01.05.2008 | Ideas and Technical Innocations

Trunk posture monitoring with inertial sensors

verfasst von: Wai Yin Wong, Man Sang Wong

Erschienen in: European Spine Journal | Ausgabe 5/2008

Einloggen, um Zugang zu erhalten

Abstract

Measurement of human posture and movement is an important area of research in the bioengineering and rehabilitation fields. Various attempts have been initiated for different clinical application goals, such as diagnosis of pathological posture and movements, assessment of pre- and post-treatment efficacy and comparison of different treatment protocols. Image-based methods for measurements of human posture and movements have been developed, such as the radiography, photogrammetry, optoelectric technique and video analysis. However, it is found that these methods are complicated to set up, time-consuming to operate and could only be applied in laboratory environments. This study introduced a method of using a posture monitoring system in estimating the spinal curvature changes during trunk movements on the sagittal and coronal planes and providing trunk posture monitoring during daily activities. The system consisted of three sensor modules, each with one tri-axial accelerometer and three uni-axial gyroscopes orthogonally aligned, and a digital data acquisition and feedback system. The accuracy of this system was tested with a motion analysis system (Vicon 370) in calibration with experimental setup and in trunk posture measurement with nine human subjects, and the performance of the posture monitoring system during daily activities with two human subjects was reported. The averaged root mean squared differences between the measurements of the system and motion analysis system were found to be <1.5° in dynamic calibration, and <3.1° for the sagittal plane and ≤2.1° for the coronal plane in estimation of the trunk posture change during trunk movements. The measurements of the system and the motion analysis system was highly correlated (>0.999 for dynamic calibration and >0.829 for estimation of spinal curvature change in domain planes of movement during flexion and lateral bending). With the sensing modules located on the upper trunk, mid-trunk and the pelvic levels, the inclination of trunk segment and the change of spinal curvature in trunk movements could be estimated. The posture information of five subjects was recorded at 30 s intervals during daily activity over a period of 3 days and 2 h a day. The preliminary results demonstrated that the subjects could improve their posture when feedback signals were provided. The posture monitoring system could be used for the purpose of posture monitoring during daily activity.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Bazzarelli M, Durdle NG, Lou E, Raso J (2001) A low power hybrid posture monitoring system. Elect Comput Eng 2:13–16 Bazzarelli M, Durdle NG, Lou E, Raso J (2001) A low power hybrid posture monitoring system. Elect Comput Eng 2:13–16
2.
Zurück zum Zitat Bull AMJ, McGregor AH (2000) Measuring spinal motion in rowers: the use of an electromagnetic device. Clin Biomech 15:772–776CrossRef Bull AMJ, McGregor AH (2000) Measuring spinal motion in rowers: the use of an electromagnetic device. Clin Biomech 15:772–776CrossRef
3.
Zurück zum Zitat Chockalingam N, Dangerfield P (2003) Non-invasive measurements of scoliosis and the spine: a review of the literature. Int J Therapy Rehabil 10(12):554–562 Chockalingam N, Dangerfield P (2003) Non-invasive measurements of scoliosis and the spine: a review of the literature. Int J Therapy Rehabil 10(12):554–562
4.
Zurück zum Zitat Dworkin B, Miller NE, Dworkin N (1985) Behavioral method for the treatment of idiopathic scoliosis. Proc Nat Acad Sci 82:2493–2497PubMedCrossRef Dworkin B, Miller NE, Dworkin N (1985) Behavioral method for the treatment of idiopathic scoliosis. Proc Nat Acad Sci 82:2493–2497PubMedCrossRef
5.
Zurück zum Zitat Eddy DS, Sparks DR (1998) Application of MEMS technology in automative sensors and actuator. Proc IEEE 86(8):1747–1755CrossRef Eddy DS, Sparks DR (1998) Application of MEMS technology in automative sensors and actuator. Proc IEEE 86(8):1747–1755CrossRef
6.
Zurück zum Zitat Gracovetsky S, Newman N, Pawlowsky M, Lanzo V, Davey B, Robinson L (1995) A database for estimating normal spinal motion derived from noninvasive measurements. Spine 20(9):1036–1046PubMedCrossRef Gracovetsky S, Newman N, Pawlowsky M, Lanzo V, Davey B, Robinson L (1995) A database for estimating normal spinal motion derived from noninvasive measurements. Spine 20(9):1036–1046PubMedCrossRef
7.
Zurück zum Zitat Lee RYM (2001) Kinematics of rotational mobilization of the lumbar spine. Clin Biomech 16:481–488CrossRef Lee RYM (2001) Kinematics of rotational mobilization of the lumbar spine. Clin Biomech 16:481–488CrossRef
8.
Zurück zum Zitat Lee RYW, Laprade J, Fung EHK (2003) A real-time gyroscopic system for three-dimensional measurement of lumbar spine motion. Med Eng Phys 25:817–824PubMedCrossRef Lee RYW, Laprade J, Fung EHK (2003) A real-time gyroscopic system for three-dimensional measurement of lumbar spine motion. Med Eng Phys 25:817–824PubMedCrossRef
9.
Zurück zum Zitat Lobel WY (1967) Measurement of spinal posture and range of spinal movement. Ann Phys Med 9(3):103–110 Lobel WY (1967) Measurement of spinal posture and range of spinal movement. Ann Phys Med 9(3):103–110
10.
Zurück zum Zitat Lou E, Bazzarelli M, Hill D, Durdle N (2001) A low power accelerometer used to improve posture. In: Proceedings of the IEEE Canadian conference on electrical & computer engineering, pp 1385–1389 Lou E, Bazzarelli M, Hill D, Durdle N (2001) A low power accelerometer used to improve posture. In: Proceedings of the IEEE Canadian conference on electrical & computer engineering, pp 1385–1389
11.
Zurück zum Zitat Lou E, Raso J, Hill D, Durdle N, Moreau M (2002) Spine-straight device for the treatment of kyphosis. Stud Health Technol Inf Res Spinal Deformities 4:401–404 Lou E, Raso J, Hill D, Durdle N, Moreau M (2002) Spine-straight device for the treatment of kyphosis. Stud Health Technol Inf Res Spinal Deformities 4:401–404
12.
Zurück zum Zitat Mannion A, Troke M (1999) A comparison of two motion analysis devices used in the measurement of lumbar spinal mobility. Clin Biomech 14:612–619CrossRef Mannion A, Troke M (1999) A comparison of two motion analysis devices used in the measurement of lumbar spinal mobility. Clin Biomech 14:612–619CrossRef
13.
Zurück zum Zitat McGregor AH, McCarthy ID, Hughes SP (1995) Motion characteristics of the lumbar spine in the normal population. Spine 20(22):2421–2428PubMedCrossRef McGregor AH, McCarthy ID, Hughes SP (1995) Motion characteristics of the lumbar spine in the normal population. Spine 20(22):2421–2428PubMedCrossRef
14.
Zurück zum Zitat Nevins RJ, Durdle NG, Raso VJ (2002) A posture monitoring system using accelerometers. In: Proceedings of the IEEE Canadian conference on electrical & computer engineering, pp 1087–1092 Nevins RJ, Durdle NG, Raso VJ (2002) A posture monitoring system using accelerometers. In: Proceedings of the IEEE Canadian conference on electrical & computer engineering, pp 1087–1092
15.
Zurück zum Zitat Pearcy M (1986) Measurement of back and spinal mobility. Clin Biomech 1:44–51CrossRef Pearcy M (1986) Measurement of back and spinal mobility. Clin Biomech 1:44–51CrossRef
16.
Zurück zum Zitat Pearcy MJ, Gill JM, Whittle MW, Johnson GR (1987) Dynamic back movement measured using a three-dimensional television system. J Biomech 20(10):943–949PubMedCrossRef Pearcy MJ, Gill JM, Whittle MW, Johnson GR (1987) Dynamic back movement measured using a three-dimensional television system. J Biomech 20(10):943–949PubMedCrossRef
17.
Zurück zum Zitat Ployon A, Lavaste F, Maurel N, Skalli W, Roland-Gosselin A, Dubousset J, Zeller R (1997) In-vivo experimental research into the pre- and post-operative behavior of the scoliosis spine. Hum Mov Sci 16:299–230CrossRef Ployon A, Lavaste F, Maurel N, Skalli W, Roland-Gosselin A, Dubousset J, Zeller R (1997) In-vivo experimental research into the pre- and post-operative behavior of the scoliosis spine. Hum Mov Sci 16:299–230CrossRef
18.
Zurück zum Zitat Roetenberg D, Luinge HJ, Baten CTM, Veltink PH (2005) Compensation of magnetic disturbances improves inertial and magnetic sensing of human body segment orientation. IEEE Trans Neural Syst Rehabil Eng 13(3):395–405PubMedCrossRef Roetenberg D, Luinge HJ, Baten CTM, Veltink PH (2005) Compensation of magnetic disturbances improves inertial and magnetic sensing of human body segment orientation. IEEE Trans Neural Syst Rehabil Eng 13(3):395–405PubMedCrossRef
Metadaten
Titel
Trunk posture monitoring with inertial sensors
verfasst von
Wai Yin Wong
Man Sang Wong
Publikationsdatum
01.05.2008
Verlag
Springer-Verlag
Erschienen in
European Spine Journal / Ausgabe 5/2008
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-008-0586-0

Weitere Artikel der Ausgabe 5/2008

European Spine Journal 5/2008 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.