Skip to main content
Erschienen in: Lasers in Medical Science 2/2016

01.02.2016 | Original Article

High versus moderate energy use of bipolar fractional radiofrequency in the treatment of acne scars: a split-face double-blinded randomized control trial pilot study

verfasst von: Weeranut Phothong, Rungsima Wanitphakdeedecha, Angkana Sathaworawong, Woraphong Manuskiatti

Erschienen in: Lasers in Medical Science | Ausgabe 2/2016

Einloggen, um Zugang zu erhalten

Abstract

Bipolar fractional radiofrequency (FRF) device was firstly FDA-approved for treating atrophic acne scar in 2008 through the process of dermal coagulation and minimal epidermal ablation. The average energy at 60 mJ/pin was widely used to treat atrophic acne scars. However, the higher energy was delivered, the deeper ablation and coagulation were found. At present, the new generation of a device with bipolar FRF technology with electrode-pin tip was developed to maximize ability to deliver energy up to 100 mJ/pin. The objective of the study was to explore and compare the efficacy of utilizing high energy (100 mJ/pin) and moderate energy (60 mJ/pin) of bipolar fractional radiofrequency in treatment of atrophic acne scar in Asians. This is a split-face, double-blinded, randomized control trial, pilot study by using parallel group design technique. Thirty healthy subjects with Fitzpatrick skin phototype III-IV diagnosed as atrophic acne scares were enrolled. All subjects received four monthly sessions of bipolar FRF treatment. Left and right facial sides of individual patients were randomly assigned for different energy (high energy at 100 mJ/pin versus moderate energy at 60 mJ/pin). Acne scars improvement was blinded graded by dermatologist using global acne scarring score (GASS) which was subjectively evaluated at baseline, 1-, 3-, and 6-month follow-up. Objective scar analysis was also done using UVA-light video camera to measure scar volume, skin smoothness, and wrinkle at baseline, 3-, and 6-month follow-up after the last treatment. Side effects including pain, erythema, swelling, and crusting were also recorded. Thirty subjects completed the study with full 4-treatment course. The mean GASS of high energy side and moderate energy side was significantly reduced at 1-, 3-, and 6-month follow-up visits. At 1 month follow-visit, high energy side demonstrated significant improvement compared with moderate energy side (p = 0.03). Postinflammatory hyperpigmentation (PIH) developed in 21/120 sessions in high energy side (17.5 %) and 16/120 sessions in moderate energy side (13.3 %). Pain score and the duration of erythema after treatments were significant higher on the side that was treated with high energy. Bipolar FRF device was safe and effective in the treatment of atrophic acne scars in Asians. High energy setting demonstrated significant higher efficacy at 1 month follow-visit. However, the efficacy of both energy settings was comparable at 3- and 6-month follow-up. In addition, side effects were significantly more intense on the side treated with high energy.
Literatur
1.
Zurück zum Zitat Lee WJ, Jung HJ, Lim HJ, Jang YH, Lee SJ, Kim DW (2013) Serial sections of atrophic acne scars help in the interpretation of microscopic findings and the selection of good therapeutic modalities. J Eur Acad Dermatol Venereol 27(5):643–6CrossRefPubMed Lee WJ, Jung HJ, Lim HJ, Jang YH, Lee SJ, Kim DW (2013) Serial sections of atrophic acne scars help in the interpretation of microscopic findings and the selection of good therapeutic modalities. J Eur Acad Dermatol Venereol 27(5):643–6CrossRefPubMed
2.
Zurück zum Zitat Zhu X, Zhuo S, Zheng L, Jiang X, Chen J, Lin B (2011) Quantification of scar margin in keloid different from atrophic scar by multiphoton microscopic imaging. Scanning 33(4):195–200PubMed Zhu X, Zhuo S, Zheng L, Jiang X, Chen J, Lin B (2011) Quantification of scar margin in keloid different from atrophic scar by multiphoton microscopic imaging. Scanning 33(4):195–200PubMed
3.
Zurück zum Zitat Zelickson BD, Kist D, Bernstein E, Brown DB, Ksenzenko S, Burns J et al (2004) Histological and ultrastructural evaluation of the effects of a radiofrequency-based nonablative dermal remodeling device: a pilot study. Arch Dermatol 140(2):204–9CrossRefPubMed Zelickson BD, Kist D, Bernstein E, Brown DB, Ksenzenko S, Burns J et al (2004) Histological and ultrastructural evaluation of the effects of a radiofrequency-based nonablative dermal remodeling device: a pilot study. Arch Dermatol 140(2):204–9CrossRefPubMed
4.
Zurück zum Zitat Manuskiatti W, Triwongwaranat D, Varothai S, Eimpunth S, Wanitphakdeedecha R (2010) Efficacy and safety of a carbon-dioxide ablative fractional resurfacing device for treatment of atrophic acne scars in Asians. J Am Acad Dermatol 63(2):274–83CrossRefPubMed Manuskiatti W, Triwongwaranat D, Varothai S, Eimpunth S, Wanitphakdeedecha R (2010) Efficacy and safety of a carbon-dioxide ablative fractional resurfacing device for treatment of atrophic acne scars in Asians. J Am Acad Dermatol 63(2):274–83CrossRefPubMed
5.
Zurück zum Zitat Lee SJ, Kang JM, Chung WS, Kim YK, Kim HS (2014) Ablative non-fractional lasers for atrophic facial acne scars: a new modality of erbium:YAG laser resurfacing in Asians. Lasers Med Sci 29(2):615–9CrossRefPubMed Lee SJ, Kang JM, Chung WS, Kim YK, Kim HS (2014) Ablative non-fractional lasers for atrophic facial acne scars: a new modality of erbium:YAG laser resurfacing in Asians. Lasers Med Sci 29(2):615–9CrossRefPubMed
6.
Zurück zum Zitat Jeong JT, Park JH, Kye YC (2003) Resurfacing of pitted facial acne scars using Er:YAG laser with ablation and coagulation mode. Aesthetic Plast Surg 27(2):130–4CrossRefPubMed Jeong JT, Park JH, Kye YC (2003) Resurfacing of pitted facial acne scars using Er:YAG laser with ablation and coagulation mode. Aesthetic Plast Surg 27(2):130–4CrossRefPubMed
7.
Zurück zum Zitat Mahmoud BH, Srivastava D, Janiga JJ, Yang JJ, Lim HW, Ozog DM (2010) Safety and efficacy of erbium-doped yttrium aluminum garnet fractionated laser for treatment of acne scars in type IV to VI skin. Dermatol Surg 36(5):602–9CrossRefPubMed Mahmoud BH, Srivastava D, Janiga JJ, Yang JJ, Lim HW, Ozog DM (2010) Safety and efficacy of erbium-doped yttrium aluminum garnet fractionated laser for treatment of acne scars in type IV to VI skin. Dermatol Surg 36(5):602–9CrossRefPubMed
8.
Zurück zum Zitat Simmons BJ, Griffith RD, Falto-Aizpurua LA, Nouri K (2014) Use of radiofrequency in cosmetic dermatology: focus on nonablative treatment of acne scars. Clin Cosmet Investig Dermatol 7:335–9CrossRefPubMedCentralPubMed Simmons BJ, Griffith RD, Falto-Aizpurua LA, Nouri K (2014) Use of radiofrequency in cosmetic dermatology: focus on nonablative treatment of acne scars. Clin Cosmet Investig Dermatol 7:335–9CrossRefPubMedCentralPubMed
9.
Zurück zum Zitat Lolis MS, Goldburg DJ (2012) Radiofrequency in cosmetic dermatology: a review. Dermatol Surg 38(11):1765–1776CrossRefPubMed Lolis MS, Goldburg DJ (2012) Radiofrequency in cosmetic dermatology: a review. Dermatol Surg 38(11):1765–1776CrossRefPubMed
10.
Zurück zum Zitat Hruza G, Taub AF, Collier SL, Mulholland SR (2009) Skin rejuvenation and wrinkle reduction using a fractional radiofrequency system. J Drugs Dermatol 83:259–65 Hruza G, Taub AF, Collier SL, Mulholland SR (2009) Skin rejuvenation and wrinkle reduction using a fractional radiofrequency system. J Drugs Dermatol 83:259–65
11.
Zurück zum Zitat Sadick NS, Sato M, Palmisano D, Frank I, Cohen H, Harth Y (2011) In vivo animal histology and clinical evaluation of multisource fractional radiofrequency skin resurfacing (FSR) applicator. J Cosmet Laser Ther 13(5):204–9CrossRefPubMed Sadick NS, Sato M, Palmisano D, Frank I, Cohen H, Harth Y (2011) In vivo animal histology and clinical evaluation of multisource fractional radiofrequency skin resurfacing (FSR) applicator. J Cosmet Laser Ther 13(5):204–9CrossRefPubMed
12.
Zurück zum Zitat Goodman GJ, Baron JA (2006) Postacne scarring—a quantitative global scarring grading system. J Cosmet Dermatol 5(1):48–52CrossRefPubMed Goodman GJ, Baron JA (2006) Postacne scarring—a quantitative global scarring grading system. J Cosmet Dermatol 5(1):48–52CrossRefPubMed
13.
Zurück zum Zitat Krueger N, Sadick NS (2013) New-generation radiofrequency technology. Cutis 91(1):39–46PubMed Krueger N, Sadick NS (2013) New-generation radiofrequency technology. Cutis 91(1):39–46PubMed
14.
Zurück zum Zitat Kim JE, Lee HW, Kim JK, Moon SH, Ko JY, Lee MW et al (2014) Objective evaluation of the clinical efficacy of fractional radiofrequency treatment for acne scars and enlarged pores in Asian skin. Dermatol Surg 40(9):988–95CrossRefPubMed Kim JE, Lee HW, Kim JK, Moon SH, Ko JY, Lee MW et al (2014) Objective evaluation of the clinical efficacy of fractional radiofrequency treatment for acne scars and enlarged pores in Asian skin. Dermatol Surg 40(9):988–95CrossRefPubMed
15.
Zurück zum Zitat Kaminaka C, Uede M, Nakamura Y, Furukawa F, Yamamoto Y (2014) Histological studies of facial acne and atrophic acne scars treated with a bipolar fractional radiofrequency system. J Dermatol 41(5):435–8CrossRefPubMed Kaminaka C, Uede M, Nakamura Y, Furukawa F, Yamamoto Y (2014) Histological studies of facial acne and atrophic acne scars treated with a bipolar fractional radiofrequency system. J Dermatol 41(5):435–8CrossRefPubMed
16.
Zurück zum Zitat Gold MH, Biron JA (2012) Treatment of acne scars by fractional bipolar radiofrequency energy. J Cosmet Laser Ther 14(4):172–8CrossRefPubMed Gold MH, Biron JA (2012) Treatment of acne scars by fractional bipolar radiofrequency energy. J Cosmet Laser Ther 14(4):172–8CrossRefPubMed
17.
Zurück zum Zitat Rongsaard N, Rummaneethorn P (2014) Comparison of a fractional bipolar radiofrequency device and a fractional erbium-doped glass 1,550-nm device for the treatment of atrophic acne scars: a randomized split-face clinical study. Dermatol Surg 40(1):14–21CrossRefPubMed Rongsaard N, Rummaneethorn P (2014) Comparison of a fractional bipolar radiofrequency device and a fractional erbium-doped glass 1,550-nm device for the treatment of atrophic acne scars: a randomized split-face clinical study. Dermatol Surg 40(1):14–21CrossRefPubMed
18.
Zurück zum Zitat Man J, Goldberg DJ (2012) Safety and efficacy of fractional bipolar radiofrequency treatment in Fitzpatrick skin types V-VI. J Cosmet Laser Ther 14(4):179–83CrossRefPubMed Man J, Goldberg DJ (2012) Safety and efficacy of fractional bipolar radiofrequency treatment in Fitzpatrick skin types V-VI. J Cosmet Laser Ther 14(4):179–83CrossRefPubMed
19.
Zurück zum Zitat Manuskiatte W, Iamphonrat T, Wanitphakdeedecha R, Eimpunth S (2013) Comparison of fractional erbium-doped yttrium aluminum garnet and carbon dioxide lasers in resurfacing of atrophic acne scars in Asians. Dermatol Surg 39(1 Pt 1):111–20CrossRef Manuskiatte W, Iamphonrat T, Wanitphakdeedecha R, Eimpunth S (2013) Comparison of fractional erbium-doped yttrium aluminum garnet and carbon dioxide lasers in resurfacing of atrophic acne scars in Asians. Dermatol Surg 39(1 Pt 1):111–20CrossRef
20.
Zurück zum Zitat Vejjabhinanta V, Wanitphakdeedecha R, Limtanyakul P, Manuskiatti W (2014) The efficacy in treatment of facial atrophic acne scars in Asians with a fractional radiofrequency microneedle system. J Eur Acad Dermatol Venereol 28(9):1219–25CrossRefPubMed Vejjabhinanta V, Wanitphakdeedecha R, Limtanyakul P, Manuskiatti W (2014) The efficacy in treatment of facial atrophic acne scars in Asians with a fractional radiofrequency microneedle system. J Eur Acad Dermatol Venereol 28(9):1219–25CrossRefPubMed
21.
Zurück zum Zitat Sussman C, Bates-Jensen BM (2007) Wound healing physiology: acute and chronic. In: Sussman C, Bates-Jensen BM (eds) Wound care. Lippincott Williams and Wilkins, Philadelphia, pp 21–51 Sussman C, Bates-Jensen BM (2007) Wound healing physiology: acute and chronic. In: Sussman C, Bates-Jensen BM (eds) Wound care. Lippincott Williams and Wilkins, Philadelphia, pp 21–51
22.
Zurück zum Zitat Yeung CK, Chan NP, Shek SY, Chan HH (2012) Evaluation of combined fractional radiofrequency and fractional laser treatment for acne scars in Asians. Lasers Surg Med 44(8):622–30CrossRefPubMed Yeung CK, Chan NP, Shek SY, Chan HH (2012) Evaluation of combined fractional radiofrequency and fractional laser treatment for acne scars in Asians. Lasers Surg Med 44(8):622–30CrossRefPubMed
Metadaten
Titel
High versus moderate energy use of bipolar fractional radiofrequency in the treatment of acne scars: a split-face double-blinded randomized control trial pilot study
verfasst von
Weeranut Phothong
Rungsima Wanitphakdeedecha
Angkana Sathaworawong
Woraphong Manuskiatti
Publikationsdatum
01.02.2016
Verlag
Springer London
Erschienen in
Lasers in Medical Science / Ausgabe 2/2016
Print ISSN: 0268-8921
Elektronische ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-015-1850-2