Skip to main content
Erschienen in: Clinical Oral Investigations 5/2011

01.10.2011 | Original Article

Measurements on 3D models of human skulls derived from two different cone beam CT scanners

verfasst von: Olivier J. C. van Vlijmen, Frits A. Rangel, Stefaan J. Bergé, Ewald M. Bronkhorst, Alfred G. Becking, Anne Marie Kuijpers-Jagtman

Erschienen in: Clinical Oral Investigations | Ausgabe 5/2011

Einloggen, um Zugang zu erhalten

Abstract

The aims of this study were to compare measurements on three-dimensional (3D) models of human skulls derived from two different cone beam CT scanners (CBCT) and to evaluate if the used hardware can influence the performed measurements. CBCT scans of 40 dry human skulls with both the i-CAT™ and the Iluma™ cone beam CT scanners were made. From the CBCT scans, 3D models were constructed. One operator identified 19 landmarks five times on both types of 3D models with a time interval of 1 week. Intra-observer reliability was high for most measurements. There was a statistically significant and clinically relevant difference for some measurements between constructed 3D models of the same skull from the two different CBCT devices. Used hardware for scanning might influence the measurements performed. This means that care should be taken when interpreting measurements made on CBCT 3D models derived from different CBCT devices.
Literatur
1.
Zurück zum Zitat Broadbent BH (1931) A new X-ray technique and its application to orthodontia. Angle Orthod 1:45–66 Broadbent BH (1931) A new X-ray technique and its application to orthodontia. Angle Orthod 1:45–66
2.
Zurück zum Zitat Hofrath H (1931) Bedeutung der Röntgenfern und Abstands Aufnahme für die Diagnostik der Kieferanomalien. Fortschr Orthod 1:231–258 Hofrath H (1931) Bedeutung der Röntgenfern und Abstands Aufnahme für die Diagnostik der Kieferanomalien. Fortschr Orthod 1:231–258
3.
Zurück zum Zitat Rangel FA, Maal TJ, Bergé SJ, van Vlijmen OJ, Plooij JM, Schutyser F, Kuijpers-Jagtman AM (2008) Integration of digital dental casts in 3-dimensional facial photographs. Am J Orthod Dentofacial Orthop 134:820–826PubMedCrossRef Rangel FA, Maal TJ, Bergé SJ, van Vlijmen OJ, Plooij JM, Schutyser F, Kuijpers-Jagtman AM (2008) Integration of digital dental casts in 3-dimensional facial photographs. Am J Orthod Dentofacial Orthop 134:820–826PubMedCrossRef
4.
Zurück zum Zitat Silva MA, Wolf U, Heinicke F, Bumann A, Visser H, Hirsch E (2008) Cone-beam computed tomography for routine orthodontic treatment planning: a radiation dose evaluation. Am J Orthod Dentofacial Orthop 133(640):e1–e5PubMed Silva MA, Wolf U, Heinicke F, Bumann A, Visser H, Hirsch E (2008) Cone-beam computed tomography for routine orthodontic treatment planning: a radiation dose evaluation. Am J Orthod Dentofacial Orthop 133(640):e1–e5PubMed
5.
Zurück zum Zitat Hajeer MY, Ayoub AF, Millett DT, Bock M, Siebert JP (2002) Three-dimensional imaging in orthognathic surgery: the clinical application of a new method. Int J Adult Orthodon Orthognath Surg 17:318–330PubMed Hajeer MY, Ayoub AF, Millett DT, Bock M, Siebert JP (2002) Three-dimensional imaging in orthognathic surgery: the clinical application of a new method. Int J Adult Orthodon Orthognath Surg 17:318–330PubMed
6.
Zurück zum Zitat Swennen GRJ, Schutyser F (2007) Three-dimensional virtual approach to diagnosis and treatment planning of maxillo-facial deformity. In: Bell WH, Guerrero CA (eds) Distraction Osteogenesis of the Facial Skeleton. BC Decker Inc, Hamilton, pp 55–79 Swennen GRJ, Schutyser F (2007) Three-dimensional virtual approach to diagnosis and treatment planning of maxillo-facial deformity. In: Bell WH, Guerrero CA (eds) Distraction Osteogenesis of the Facial Skeleton. BC Decker Inc, Hamilton, pp 55–79
7.
Zurück zum Zitat Ludlow JB, Davies-Ludlow LE, Brooks SL, Howerton WB (2006) Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and I-CAT. Dentomaxillofac Radiol 35:219–226PubMedCrossRef Ludlow JB, Davies-Ludlow LE, Brooks SL, Howerton WB (2006) Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and I-CAT. Dentomaxillofac Radiol 35:219–226PubMedCrossRef
8.
Zurück zum Zitat Ludlow JB, Ivanovic M (2008) Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 106:106–114PubMedCrossRef Ludlow JB, Ivanovic M (2008) Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 106:106–114PubMedCrossRef
9.
Zurück zum Zitat Greiner M, Greiner A, Hirschfelder U (2007) Variance of landmarks in digital evaluations: comparison between CT-based and conventional digital lateral cephalometric radiographs. J Orofac Orthop 68:290–298PubMedCrossRef Greiner M, Greiner A, Hirschfelder U (2007) Variance of landmarks in digital evaluations: comparison between CT-based and conventional digital lateral cephalometric radiographs. J Orofac Orthop 68:290–298PubMedCrossRef
10.
Zurück zum Zitat Kumar V, Ludlow JB, Mol A, Cevidanes L (2007) Comparison of conventional and cone beam CT synthesized cephalograms. Dentomaxillofac Radiol 36:263–269PubMedCrossRef Kumar V, Ludlow JB, Mol A, Cevidanes L (2007) Comparison of conventional and cone beam CT synthesized cephalograms. Dentomaxillofac Radiol 36:263–269PubMedCrossRef
11.
Zurück zum Zitat Moshiri M, Scarfe WC, Hilgers ML, Scheetz JP, Silveira AM, Farman AG (2007) Accuracy of linear measurements from imaging plate and lateral cephalometric images derived from cone-beam computed tomography. Am J Orthod Dentofacial Orthop 132:550–560PubMedCrossRef Moshiri M, Scarfe WC, Hilgers ML, Scheetz JP, Silveira AM, Farman AG (2007) Accuracy of linear measurements from imaging plate and lateral cephalometric images derived from cone-beam computed tomography. Am J Orthod Dentofacial Orthop 132:550–560PubMedCrossRef
12.
Zurück zum Zitat Van Vlijmen OJC, Bergé SJ, Bronkhorst EM, Swennen GRJ, Katsaros C, Kuijpers-Jagtman AM (2009) Comparison of cephalometric radiographs obtained from cone-beam computed tomography scans and conventional radiographs. J Oral Maxillofac Surg 67:92–97PubMedCrossRef Van Vlijmen OJC, Bergé SJ, Bronkhorst EM, Swennen GRJ, Katsaros C, Kuijpers-Jagtman AM (2009) Comparison of cephalometric radiographs obtained from cone-beam computed tomography scans and conventional radiographs. J Oral Maxillofac Surg 67:92–97PubMedCrossRef
13.
Zurück zum Zitat Cattaneo PM, Bloch CB, Calmar D, Hjortshoj M, Melsen B (2008) Comparison between conventional and cone-beam computed tomography-generated cephalograms. Am J Orthod Dentofacial Orthop 134:798–802PubMedCrossRef Cattaneo PM, Bloch CB, Calmar D, Hjortshoj M, Melsen B (2008) Comparison between conventional and cone-beam computed tomography-generated cephalograms. Am J Orthod Dentofacial Orthop 134:798–802PubMedCrossRef
14.
Zurück zum Zitat van Vlijmen OJ, Bergé SJ, Bronkhorst EM, Swennen GR, Katsaros C, Kuijpers-Jagtman AM (2009) A comparison of frontal radiographs obtained from cone beam CT scans and conventional frontal radiographs of human skulls. Int J Oral Maxillofac Surg 38:773–778PubMedCrossRef van Vlijmen OJ, Bergé SJ, Bronkhorst EM, Swennen GR, Katsaros C, Kuijpers-Jagtman AM (2009) A comparison of frontal radiographs obtained from cone beam CT scans and conventional frontal radiographs of human skulls. Int J Oral Maxillofac Surg 38:773–778PubMedCrossRef
15.
Zurück zum Zitat van Vlijmen OJ, Maal TJ, Bergé SJ, Bronkhorst EM, Katsaros C, Kuijpers-Jagtman AM (2009) A comparison between two-dimensional and three-dimensional cephalometry on frontal radiographs and on cone beam computed tomography scans of human skulls. Eur J Oral Sci 117:300–305PubMedCrossRef van Vlijmen OJ, Maal TJ, Bergé SJ, Bronkhorst EM, Katsaros C, Kuijpers-Jagtman AM (2009) A comparison between two-dimensional and three-dimensional cephalometry on frontal radiographs and on cone beam computed tomography scans of human skulls. Eur J Oral Sci 117:300–305PubMedCrossRef
16.
Zurück zum Zitat van Vlijmen OJ, Maal TJ, Bergé SJ, Bronkhorst EM, Katsaros C, Kuijpers-Jagtman AM (2010) A comparison between 2D and 3D cephalometry on CBCT scans of human skulls. Int J Oral Maxillofac Surg 39:156–160PubMedCrossRef van Vlijmen OJ, Maal TJ, Bergé SJ, Bronkhorst EM, Katsaros C, Kuijpers-Jagtman AM (2010) A comparison between 2D and 3D cephalometry on CBCT scans of human skulls. Int J Oral Maxillofac Surg 39:156–160PubMedCrossRef
17.
Zurück zum Zitat Houston WJ (1983) The analysis of errors in orthodontic measurements. Am J Orthod 83:382–390PubMedCrossRef Houston WJ (1983) The analysis of errors in orthodontic measurements. Am J Orthod 83:382–390PubMedCrossRef
18.
Zurück zum Zitat Grauer D, Cevidanes LS, Styner MA, Heulfe I, Harmon ET, Zhu H, Proffit WR (2010) Accuracy and landmark error calculation using cone-beam computed tomography-generated cephalograms. Angle Orthod 80:286–294PubMedCrossRef Grauer D, Cevidanes LS, Styner MA, Heulfe I, Harmon ET, Zhu H, Proffit WR (2010) Accuracy and landmark error calculation using cone-beam computed tomography-generated cephalograms. Angle Orthod 80:286–294PubMedCrossRef
19.
Zurück zum Zitat Lou L, Lagravere MO, Compton S, Major PW, Flores-Mir C (2007) Accuracy of measurements and reliability of landmark identification with computed tomography (CT) techniques in the maxillofacial area: a systematic review. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 104:402–411PubMedCrossRef Lou L, Lagravere MO, Compton S, Major PW, Flores-Mir C (2007) Accuracy of measurements and reliability of landmark identification with computed tomography (CT) techniques in the maxillofacial area: a systematic review. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 104:402–411PubMedCrossRef
20.
Zurück zum Zitat Muramatsu A, Nawa H, Kimura M, Yoshida K, Maeda M, Katsumata A, Ariji E, Goto S (2008) Reproducibility of maxillofacial anatomic landmarks on 3-dimensional computed tomographic images determined with the 95% confidence ellipse method. Angle Orthod 78:396–402PubMedCrossRef Muramatsu A, Nawa H, Kimura M, Yoshida K, Maeda M, Katsumata A, Ariji E, Goto S (2008) Reproducibility of maxillofacial anatomic landmarks on 3-dimensional computed tomographic images determined with the 95% confidence ellipse method. Angle Orthod 78:396–402PubMedCrossRef
Metadaten
Titel
Measurements on 3D models of human skulls derived from two different cone beam CT scanners
verfasst von
Olivier J. C. van Vlijmen
Frits A. Rangel
Stefaan J. Bergé
Ewald M. Bronkhorst
Alfred G. Becking
Anne Marie Kuijpers-Jagtman
Publikationsdatum
01.10.2011
Verlag
Springer-Verlag
Erschienen in
Clinical Oral Investigations / Ausgabe 5/2011
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-010-0440-8

Weitere Artikel der Ausgabe 5/2011

Clinical Oral Investigations 5/2011 Zur Ausgabe

Parodontalbehandlung verbessert Prognose bei Katheterablation

19.04.2024 Vorhofflimmern Nachrichten

Werden Personen mit Vorhofflimmern in der Blanking-Periode nach einer Katheterablation gegen eine bestehende Parodontitis behandelt, verbessert dies die Erfolgsaussichten. Dafür sprechen die Resultate einer prospektiven Untersuchung.

Invasive Zahnbehandlung: Wann eine Antibiotikaprophylaxe vor infektiöser Endokarditis schützt

11.04.2024 Endokarditis Nachrichten

Bei welchen Personen eine Antibiotikaprophylaxe zur Prävention einer infektiösen Endokarditis nach invasiven zahnärztlichen Eingriffen sinnvoll ist, wird diskutiert. Neue Daten stehen im Einklang mit den europäischen Leitlinienempfehlungen.

Zell-Organisatoren unter Druck: Mechanismen des embryonalen Zahnwachstums aufgedeckt

08.04.2024 Zahnmedizin Nachrichten

Der Aufbau von Geweben und Organen während der Embryonalentwicklung wird von den Zellen bemerkenswert choreografiert. Für diesen Prozess braucht es spezielle sogenannte „Organisatoren“. In einer aktuellen Veröffentlichung im Fachjournal Nature Cell Biology berichten Forschende durch welchen Vorgang diese Organisatoren im Gewebe entstehen und wie sie dann die Bildung von Zähnen orchestrieren.

Die Oralprophylaxe & Kinderzahnheilkunde umbenannt

11.03.2024 Kinderzahnmedizin Nachrichten

Infolge der Umbenennung der Deutschen Gesellschaft für Kinderzahnheilkunde in Deutsche Gesellschaft für Kinderzahnmedizin (DGKiZ) wird deren Mitgliederzeitschrift Oralprophylaxe & Kinderzahnheilkunde in Oralprophylaxe & Kinderzahnmedizin umbenannt. Aus diesem Grunde trägt die erste Ausgabe in 2024 erstmalig den neuen Titel.

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.