Skip to main content
Erschienen in: The International Journal of Cardiovascular Imaging 8/2012

01.12.2012 | Original Paper

Neointimal tissue characteristics following sirolimus-eluting stent implantation: OCT quantitative tissue property analysis

verfasst von: Jingbo Hou, Haibo Jia, Haixia Liu, Zhigang Han, Shuang Yang, Chenyang Xu, Joseph Schmitt, Shaosong Zhang, Bo Yu, Ik-Kyung Jang

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 8/2012

Einloggen, um Zugang zu erhalten

Abstract

The neointimal tissue characteristics inside sirolimus-eluting stent (SES) were evaluated by optical coherence tomography (OCT) according to follow-up duration. One hundred and thirty-three Optical coherence tomography was performed in 96 patients with 143 SES which were retrospectively included and divided into 2 groups according to follow-up duration: Group 1, <24 months (98 stents in 71 patients); Group 2, >24 months (35 stents in 25 patients). The neointimal tissue coverage pattern and characteristics were studied using a new OCT analysis system which can quantitatively analyze tissue property by measuring attenuation, backscatter and signal intensity in the region of interest. Using these parameters, a multivariable logistic regression model was constructed to divide neointima into homogenous or heterogeneous type. We defined homogeneous nointima as neointimal tissue having uniform optical properties and does not showing focal variations in backscattering pattern and heterogeneous neointima as neointimal tissue with focally changing optical properties and showing various backscattering patterns. The average time between stent implantation and follow-up OCT imaging was 1.2 years in Group 1 and 3.2 years in Group 2. The number of neointima covered cross-sections, neointimal thickness, and neointimal area increased significantly with the length of follow-up duration after SES implantation (P < 0.01). The incidence of heterogeneous neointima was higher in Group 2 than in Group 1 (P < 0.01). Heterogeneous neointima was associated with higher incidence of microvessels (P = 0.0023) and lipid rich plaque (P = 0.0015) compared with homogeneous neointima. The neointimal tissue characteristics may change over time after SES implantation. The incidence of heterogeneous pattern was higher in the SES group with longer follow-up duration. Microvessels and lipid rich plaques were more frequently observed in neointima with heterogeneous pattern. Neointimal heterogeneity could be an important factor for the late stability of SES.
Literatur
1.
Zurück zum Zitat Marzocchi A, Saia F, Piovaccari G, Manari A, Aurier E, Benassi A, Cremonesi A, Percoco G, Varani E, Magnavacchi P, Guastaroba P, Grilli R, Maresta A (2007) Long-term safety and efficacy of drug-eluting stents: two-year results of the REAL (REgistro AngiopLastiche dell’Emilia Romagna) multicenter registry. Circulation 115(25):3181–3188PubMedCrossRef Marzocchi A, Saia F, Piovaccari G, Manari A, Aurier E, Benassi A, Cremonesi A, Percoco G, Varani E, Magnavacchi P, Guastaroba P, Grilli R, Maresta A (2007) Long-term safety and efficacy of drug-eluting stents: two-year results of the REAL (REgistro AngiopLastiche dell’Emilia Romagna) multicenter registry. Circulation 115(25):3181–3188PubMedCrossRef
2.
Zurück zum Zitat Morice MC, Serruys PW, Sousa JE, Fajadet J, Ban Hayashi E, Perin M, Colombo A, Schuler G, Barragan P, Guagliumi G, Molnar F, Falotico R (2002) A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 346(23):1773–1780PubMedCrossRef Morice MC, Serruys PW, Sousa JE, Fajadet J, Ban Hayashi E, Perin M, Colombo A, Schuler G, Barragan P, Guagliumi G, Molnar F, Falotico R (2002) A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 346(23):1773–1780PubMedCrossRef
3.
Zurück zum Zitat Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O’Shaughnessy C, Caputo RP, Kereiakes DJ, Williams DO, Teirstein PS, Jaeger JL, Kuntz RE (2003) Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 349(14):1315–1323PubMedCrossRef Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O’Shaughnessy C, Caputo RP, Kereiakes DJ, Williams DO, Teirstein PS, Jaeger JL, Kuntz RE (2003) Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 349(14):1315–1323PubMedCrossRef
4.
Zurück zum Zitat Iakovou I, Schmidt T, Bonizzoni E, Ge L, Sangiorgi GM, Stankovic G, Airoldi F, Chieffo A, Montorfano M, Carlino M, Michev I, Corvaja N, Briguori C, Gerckens U, Grube E, Colombo A (2005) Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA 293(17):2126–2130PubMedCrossRef Iakovou I, Schmidt T, Bonizzoni E, Ge L, Sangiorgi GM, Stankovic G, Airoldi F, Chieffo A, Montorfano M, Carlino M, Michev I, Corvaja N, Briguori C, Gerckens U, Grube E, Colombo A (2005) Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA 293(17):2126–2130PubMedCrossRef
5.
Zurück zum Zitat Takano M, Mizuno K (2006) Late coronary thrombosis in a sirolimus-eluting stent due to the lack of neointimal coverage. Eur Heart J 27(10):1133PubMedCrossRef Takano M, Mizuno K (2006) Late coronary thrombosis in a sirolimus-eluting stent due to the lack of neointimal coverage. Eur Heart J 27(10):1133PubMedCrossRef
6.
Zurück zum Zitat Habara M, Terashima M, Suzuki T (2009) Detection of atherosclerotic progression with rupture of degenerated in-stent intima five years after bare-metal stent implantation using optical coherence tomography. J Invasive Cardiol 21(10):552–553PubMed Habara M, Terashima M, Suzuki T (2009) Detection of atherosclerotic progression with rupture of degenerated in-stent intima five years after bare-metal stent implantation using optical coherence tomography. J Invasive Cardiol 21(10):552–553PubMed
7.
Zurück zum Zitat Chamie D, Abizaid A, Costa JR Jr, Feres F, Almiro da Silva JF, Mattos LA, Staico R, Costa RA, Tanajura LF, Sousa AG, Sousa JE (2011) Serial angiographic and intravascular ultrasound evaluation to interrogate the presence of late “catch-up” phenomenon after cypher(R) sirolimus-eluting stent implantation. Int J Cardiovasc Imaging 27(6):867–874PubMedCrossRef Chamie D, Abizaid A, Costa JR Jr, Feres F, Almiro da Silva JF, Mattos LA, Staico R, Costa RA, Tanajura LF, Sousa AG, Sousa JE (2011) Serial angiographic and intravascular ultrasound evaluation to interrogate the presence of late “catch-up” phenomenon after cypher(R) sirolimus-eluting stent implantation. Int J Cardiovasc Imaging 27(6):867–874PubMedCrossRef
8.
Zurück zum Zitat Welt FG, Rogers C (2002) Inflammation and restenosis in the stent era. Arterioscler Thromb Vasc Biol 22(11):1769–1776PubMedCrossRef Welt FG, Rogers C (2002) Inflammation and restenosis in the stent era. Arterioscler Thromb Vasc Biol 22(11):1769–1776PubMedCrossRef
9.
Zurück zum Zitat Welt FG, Tso C, Edelman ER, Kjelsberg MA, Paolini JF, Seifert P, Rogers C (2003) Leukocyte recruitment and expression of chemokines following different forms of vascular injury. Vasc Med 8(1):1–7PubMedCrossRef Welt FG, Tso C, Edelman ER, Kjelsberg MA, Paolini JF, Seifert P, Rogers C (2003) Leukocyte recruitment and expression of chemokines following different forms of vascular injury. Vasc Med 8(1):1–7PubMedCrossRef
10.
Zurück zum Zitat Zimmermann A, Pollinger B, Rieber J, Konig A, Erhard I, Krotz F, Sohn HY, Kantlehner R, Haimerl W, Duhmke E, Leibig M, Theisen K, Klauss V, Schiele TM (2005) Early time course of neointima formation and vascular remodelling following percutaneous coronary intervention and vascular brachytherapy of in-stent restenotic lesions as assessed by intravascular ultrasound analysis. Z Kardiol 94(4):239–246PubMedCrossRef Zimmermann A, Pollinger B, Rieber J, Konig A, Erhard I, Krotz F, Sohn HY, Kantlehner R, Haimerl W, Duhmke E, Leibig M, Theisen K, Klauss V, Schiele TM (2005) Early time course of neointima formation and vascular remodelling following percutaneous coronary intervention and vascular brachytherapy of in-stent restenotic lesions as assessed by intravascular ultrasound analysis. Z Kardiol 94(4):239–246PubMedCrossRef
11.
Zurück zum Zitat Gonzalo N, Serruys PW, Okamura T, van Beusekom HM, Garcia–Garcia HM, van Soest G, van der Giessen W, Regar E (2009) Optical coherence tomography patterns of stent restenosis. Am Heart J 158(2):284–293PubMedCrossRef Gonzalo N, Serruys PW, Okamura T, van Beusekom HM, Garcia–Garcia HM, van Soest G, van der Giessen W, Regar E (2009) Optical coherence tomography patterns of stent restenosis. Am Heart J 158(2):284–293PubMedCrossRef
12.
Zurück zum Zitat Gonzalo N, Barlis P, Serruys PW, Garcia-Garcia HM, Onuma Y, Ligthart J, Regar E (2009) Incomplete stent apposition and delayed tissue coverage are more frequent in drug-eluting stents implanted during primary percutaneous coronary intervention for ST-segment elevation myocardial infarction than in drug-eluting stents implanted for stable/unstable angina: insights from optical coherence tomography. JACC Cardiovasc Interv 2(5):445–452PubMedCrossRef Gonzalo N, Barlis P, Serruys PW, Garcia-Garcia HM, Onuma Y, Ligthart J, Regar E (2009) Incomplete stent apposition and delayed tissue coverage are more frequent in drug-eluting stents implanted during primary percutaneous coronary intervention for ST-segment elevation myocardial infarction than in drug-eluting stents implanted for stable/unstable angina: insights from optical coherence tomography. JACC Cardiovasc Interv 2(5):445–452PubMedCrossRef
13.
Zurück zum Zitat Kimura T, Abe K, Shizuta S, Odashiro K, Yoshida Y, Sakai K, Kaitani K, Inoue K, Nakagawa Y, Yokoi H, Iwabuchi M, Hamasaki N, Nosaka H, Nobuyoshi M (2002) Long-term clinical and angiographic follow-up after coronary stent placement in native coronary arteries. Circulation 105(25):2986–2991PubMedCrossRef Kimura T, Abe K, Shizuta S, Odashiro K, Yoshida Y, Sakai K, Kaitani K, Inoue K, Nakagawa Y, Yokoi H, Iwabuchi M, Hamasaki N, Nosaka H, Nobuyoshi M (2002) Long-term clinical and angiographic follow-up after coronary stent placement in native coronary arteries. Circulation 105(25):2986–2991PubMedCrossRef
14.
Zurück zum Zitat Jang IK, Bouma BE, Kang DH, Park SJ, Park SW, Seung KB, Choi KB, Shishkov M, Schlendorf K, Pomerantsev E, Houser SL, Aretz HT, Tearney GJ (2002) Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasound. J Am Coll Cardiol 39(4):604–609PubMedCrossRef Jang IK, Bouma BE, Kang DH, Park SJ, Park SW, Seung KB, Choi KB, Shishkov M, Schlendorf K, Pomerantsev E, Houser SL, Aretz HT, Tearney GJ (2002) Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasound. J Am Coll Cardiol 39(4):604–609PubMedCrossRef
15.
Zurück zum Zitat Yabushita H, Bouma BE, Houser SL, Aretz HT, Jang IK, Schlendorf KH, Kauffman CR, Shishkov M, Kang DH, Halpern EF, Tearney GJ (2002) Characterization of human atherosclerosis by optical coherence tomography. Circulation 106(13):1640–1645PubMedCrossRef Yabushita H, Bouma BE, Houser SL, Aretz HT, Jang IK, Schlendorf KH, Kauffman CR, Shishkov M, Kang DH, Halpern EF, Tearney GJ (2002) Characterization of human atherosclerosis by optical coherence tomography. Circulation 106(13):1640–1645PubMedCrossRef
16.
Zurück zum Zitat Kim JS, Fan C, Choi D, Jang IK, Lee JM, Kim TH, Park SM, Paik SI, Ko YG, Hong MK, Jang Y, Chung N (2011) Different patterns of neointimal coverage between acute coronary syndrome and stable angina after various types of drug-eluting stents implantation; 9-month follow-up optical coherence tomography study. Int J Cardiol 146(3):341–346PubMedCrossRef Kim JS, Fan C, Choi D, Jang IK, Lee JM, Kim TH, Park SM, Paik SI, Ko YG, Hong MK, Jang Y, Chung N (2011) Different patterns of neointimal coverage between acute coronary syndrome and stable angina after various types of drug-eluting stents implantation; 9-month follow-up optical coherence tomography study. Int J Cardiol 146(3):341–346PubMedCrossRef
17.
Zurück zum Zitat Moore P, Barlis P, Spiro J, Ghimire G, Roughton M, Di Mario C, Wallis W, Ilsley C, Mitchell A, Mason M, Kharbanda R, Vincent P, Sherwin S, Dalby M (2009) A randomized optical coherence tomography study of coronary stent strut coverage and luminal protrusion with rapamycin-eluting stents. JACC Cardiovasc Interv 2(5):437–444PubMedCrossRef Moore P, Barlis P, Spiro J, Ghimire G, Roughton M, Di Mario C, Wallis W, Ilsley C, Mitchell A, Mason M, Kharbanda R, Vincent P, Sherwin S, Dalby M (2009) A randomized optical coherence tomography study of coronary stent strut coverage and luminal protrusion with rapamycin-eluting stents. JACC Cardiovasc Interv 2(5):437–444PubMedCrossRef
18.
Zurück zum Zitat Takano M, Yamamoto M, Inami S, Murakami D, Ohba T, Seino Y, Mizuno K (2009) Appearance of lipid-laden intima and neovascularization after implantation of bare-metal stents extended late-phase observation by intracoronary optical coherence tomography. J Am Coll Cardiol 55(1):26–32PubMedCrossRef Takano M, Yamamoto M, Inami S, Murakami D, Ohba T, Seino Y, Mizuno K (2009) Appearance of lipid-laden intima and neovascularization after implantation of bare-metal stents extended late-phase observation by intracoronary optical coherence tomography. J Am Coll Cardiol 55(1):26–32PubMedCrossRef
19.
Zurück zum Zitat Kitabata H, Tanaka A, Kubo T, Takarada S, Kashiwagi M, Tsujioka H, Ikejima H, Kuroi A, Kataiwa H, Ishibashi K, Komukai K, Tanimoto T, Ino Y, Hirata K, Nakamura N, Mizukoshi M, Imanishi T, Akasaka T (2010) Relation of microchannel structure identified by optical coherence tomography to plaque vulnerability in patients with coronary artery disease. Am J Cardiol 105(12):1673–1678PubMedCrossRef Kitabata H, Tanaka A, Kubo T, Takarada S, Kashiwagi M, Tsujioka H, Ikejima H, Kuroi A, Kataiwa H, Ishibashi K, Komukai K, Tanimoto T, Ino Y, Hirata K, Nakamura N, Mizukoshi M, Imanishi T, Akasaka T (2010) Relation of microchannel structure identified by optical coherence tomography to plaque vulnerability in patients with coronary artery disease. Am J Cardiol 105(12):1673–1678PubMedCrossRef
20.
Zurück zum Zitat Kimura T, Morimoto T, Kozuma K, Honda Y, Kume T, Aizawa T, Mitsudo K, Miyazaki S, Yamaguchi T, Hiyoshi E, Nishimura E, Isshiki T (2010) Comparisons of baseline demographics, clinical presentation, and long-term outcome among patients with early, late, and very late stent thrombosis of sirolimus-eluting stents: observations from the registry of stent thrombosis for review and reevaluation (RESTART). Circulation 122(1):52–61PubMedCrossRef Kimura T, Morimoto T, Kozuma K, Honda Y, Kume T, Aizawa T, Mitsudo K, Miyazaki S, Yamaguchi T, Hiyoshi E, Nishimura E, Isshiki T (2010) Comparisons of baseline demographics, clinical presentation, and long-term outcome among patients with early, late, and very late stent thrombosis of sirolimus-eluting stents: observations from the registry of stent thrombosis for review and reevaluation (RESTART). Circulation 122(1):52–61PubMedCrossRef
21.
Zurück zum Zitat Stone GW, Ellis SG, Cox DA, Hermiller J, O’Shaughnessy C, Mann JT, Turco M, Caputo R, Bergin P, Greenberg J, Popma JJ, Russell ME (2004) A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med 350(3):221–231PubMedCrossRef Stone GW, Ellis SG, Cox DA, Hermiller J, O’Shaughnessy C, Mann JT, Turco M, Caputo R, Bergin P, Greenberg J, Popma JJ, Russell ME (2004) A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med 350(3):221–231PubMedCrossRef
22.
Zurück zum Zitat Ong AT, McFadden EP, Regar E, de Jaegere PP, van Domburg RT, Serruys PW (2005) Late angiographic stent thrombosis (LAST) events with drug-eluting stents. J Am Coll Cardiol 45(12):2088–2092PubMedCrossRef Ong AT, McFadden EP, Regar E, de Jaegere PP, van Domburg RT, Serruys PW (2005) Late angiographic stent thrombosis (LAST) events with drug-eluting stents. J Am Coll Cardiol 45(12):2088–2092PubMedCrossRef
23.
Zurück zum Zitat Sawada T, Shite J, Shinke T, Tanino Y, Ogasawara D, Kawamori H, Kato H, Miyoshi N, Yoshino N, Hirata K (2008) Very late thrombosis of sirolimus-eluting stent due to late malapposition: serial observations with optical coherence tomography. J Cardiol 52(3):290–295PubMedCrossRef Sawada T, Shite J, Shinke T, Tanino Y, Ogasawara D, Kawamori H, Kato H, Miyoshi N, Yoshino N, Hirata K (2008) Very late thrombosis of sirolimus-eluting stent due to late malapposition: serial observations with optical coherence tomography. J Cardiol 52(3):290–295PubMedCrossRef
24.
Zurück zum Zitat Grewe PH, Deneke T, Machraoui A, Barmeyer J, Muller KM (2000) Acute and chronic tissue response to coronary stent implantation: pathologic findings in human specimen. J Am Coll Cardiol 35(1):157–163PubMedCrossRef Grewe PH, Deneke T, Machraoui A, Barmeyer J, Muller KM (2000) Acute and chronic tissue response to coronary stent implantation: pathologic findings in human specimen. J Am Coll Cardiol 35(1):157–163PubMedCrossRef
25.
Zurück zum Zitat Takano M, Yamamoto M, Inami S, Murakami D, Seimiya K, Ohba T, Seino Y, Mizuno K (2008) Long-term follow-up evaluation after sirolimus-eluting stent implantation by optical coherence tomography: do uncovered struts persist? J Am Coll Cardiol 51(9):968–969PubMedCrossRef Takano M, Yamamoto M, Inami S, Murakami D, Seimiya K, Ohba T, Seino Y, Mizuno K (2008) Long-term follow-up evaluation after sirolimus-eluting stent implantation by optical coherence tomography: do uncovered struts persist? J Am Coll Cardiol 51(9):968–969PubMedCrossRef
26.
Zurück zum Zitat Matsumoto D, Shite J, Shinke T, Otake H, Tanino Y, Ogasawara D, Sawada T, Paredes OL, Hirata K, Yokoyama M (2007) Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography. Eur Heart J 28(8):961–967PubMedCrossRef Matsumoto D, Shite J, Shinke T, Otake H, Tanino Y, Ogasawara D, Sawada T, Paredes OL, Hirata K, Yokoyama M (2007) Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography. Eur Heart J 28(8):961–967PubMedCrossRef
27.
Zurück zum Zitat Takano M, Mizuno K (2007) Angioscopic findings after drug-eluting stent implantation. Herz 32(4):281–286PubMedCrossRef Takano M, Mizuno K (2007) Angioscopic findings after drug-eluting stent implantation. Herz 32(4):281–286PubMedCrossRef
28.
Zurück zum Zitat Asakura M, Ueda Y, Nanto S, Hirayama A, Adachi T, Kitakaze M, Hori M, Kodama K (1998) Remodeling of in-stent neointima, which became thinner and transparent over 3 years: serial angiographic and angioscopic follow-up. Circulation 97(20):2003–2006PubMedCrossRef Asakura M, Ueda Y, Nanto S, Hirayama A, Adachi T, Kitakaze M, Hori M, Kodama K (1998) Remodeling of in-stent neointima, which became thinner and transparent over 3 years: serial angiographic and angioscopic follow-up. Circulation 97(20):2003–2006PubMedCrossRef
29.
Zurück zum Zitat Isner JM, Kearney M, Bortman S, Passeri J (1995) Apoptosis in human atherosclerosis and restenosis. Circulation 91(11):2703–2711PubMedCrossRef Isner JM, Kearney M, Bortman S, Passeri J (1995) Apoptosis in human atherosclerosis and restenosis. Circulation 91(11):2703–2711PubMedCrossRef
Metadaten
Titel
Neointimal tissue characteristics following sirolimus-eluting stent implantation: OCT quantitative tissue property analysis
verfasst von
Jingbo Hou
Haibo Jia
Haixia Liu
Zhigang Han
Shuang Yang
Chenyang Xu
Joseph Schmitt
Shaosong Zhang
Bo Yu
Ik-Kyung Jang
Publikationsdatum
01.12.2012
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 8/2012
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-012-0031-7

Weitere Artikel der Ausgabe 8/2012

The International Journal of Cardiovascular Imaging 8/2012 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.