Correlation between resonance frequency, insertion torque and bone-implant contact in self-cutting threaded implants

verfasst von: Yahya Açil, Jan Sievers, Aydin Gülses, Mustafa Ayna, Jörg Wiltfang, Hendrik Terheyden

Erschienen in: Odontology | Ausgabe 3/2017

Einloggen, um Zugang zu erhalten

Abstract

The aim of this study was to evaluate the correlation between resonance frequency analysis (RFA) values and the histomorphometric bone-implant contact (BIC) immediately after insertion of the implant. Additionally, it was examined to define which extent peak insertion torque (PIT) was correlated with the latter measurements. 15 Xive® S plus root from dental implants were inserted in fresh porcine frontal bones. The insertion torque was measured with the Kavo Intrasurg 300 surgical unit. RFA connector was coupled to the implants and the mean value of 20 consecutive RFA measurements was calculated via Osstell® ISQ device. The implants were removed with the adjacent bone with a band saw. The blocks were processed for undecalcified histology. Two perpendicular longitudinal middle sections of the implant were made and stained with toluidine blue and the BIC was assessed by histomorphometry. The correlation coefficient (Spearman) between RFA and BIC was R = 0.579 (p = 0.026, F test). The correlation between PIT and BIC (0.33, p > 0.05) and PIT and RFA (0.153, p > 0.05) was not statistically significant. The present data confirmed a moderate and statistically positive correlation between RFA and BIC. No correlation between BIC and PIT and PIT and RFA was observed. Further studies considering different bone qualities would be beneficial in understanding the relation between RFA and BIC.
Literatur
1.
Zurück zum Zitat Manresa C, Bosch M, Echeverría JJ. The comparison between implant stability quotient and bone-implant contact revisited: an experiment in Beagle dog. Clin Oral Implants Res. 2014;25:1213–21.CrossRefPubMed Manresa C, Bosch M, Echeverría JJ. The comparison between implant stability quotient and bone-implant contact revisited: an experiment in Beagle dog. Clin Oral Implants Res. 2014;25:1213–21.CrossRefPubMed
2.
Zurück zum Zitat Quesada-García MP, Prados-Sánchez E, Olmedo-Gaya MV, Muñoz-Soto E, González-Rodríguez MP, Valllecillo-Capilla M. Measurement of dental implant stability by resonance frequency analysis: a review of the literature. Med Oral Patol Oral Cir Bucal. 2009;14:538–46.CrossRef Quesada-García MP, Prados-Sánchez E, Olmedo-Gaya MV, Muñoz-Soto E, González-Rodríguez MP, Valllecillo-Capilla M. Measurement of dental implant stability by resonance frequency analysis: a review of the literature. Med Oral Patol Oral Cir Bucal. 2009;14:538–46.CrossRef
3.
Zurück zum Zitat Akça K, Kökat AM, Cömert A, Akkocaoğlu M, Tekdemir I, Cehreli MC. Torque-fitting and resonance frequency analyses of implants in conventional sockets versus controlled bone defects in vitro. Int J Oral Maxillofac Surg. 2010;39:169–73.CrossRefPubMed Akça K, Kökat AM, Cömert A, Akkocaoğlu M, Tekdemir I, Cehreli MC. Torque-fitting and resonance frequency analyses of implants in conventional sockets versus controlled bone defects in vitro. Int J Oral Maxillofac Surg. 2010;39:169–73.CrossRefPubMed
4.
Zurück zum Zitat Ohta K, Takechi M, Minami M, Shigeishi H, Hiraoka M, Nishimura M, Kamata N. Influence of factors related to implant stability detected by wireless resonance frequency analysis device. J Oral Rehabil. 2010;37:131–7.CrossRefPubMed Ohta K, Takechi M, Minami M, Shigeishi H, Hiraoka M, Nishimura M, Kamata N. Influence of factors related to implant stability detected by wireless resonance frequency analysis device. J Oral Rehabil. 2010;37:131–7.CrossRefPubMed
5.
Zurück zum Zitat Turkyilmaz I, Sennerby L, Yilmaz B, Bilecenoglu B, Ozbek EN. Influence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: a human cadaver study. Clin Implant Dent Relat Res. 2009;11:52–8.CrossRefPubMed Turkyilmaz I, Sennerby L, Yilmaz B, Bilecenoglu B, Ozbek EN. Influence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: a human cadaver study. Clin Implant Dent Relat Res. 2009;11:52–8.CrossRefPubMed
6.
Zurück zum Zitat Nkenke E, Hahn M, Weinzierl K, Radespiel-Tröger M, Neukam FW, Engelke K. Implant stability and histomorphometry: a correlation study in human cadavers using stepped cylinder implants. Clin Oral Implants Res. 2003;14:601–9.CrossRefPubMed Nkenke E, Hahn M, Weinzierl K, Radespiel-Tröger M, Neukam FW, Engelke K. Implant stability and histomorphometry: a correlation study in human cadavers using stepped cylinder implants. Clin Oral Implants Res. 2003;14:601–9.CrossRefPubMed
7.
Zurück zum Zitat Schliephake H, Sewing A, Aref A. Resonance frequency measurements of implant stability in the dog mandible: experimental comparison with histomor-phometric data. Int J Oral Maxillofac Surg. 2006;35:941–6.CrossRefPubMed Schliephake H, Sewing A, Aref A. Resonance frequency measurements of implant stability in the dog mandible: experimental comparison with histomor-phometric data. Int J Oral Maxillofac Surg. 2006;35:941–6.CrossRefPubMed
8.
Zurück zum Zitat Donath K, Breuner G. A method for the study of undecalcified bones and teeth with attaced soft tissues: the Säge-Schliff (sawing and grinding) technique. J Oral Pathol. 1982;II:318–26.CrossRef Donath K, Breuner G. A method for the study of undecalcified bones and teeth with attaced soft tissues: the Säge-Schliff (sawing and grinding) technique. J Oral Pathol. 1982;II:318–26.CrossRef
9.
Zurück zum Zitat Kim YS, Lim YJ. Primary stability and self-tapping blades: biomechanical assessment of dental implants in medium-density bone. Clin Oral Implants Res. 2011;22:1179–84.CrossRefPubMed Kim YS, Lim YJ. Primary stability and self-tapping blades: biomechanical assessment of dental implants in medium-density bone. Clin Oral Implants Res. 2011;22:1179–84.CrossRefPubMed
10.
Zurück zum Zitat Kim DR, Lim YJ, Kim MJ, Kwon HB, Kim SH. Self-cutting blades and their influence on primary stability of tapered dental implants in a simulated low-density bone model: a laboratory study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2011;112:573–80.CrossRefPubMed Kim DR, Lim YJ, Kim MJ, Kwon HB, Kim SH. Self-cutting blades and their influence on primary stability of tapered dental implants in a simulated low-density bone model: a laboratory study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2011;112:573–80.CrossRefPubMed
11.
Zurück zum Zitat Chowdary R. Evaluation of a self cutting thread designed and non self cutting threaded implants placed in extraction sites with immediate temporization: a 5-year clinical study in: abstracts of the EAO 23rd Annual Scientific Meeting, September 25–27, 2014, Rome, Italy. Clin Oral Implants Res. 2014;25(Suppl 10):1–694. Chowdary R. Evaluation of a self cutting thread designed and non self cutting threaded implants placed in extraction sites with immediate temporization: a 5-year clinical study in: abstracts of the EAO 23rd Annual Scientific Meeting, September 25–27, 2014, Rome, Italy. Clin Oral Implants Res. 2014;25(Suppl 10):1–694.
12.
Zurück zum Zitat Buser D, Nydegger T, Hirt HP, Cochran DL, Nolte LP. Removal torque values of titanium implants in the maxilla of miniature pigs. Int J Oral Maxillofac Implants. 1998;13:611–9.PubMed Buser D, Nydegger T, Hirt HP, Cochran DL, Nolte LP. Removal torque values of titanium implants in the maxilla of miniature pigs. Int J Oral Maxillofac Implants. 1998;13:611–9.PubMed
13.
Zurück zum Zitat Büchter A, Kleinheinz J, Wiesmann HP, Seper L, Joos U, Meyer U. Peri-implant bone formation around cylindrical and conical implant systems. Mund Kiefer Gesichtschir. 2004;8:282–8.CrossRefPubMed Büchter A, Kleinheinz J, Wiesmann HP, Seper L, Joos U, Meyer U. Peri-implant bone formation around cylindrical and conical implant systems. Mund Kiefer Gesichtschir. 2004;8:282–8.CrossRefPubMed
14.
Zurück zum Zitat Bashutski JD, D’Silva NJ, Wang HL. Implant compression necrosis: current understanding and case report. J Periodontol. 2009;80:700–4.CrossRefPubMed Bashutski JD, D’Silva NJ, Wang HL. Implant compression necrosis: current understanding and case report. J Periodontol. 2009;80:700–4.CrossRefPubMed
15.
Zurück zum Zitat Nevins M, Nevins ML, Schupbach P, Fiorellini J, Lin Z, Kim DM. The impact of bone compression on bone-to-implant contact of an osseointegrated implant: a canine study. Int J Periodontics Restor Dent. 2012;32:637–45. Nevins M, Nevins ML, Schupbach P, Fiorellini J, Lin Z, Kim DM. The impact of bone compression on bone-to-implant contact of an osseointegrated implant: a canine study. Int J Periodontics Restor Dent. 2012;32:637–45.
16.
Zurück zum Zitat Halldin A, Jimbo R, Johansson CB, Wennerberg A, Jacobsson M, Albrektsson T, Hansson S. The effect of static bone strain on implant stability and bone remodeling. Bone. 2011;49(4):783–9.CrossRefPubMed Halldin A, Jimbo R, Johansson CB, Wennerberg A, Jacobsson M, Albrektsson T, Hansson S. The effect of static bone strain on implant stability and bone remodeling. Bone. 2011;49(4):783–9.CrossRefPubMed
17.
Zurück zum Zitat Jimbo R, Tovar N, Marin C, Teixeira HS, Anchieta RB, Silveira LM, Janal MN, Shibli JA, Coelho PG. The impact of a modified cutting flute implant design on osseointegration. Int J Oral Maxillofac Surg. 2014;43:883–8.CrossRefPubMed Jimbo R, Tovar N, Marin C, Teixeira HS, Anchieta RB, Silveira LM, Janal MN, Shibli JA, Coelho PG. The impact of a modified cutting flute implant design on osseointegration. Int J Oral Maxillofac Surg. 2014;43:883–8.CrossRefPubMed
18.
Zurück zum Zitat Dagher M, Mokbel N, Jabbour G, Naaman N. Resonance frequency analysis, insertion torque, and bone to implant contact of 4 implant surfaces: comparison and correlation study in sheep. Implant Dent. 2014;23:672–8.PubMed Dagher M, Mokbel N, Jabbour G, Naaman N. Resonance frequency analysis, insertion torque, and bone to implant contact of 4 implant surfaces: comparison and correlation study in sheep. Implant Dent. 2014;23:672–8.PubMed
19.
Zurück zum Zitat Abrahamsson I, Linder E, Lang NP. Implant stability in relation to osseointe-gration: an experimental study in the Labrador dog. Clin Oral Implants Res. 2009;20:313–8.CrossRefPubMed Abrahamsson I, Linder E, Lang NP. Implant stability in relation to osseointe-gration: an experimental study in the Labrador dog. Clin Oral Implants Res. 2009;20:313–8.CrossRefPubMed
20.
Zurück zum Zitat Ito Y, Sato D, Yoneda S, Ito D, Kondo H, Kasugai S. Relevance of resonance frequency analysis to evaluate dental implant stability: simulation and histo-morphometrical animal experiments. Clin Oral Implants Res. 2007;19:9–14.PubMed Ito Y, Sato D, Yoneda S, Ito D, Kondo H, Kasugai S. Relevance of resonance frequency analysis to evaluate dental implant stability: simulation and histo-morphometrical animal experiments. Clin Oral Implants Res. 2007;19:9–14.PubMed
21.
Zurück zum Zitat Scarano A, Degidi M, Iezzi G, Petrone G, Piattelli A. Correlation between im-plant stability quotient and bone-implant contact: a retrospective histological and histomorphometrical study of seven titanium implants retrieved from humans. Clin Implant Dent Relat Res. 2006;8:218–22.CrossRefPubMed Scarano A, Degidi M, Iezzi G, Petrone G, Piattelli A. Correlation between im-plant stability quotient and bone-implant contact: a retrospective histological and histomorphometrical study of seven titanium implants retrieved from humans. Clin Implant Dent Relat Res. 2006;8:218–22.CrossRefPubMed
22.
Zurück zum Zitat Ottoni JM, Oliveira ZF, Mansini R, Cabral AM. Correlation between placement torque and survival of single-tooth implants. Int J Oral Maxillofac Implants. 2005;20:769–76.PubMed Ottoni JM, Oliveira ZF, Mansini R, Cabral AM. Correlation between placement torque and survival of single-tooth implants. Int J Oral Maxillofac Implants. 2005;20:769–76.PubMed
23.
Zurück zum Zitat Eliyas S, Al-Khayatt AS. No difference between failure rates of early and con-ventionally loaded implants. Evid Based Dent. 2008;9:50.CrossRefPubMed Eliyas S, Al-Khayatt AS. No difference between failure rates of early and con-ventionally loaded implants. Evid Based Dent. 2008;9:50.CrossRefPubMed
24.
Zurück zum Zitat Ersanli S, Karabuda C, Beck F, Leblebicioglu B. Resonance frequency analy-sis of one-stage dental implant stability during the osseointegration period. J Periodontol. 2005;76:1066–71.CrossRefPubMed Ersanli S, Karabuda C, Beck F, Leblebicioglu B. Resonance frequency analy-sis of one-stage dental implant stability during the osseointegration period. J Periodontol. 2005;76:1066–71.CrossRefPubMed
25.
Zurück zum Zitat Esposito M, Grusovin MG, Willings M, Coulthard P, Worthington HV. The effectiveness of immediate, early, and conventional loading of dental implants: a Cochrane systematic review of randomized controlled clinical trials. Int J Oral Maxillofac Implants. 2007;22:893–904.PubMed Esposito M, Grusovin MG, Willings M, Coulthard P, Worthington HV. The effectiveness of immediate, early, and conventional loading of dental implants: a Cochrane systematic review of randomized controlled clinical trials. Int J Oral Maxillofac Implants. 2007;22:893–904.PubMed
26.
Zurück zum Zitat Degidi M, Perrotti V, Strocchi R, Piattelli A, Iezzi G. Is insertion torque corre-lated to bone-implant contact percentage in the early healing period? A histological and histomorphometrical evaluation of 17 human-retrieved dental im-plants. Clin Oral Implants Res. 2009;26:330–5. Degidi M, Perrotti V, Strocchi R, Piattelli A, Iezzi G. Is insertion torque corre-lated to bone-implant contact percentage in the early healing period? A histological and histomorphometrical evaluation of 17 human-retrieved dental im-plants. Clin Oral Implants Res. 2009;26:330–5.
27.
Zurück zum Zitat Tabassum A, Meijer GJ, Wolke JG, Jansen JA. Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study. Clin Oral Implants Res. 2010;21:213–20.CrossRefPubMed Tabassum A, Meijer GJ, Wolke JG, Jansen JA. Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study. Clin Oral Implants Res. 2010;21:213–20.CrossRefPubMed
28.
Zurück zum Zitat Cehreli MC, Kökat AM, Comert A, Akkocaoğlu M, Tekdemir I, Akça K. Implant stability and bone density: assessment of correlation in fresh cadavers using conventional and osteotome implant sockets. Clin Oral Implants Res. 2009;20:1163–9.CrossRefPubMed Cehreli MC, Kökat AM, Comert A, Akkocaoğlu M, Tekdemir I, Akça K. Implant stability and bone density: assessment of correlation in fresh cadavers using conventional and osteotome implant sockets. Clin Oral Implants Res. 2009;20:1163–9.CrossRefPubMed
29.
Zurück zum Zitat Kunnekel AT, Nair KC, Naidu EM, Sivagami G. Validation of resonance frequency analysis by comparing implant stability quotient values with histomorphometric data. J Oral Implantol. 2011;37:301–8.CrossRefPubMed Kunnekel AT, Nair KC, Naidu EM, Sivagami G. Validation of resonance frequency analysis by comparing implant stability quotient values with histomorphometric data. J Oral Implantol. 2011;37:301–8.CrossRefPubMed
30.
Zurück zum Zitat Metzler P, von Wilmowsky C, Stadlinger B, Zemann W, Schlegel KA, Rosiwal S, Rupprecht S. Nano-crystalline diamond-coated titanium dental implants—a histomorphometric study in adult domestic pigs. J Cranio-Maxillofac Surg. 2013;41:532–8.CrossRef Metzler P, von Wilmowsky C, Stadlinger B, Zemann W, Schlegel KA, Rosiwal S, Rupprecht S. Nano-crystalline diamond-coated titanium dental implants—a histomorphometric study in adult domestic pigs. J Cranio-Maxillofac Surg. 2013;41:532–8.CrossRef
31.
Zurück zum Zitat Laiblin C, Jaeschke G. Clinical chemistry examinations of bone and muscle metabolism under stress in the Gottingen miniature pig—an experimental study. Berl Munch Tierarztl Wochenschr. 1979;92:124–8.PubMed Laiblin C, Jaeschke G. Clinical chemistry examinations of bone and muscle metabolism under stress in the Gottingen miniature pig—an experimental study. Berl Munch Tierarztl Wochenschr. 1979;92:124–8.PubMed
Metadaten
Titel
Correlation between resonance frequency, insertion torque and bone-implant contact in self-cutting threaded implants
verfasst von
Yahya Açil
Jan Sievers
Aydin Gülses
Mustafa Ayna
Jörg Wiltfang
Hendrik Terheyden
Publikationsdatum
18.08.2016
Verlag
Springer Japan
Erschienen in
Odontology / Ausgabe 3/2017
Print ISSN: 1618-1247
Elektronische ISSN: 1618-1255
DOI
https://doi.org/10.1007/s10266-016-0265-2

Weitere Artikel der Ausgabe 3/2017

Odontology 3/2017 Zur Ausgabe

Parodontalbehandlung verbessert Prognose bei Katheterablation

19.04.2024 Vorhofflimmern Nachrichten

Werden Personen mit Vorhofflimmern in der Blanking-Periode nach einer Katheterablation gegen eine bestehende Parodontitis behandelt, verbessert dies die Erfolgsaussichten. Dafür sprechen die Resultate einer prospektiven Untersuchung.

Invasive Zahnbehandlung: Wann eine Antibiotikaprophylaxe vor infektiöser Endokarditis schützt

11.04.2024 Endokarditis Nachrichten

Bei welchen Personen eine Antibiotikaprophylaxe zur Prävention einer infektiösen Endokarditis nach invasiven zahnärztlichen Eingriffen sinnvoll ist, wird diskutiert. Neue Daten stehen im Einklang mit den europäischen Leitlinienempfehlungen.

Zell-Organisatoren unter Druck: Mechanismen des embryonalen Zahnwachstums aufgedeckt

08.04.2024 Zahnmedizin Nachrichten

Der Aufbau von Geweben und Organen während der Embryonalentwicklung wird von den Zellen bemerkenswert choreografiert. Für diesen Prozess braucht es spezielle sogenannte „Organisatoren“. In einer aktuellen Veröffentlichung im Fachjournal Nature Cell Biology berichten Forschende durch welchen Vorgang diese Organisatoren im Gewebe entstehen und wie sie dann die Bildung von Zähnen orchestrieren.

Die Oralprophylaxe & Kinderzahnheilkunde umbenannt

11.03.2024 Kinderzahnmedizin Nachrichten

Infolge der Umbenennung der Deutschen Gesellschaft für Kinderzahnheilkunde in Deutsche Gesellschaft für Kinderzahnmedizin (DGKiZ) wird deren Mitgliederzeitschrift Oralprophylaxe & Kinderzahnheilkunde in Oralprophylaxe & Kinderzahnmedizin umbenannt. Aus diesem Grunde trägt die erste Ausgabe in 2024 erstmalig den neuen Titel.

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.