preliminary results of a prospective study in the United States. Eur Spine J 11(Suppl 2):S106–110PubMed
27.
Zurück zum Zitat Huang RC, Girardi FP, Cammisa FP Jr, Wright TM (2003) The implications of constraint in lumbar total disc replacement. J Spinal Disord Tech 16:412–417PubMedCrossRef Huang RC, Girardi FP, Cammisa FP Jr, Wright TM (2003) The implications of constraint in lumbar total disc replacement. J Spinal Disord Tech 16:412–417PubMedCrossRef
28.
Zurück zum Zitat Huang RC, Girardi FP, Cammisa FP Jr, Tropiano P, Marnay T (2003) Long-term flexion-extension range of motion of the prodisc total disc replacement. J Spinal Disord Tech 16:435–440PubMedCrossRef Huang RC, Girardi FP, Cammisa FP Jr, Tropiano P, Marnay T (2003) Long-term flexion-extension range of motion of the prodisc total disc replacement. J Spinal Disord Tech 16:435–440PubMedCrossRef
29.
Zurück zum Zitat Katz V, Schofferman J, Reynolds J (2003) The sacroiliac joint: a potential cause of pain after lumbar fusion to the sacrum. J Spinal Disord Tech 16:96–99PubMed Katz V, Schofferman J, Reynolds J (2003) The sacroiliac joint: a potential cause of pain after lumbar fusion to the sacrum. J Spinal Disord Tech 16:96–99PubMed
30.
Zurück zum Zitat Kumar MN, Jacquot F, Hall H (2001) Long-term follow-up of functional outcomes and radiographic changes at adjacent levels following lumbar spine fusion for degenerative disc disease. Eur Spine J 10:309–313PubMedCrossRef Kumar MN, Jacquot F, Hall H (2001) Long-term follow-up of functional outcomes and radiographic changes at adjacent levels following lumbar spine fusion for degenerative disc disease. Eur Spine J 10:309–313PubMedCrossRef
31.
Zurück zum Zitat Laslett M, McDonald B, Aprill CN, Tropp H, Oberg B (2006) Clinical predictors of screening lumbar zygapophyseal joint blocks: development of clinical prediction rules. Spine J 6:370–379PubMedCrossRef Laslett M, McDonald B, Aprill CN, Tropp H, Oberg B (2006) Clinical predictors of screening lumbar zygapophyseal joint blocks: development of clinical prediction rules. Spine J 6:370–379PubMedCrossRef
32.
Zurück zum Zitat Lazennec JY, Ramare S, Arafati N, Laudet CG, Gorin M, Roger B, Hansen S, Saillant G, Maurs L, Trabelsi R (2000) Sagittal alignment in lumbosacral fusion: relations between radiological parameters and pain. Eur Spine J 9:47–55PubMedCrossRef Lazennec JY, Ramare S, Arafati N, Laudet CG, Gorin M, Roger B, Hansen S, Saillant G, Maurs L, Trabelsi R (2000) Sagittal alignment in lumbosacral fusion: relations between radiological parameters and pain. Eur Spine J 9:47–55PubMedCrossRef
33.
Zurück zum Zitat Le Huec J, Basso Y, Mathews H, Mehbod A, Aunoble S, Friesem T, Zdeblick T (2005) The effect of single-level, total disc arthroplasty on sagittal balance parameters: a prospective study. Eur Spine J 14:480–486PubMedCrossRef Le Huec J, Basso Y, Mathews H, Mehbod A, Aunoble S, Friesem T, Zdeblick T (2005) The effect of single-level, total disc arthroplasty on sagittal balance parameters: a prospective study. Eur Spine J 14:480–486PubMedCrossRef
34.
Zurück zum Zitat Le Huec JC, Basso Y, Aunoble S, Friesem T, Bruno MB (2005) Influence of facet and posterior muscle degeneration on clinical results of lumbar total disc replacement: two-year follow-up. J Spinal Disord Tech 18:219–223PubMed Le Huec JC, Basso Y, Aunoble S, Friesem T, Bruno MB (2005) Influence of facet and posterior muscle degeneration on clinical results of lumbar total disc replacement: two-year follow-up. J Spinal Disord Tech 18:219–223PubMed
35.
Zurück zum Zitat Lee CK (1988) Accelerated degeneration of the segment adjacent to a lumbar fusion. Spine 13:375–377PubMedCrossRef Lee CK (1988) Accelerated degeneration of the segment adjacent to a lumbar fusion. Spine 13:375–377PubMedCrossRef
36.
Zurück zum Zitat LeHuec JC, Kiaer T, Friesem T, Mathews H, Liu M, Eisermann L (2003) Shock absorption in lumbar disc prosthesis: a preliminary mechanical study. J Spinal Disord Tech 16:346–351PubMed LeHuec JC, Kiaer T, Friesem T, Mathews H, Liu M, Eisermann L (2003) Shock absorption in lumbar disc prosthesis: a preliminary mechanical study. J Spinal Disord Tech 16:346–351PubMed
37.
Zurück zum Zitat Leivseth G, Braaten S, Frobin W, Brinckmann P (2006) Mobility of lumbar segments instrumented with a ProDisc II prosthesis: a two-year follow-up study. Spine 31:1726–1733PubMedCrossRef Leivseth G, Braaten S, Frobin W, Brinckmann P (2006) Mobility of lumbar segments instrumented with a ProDisc II prosthesis: a two-year follow-up study. Spine 31:1726–1733PubMedCrossRef
38.
Zurück zum Zitat Lemaire JP, Carrier H, Ali el HS, Skalli W, Lavaste F (2005) Clinical and radiological outcomes with the Charite artificial disc: a 10-year minimum follow-up. J Spinal Disord Tech 18:353–359PubMedCrossRef Lemaire JP, Carrier H, Ali el HS, Skalli W, Lavaste F (2005) Clinical and radiological outcomes with the Charite artificial disc: a 10-year minimum follow-up. J Spinal Disord Tech 18:353–359PubMedCrossRef
39.
Zurück zum Zitat Lemaire JP, Skalli W, Lavaste F, Templier A, Mendes F, Diop A, Sauty V, Laloux E (1997) Intervertebral disc prosthesis. Results and prospects for the year 2000. Clin Orthop Relat Res 337:64–76PubMedCrossRef Lemaire JP, Skalli W, Lavaste F, Templier A, Mendes F, Diop A, Sauty V, Laloux E (1997) Intervertebral disc prosthesis. Results and prospects for the year 2000. Clin Orthop Relat Res 337:64–76PubMedCrossRef
40.
Zurück zum Zitat Lippitt AB (1984) The facet joint and its role in spine pain. Management with facet joint injections. Spine 9:746–750PubMedCrossRef Lippitt AB (1984) The facet joint and its role in spine pain. Management with facet joint injections. Spine 9:746–750PubMedCrossRef
41.
Zurück zum Zitat Liu J, Ebraheim NA, Haman SP, Shafiq Q, Karkare N, Biyani A, Goel VK, Woldenberg L (2006) Effect of the increase in the height of lumbar disc space on facet joint articulation area in sagittal plane. Spine 31:E198–E202PubMedCrossRef Liu J, Ebraheim NA, Haman SP, Shafiq Q, Karkare N, Biyani A, Goel VK, Woldenberg L (2006) Effect of the increase in the height of lumbar disc space on facet joint articulation area in sagittal plane. Spine 31:E198–E202PubMedCrossRef
42.
Zurück zum Zitat Maigne JY, Planchon CA (2005) Sacroiliac joint pain after lumbar fusion. A study with anesthetic blocks. Eur Spine J 14:654–658PubMedCrossRef Maigne JY, Planchon CA (2005) Sacroiliac joint pain after lumbar fusion. A study with anesthetic blocks. Eur Spine J 14:654–658PubMedCrossRef
43.
Zurück zum Zitat Manchikanti L, Boswell MV (2005) Sacroiliac joint pain after lumbar fusion to the sacrum. J Spinal Disord Tech 18(Suppl):S135PubMedCrossRef Manchikanti L, Boswell MV (2005) Sacroiliac joint pain after lumbar fusion to the sacrum. J Spinal Disord Tech 18(Suppl):S135PubMedCrossRef
44.
Zurück zum Zitat Marks RC, Houston T, Thulbourne T (1992) Facet joint injection and facet nerve block: a randomised comparison in 86 patients with chronic low back pain. Pain 49:325–328PubMedCrossRef Marks RC, Houston T, Thulbourne T (1992) Facet joint injection and facet nerve block: a randomised comparison in 86 patients with chronic low back pain. Pain 49:325–328PubMedCrossRef
45.
Zurück zum Zitat Mayer HM, Wiechert K (2002) Microsurgical anterior approaches to the lumbar spine for interbody fusion and total disc replacement. Neurosurgery 51:S159–S165PubMedCrossRef Mayer HM, Wiechert K (2002) Microsurgical anterior approaches to the lumbar spine for interbody fusion and total disc replacement. Neurosurgery 51:S159–S165PubMedCrossRef
46.
Zurück zum Zitat Mayer HM, Wiechert K, Korge A, Qose I (2002) Minimally invasive total disc replacement: surgical technique and preliminary clinical results. Eur Spine J 11(Suppl 2):S124–S130PubMed Mayer HM, Wiechert K, Korge A, Qose I (2002) Minimally invasive total disc replacement: surgical technique and preliminary clinical results. Eur Spine J 11(Suppl 2):S124–S130PubMed
47.
Zurück zum Zitat McAfee PC, Cunningham BW, Hayes V, Sidiqi F, Dabbah M, Sefter JC, Hu N, Beatson H (2006) Biomechanical analysis of rotational motions after disc arthroplasty: implications for patients with adult deformities. Spine 31:S152–S160PubMedCrossRef McAfee PC, Cunningham BW, Hayes V, Sidiqi F, Dabbah M, Sefter JC, Hu N, Beatson H (2006) Biomechanical analysis of rotational motions after disc arthroplasty: implications for patients with adult deformities. Spine 31:S152–S160PubMedCrossRef
48.
Zurück zum Zitat McAfee PC, Fedder IL, Saiedy S, Shucosky EM, Cunningham BW (2003) SB Charite disc replacement: report of 60 prospective randomized cases in a US center. J Spinal Disord Tech 16:424–433PubMed McAfee PC, Fedder IL, Saiedy S, Shucosky EM, Cunningham BW (2003) SB Charite disc replacement: report of 60 prospective randomized cases in a US center. J Spinal Disord Tech 16:424–433PubMed
49.
Zurück zum Zitat Moshirfar A, Jenis LG, Spector LR, Burke PJ, Losina E, Katz JN, Rand FF, Tromanhauser SG, Banco RJ (2006) Computed tomography evaluation of superior-segment facet-joint violation after pedicle instrumentation of the lumbar spine with a midline surgical approach. Spine 31:2624–2629PubMedCrossRef Moshirfar A, Jenis LG, Spector LR, Burke PJ, Losina E, Katz JN, Rand FF, Tromanhauser SG, Banco RJ (2006) Computed tomography evaluation of superior-segment facet-joint violation after pedicle instrumentation of the lumbar spine with a midline surgical approach. Spine 31:2624–2629PubMedCrossRef
50.
Zurück zum Zitat O’Leary P, Nicolakis M, Lorenz MA, Voronov LI, Zindrick MR, Ghanayem A, Havey RM, Carandang G, Sartori M, Gaitanis IN, Fronczak S, Patwardhan AG (2005) Response of Charite total disc replacement under physiologic loads: prosthesis component motion patterns. Spine J 5:590–599PubMedCrossRef O’Leary P, Nicolakis M, Lorenz MA, Voronov LI, Zindrick MR, Ghanayem A, Havey RM, Carandang G, Sartori M, Gaitanis IN, Fronczak S, Patwardhan AG (2005) Response of Charite total disc replacement under physiologic loads: prosthesis component motion patterns. Spine J 5:590–599PubMedCrossRef
51.
Zurück zum Zitat Polly DW Jr (2003) Adapting innovative motion-preserving technology to spinal surgical practice: what should we expect to happen? Spine 28:S104–S109PubMedCrossRef Polly DW Jr (2003) Adapting innovative motion-preserving technology to spinal surgical practice: what should we expect to happen? Spine 28:S104–S109PubMedCrossRef
52.
Zurück zum Zitat Putzier M, Funk JF, Schneider SV, Gross C, Tohtz SW, Khodadadyan-Klostermann C, Perka C, Kandziora F (2006) Charite total disc replacement-clinical and radiographical results after an average follow-up of 17 years. Eur Spine J 15:183–195PubMedCrossRef Putzier M, Funk JF, Schneider SV, Gross C, Tohtz SW, Khodadadyan-Klostermann C, Perka C, Kandziora F (2006) Charite total disc replacement-clinical and radiographical results after an average follow-up of 17 years. Eur Spine J 15:183–195PubMedCrossRef
53.
Zurück zum Zitat Rohlmann A, Zander T, Bergmann G (2005) Effect of total disc replacement with ProDisc on intersegmental rotation of the lumbar spine. Spine 30:738–743PubMedCrossRef Rohlmann A, Zander T, Bergmann G (2005) Effect of total disc replacement with ProDisc on intersegmental rotation of the lumbar spine. Spine 30:738–743PubMedCrossRef
54.
Zurück zum Zitat Rousseau MA, Bradford DS, Bertagnoli R, Hu SS, Lotz JC (2006) Disc arthroplasty design influences intervertebral kinematics and facet forces. Spine J 6:258–266PubMedCrossRef Rousseau MA, Bradford DS, Bertagnoli R, Hu SS, Lotz JC (2006) Disc arthroplasty design influences intervertebral kinematics and facet forces. Spine J 6:258–266PubMedCrossRef
55.
Zurück zum Zitat Sariali el H, Lemaire JP, Pascal-Mousselard H, Carrier H, Skalli W (2006) In vivo study of the kinematics in axial rotation of the lumbar spine after total intervertebral disc replacement: long-term results: a 10–14 years follow up evaluation. Eur Spine J 15:1501–1510CrossRef Sariali el H, Lemaire JP, Pascal-Mousselard H, Carrier H, Skalli W (2006) In vivo study of the kinematics in axial rotation of the lumbar spine after total intervertebral disc replacement: long-term results: a 10–14 years follow up evaluation. Eur Spine J 15:1501–1510CrossRef
56.
Zurück zum Zitat Shim CS, Lee SH, Shin HD, Kang HS, Choi WC, Jung B, Choi G, Ahn Y, Lee S, Lee HY (2007) CHARITE versus ProDisc: a comparative study of a minimum 3-year follow-up. Spine 32:1012–1018PubMedCrossRef Shim CS, Lee SH, Shin HD, Kang HS, Choi WC, Jung B, Choi G, Ahn Y, Lee S, Lee HY (2007) CHARITE versus ProDisc: a comparative study of a minimum 3-year follow-up. Spine 32:1012–1018PubMedCrossRef
57.
Zurück zum Zitat Siepe CJ, Mayer HM, Heinz-Leisenheimer M, Korge A (2007) Total lumbar disc replacement: different results for different levels. Spine 32:782–790PubMedCrossRef Siepe CJ, Mayer HM, Heinz-Leisenheimer M, Korge A (2007) Total lumbar disc replacement: different results for different levels. Spine 32:782–790PubMedCrossRef
58.
Zurück zum Zitat Siepe CJ, Mayer HM, Wiechert K, Korge A (2006) Clinical results of total lumbar disc replacement with ProDisc II: three-year results for different indications. Spine 31:1923–1932PubMedCrossRef Siepe CJ, Mayer HM, Wiechert K, Korge A (2006) Clinical results of total lumbar disc replacement with ProDisc II: three-year results for different indications. Spine 31:1923–1932PubMedCrossRef
59.
Zurück zum Zitat Siepe CJ, Wiechert K, Khattab MF, Korge A, Mayer HM (2007) Total lumbar disc replacement in athletes: clinical results, return to sport and athletic performance. Eur Spine J 16:1001–1013PubMedCrossRef Siepe CJ, Wiechert K, Khattab MF, Korge A, Mayer HM (2007) Total lumbar disc replacement in athletes: clinical results, return to sport and athletic performance. Eur Spine J 16:1001–1013PubMedCrossRef
60.
Zurück zum Zitat Singh K, Vaccaro AR, Albert TJ (2004) Assessing the potential impact of total disc arthroplasty on surgeon practice patterns in North America. Spine J 4:195S–201SPubMedCrossRef Singh K, Vaccaro AR, Albert TJ (2004) Assessing the potential impact of total disc arthroplasty on surgeon practice patterns in North America. Spine J 4:195S–201SPubMedCrossRef
61.
Zurück zum Zitat Tournier C, Aunoble S, Le Huec JC, Lemaire JP, Tropiano P, Lafage V, Skalli W (2007) Total disc arthroplasty: consequences for sagittal balance and lumbar spine movement. Eur Spine J 16:411–421PubMedCrossRef Tournier C, Aunoble S, Le Huec JC, Lemaire JP, Tropiano P, Lafage V, Skalli W (2007) Total disc arthroplasty: consequences for sagittal balance and lumbar spine movement. Eur Spine J 16:411–421PubMedCrossRef
62.
Zurück zum Zitat Trouillier H, Kern P, Refior HJ, Muller-Gerbl M (2006) A prospective morphological study of facet joint integrity following intervertebral disc replacement with the CHARITE(trade mark) Artificial Disc. Eur Spine J 15:174–182PubMedCrossRef Trouillier H, Kern P, Refior HJ, Muller-Gerbl M (2006) A prospective morphological study of facet joint integrity following intervertebral disc replacement with the CHARITE(trade mark) Artificial Disc. Eur Spine J 15:174–182PubMedCrossRef
63.
Zurück zum Zitat Umehara S, Zindrick MR, Patwardhan AG, Havey RM, Vrbos LA, Knight GW, Miyano S, Kirincic M, Kaneda K, Lorenz MA (2000) The biomechanical effect of postoperative hypolordosis in instrumented lumbar fusion on instrumented and adjacent spinal segments. Spine 25:1617–1624PubMedCrossRef Umehara S, Zindrick MR, Patwardhan AG, Havey RM, Vrbos LA, Knight GW, Miyano S, Kirincic M, Kaneda K, Lorenz MA (2000) The biomechanical effect of postoperative hypolordosis in instrumented lumbar fusion on instrumented and adjacent spinal segments. Spine 25:1617–1624PubMedCrossRef
64.
Zurück zum Zitat van Ooij A, Oner FC, Verbout AJ (2003) Complications of artificial disc replacement: a report of 27 patients with the SB Charite disc. J Spinal Disord Tech 16:369–383PubMed van Ooij A, Oner FC, Verbout AJ (2003) Complications of artificial disc replacement: a report of 27 patients with the SB Charite disc. J Spinal Disord Tech 16:369–383PubMed
65.
Zurück zum Zitat van Tulder MW, Koes B, Seitsalo S, Malmivaara A (2006) Outcome of invasive treatment modalities on back pain and sciatica: an evidence-based review. Eur Spine J 15(Suppl 1):S82–92PubMedCrossRef van Tulder MW, Koes B, Seitsalo S, Malmivaara A (2006) Outcome of invasive treatment modalities on back pain and sciatica: an evidence-based review. Eur Spine J 15(Suppl 1):S82–92PubMedCrossRef
66.
Zurück zum Zitat Zeegers WS, Bohnen LM, Laaper M, Verhaegen MJ (1999) Artificial disc replacement with the modular type SB Charite III: 2-year results in 50 prospectively studied patients. Eur Spine J 8:210–217PubMedCrossRef Zeegers WS, Bohnen LM, Laaper M, Verhaegen MJ (1999) Artificial disc replacement with the modular type SB Charite III: 2-year results in 50 prospectively studied patients. Eur Spine J 8:210–217PubMedCrossRef
67.
Zurück zum Zitat Zigler J, Delamarter R, Spivak JM, Linovitz RJ, Danielson GO 3rd, Haider TT, Cammisa F, Zuchermann J, Balderston R, Kitchel S, Foley K, Watkins R, Bradford D, Yue J, Yuan H, Herkowitz H, Geiger D, Bendo J, Peppers T, Sachs B, Girardi F, Kropf M, Goldstein J (2007) Results of the prospective, randomized, multicenter food and drug administration investigational device exemption study of the ProDisc-L total disc replacement versus circumferential fusion for the treatment of 1-level degenerative disc disease. Spine 32:1155–1162; discussion 1163PubMedCrossRef Zigler J, Delamarter R, Spivak JM, Linovitz RJ, Danielson GO 3rd, Haider TT, Cammisa F, Zuchermann J, Balderston R, Kitchel S, Foley K, Watkins R, Bradford D, Yue J, Yuan H, Herkowitz H, Geiger D, Bendo J, Peppers T, Sachs B, Girardi F, Kropf M, Goldstein J (2007) Results of the prospective, randomized, multicenter food and drug administration investigational device exemption study of the ProDisc-L total disc replacement versus circumferential fusion for the treatment of 1-level degenerative disc disease. Spine 32:1155–1162; discussion 1163PubMedCrossRef
68.
Zurück zum Zitat Zigler JE (2003) Clinical results with ProDisc: European experience and U.S. investigation device exemption study. Spine 28:S163–S166PubMedCrossRef Zigler JE (2003) Clinical results with ProDisc: European experience and U.S. investigation device exemption study. Spine 28:S163–S166PubMedCrossRef
69.
Zurück zum Zitat Zigler JE, Burd TA, Vialle EN, Sachs BL, Rashbaum RF, Ohnmeiss DD (2003) Lumbar spine arthroplasty: early results using the ProDisc II: a prospective randomized trial of arthroplasty versus fusion. J Spinal Disord Tech 16:352–361PubMed Zigler JE, Burd TA, Vialle EN, Sachs BL, Rashbaum RF, Ohnmeiss DD (2003) Lumbar spine arthroplasty: early results using the ProDisc II: a prospective randomized trial of arthroplasty versus fusion. J Spinal Disord Tech 16:352–361PubMed
Metadaten
Titel
Analysis of post-operative pain patterns following total lumbar disc replacement: results from fluoroscopically guided spine infiltrations
verfasst von
Christoph J. Siepe
Andreas Korge
Frank Grochulla
Christoph Mehren
H. Michael Mayer
Publikationsdatum
01.01.2008
Verlag
Springer-Verlag
Erschienen in
European Spine Journal / Ausgabe 1/2008
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-007-0519-3

Weitere Artikel der Ausgabe 1/2008

European Spine Journal 1/2008 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.