Skip to main content
Erschienen in: European Spine Journal 5/2015

01.05.2015 | Original Article

Clinical evaluation of the polymethylmethacrylate-augmented thoracic and lumbar pedicle screw fixation guided by the three-dimensional navigation for the osteoporosis patients

verfasst von: Qiang Yuan, Guilin Zhang, Jingye Wu, Yonggang Xing, Yuqing Sun, Wei Tian

Erschienen in: European Spine Journal | Ausgabe 5/2015

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To evaluate the safety and efficacy of three-dimensional (3D) navigation-guided polymethylmethacrylate (PMMA)-augmented thoracic and lumbar pedicle screw fixation for the osteoporotic patients.

Methods

27 consecutive osteoporosis patients with a variety of spinal disorders who underwent 3D navigation-guided PMMA-augmented pedicle screw fixation were evaluated clinically and radiologically in the perioperative and 1-year follow-up period. The improvement of Japanese Orthopaedic Association (JOA) scores was analyzed. PMMA leakage and other complications were inspected intraoperatively and postoperatively. Screw loosening and bone fusion were evaluated radiographically during follow-up.

Results

8 patients had thoracic and lumbar fractures; 18 patients had degenerative spinal disorders; one patient had revision surgery. One patient died of postoperative pneumonia. Each of the other 26 patients was followed up regularly at 3, 6, 12 and 18 months postoperatively. The mean therapeutic improvement rate is 39.6 % evaluated by JOA scores. 2 patients (7.4 %) had leakage into the spinal canal in front of the posterior longitudinal ligament and two patients (7.4 %) had leakage into the prevertebral soft tissue inspected by the postoperative CT scans. No pedicle cortex breach and cement leakage surrounding pedicle cortex were observed. None of patients complained of dyspnoea and showed evidence of pulmonary embolism. Bone fusions were found in 20 patients (bony fusion rate 76.9 %) at the 12-month follow-up and no screw loosening occurs.

Conclusion

The results show favorable outcome using 3D navigation-guided PMMA-augmented thoracic and lumbar pedicle screw fixation for the osteoporosis patients both clinically and radiologically.
Literatur
1.
Zurück zum Zitat Cummings SR, Melton LJ (2002) Epidemiology and outcomes of osteoporotic fractures. Lancet 359(9319):1761–1767CrossRefPubMed Cummings SR, Melton LJ (2002) Epidemiology and outcomes of osteoporotic fractures. Lancet 359(9319):1761–1767CrossRefPubMed
2.
Zurück zum Zitat Paxinos O, Tsitsopoulos PP, Zindrick MR, Voronov LI et al (2010) Evaluation of pullout strength and failure mechanism of posterior instrumentation in normal and osteopenic thoracic vertebrae. J Neurosurg Spine 13(4):469–476CrossRefPubMed Paxinos O, Tsitsopoulos PP, Zindrick MR, Voronov LI et al (2010) Evaluation of pullout strength and failure mechanism of posterior instrumentation in normal and osteopenic thoracic vertebrae. J Neurosurg Spine 13(4):469–476CrossRefPubMed
3.
Zurück zum Zitat Halvorson TL, Kelley LA, Thomas KA, Whitecloud TS 3rd, Cook SD (1994) Effects of bone mineral density on pedicle screw fixation. Spine (Phila Pa 1976) 19(21):2415–2420CrossRef Halvorson TL, Kelley LA, Thomas KA, Whitecloud TS 3rd, Cook SD (1994) Effects of bone mineral density on pedicle screw fixation. Spine (Phila Pa 1976) 19(21):2415–2420CrossRef
4.
Zurück zum Zitat Garfin SR, Yuan HA, Reiley MA (2001) New technologies in spine: kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures. Spine (Phila Pa 1976) 26(14):1511–1515CrossRef Garfin SR, Yuan HA, Reiley MA (2001) New technologies in spine: kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures. Spine (Phila Pa 1976) 26(14):1511–1515CrossRef
5.
Zurück zum Zitat Frankel BM, Jones T, Wang C (2007) Segmental polymethylmethacrylate-augmented pedicle screw fixation in patients with bone softening caused by osteoporosis and metastatic tumor involvement: a clinical evaluation. Neurosurgery 61(3):531–537 (discussion 537–538)CrossRefPubMed Frankel BM, Jones T, Wang C (2007) Segmental polymethylmethacrylate-augmented pedicle screw fixation in patients with bone softening caused by osteoporosis and metastatic tumor involvement: a clinical evaluation. Neurosurgery 61(3):531–537 (discussion 537–538)CrossRefPubMed
6.
Zurück zum Zitat Fuentes S, Blondel B, Metellus P, Gaudart J, Adetchessi T, Dufour H (2010) Percutaneous kyphoplasty and pedicle screw fixation for the management of thoraco-lumbar burst fractures. Eur Spine J 19(8):1281–1287CrossRefPubMedCentralPubMed Fuentes S, Blondel B, Metellus P, Gaudart J, Adetchessi T, Dufour H (2010) Percutaneous kyphoplasty and pedicle screw fixation for the management of thoraco-lumbar burst fractures. Eur Spine J 19(8):1281–1287CrossRefPubMedCentralPubMed
7.
Zurück zum Zitat Becker S, Chavanne A, Spitaler R, Kropik K et al (2008) Assessment of different screw augmentation techniques and screw designs in osteoporotic spines. Eur Spine J 17(11):1462–1469CrossRefPubMedCentralPubMed Becker S, Chavanne A, Spitaler R, Kropik K et al (2008) Assessment of different screw augmentation techniques and screw designs in osteoporotic spines. Eur Spine J 17(11):1462–1469CrossRefPubMedCentralPubMed
8.
Zurück zum Zitat Gao M, Lei W, Wu Z, Liu D, Shi L (2011) Biomechanical evaluation of fixation strength of conventional and expansive pedicle screws with or without calcium based cement augmentation. Clin Biomech (Bristol, Avon) 26(3):238–244CrossRef Gao M, Lei W, Wu Z, Liu D, Shi L (2011) Biomechanical evaluation of fixation strength of conventional and expansive pedicle screws with or without calcium based cement augmentation. Clin Biomech (Bristol, Avon) 26(3):238–244CrossRef
9.
Zurück zum Zitat Waits C, Burton D, McIff T (2009) Cement augmentation of pedicle screw fixation using novel cannulated cement insertion device. Spine (Phila Pa 1976) 34(14):E478–E483CrossRef Waits C, Burton D, McIff T (2009) Cement augmentation of pedicle screw fixation using novel cannulated cement insertion device. Spine (Phila Pa 1976) 34(14):E478–E483CrossRef
10.
Zurück zum Zitat Ren H, Shen Y, Zhang YZ, Ding WY et al (2010) Correlative factor analysis on the complications resulting from cement leakage after percutaneous kyphoplasty in the treatment of osteoporotic vertebral compression fracture. J Spinal Disord Tech 23(7):e9–e15CrossRefPubMed Ren H, Shen Y, Zhang YZ, Ding WY et al (2010) Correlative factor analysis on the complications resulting from cement leakage after percutaneous kyphoplasty in the treatment of osteoporotic vertebral compression fracture. J Spinal Disord Tech 23(7):e9–e15CrossRefPubMed
11.
Zurück zum Zitat Wilkes RA, Mackinnon JG, Thomas WG (1994) Neurological deterioration after cement injection into a vertebral body. J Bone Joint Surg Br 76(1):155PubMed Wilkes RA, Mackinnon JG, Thomas WG (1994) Neurological deterioration after cement injection into a vertebral body. J Bone Joint Surg Br 76(1):155PubMed
12.
Zurück zum Zitat Rajan VV, Kamath V, Shetty AP, Rajasekaran S (2010) Iso-C3D navigation assisted pedicle screw placement in deformities of the cervical and thoracic spine. Indian J Orthop 44 (2):163–168 Rajan VV, Kamath V, Shetty AP, Rajasekaran S (2010) Iso-C3D navigation assisted pedicle screw placement in deformities of the cervical and thoracic spine. Indian J Orthop 44 (2):163–168
13.
Zurück zum Zitat Kosmopoulos V, Schizas C (2007) Pedicle screw placement accuracy: a meta-analysis. Spine (Phila Pa 1976) 32(3):E111–E120CrossRef Kosmopoulos V, Schizas C (2007) Pedicle screw placement accuracy: a meta-analysis. Spine (Phila Pa 1976) 32(3):E111–E120CrossRef
14.
Zurück zum Zitat Engelke K, Adams JE, Armbrecht G, Augat P et al (2008) Clinical use of quantitative computed tomography and peripheral quantitative computed tomography in the management of osteoporosis in adults: the 2007 ISCD official positions. J Clin Densitom 11(1):123–162CrossRefPubMed Engelke K, Adams JE, Armbrecht G, Augat P et al (2008) Clinical use of quantitative computed tomography and peripheral quantitative computed tomography in the management of osteoporosis in adults: the 2007 ISCD official positions. J Clin Densitom 11(1):123–162CrossRefPubMed
15.
Zurück zum Zitat Sawakami K, Yamazaki A, Ishikawa S, Ito T, Watanabe K, Endo N (2012) Polymethylmethacrylate augmentation of pedicle screws increases the initial fixation in osteoporotic spine patients. J Spinal Disord Tech 25(2):E28–E35CrossRefPubMed Sawakami K, Yamazaki A, Ishikawa S, Ito T, Watanabe K, Endo N (2012) Polymethylmethacrylate augmentation of pedicle screws increases the initial fixation in osteoporotic spine patients. J Spinal Disord Tech 25(2):E28–E35CrossRefPubMed
16.
Zurück zum Zitat Gaines RW Jr (2000) The use of pedicle-screw internal fixation for the operative treatment of spinal disorders. J Bone Joint Surg Am 82-A(10):1458–1476PubMed Gaines RW Jr (2000) The use of pedicle-screw internal fixation for the operative treatment of spinal disorders. J Bone Joint Surg Am 82-A(10):1458–1476PubMed
17.
Zurück zum Zitat Lane NE (2006) Epidemiology, etiology, and diagnosis of osteoporosis. Am J Obstet Gynecol 194(2 Suppl):S3–S11CrossRefPubMed Lane NE (2006) Epidemiology, etiology, and diagnosis of osteoporosis. Am J Obstet Gynecol 194(2 Suppl):S3–S11CrossRefPubMed
18.
Zurück zum Zitat Sarzier JS, Evans AJ, Cahill DW (2002) Increased pedicle screw pullout strength with vertebroplasty augmentation in osteoporotic spines. J Neurosurg 96(3 Suppl):309–312PubMed Sarzier JS, Evans AJ, Cahill DW (2002) Increased pedicle screw pullout strength with vertebroplasty augmentation in osteoporotic spines. J Neurosurg 96(3 Suppl):309–312PubMed
19.
Zurück zum Zitat Wittenberg RH, Lee KS, Shea M, White AA 3rd, Hayes WC (1993) Effect of screw diameter, insertion technique, and bone cement augmentation of pedicular screw fixation strength. Clin Orthop Relat Res 296:278–287PubMed Wittenberg RH, Lee KS, Shea M, White AA 3rd, Hayes WC (1993) Effect of screw diameter, insertion technique, and bone cement augmentation of pedicular screw fixation strength. Clin Orthop Relat Res 296:278–287PubMed
20.
Zurück zum Zitat Frankel BM, Jones T, Wang C (2007) Segmental polymethylmethacrylate-augmented pedicle screw fixation in patients with bone softening caused by osteoporosis and metastatic tumor involvement: a clinical evaluation. Neurosurgery 61(3):531–537 (discussion 537–538)CrossRefPubMed Frankel BM, Jones T, Wang C (2007) Segmental polymethylmethacrylate-augmented pedicle screw fixation in patients with bone softening caused by osteoporosis and metastatic tumor involvement: a clinical evaluation. Neurosurgery 61(3):531–537 (discussion 537–538)CrossRefPubMed
21.
Zurück zum Zitat Chang MC, Liu CL, Chen TH (2008) Polymethylmethacrylate augmentation of pedicle screw for osteoporotic spinal surgery: a novel technique. Spine (Phila Pa 1976) 33(10):E317–E324CrossRef Chang MC, Liu CL, Chen TH (2008) Polymethylmethacrylate augmentation of pedicle screw for osteoporotic spinal surgery: a novel technique. Spine (Phila Pa 1976) 33(10):E317–E324CrossRef
22.
Zurück zum Zitat Rajasekaran S, Vidyadhara S, Ramesh P, Shetty AP (2007) Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries. Spine (Phila Pa 1976) 32(2):E56–E64CrossRef Rajasekaran S, Vidyadhara S, Ramesh P, Shetty AP (2007) Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries. Spine (Phila Pa 1976) 32(2):E56–E64CrossRef
23.
Zurück zum Zitat Hulme PA, Krebs J, Ferguson SJ, Berlemann U (2006) Vertebroplasty and kyphoplasty: a systematic review of 69 clinical studies. Spine (Phila Pa 1976) 31(17):1983–2001CrossRef Hulme PA, Krebs J, Ferguson SJ, Berlemann U (2006) Vertebroplasty and kyphoplasty: a systematic review of 69 clinical studies. Spine (Phila Pa 1976) 31(17):1983–2001CrossRef
24.
Zurück zum Zitat Merloz P, Troccaz J, Vouaillat H, Vasile C et al (2007) Fluoroscopy-based navigation system in spine surgery. Proc Inst Mech Eng H 221(7):813–820CrossRefPubMed Merloz P, Troccaz J, Vouaillat H, Vasile C et al (2007) Fluoroscopy-based navigation system in spine surgery. Proc Inst Mech Eng H 221(7):813–820CrossRefPubMed
25.
Zurück zum Zitat Chen LH, Tai CL, Lee DM, Lai PL et al (2011) Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: a comparative study between cannulated screws with cement injection and solid screws with cement pre-filling. BMC Musculoskelet Disord 12:33CrossRefPubMedCentralPubMed Chen LH, Tai CL, Lee DM, Lai PL et al (2011) Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: a comparative study between cannulated screws with cement injection and solid screws with cement pre-filling. BMC Musculoskelet Disord 12:33CrossRefPubMedCentralPubMed
Metadaten
Titel
Clinical evaluation of the polymethylmethacrylate-augmented thoracic and lumbar pedicle screw fixation guided by the three-dimensional navigation for the osteoporosis patients
verfasst von
Qiang Yuan
Guilin Zhang
Jingye Wu
Yonggang Xing
Yuqing Sun
Wei Tian
Publikationsdatum
01.05.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
European Spine Journal / Ausgabe 5/2015
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-013-3131-8

Weitere Artikel der Ausgabe 5/2015

European Spine Journal 5/2015 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.