Skip to main content
Erschienen in: European Spine Journal 6/2016

22.09.2015 | Original Article

A new 3-dimensional method for measuring precision in surgical navigation and methods to optimize navigation accuracy

verfasst von: Christopher J. Kleck, Ian Cullilmore, Matthew LaFleur, Emily Lindley, Mark E. Rentschler, Evalina L. Burger, Christopher M. J. Cain, Vikas V. Patel

Erschienen in: European Spine Journal | Ausgabe 6/2016

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Description of a novel method for evaluation of pedicle screws in 3 dimensions utilizing O-arm® and StealthStation® navigation; identifying sources of error, and pearls for more precise screw placement.

Methods

O-arm and StealthStation navigation were utilized to place pedicle screws. Initial and final O-arm scans were performed, and the projected pedicle probe track, projected pedicle screw track, and final screw position were saved for evaluation. They were compared to evaluate the precision of the system as well as overall accuracy of final screw placement.

Results

Thoracolumbar deformity patients were analyzed, with 153 of 158 screws in adequate position. Only 5 screws were malpositioned, requiring replacement or removal. All 5 were breached laterally and no neurologic or other complications were noted in any of these patients. This resulted in 97 % accuracy using the navigation system, and no neurological injuries or deficits. The average distance of the screw tip and angle of separation for the predicted path versus the final pedicle screw position were analyzed for precision. The mean screw tip distance from the projected tip was 6.43 mm, with a standard deviation of 3.49 mm when utilizing a navigated probe alone and 5.92 mm with a standard deviation of 3.50 mm using a navigated probe and navigated screwdriver (p = 0.23). Mean angle differences were 4.02° and 3.09° respectively (p < 0.01), with standard deviations of 2.63° and 2.12°.

Conclusions

This new technique evaluating precision of screw placement in 3 dimensions improves the ability to define screw placement. Pedicle screw position at final imaging showed the use of StealthStation navigation to be accurate and safe. As this is a preliminary evaluation, we have identified several factors affecting the precision of pedicle screw final position relative to that predicted with navigation.
Literatur
1.
Zurück zum Zitat Boucher HH (1959) A method of spinal fusion. J Bone Joint Surg Br 41-B:248–259PubMed Boucher HH (1959) A method of spinal fusion. J Bone Joint Surg Br 41-B:248–259PubMed
2.
Zurück zum Zitat King D (1948) Internal fixation for lumbosacral fusion. J Bone Joint Surg Am 30A:560–565PubMed King D (1948) Internal fixation for lumbosacral fusion. J Bone Joint Surg Am 30A:560–565PubMed
3.
Zurück zum Zitat Roy-Camille R, Roy-Camille M, Demeulenaere C (1970) Osteosynthesis of dorsal, lumbar, and lumbosacral spine with metallic plates screwed into vertebral pedicles and articular apophyses. La Presse medicale 78:1447–1448PubMed Roy-Camille R, Roy-Camille M, Demeulenaere C (1970) Osteosynthesis of dorsal, lumbar, and lumbosacral spine with metallic plates screwed into vertebral pedicles and articular apophyses. La Presse medicale 78:1447–1448PubMed
4.
Zurück zum Zitat Krag MH, Weaver DL, Beynnon BD, Haugh LD (1988) Morphometry of the thoracic and lumbar spine related to transpedicular screw placement for surgical spinal fixation. Spine 13:27–32CrossRefPubMed Krag MH, Weaver DL, Beynnon BD, Haugh LD (1988) Morphometry of the thoracic and lumbar spine related to transpedicular screw placement for surgical spinal fixation. Spine 13:27–32CrossRefPubMed
5.
Zurück zum Zitat Ugur HC, Attar A, Uz A, Tekdemir I, Egemen N, Genc Y (2001) Thoracic pedicle: surgical anatomic evaluation and relations. J Spinal Disord 14:39–45CrossRefPubMed Ugur HC, Attar A, Uz A, Tekdemir I, Egemen N, Genc Y (2001) Thoracic pedicle: surgical anatomic evaluation and relations. J Spinal Disord 14:39–45CrossRefPubMed
6.
Zurück zum Zitat Vaccaro AR, Rizzolo SJ, Allardyce TJ, Ramsey M, Salvo J, Balderston RA, Cotler JM (1995) Placement of pedicle screws in the thoracic spine. Part I: morphometric analysis of the thoracic vertebrae. J Bone Joint Surg Am 77:1193–1199PubMed Vaccaro AR, Rizzolo SJ, Allardyce TJ, Ramsey M, Salvo J, Balderston RA, Cotler JM (1995) Placement of pedicle screws in the thoracic spine. Part I: morphometric analysis of the thoracic vertebrae. J Bone Joint Surg Am 77:1193–1199PubMed
7.
Zurück zum Zitat Zindrick MR, Wiltse LL, Doornik A, Widell EH, Knight GW, Patwardhan AG, Thomas JC, Rothman SL, Fields BT (1987) Analysis of the morphometric characteristics of the thoracic and lumbar pedicles. Spine 12:160–166CrossRefPubMed Zindrick MR, Wiltse LL, Doornik A, Widell EH, Knight GW, Patwardhan AG, Thomas JC, Rothman SL, Fields BT (1987) Analysis of the morphometric characteristics of the thoracic and lumbar pedicles. Spine 12:160–166CrossRefPubMed
8.
9.
Zurück zum Zitat Liljenqvist UR, Link TM, Halm HF (2000) Morphometric analysis of thoracic and lumbar vertebrae in idiopathic scoliosis. Spine 25:1247–1253CrossRefPubMed Liljenqvist UR, Link TM, Halm HF (2000) Morphometric analysis of thoracic and lumbar vertebrae in idiopathic scoliosis. Spine 25:1247–1253CrossRefPubMed
10.
Zurück zum Zitat Cinotti G, Gumina S, Ripani M, Postacchini F (1999) Pedicle instrumentation in the thoracic spine. A morphometric and cadaveric study for placement of screws. Spine 24:114–119CrossRefPubMed Cinotti G, Gumina S, Ripani M, Postacchini F (1999) Pedicle instrumentation in the thoracic spine. A morphometric and cadaveric study for placement of screws. Spine 24:114–119CrossRefPubMed
11.
Zurück zum Zitat Esses SI, Sachs BL, Dreyzin V (1993) Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. Spine 18:2231–2238 (discussion 2238-2239) CrossRefPubMed Esses SI, Sachs BL, Dreyzin V (1993) Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. Spine 18:2231–2238 (discussion 2238-2239) CrossRefPubMed
12.
Zurück zum Zitat Lonstein JE, Denis F, Perra JH, Pinto MR, Smith MD, Winter RB (1999) Complications associated with pedicle screws. J Bone Joint Surg Am 81:1519–1528PubMed Lonstein JE, Denis F, Perra JH, Pinto MR, Smith MD, Winter RB (1999) Complications associated with pedicle screws. J Bone Joint Surg Am 81:1519–1528PubMed
13.
Zurück zum Zitat Vaccaro AR, Rizzolo SJ, Balderston RA, Allardyce TJ, Garfin SR, Dolinskas C, An HS (1995) Placement of pedicle screws in the thoracic spine. Part II: an anatomical and radiographic assessment. J Bone Joint Surg Am 77:1200–1206PubMed Vaccaro AR, Rizzolo SJ, Balderston RA, Allardyce TJ, Garfin SR, Dolinskas C, An HS (1995) Placement of pedicle screws in the thoracic spine. Part II: an anatomical and radiographic assessment. J Bone Joint Surg Am 77:1200–1206PubMed
14.
Zurück zum Zitat Weinstein JN, Spratt KF, Spengler D, Brick C, Reid S (1988) Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine 13:1012–1018CrossRefPubMed Weinstein JN, Spratt KF, Spengler D, Brick C, Reid S (1988) Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine 13:1012–1018CrossRefPubMed
15.
Zurück zum Zitat Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine 15:11–14CrossRefPubMed Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine 15:11–14CrossRefPubMed
16.
Zurück zum Zitat Xu R, Ebraheim NA, Ou Y, Yeasting RA (1998) Anatomic considerations of pedicle screw placement in the thoracic spine. Roy-Camille technique versus open-lamina technique. Spine 23:1065–1068CrossRefPubMed Xu R, Ebraheim NA, Ou Y, Yeasting RA (1998) Anatomic considerations of pedicle screw placement in the thoracic spine. Roy-Camille technique versus open-lamina technique. Spine 23:1065–1068CrossRefPubMed
17.
Zurück zum Zitat Xu R, Ebraheim NA, Shepherd ME, Yeasting RA (1999) Thoracic pedicle screw placement guided by computed tomographic measurements. J Spinal Disord 12:222–226PubMed Xu R, Ebraheim NA, Shepherd ME, Yeasting RA (1999) Thoracic pedicle screw placement guided by computed tomographic measurements. J Spinal Disord 12:222–226PubMed
18.
Zurück zum Zitat Castro WH, Halm H, Jerosch J, Malms J, Steinbeck J, Blasius S (1996) Accuracy of pedicle screw placement in lumbar vertebrae. Spine 21:1320–1324CrossRefPubMed Castro WH, Halm H, Jerosch J, Malms J, Steinbeck J, Blasius S (1996) Accuracy of pedicle screw placement in lumbar vertebrae. Spine 21:1320–1324CrossRefPubMed
19.
Zurück zum Zitat Belmont PJ Jr, Klemme WR, Dhawan A, Polly DW Jr (2001) In vivo accuracy of thoracic pedicle screws. Spine 26:2340–2346CrossRefPubMed Belmont PJ Jr, Klemme WR, Dhawan A, Polly DW Jr (2001) In vivo accuracy of thoracic pedicle screws. Spine 26:2340–2346CrossRefPubMed
20.
Zurück zum Zitat Liljenqvist UR, Halm HF, Link TM (1997) Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis. Spine 22:2239–2245CrossRefPubMed Liljenqvist UR, Halm HF, Link TM (1997) Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis. Spine 22:2239–2245CrossRefPubMed
21.
Zurück zum Zitat Suk SI, Lee CK, Kim WJ, Chung YJ, Park YB (1995) Segmental pedicle screw fixation in the treatment of thoracic idiopathic scoliosis. Spine 20:1399–1405CrossRefPubMed Suk SI, Lee CK, Kim WJ, Chung YJ, Park YB (1995) Segmental pedicle screw fixation in the treatment of thoracic idiopathic scoliosis. Spine 20:1399–1405CrossRefPubMed
22.
Zurück zum Zitat Belmont PJ Jr, Klemme WR, Robinson M, Polly DW Jr (2002) Accuracy of thoracic pedicle screws in patients with and without coronal plane spinal deformities. Spine 27:1558–1566CrossRefPubMed Belmont PJ Jr, Klemme WR, Robinson M, Polly DW Jr (2002) Accuracy of thoracic pedicle screws in patients with and without coronal plane spinal deformities. Spine 27:1558–1566CrossRefPubMed
23.
Zurück zum Zitat Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D (2000) Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J 9:235–240CrossRefPubMedPubMedCentral Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D (2000) Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J 9:235–240CrossRefPubMedPubMedCentral
24.
Zurück zum Zitat Merloz P, Tonetti J, Pittet L, Coulomb M, Lavallee S, Sautot P (1998) Pedicle screw placement using image guided techniques. Clin Orthop Rel Res 354:39–48CrossRef Merloz P, Tonetti J, Pittet L, Coulomb M, Lavallee S, Sautot P (1998) Pedicle screw placement using image guided techniques. Clin Orthop Rel Res 354:39–48CrossRef
26.
Zurück zum Zitat Youkilis AS, Quint DJ, McGillicuddy JE, Papadopoulos SM (2001) Stereotactic navigation for placement of pedicle screws in the thoracic spine. Neurosurgery 48:771–778 (discussion 778-779) PubMed Youkilis AS, Quint DJ, McGillicuddy JE, Papadopoulos SM (2001) Stereotactic navigation for placement of pedicle screws in the thoracic spine. Neurosurgery 48:771–778 (discussion 778-779) PubMed
27.
Zurück zum Zitat Grutzner PA, Beutler T, Wendl K, von Recum J, Wentzensen A, Nolte LP (2004) Intraoperative three-dimensional navigation for pedicle screw placement. Der Chirurg; Zeitschrift fur alle Gebiete der operativen Medizen 75:967–975. doi:10.1007/s00104-004-0944-3 CrossRefPubMed Grutzner PA, Beutler T, Wendl K, von Recum J, Wentzensen A, Nolte LP (2004) Intraoperative three-dimensional navigation for pedicle screw placement. Der Chirurg; Zeitschrift fur alle Gebiete der operativen Medizen 75:967–975. doi:10.​1007/​s00104-004-0944-3 CrossRefPubMed
28.
Zurück zum Zitat Holly LT, Foley KT (2003) Three-dimensional fluoroscopy-guided percutaneous thoracolumbar pedicle screw placement. Technical note. J Neurosurg 99:324–329PubMed Holly LT, Foley KT (2003) Three-dimensional fluoroscopy-guided percutaneous thoracolumbar pedicle screw placement. Technical note. J Neurosurg 99:324–329PubMed
30.
Zurück zum Zitat Van de Kelft E, Costa F, Van der Planken D, Schils F (2012) A prospective multicenter registry on the accuracy of pedicle screw placement in the thoracic, lumbar, and sacral levels with the use of the O-arm imaging system and StealthStation Navigation. Spine 37:E1580–E1587. doi:10.1097/BRS.0b013e318271b1fa CrossRefPubMed Van de Kelft E, Costa F, Van der Planken D, Schils F (2012) A prospective multicenter registry on the accuracy of pedicle screw placement in the thoracic, lumbar, and sacral levels with the use of the O-arm imaging system and StealthStation Navigation. Spine 37:E1580–E1587. doi:10.​1097/​BRS.​0b013e318271b1fa​ CrossRefPubMed
31.
Zurück zum Zitat Amiot LP, Lang K, Putzier M, Zippel H, Labelle H (2000) Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine 25:606–614CrossRefPubMed Amiot LP, Lang K, Putzier M, Zippel H, Labelle H (2000) Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine 25:606–614CrossRefPubMed
32.
Zurück zum Zitat Kotani Y, Abumi K, Ito M, Takahata M, Sudo H, Ohshima S, Minami A (2007) Accuracy analysis of pedicle screw placement in posterior scoliosis surgery: comparison between conventional fluoroscopic and computer-assisted technique. Spine 32:1543–1550. doi:10.1097/BRS.0b013e318068661e CrossRefPubMed Kotani Y, Abumi K, Ito M, Takahata M, Sudo H, Ohshima S, Minami A (2007) Accuracy analysis of pedicle screw placement in posterior scoliosis surgery: comparison between conventional fluoroscopic and computer-assisted technique. Spine 32:1543–1550. doi:10.​1097/​BRS.​0b013e318068661e​ CrossRefPubMed
33.
Zurück zum Zitat Gelalis ID, Paschos NK, Pakos EE, Politis AN, Arnaoutoglou CM, Karageorgos AC, Ploumis A, Xenakis TA (2012) Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. Eur Spine J 21:247–255. doi:10.1007/s00586-011-2011-3 CrossRefPubMedPubMedCentral Gelalis ID, Paschos NK, Pakos EE, Politis AN, Arnaoutoglou CM, Karageorgos AC, Ploumis A, Xenakis TA (2012) Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. Eur Spine J 21:247–255. doi:10.​1007/​s00586-011-2011-3 CrossRefPubMedPubMedCentral
34.
Zurück zum Zitat Li B, Jiang B, Fu Z, Zhang D, Wang T (2004) Accurate determination of isthmus of lumbar pedicle: a morphometric study using reformatted computed tomographic images. Spine 29:2438–2444CrossRefPubMed Li B, Jiang B, Fu Z, Zhang D, Wang T (2004) Accurate determination of isthmus of lumbar pedicle: a morphometric study using reformatted computed tomographic images. Spine 29:2438–2444CrossRefPubMed
35.
36.
37.
Zurück zum Zitat Abdullah KG, Bishop FS, Lubelski D, Steinmetz MP, Benzel EC, Mroz TE (2012) Radiation exposure to the spine surgeon in lumbar and thoracolumbar fusions with the use of an intraoperative computed tomographic 3-dimensional imaging system. Spine 37:E1074–E1078. doi:10.1097/BRS.0b013e31825786d8 CrossRefPubMed Abdullah KG, Bishop FS, Lubelski D, Steinmetz MP, Benzel EC, Mroz TE (2012) Radiation exposure to the spine surgeon in lumbar and thoracolumbar fusions with the use of an intraoperative computed tomographic 3-dimensional imaging system. Spine 37:E1074–E1078. doi:10.​1097/​BRS.​0b013e31825786d8​ CrossRefPubMed
39.
Zurück zum Zitat Smith HE, Welsch MD, Sasso RC, Vaccaro AR (2008) Comparison of radiation exposure in lumbar pedicle screw placement with fluoroscopy vs computer-assisted image guidance with intraoperative three-dimensional imaging. J Spinal Cord Med 31:532–537PubMedPubMedCentral Smith HE, Welsch MD, Sasso RC, Vaccaro AR (2008) Comparison of radiation exposure in lumbar pedicle screw placement with fluoroscopy vs computer-assisted image guidance with intraoperative three-dimensional imaging. J Spinal Cord Med 31:532–537PubMedPubMedCentral
40.
Zurück zum Zitat Villavicencio AT, Burneikiene S, Bulsara KR, Thramann JJ (2005) Utility of computerized isocentric fluoroscopy for minimally invasive spinal surgical techniques. J Spinal Disord Tech 18:369–375CrossRefPubMed Villavicencio AT, Burneikiene S, Bulsara KR, Thramann JJ (2005) Utility of computerized isocentric fluoroscopy for minimally invasive spinal surgical techniques. J Spinal Disord Tech 18:369–375CrossRefPubMed
41.
Zurück zum Zitat Garber ST, Bisson EF, Schmidt MH (2012) Comparison of three-dimensional fluoroscopy versus postoperative computed tomography for the assessment of accurate screw placement after instrumented spine surgery. Glob Spine J 2:95–98. doi:10.1055/s-0032-1319775 CrossRef Garber ST, Bisson EF, Schmidt MH (2012) Comparison of three-dimensional fluoroscopy versus postoperative computed tomography for the assessment of accurate screw placement after instrumented spine surgery. Glob Spine J 2:95–98. doi:10.​1055/​s-0032-1319775 CrossRef
44.
Zurück zum Zitat Petrov IE, Nikolov HN, Hodsworth DW, Drangova M (2011) Image performance evaluation of a 3D surgical imaging platform. Proc SPIE 7961:79615OCrossRef Petrov IE, Nikolov HN, Hodsworth DW, Drangova M (2011) Image performance evaluation of a 3D surgical imaging platform. Proc SPIE 7961:79615OCrossRef
Metadaten
Titel
A new 3-dimensional method for measuring precision in surgical navigation and methods to optimize navigation accuracy
verfasst von
Christopher J. Kleck
Ian Cullilmore
Matthew LaFleur
Emily Lindley
Mark E. Rentschler
Evalina L. Burger
Christopher M. J. Cain
Vikas V. Patel
Publikationsdatum
22.09.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
European Spine Journal / Ausgabe 6/2016
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-015-4235-0

Weitere Artikel der Ausgabe 6/2016

European Spine Journal 6/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.