In vitro comparison of mechanical properties and degree of cure of bulk fill composites

verfasst von: Pascal Czasch, Nicoleta Ilie

Erschienen in: Clinical Oral Investigations | Ausgabe 1/2013

Einloggen, um Zugang zu erhalten

Abstract

Objectives

The aim of our study was to measure and compare degree of conversion (DC) as well as micro- (indentation modulus, E; Vickers hardness, HV) and macromechanical properties (flexural strength, σ; flexural modulus, E flexural) of two recently launched bulk fill resin-based composites (RBCs): Surefil® SDR™ flow (SF) and Venus® bulk fill (VB).

Materials and methods

DC (n = 6) was investigated by Fourier transform infrared spectroscopy (FTIR) in clinical relevant filling depths (0.1, 2, and 4 mm; 6 mm bulk, 6 mm incremental) and irradiation times (10, 20, 40 s). Micro- (n = 6) and macromechanical (n = 20) properties were measured by an automatic microhardness indenter and a three-point bending test device after storing the specimens in distilled water for 24 h at 37°C. Furthermore, on the 6-mm bulk samples, the depth of cure was determined. A field emission scanning electron microscope was used to assess filler size. Results were evaluated using one-way analysis of variance, Tukey’s honest significance test post hoc test, a multivariate analysis (α = 0.05) and an independent t test. Weibull analysis was used to assess σ.

Results

VB showed, in all depth, significant higher DC (VB, 62.4–67.4 %; SF, 57.1–61.9 %), but significant lower macro- (VB, E flexural = 3.6 GPa; σ = 122.7 MPa; SF, E flexural = 5.0 GPa; σ = 131.8 MPa) and micromechanical properties (VB, E = 7.3–8.8 GPa, HV = 40.7–46.5 N/mm²; SF, E = 10.6–12.2 GPa, HV = 55.1–61.1 N/mm²). Both RBCs showed high reliability (VB, m = 21.6; SF, m = 26.7) and a depth of cure of at least 6 mm at all polymerization times. The factor “RBC” showed the strongest influence on the measured properties (η 2 = 0.35–0.80) followed by “measuring depth” (η 2 = 0.10–0.46) and “polymerization time” (η 2 = 0.03–0.12).

Conclusions

Significant differences between both RBCs were found for DC, E, σ, and E flexural at all irradiation times and measuring depths.

Clinical relevance

Curing the RBCs in 4-mm bulks for 20 s can be recommended.
Literatur
3.
Zurück zum Zitat Chen HY, Manhart J, Hickel R, Kunzelmann KH (2001) Polymerization contraction stress in light-cured packable composite resins. Dent Mater 17:253–259PubMedCrossRef Chen HY, Manhart J, Hickel R, Kunzelmann KH (2001) Polymerization contraction stress in light-cured packable composite resins. Dent Mater 17:253–259PubMedCrossRef
4.
Zurück zum Zitat Davidson CL, de Gee AJ, Feilzer A (1984) The competition between the composite–dentin bond strength and the polymerization contraction stress. J Dent Res 63:1396–1399PubMedCrossRef Davidson CL, de Gee AJ, Feilzer A (1984) The competition between the composite–dentin bond strength and the polymerization contraction stress. J Dent Res 63:1396–1399PubMedCrossRef
5.
Zurück zum Zitat Leinfelder KF (1995) Posterior composite resins: the materials and their clinical performance. J Am Dent Assoc 126(5):663–672PubMed Leinfelder KF (1995) Posterior composite resins: the materials and their clinical performance. J Am Dent Assoc 126(5):663–672PubMed
6.
Zurück zum Zitat Carvalho RM, Pereira JC, Yoshiyama M, Pashley DH (1996) A review of polymerization contraction: the influence of stress development versus stress relief. Oper Dent 21:17–24PubMed Carvalho RM, Pereira JC, Yoshiyama M, Pashley DH (1996) A review of polymerization contraction: the influence of stress development versus stress relief. Oper Dent 21:17–24PubMed
7.
Zurück zum Zitat McCullock AJ, Smith BG (1986) In vitro studies of cusp reinforcement with adhesive restorative material. Br Dent J 161:450–452PubMedCrossRef McCullock AJ, Smith BG (1986) In vitro studies of cusp reinforcement with adhesive restorative material. Br Dent J 161:450–452PubMedCrossRef
8.
Zurück zum Zitat Alomari QD, Reinhardt JW, Boyer DB (2001) Effect of liners on cusp deflection and gap formation in composite restorations. Oper Dent 26:406–411PubMed Alomari QD, Reinhardt JW, Boyer DB (2001) Effect of liners on cusp deflection and gap formation in composite restorations. Oper Dent 26:406–411PubMed
10.
Zurück zum Zitat Burgess J, Cakir D (2010) Comparative properties of low-shrinkage composite resins. Compend Contin Educ Dent 31(2):10–15PubMed Burgess J, Cakir D (2010) Comparative properties of low-shrinkage composite resins. Compend Contin Educ Dent 31(2):10–15PubMed
16.
Zurück zum Zitat Moore BK, Platt JA, Borges G, Chu TM, Katsilieri I (2008) Depth of cure of dental resin composites: ISO 4049 depth and microhardness of types of materials and shades. Oper Dent 33:408–412PubMedCrossRef Moore BK, Platt JA, Borges G, Chu TM, Katsilieri I (2008) Depth of cure of dental resin composites: ISO 4049 depth and microhardness of types of materials and shades. Oper Dent 33:408–412PubMedCrossRef
17.
Zurück zum Zitat Hansen EK, Asmussen E (1997) Visible-light curing units: correlation between depth of cure and distance between exit window and resin surface. Acta Odontol Scand 55:162–166PubMedCrossRef Hansen EK, Asmussen E (1997) Visible-light curing units: correlation between depth of cure and distance between exit window and resin surface. Acta Odontol Scand 55:162–166PubMedCrossRef
18.
Zurück zum Zitat Pires JA, Cvitko E, Denehy GE, Swift EJ Jr (1993) Effects of curing tip distance on light intensity and composite resin microhardness. Quintessence Int 24:517–521PubMed Pires JA, Cvitko E, Denehy GE, Swift EJ Jr (1993) Effects of curing tip distance on light intensity and composite resin microhardness. Quintessence Int 24:517–521PubMed
19.
Zurück zum Zitat Price RB, Derand T, Sedarous M, Andreou P, Loney RW (2000) Effect of distance on the power density from two light guides. J Esthet Dent 12:320–327PubMedCrossRef Price RB, Derand T, Sedarous M, Andreou P, Loney RW (2000) Effect of distance on the power density from two light guides. J Esthet Dent 12:320–327PubMedCrossRef
20.
Zurück zum Zitat Ernst CP, Meyer GR, Muller J, Stender E, Ahlers MO, Willershausern B (2004) Depth of cure of LED vs QTH light-curing devices at a distance of 7 mm. J Adhes Dent 6:141–150PubMed Ernst CP, Meyer GR, Muller J, Stender E, Ahlers MO, Willershausern B (2004) Depth of cure of LED vs QTH light-curing devices at a distance of 7 mm. J Adhes Dent 6:141–150PubMed
23.
Zurück zum Zitat Sideridou I, Tserki V, Papanastasiou G (2002) Effect of chemical structure on degree of conversion in light-cured dimethacrylate-based dental resins. Biomaterials 23:1819–1829PubMedCrossRef Sideridou I, Tserki V, Papanastasiou G (2002) Effect of chemical structure on degree of conversion in light-cured dimethacrylate-based dental resins. Biomaterials 23:1819–1829PubMedCrossRef
26.
Zurück zum Zitat Buonocore MG (1955) A simple method of increasing the adhesion of acrylic filling materials to enamel surfaces. J Dent Res 34:849–853PubMedCrossRef Buonocore MG (1955) A simple method of increasing the adhesion of acrylic filling materials to enamel surfaces. J Dent Res 34:849–853PubMedCrossRef
29.
Zurück zum Zitat Asmussen E (1983) Factors affecting the color stability of restorative resins. Acta Odontol Scand 41:11–18PubMedCrossRef Asmussen E (1983) Factors affecting the color stability of restorative resins. Acta Odontol Scand 41:11–18PubMedCrossRef
32.
33.
Zurück zum Zitat Scougall-Vilchis RJ, Hotta Y, Hotta M, Idono T, Yamamoto K (2009) Examination of composite resins with electron microscopy, microhardness tester and energy dispersive X-ray microanalyzer. Dent Mater J 28:102–112PubMedCrossRef Scougall-Vilchis RJ, Hotta Y, Hotta M, Idono T, Yamamoto K (2009) Examination of composite resins with electron microscopy, microhardness tester and energy dispersive X-ray microanalyzer. Dent Mater J 28:102–112PubMedCrossRef
38.
Zurück zum Zitat Kim KH, Ong JL, Okuno O (2002) The effect of filler loading and morphology on the mechanical properties of contemporary composites. J Prosthet Dent 87:642–649PubMedCrossRef Kim KH, Ong JL, Okuno O (2002) The effect of filler loading and morphology on the mechanical properties of contemporary composites. J Prosthet Dent 87:642–649PubMedCrossRef
39.
Zurück zum Zitat Manhart J, Kunzelmann KH, Chen HY, Hickel R (2000) Mechanical properties and wear behavior of light-cured packable composite resins. Dent Mater 16:33–40PubMedCrossRef Manhart J, Kunzelmann KH, Chen HY, Hickel R (2000) Mechanical properties and wear behavior of light-cured packable composite resins. Dent Mater 16:33–40PubMedCrossRef
40.
Zurück zum Zitat Frauscher KE, Ilie N (2011) Depth of cure and mechanical properties of nano-hybrid resin-based composites with novel and conventional matrix formulation. Clin Oral Investig. doi:10.1007/s00784-011-0647-3 Frauscher KE, Ilie N (2011) Depth of cure and mechanical properties of nano-hybrid resin-based composites with novel and conventional matrix formulation. Clin Oral Investig. doi:10.​1007/​s00784-011-0647-3
41.
Zurück zum Zitat Li Y, Swartz ML, Phillips RW, Moore BK, Roberts TA (1985) Effect of filler content and size on properties of composites. J Dent Res 64:1396–1401PubMedCrossRef Li Y, Swartz ML, Phillips RW, Moore BK, Roberts TA (1985) Effect of filler content and size on properties of composites. J Dent Res 64:1396–1401PubMedCrossRef
42.
Zurück zum Zitat Pilo R, Cardash HS (1992) Post-irradiation polymerization of different anterior and posterior visible light-activated resin composites. Dent Mater 8:299–304PubMedCrossRef Pilo R, Cardash HS (1992) Post-irradiation polymerization of different anterior and posterior visible light-activated resin composites. Dent Mater 8:299–304PubMedCrossRef
43.
Zurück zum Zitat Hansen EK, Asmussen E (1993) Correlation between depth of cure and surface hardness of a light-activated resin. Scand J Dent Res 101:62–64PubMed Hansen EK, Asmussen E (1993) Correlation between depth of cure and surface hardness of a light-activated resin. Scand J Dent Res 101:62–64PubMed
44.
Zurück zum Zitat Akram S, Ali Abidi SY, Ahmed S, Meo AA, Fazal-Ur-Rehman Q (2011) Effect of different irradiation times on microhardness and depth of cure of a nanocomposite resin. J Coll Phys Surg Pak 21:411–414. doi:07.2011/jcpsp.411414 Akram S, Ali Abidi SY, Ahmed S, Meo AA, Fazal-Ur-Rehman Q (2011) Effect of different irradiation times on microhardness and depth of cure of a nanocomposite resin. J Coll Phys Surg Pak 21:411–414. doi:07.​2011/​jcpsp.​411414
46.
Zurück zum Zitat Versluis A, Tantbirojn D, Douglas WH (1998) Do dental composites always shrink toward the light? J Dent Res 77:1435–1445PubMedCrossRef Versluis A, Tantbirojn D, Douglas WH (1998) Do dental composites always shrink toward the light? J Dent Res 77:1435–1445PubMedCrossRef
49.
Zurück zum Zitat Tjandrawinata R, Irie M, Suzuki K (2005) Flexural properties of eight flowable light-cured restorative materials, in immediate vs 24-hour water storage. Oper Dent 30:239–249PubMed Tjandrawinata R, Irie M, Suzuki K (2005) Flexural properties of eight flowable light-cured restorative materials, in immediate vs 24-hour water storage. Oper Dent 30:239–249PubMed
Metadaten
Titel
In vitro comparison of mechanical properties and degree of cure of bulk fill composites
verfasst von
Pascal Czasch
Nicoleta Ilie
Publikationsdatum
01.01.2013
Verlag
Springer-Verlag
Erschienen in
Clinical Oral Investigations / Ausgabe 1/2013
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-012-0702-8

Weitere Artikel der Ausgabe 1/2013

Clinical Oral Investigations 1/2013 Zur Ausgabe

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.