Skip to main content
Erschienen in: European Journal of Orthopaedic Surgery & Traumatology 8/2008

01.11.2008 | Original Article

Digital pre-operative templating is more accurate in total hip replacement compared to analogue templating

verfasst von: M. Hossain, J. Lewis, A. Sinha

Erschienen in: European Journal of Orthopaedic Surgery & Traumatology | Ausgabe 8/2008

Einloggen, um Zugang zu erhalten

Abstract

We prospectively evaluated the accuracy of digital compared to analogue pre-operative templating in 50 consecutive primary hip replacements between April 2006 and June 2007. The senior author pre-operatively templated implant size using TraumaCad (Orthocrat Limited, Israel). Thirty-one Exeter primary hip and 19 hybrid hip replacements were performed. Hips were templated using radiographs calibrated against a spherical metal ball. For each hip, an AP pelvis view was used. Acetabular implants used were either Trident PSL or Exeter contemporary cup (Stryker). Femoral stem was Exeter (Stryker). Predicted implant sizes were documented. Post-operatively, the predicted implant size was compared to the implanted components. All post-operative films showed good fit of components and there were no intraoperative or post-operative fractures. The intra-rater reliability (ICC) of analogue templating was 0.96 and digital templating was 0.90. Accurate templating score for acetabular cup was 46% (digital) 43% (analogue), femoral offset was 80% (digital) 70% (analogue), femoral stem was 76% (digital) 60% (analogue). The differences between templating and actual implant sizes were plotted in Bland–Altman plot. Digital templating produced narrower confidence interval compared to analogue templating. Digital templating proved to be statistically, significantly more accurate compared to analogue templating for acetabluar cup and femoral stem. Our data indicate that digital templating is more reliable in predicting actual implant sizes for total hip arthroplasty when performed by the operating surgeon.
Literatur
1.
Zurück zum Zitat Bertram T, Diercks RL, van Ooijen PM, Horn JR (2005) Comparison of analog and digital preoperative planning in total and knee arthroplasties. A prospective study of 173 hips and 65 total knees. Acta Orthop 76:78CrossRef Bertram T, Diercks RL, van Ooijen PM, Horn JR (2005) Comparison of analog and digital preoperative planning in total and knee arthroplasties. A prospective study of 173 hips and 65 total knees. Acta Orthop 76:78CrossRef
2.
Zurück zum Zitat Della Valle AG, Padgett DE, Salvatti EA (2005) Preoperative planning for primary total hip arthroplasty. J Am Acad Orthop Surg 13:455PubMed Della Valle AG, Padgett DE, Salvatti EA (2005) Preoperative planning for primary total hip arthroplasty. J Am Acad Orthop Surg 13:455PubMed
3.
Zurück zum Zitat Eggli S, Pisan M, Muller ME (1998) The value of preoperative planning for total hip arthroplasty. J Bone Join Surg 80-B:382CrossRef Eggli S, Pisan M, Muller ME (1998) The value of preoperative planning for total hip arthroplasty. J Bone Join Surg 80-B:382CrossRef
4.
Zurück zum Zitat Gonzalez Della Valle A, Slullitel G, Piccaluga F, Salvati EA (2005) The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty. J Arthroplasty 20:51PubMedCrossRef Gonzalez Della Valle A, Slullitel G, Piccaluga F, Salvati EA (2005) The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty. J Arthroplasty 20:51PubMedCrossRef
5.
Zurück zum Zitat Hossain M, Sinha AK (2007) A technique to avoid leg length discrepancy in total hip replacement. Ann R Coll Surg Engl 89:314PubMedCrossRef Hossain M, Sinha AK (2007) A technique to avoid leg length discrepancy in total hip replacement. Ann R Coll Surg Engl 89:314PubMedCrossRef
6.
Zurück zum Zitat Knight JL, Atwater RD (1992) Preoperative planning for total hip arthroplasty. Quantitating its utility and precision. J Arthroplasty 7(suppl):403PubMedCrossRef Knight JL, Atwater RD (1992) Preoperative planning for total hip arthroplasty. Quantitating its utility and precision. J Arthroplasty 7(suppl):403PubMedCrossRef
7.
Zurück zum Zitat Landis RJ, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159PubMedCrossRef Landis RJ, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159PubMedCrossRef
8.
Zurück zum Zitat Martin J, Marsh JL, Nepola JV et al (2000) Radiographic fracture assessments: which ones can we reliably make? J Orthopedic Trauma 14:379CrossRef Martin J, Marsh JL, Nepola JV et al (2000) Radiographic fracture assessments: which ones can we reliably make? J Orthopedic Trauma 14:379CrossRef
9.
Zurück zum Zitat Oddy MJ, Jones MJ, Pendegrass CJ (2006) Assessment of reproducibility and accuracy in templating hybrid total hip arthroplasty using digital radiographs. J Bone Joint Surg 88-B:581CrossRef Oddy MJ, Jones MJ, Pendegrass CJ (2006) Assessment of reproducibility and accuracy in templating hybrid total hip arthroplasty using digital radiographs. J Bone Joint Surg 88-B:581CrossRef
10.
Zurück zum Zitat Remington RD, Schork MA (1970) Statistics with applications to the biological and health sciences. Prentice-Hall, Englewood Cliffs, p 188 Remington RD, Schork MA (1970) Statistics with applications to the biological and health sciences. Prentice-Hall, Englewood Cliffs, p 188
11.
Zurück zum Zitat Suh KT, Cheon SJ, Kim DW (2004) Comparison of preoperative templating with postoperative assessment in cementless total hip arthroplasty. Acta Orthop Scand 75:40PubMedCrossRef Suh KT, Cheon SJ, Kim DW (2004) Comparison of preoperative templating with postoperative assessment in cementless total hip arthroplasty. Acta Orthop Scand 75:40PubMedCrossRef
12.
Zurück zum Zitat Wimsey S, Pickard R, Shaw G (2006) Accurate scaling of digital radiographs of the pelvis. A prospective trial of two methods. J Bone Joint Surg 88:1508CrossRef Wimsey S, Pickard R, Shaw G (2006) Accurate scaling of digital radiographs of the pelvis. A prospective trial of two methods. J Bone Joint Surg 88:1508CrossRef
Metadaten
Titel
Digital pre-operative templating is more accurate in total hip replacement compared to analogue templating
verfasst von
M. Hossain
J. Lewis
A. Sinha
Publikationsdatum
01.11.2008
Verlag
Springer-Verlag
Erschienen in
European Journal of Orthopaedic Surgery & Traumatology / Ausgabe 8/2008
Print ISSN: 1633-8065
Elektronische ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-008-0356-z

Weitere Artikel der Ausgabe 8/2008

European Journal of Orthopaedic Surgery & Traumatology 8/2008 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.