Skip to main content
Erschienen in: European Journal of Orthopaedic Surgery & Traumatology 4/2016

27.04.2016 | Original Article • HIP - FRACTURES

Effect of varus and valgus alignment on implant loading after proximal femur fracture fixation

verfasst von: Meir Marmor, Kate Liddle, Jenni Buckley, Amir Matityahu

Erschienen in: European Journal of Orthopaedic Surgery & Traumatology | Ausgabe 4/2016

Einloggen, um Zugang zu erhalten

Abstract

Introduction

More than 10 % of proximal femur fractures repaired with either a sliding hip screw and side plate (SHS-P) or a sliding hip screw and intramedullary nail (SHS-IMN) demonstrate varus malreduction. The purpose of this study was to compare the effect of varus or valgus loading on comminuted intertrochanteric fractures repaired with SHS-P or SHS-IMN constructs.

Methods

Unstable intertrochanteric fractures with segmental comminution were generated in 12 cadaver proximal femurs, six of which were fixed with an SHS-P and six with an SHS-IMN. Both implants had a strain gauge at the lag screw-nail–plate interface to assess implant load bearing. The load on the implants was measured with the specimens in neutral position and at 5°, 10°, and 15° of varus and valgus.

Results

Loads on both SHS-IMN and SHS-P constructs were significantly increased when loading the implants in varus and significantly decreased when loading the implants in valgus. Unlike the SHS-IMN, the SHS-P trended toward increased load bearing at 15° varus (159.1 vs. 118.5 %, P = .065) and trended toward less load bearing at 15° valgus (42.3 vs. 59.8 %, P = .06). Conclusions: Regardless of implant choice, avoiding varus loading on the fixation construct reduces the load on the implant. SHS-P constructs may be more affected by varus or valgus malalignment than SHS-IMN constructs.
Literatur
1.
Zurück zum Zitat Lindskog DM, Baumgaertner MR (2004) Unstable intertrochanteric hip fractures in the elderly. J Am Acad Orthop Surg 12:179–190CrossRefPubMed Lindskog DM, Baumgaertner MR (2004) Unstable intertrochanteric hip fractures in the elderly. J Am Acad Orthop Surg 12:179–190CrossRefPubMed
2.
Zurück zum Zitat Bucholz RW, Heckman JD, Court-Brown CM, Tornetta P (2010) Intertrochanteric fractures of the hip. In: Court-Brown C, Heckman JD, McKee M, McQueen MM, Ricci W, Tornetta III P (eds) Rockwood and green’s fractures in adults, 7th Edn. Lippincott Williams & Wilkins, pp 1597–1640 Bucholz RW, Heckman JD, Court-Brown CM, Tornetta P (2010) Intertrochanteric fractures of the hip. In: Court-Brown C, Heckman JD, McKee M, McQueen MM, Ricci W, Tornetta III P (eds) Rockwood and green’s fractures in adults, 7th Edn. Lippincott Williams & Wilkins, pp 1597–1640
3.
Zurück zum Zitat Madsen JE, Nass L, Aune AK, Alho A, Ekeland A, Stromsoe K (1998) Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the gamma nail and compression hip screw. J Orthop Trauma 12:241–248CrossRefPubMed Madsen JE, Nass L, Aune AK, Alho A, Ekeland A, Stromsoe K (1998) Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the gamma nail and compression hip screw. J Orthop Trauma 12:241–248CrossRefPubMed
4.
Zurück zum Zitat Simmermacher RKJ, Ljungqvist J, Bail H et al (2008) The new proximal femoral nail antirotation (PFNA) in daily practice: results of a multicentre clinical study. Injury 39:932–993CrossRefPubMed Simmermacher RKJ, Ljungqvist J, Bail H et al (2008) The new proximal femoral nail antirotation (PFNA) in daily practice: results of a multicentre clinical study. Injury 39:932–993CrossRefPubMed
5.
Zurück zum Zitat Laros GS, Moore JF (1974) Complications of fixation in intertrochanteric fractures. Clin Orthop Relat Res 101:110–119PubMed Laros GS, Moore JF (1974) Complications of fixation in intertrochanteric fractures. Clin Orthop Relat Res 101:110–119PubMed
6.
Zurück zum Zitat Schipper IB, Marti RK, Van Der Werken C (2004) Unstable trochanteric femoral fractures: extramedullary or intramedullary fixation: review of literature. Injury 35:142–151CrossRefPubMed Schipper IB, Marti RK, Van Der Werken C (2004) Unstable trochanteric femoral fractures: extramedullary or intramedullary fixation: review of literature. Injury 35:142–151CrossRefPubMed
7.
Zurück zum Zitat Baumgaertner MR, Curtin SL, Lindskog DM, Keggi JM (1995) The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Jt Surg Am 77:1058–1064 Baumgaertner MR, Curtin SL, Lindskog DM, Keggi JM (1995) The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Jt Surg Am 77:1058–1064
8.
Zurück zum Zitat Ruecker AH, Rupprecht M, Gruber M, Gebauer M, Barvencik F, Briem D, Rueger JM (2009) The treatment of intertrochanteric fractures: results using an intramedullary nail with integrated cephalocervical screws and linear compression. J Orthop Trauma 23(1):22–30CrossRefPubMed Ruecker AH, Rupprecht M, Gruber M, Gebauer M, Barvencik F, Briem D, Rueger JM (2009) The treatment of intertrochanteric fractures: results using an intramedullary nail with integrated cephalocervical screws and linear compression. J Orthop Trauma 23(1):22–30CrossRefPubMed
9.
Zurück zum Zitat Utrilla AL, Reig JS, Muñoz FM, Tufanisco CB (2005) Trochanteric gamma nail and compression hip screw for trochanteric fractures: a randomized, prospective, comparative study in 210 elderly patients with a new design of the gamma nail. J Orthop Trauma 19:229–233CrossRefPubMed Utrilla AL, Reig JS, Muñoz FM, Tufanisco CB (2005) Trochanteric gamma nail and compression hip screw for trochanteric fractures: a randomized, prospective, comparative study in 210 elderly patients with a new design of the gamma nail. J Orthop Trauma 19:229–233CrossRefPubMed
10.
Zurück zum Zitat Barton TM, Gleeson R, Topliss C, Greenwood R, Harries WJ, Chesser TJS (2010) A comparison of the long gamma nail with the sliding hip screw for the treatment of AO/OTA 31-A2 fractures of the proximal part of the femur: a prospective randomized trial. J Bone Jt Surg Am 92(4):792–798CrossRef Barton TM, Gleeson R, Topliss C, Greenwood R, Harries WJ, Chesser TJS (2010) A comparison of the long gamma nail with the sliding hip screw for the treatment of AO/OTA 31-A2 fractures of the proximal part of the femur: a prospective randomized trial. J Bone Jt Surg Am 92(4):792–798CrossRef
11.
Zurück zum Zitat Jin WJ, Dai LY, Cui YM, Zhou Q, Jiang LS, Lu H (2005) Reliability of classification systems for intertrochanteric fractures of the proximal femur in experienced orthopaedic surgeons. Injury 36(7):858–861CrossRefPubMed Jin WJ, Dai LY, Cui YM, Zhou Q, Jiang LS, Lu H (2005) Reliability of classification systems for intertrochanteric fractures of the proximal femur in experienced orthopaedic surgeons. Injury 36(7):858–861CrossRefPubMed
12.
Zurück zum Zitat Saudan M, Lübbeke A, Sadowski C, Riand N, Stern R, Hoffmeyer P (2002) Petrochanteric fractures: Is there an advantage to an intramedullary nail? A randomized, prospective study of 206 patients comparing the dynamic hip screw and proximal femoral nail. J Orthop Trauma 16(6):386–393CrossRefPubMed Saudan M, Lübbeke A, Sadowski C, Riand N, Stern R, Hoffmeyer P (2002) Petrochanteric fractures: Is there an advantage to an intramedullary nail? A randomized, prospective study of 206 patients comparing the dynamic hip screw and proximal femoral nail. J Orthop Trauma 16(6):386–393CrossRefPubMed
13.
Zurück zum Zitat Stern R (2007) Are there advances in the treatment of extracapsular hip fractures in the elderly? Injury 38(3):S77–S87CrossRefPubMed Stern R (2007) Are there advances in the treatment of extracapsular hip fractures in the elderly? Injury 38(3):S77–S87CrossRefPubMed
14.
Zurück zum Zitat Baumgaertner MR, Oetgen ME (2009) Chapter 9: Intertrochanteric hip fractures. Skeletal trauma: basic science, management and reconstruction, 4th edn. Elsevier, Philadelphia, pp 1913–1956CrossRef Baumgaertner MR, Oetgen ME (2009) Chapter 9: Intertrochanteric hip fractures. Skeletal trauma: basic science, management and reconstruction, 4th edn. Elsevier, Philadelphia, pp 1913–1956CrossRef
15.
Zurück zum Zitat Cummings SR, Rubin SM, Black D (1990) The future of hip fractures in the United States: numbers, costs, and potential effects of postmenopausal estrogen. Clin Orthop 252:163–166PubMed Cummings SR, Rubin SM, Black D (1990) The future of hip fractures in the United States: numbers, costs, and potential effects of postmenopausal estrogen. Clin Orthop 252:163–166PubMed
16.
Zurück zum Zitat Koval KJ, Aharonoff GB, Rokito AS, Lyon T, Zuckerman JD (1996) Patients with femoral neck and intertrochanteric fractures. Are they the same? Clin Orthop Relat Res 330:166–172CrossRefPubMed Koval KJ, Aharonoff GB, Rokito AS, Lyon T, Zuckerman JD (1996) Patients with femoral neck and intertrochanteric fractures. Are they the same? Clin Orthop Relat Res 330:166–172CrossRefPubMed
17.
Zurück zum Zitat Tia et al (2008) A novel technique for measuring pedicle screw forces in situ. Presented at ASME summer Bioengineering conference, Marco Islands, Florida Tia et al (2008) A novel technique for measuring pedicle screw forces in situ. Presented at ASME summer Bioengineering conference, Marco Islands, Florida
18.
Zurück zum Zitat Eberle S, Bauer C, Gerber C et al (2010) The stability of a hip fracture determines the fatigue of an intramedullary nail. Proc Inst Mech Eng H 224:577–584CrossRefPubMed Eberle S, Bauer C, Gerber C et al (2010) The stability of a hip fracture determines the fatigue of an intramedullary nail. Proc Inst Mech Eng H 224:577–584CrossRefPubMed
19.
Zurück zum Zitat Bay BK, Hamel AJ, Olson SA et al (1997) Statically equivalent load and support conditions produce different hip joint contact pressures and periacetabular strains. J Biomech 30:193–196CrossRefPubMed Bay BK, Hamel AJ, Olson SA et al (1997) Statically equivalent load and support conditions produce different hip joint contact pressures and periacetabular strains. J Biomech 30:193–196CrossRefPubMed
20.
Zurück zum Zitat Haidukewych GJ, Israel TA, Berry DJ (2001) Reverse obliquity fractures of the intertrochanteric region of the femur. J Bone Joint Surg Am 83:643–650PubMed Haidukewych GJ, Israel TA, Berry DJ (2001) Reverse obliquity fractures of the intertrochanteric region of the femur. J Bone Joint Surg Am 83:643–650PubMed
21.
Zurück zum Zitat Marmor M, Liddle K, Pekmezci M, Buckley J, Matityahu A (2013) The effect of fracture pattern stability and post-reduction alignment on implant loading in OTA type 31-A2 proximal femur fractures. J Orthop Trauma 27(12):683–689CrossRefPubMed Marmor M, Liddle K, Pekmezci M, Buckley J, Matityahu A (2013) The effect of fracture pattern stability and post-reduction alignment on implant loading in OTA type 31-A2 proximal femur fractures. J Orthop Trauma 27(12):683–689CrossRefPubMed
22.
Zurück zum Zitat Parker MJ, Handoll HH (2008) Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Cochrane Database Syst Rev 16(3):CD000093 Parker MJ, Handoll HH (2008) Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Cochrane Database Syst Rev 16(3):CD000093
23.
Zurück zum Zitat Leung KS, So WS, Shen WY, Hui PW (1992) Gamma nails and dynamic hip screws for peritrochanteric fractures. A randomised prospective study in elderly patients. J Bone Jt Surg Br 74(3):345–351 Leung KS, So WS, Shen WY, Hui PW (1992) Gamma nails and dynamic hip screws for peritrochanteric fractures. A randomised prospective study in elderly patients. J Bone Jt Surg Br 74(3):345–351
24.
Zurück zum Zitat O’Brien PJ, Meek RN, Blachut PA, Broekhuyse HM, Sabharwal S (1995) Fixation of intertrochanteric hip fractures: gamma nail versus dynamic hip screw. A randomised, prospective study. Can J Surg 38(6):516–520PubMed O’Brien PJ, Meek RN, Blachut PA, Broekhuyse HM, Sabharwal S (1995) Fixation of intertrochanteric hip fractures: gamma nail versus dynamic hip screw. A randomised, prospective study. Can J Surg 38(6):516–520PubMed
25.
Zurück zum Zitat Park SR, Kang JS, Kim HS, Lee WH (1998) Treatment of intertrochanteric fracture with the gamma AP locking nail or by a compression hip screw—a randomised prospective trial. Int Orthop 22(3):157–160CrossRefPubMedPubMedCentral Park SR, Kang JS, Kim HS, Lee WH (1998) Treatment of intertrochanteric fracture with the gamma AP locking nail or by a compression hip screw—a randomised prospective trial. Int Orthop 22(3):157–160CrossRefPubMedPubMedCentral
26.
Zurück zum Zitat Ahrengart L, Tornkvist H, Fornander P, Thorngren KG, Pasanen L, Wahlstrom P et al (2002) A randomized study of the compression hip screw and gamma nail in 426 fractures. Clin Orthop Relat Res 401:209–222CrossRefPubMed Ahrengart L, Tornkvist H, Fornander P, Thorngren KG, Pasanen L, Wahlstrom P et al (2002) A randomized study of the compression hip screw and gamma nail in 426 fractures. Clin Orthop Relat Res 401:209–222CrossRefPubMed
27.
Zurück zum Zitat Rosenblum SF, Zuckerman JD, Kummer FJ, Tam BS (1992) A biomechanical evaluation of the gamma nail. J Bone Jt Surg Br 74(3):352–357 Rosenblum SF, Zuckerman JD, Kummer FJ, Tam BS (1992) A biomechanical evaluation of the gamma nail. J Bone Jt Surg Br 74(3):352–357
Metadaten
Titel
Effect of varus and valgus alignment on implant loading after proximal femur fracture fixation
verfasst von
Meir Marmor
Kate Liddle
Jenni Buckley
Amir Matityahu
Publikationsdatum
27.04.2016
Verlag
Springer Paris
Erschienen in
European Journal of Orthopaedic Surgery & Traumatology / Ausgabe 4/2016
Print ISSN: 1633-8065
Elektronische ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-016-1746-2

Weitere Artikel der Ausgabe 4/2016

European Journal of Orthopaedic Surgery & Traumatology 4/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.