Skip to main content
Erschienen in: Journal of Interventional Cardiac Electrophysiology 2/2012

01.08.2012

Pulmonary vein isolation to treat paroxysmal atrial fibrillation: conventional versus multi-electrode radiofrequency ablation

verfasst von: Rypko J. Beukema, Arif Elvan, Jaap Jan J. Smit, Peter Paul H. M. Delnoy, Anand R. Ramdat Misier, Vivek Reddy

Erschienen in: Journal of Interventional Cardiac Electrophysiology | Ausgabe 2/2012

Einloggen, um Zugang zu erhalten

Abstract

Purpose

For patients with symptomatic atrial fibrillation (AF), a curvilinear multi-electrode ablation (MEA) catheter has been reported to be successful to achieve pulmonary vein (PV) isolation. However, this approach has not been compared prospectively with conventional PV isolation (CPVI) using a standard circular mapping catheter and 3D electro-anatomic mapping. In this prospective non-randomized study, we compared the efficacy of these two techniques.

Methods

Of 185 consecutive patients, age 54.6 ± 10.1 years, with symptomatic paroxysmal AF (PAF), 96 patients underwent PV isolation by CPVI and 89 patients underwent MEA to isolate the PVs. CPVI was performed by encircling the left- and right-sided PVs. During MEA, the PV ablation catheter (Medtronic, USA) was used to isolate PVs with duty-cycled radiofrequency energy.

Results

The mean procedure time was 171.73 ± 52.87 min for CPVI and 133.25 ± 37.99 min for MEA, respectively (P < 0.001). The mean fluoroscopy time was 31.07 ± 14.97 for CPVI and 30.07 ± 11.45 min for MEA (P = 0.651). At 12 months, 80% of patients who underwent CPVI and 82% of patients who underwent MEA were free of symptomatic PAF off antiarrhythmic drug therapy (P = 0.989). Among the variables of age, gender, duration and frequency of PAF, left ventricular ejection fraction, left atrial size, structural heart disease, and the ablation technique, only an increased left atrial size was an independent predictor of recurrent PAF. Left atrial flutter occurred after CPVI in two patients and after MEA ablation in three patients.

Conclusion

In patients undergoing catheter ablation for PAF, MEA and CPVI proved equally efficacious.
Literatur
1.
Zurück zum Zitat Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., et al. (1998). Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. The New England Journal of Medicine, 339, 659–666.PubMedCrossRef Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., et al. (1998). Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. The New England Journal of Medicine, 339, 659–666.PubMedCrossRef
2.
Zurück zum Zitat Pappone, C., Rosanio, S., Oreto, G., Tocchi, M., Gugliotta, F., Vicedomini, G., et al. (2000). Circumferential radiofrequency ablation of pulmonary vein ostia: A new anatomic approach for curing atrial fibrillation. Circulation, 102, 2619–2628.PubMedCrossRef Pappone, C., Rosanio, S., Oreto, G., Tocchi, M., Gugliotta, F., Vicedomini, G., et al. (2000). Circumferential radiofrequency ablation of pulmonary vein ostia: A new anatomic approach for curing atrial fibrillation. Circulation, 102, 2619–2628.PubMedCrossRef
3.
Zurück zum Zitat Oral, H., Scharf, C., Chugh, A., Hall, B., Cheung, P., Good, E., et al. (2003). Catheter ablation for paroxysmal atrial fibrillation: Segmental pulmonary vein ablation versus left atrial ablation. Circulation, 108, 2355–2360.PubMedCrossRef Oral, H., Scharf, C., Chugh, A., Hall, B., Cheung, P., Good, E., et al. (2003). Catheter ablation for paroxysmal atrial fibrillation: Segmental pulmonary vein ablation versus left atrial ablation. Circulation, 108, 2355–2360.PubMedCrossRef
4.
Zurück zum Zitat Ouyang, F., Bänsch, D., Ernst, S., Schaumann, A., Hachiya, H., Chen, M., et al. (2004). Complete isolation of left atrium surrounding the pulmonary veins: New insights from the double-Lasso technique in paroxysmal atrial fibrillation. Circulation, 110, 2090–2096.PubMedCrossRef Ouyang, F., Bänsch, D., Ernst, S., Schaumann, A., Hachiya, H., Chen, M., et al. (2004). Complete isolation of left atrium surrounding the pulmonary veins: New insights from the double-Lasso technique in paroxysmal atrial fibrillation. Circulation, 110, 2090–2096.PubMedCrossRef
5.
Zurück zum Zitat Beukema, W. P., Elvan, A., Sie, H. T., Ramdat Misier, A. R., & Wellens, H. J. J. (2005). Successful radiofrequency ablation in patients with previous atrial fibrillation results in a significant decrease in left atrial size. Circulation, 112, 2089–2095.PubMedCrossRef Beukema, W. P., Elvan, A., Sie, H. T., Ramdat Misier, A. R., & Wellens, H. J. J. (2005). Successful radiofrequency ablation in patients with previous atrial fibrillation results in a significant decrease in left atrial size. Circulation, 112, 2089–2095.PubMedCrossRef
6.
Zurück zum Zitat Beukema, R., Beukema, W. P., Smit, J. J. J., Ramdat Misier, A. R., Delnoy, P. P., & Elvan, A. (2010). Efficacy of multi-electrode duty-cycled radiofrequency ablation for pulmonary vein disconnection in patients with paroxysmal and persistent atrial fibrillation. Europace, 12, 502–507.PubMedCrossRef Beukema, R., Beukema, W. P., Smit, J. J. J., Ramdat Misier, A. R., Delnoy, P. P., & Elvan, A. (2010). Efficacy of multi-electrode duty-cycled radiofrequency ablation for pulmonary vein disconnection in patients with paroxysmal and persistent atrial fibrillation. Europace, 12, 502–507.PubMedCrossRef
7.
Zurück zum Zitat Boersma, L. V., Wijffels, M. C., Oral, H., Wever, E. F., & Morady, F. (2008). Pulmonary vein isolation by duty-cycled bipolar and unipolar radiofrequency energy with a multielectrode ablation catheter. Heart Rhythm, 5, 1635–1642.PubMedCrossRef Boersma, L. V., Wijffels, M. C., Oral, H., Wever, E. F., & Morady, F. (2008). Pulmonary vein isolation by duty-cycled bipolar and unipolar radiofrequency energy with a multielectrode ablation catheter. Heart Rhythm, 5, 1635–1642.PubMedCrossRef
8.
Zurück zum Zitat Scharf, C., Boersma, L., Davies, W., Kanagaratnam, P., Peters, N. S., Paul, V., et al. (2009). Ablation of persistent atrial fibrillation using multielectrode catheters and duty-cycled radiofrequency energy. Journal of the American College of Cardiology, 54, 1450–1456.PubMedCrossRef Scharf, C., Boersma, L., Davies, W., Kanagaratnam, P., Peters, N. S., Paul, V., et al. (2009). Ablation of persistent atrial fibrillation using multielectrode catheters and duty-cycled radiofrequency energy. Journal of the American College of Cardiology, 54, 1450–1456.PubMedCrossRef
9.
Zurück zum Zitat Bittner, A., Mönnig, G., Zellerhoff, S., Pott, C., Köbe, J., Dechering, D., et al. (2011). Randomized study comparing duty-cycled bipolar and unipolar radiofrequency with point-by-point ablation in pulmonary vein isolation. Heart Rhythm, 8, 1383–1390.PubMedCrossRef Bittner, A., Mönnig, G., Zellerhoff, S., Pott, C., Köbe, J., Dechering, D., et al. (2011). Randomized study comparing duty-cycled bipolar and unipolar radiofrequency with point-by-point ablation in pulmonary vein isolation. Heart Rhythm, 8, 1383–1390.PubMedCrossRef
10.
Zurück zum Zitat Bulava, A., Haniš, J., Sitek, D., Ošmera, O., Karpianus, D., Šnorek, M., et al. (2010). Catheter ablation for paroxysmal atrial fibrillation: A randomized comparison between multielectrode catheter and point-by-point ablation. PACE, 33, 1039–1046.PubMedCrossRef Bulava, A., Haniš, J., Sitek, D., Ošmera, O., Karpianus, D., Šnorek, M., et al. (2010). Catheter ablation for paroxysmal atrial fibrillation: A randomized comparison between multielectrode catheter and point-by-point ablation. PACE, 33, 1039–1046.PubMedCrossRef
11.
Zurück zum Zitat Duytschaever, M., Anne, W., Papiashvili, G., Vandekerckhove, Y., & Tavernier, R. (2010). Mapping and isolation of the pulmonary veins using the PVAC catheter. PACE, 33, 168–178.PubMedCrossRef Duytschaever, M., Anne, W., Papiashvili, G., Vandekerckhove, Y., & Tavernier, R. (2010). Mapping and isolation of the pulmonary veins using the PVAC catheter. PACE, 33, 168–178.PubMedCrossRef
12.
Zurück zum Zitat Wieczorek, M., Hoeltgen, R., Brueck, M., Bandorski, D., Akin, E., & Salili, A. R. (2010). Pulmonary vein isolation by duty-cycled bipolar and unipolar antrum ablation using a novel multielectrode ablation catheter system: First clinical results. Journal of Interventional Cardiac Electrophysiology, 27, 23–31.PubMedCrossRef Wieczorek, M., Hoeltgen, R., Brueck, M., Bandorski, D., Akin, E., & Salili, A. R. (2010). Pulmonary vein isolation by duty-cycled bipolar and unipolar antrum ablation using a novel multielectrode ablation catheter system: First clinical results. Journal of Interventional Cardiac Electrophysiology, 27, 23–31.PubMedCrossRef
13.
Zurück zum Zitat Fredersdorf, S., Weber, S., Jilek, C., Heinicke, N., Von Bary, C., Jungbauer, C., et al. (2009). Safe and rapid isolation of pulmonary veins using a novel circular ablation catheter and duty-cycled RF generator. Journal of Cardiovascular Electrophysiology, 20, 1097–1101.PubMedCrossRef Fredersdorf, S., Weber, S., Jilek, C., Heinicke, N., Von Bary, C., Jungbauer, C., et al. (2009). Safe and rapid isolation of pulmonary veins using a novel circular ablation catheter and duty-cycled RF generator. Journal of Cardiovascular Electrophysiology, 20, 1097–1101.PubMedCrossRef
14.
Zurück zum Zitat Beukema, R., Beukema, W. P., Sie, H. T., Ramdat Misier, A. R., Delnoy, P. P., & Elvan, A. (2009). Monitoring of atrial fibrillation burden after surgical ablation: relevancy of end-point criteria after radiofrequency ablation treatment of patients with lone atrial fibrillation. Interactive Cardiovascular and Thoracic Surgery, 9, 956–959.PubMedCrossRef Beukema, R., Beukema, W. P., Sie, H. T., Ramdat Misier, A. R., Delnoy, P. P., & Elvan, A. (2009). Monitoring of atrial fibrillation burden after surgical ablation: relevancy of end-point criteria after radiofrequency ablation treatment of patients with lone atrial fibrillation. Interactive Cardiovascular and Thoracic Surgery, 9, 956–959.PubMedCrossRef
15.
Zurück zum Zitat Satomi, K., Bänsch, D., Tilz, R., Chun, J., Ernst, S., Antz, M., et al. (2008). Left atrial and pulmonary vein macroreentrant tachycardia associated with double conduction gaps: a novel type of man-made tachycardia after circumferential pulmonary vein isolation. Heart Rhythm, 5, 43–51.PubMedCrossRef Satomi, K., Bänsch, D., Tilz, R., Chun, J., Ernst, S., Antz, M., et al. (2008). Left atrial and pulmonary vein macroreentrant tachycardia associated with double conduction gaps: a novel type of man-made tachycardia after circumferential pulmonary vein isolation. Heart Rhythm, 5, 43–51.PubMedCrossRef
16.
Zurück zum Zitat Ouyang, F., Antz, M., Ernst, S., Hachiya, H., Mavrakis, H., Deger, F. T., et al. (2005). Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: Lessons from double Lasso technique. Circulation, 111, 127–135.PubMedCrossRef Ouyang, F., Antz, M., Ernst, S., Hachiya, H., Mavrakis, H., Deger, F. T., et al. (2005). Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: Lessons from double Lasso technique. Circulation, 111, 127–135.PubMedCrossRef
17.
Zurück zum Zitat Bertaglia, E., Tondo, C., De Simone, A., Zoppo, F., Mantica, M., Turco, P., et al. (2010). Does catheter ablation cure atrial fibrillation? Single-procedure outcome of drug-refractory atrial fibrillation ablation: A 6-year multicentre experience. Europace, 12, 181–187.PubMedCrossRef Bertaglia, E., Tondo, C., De Simone, A., Zoppo, F., Mantica, M., Turco, P., et al. (2010). Does catheter ablation cure atrial fibrillation? Single-procedure outcome of drug-refractory atrial fibrillation ablation: A 6-year multicentre experience. Europace, 12, 181–187.PubMedCrossRef
18.
Zurück zum Zitat Shah, A. N., Mittal, S., Sichrovsky, T. C., Cotiga, D., Arshad, A., Maleki, K., et al. (2008). Long-term outcome following successful pulmonary vein isolation: Pattern and prediction of very late recurrence. Journal of Cardiovascular Electrophysiology, 19, 661–667.PubMedCrossRef Shah, A. N., Mittal, S., Sichrovsky, T. C., Cotiga, D., Arshad, A., Maleki, K., et al. (2008). Long-term outcome following successful pulmonary vein isolation: Pattern and prediction of very late recurrence. Journal of Cardiovascular Electrophysiology, 19, 661–667.PubMedCrossRef
19.
Zurück zum Zitat Gaita, F., Leclercq, J. F., Schumacher, B., Scaglione, M., Toso, E., Halimi, F., et al. (2011). Incidence of silent cerebral thromboembolic lesions after atrial fibrillation ablation may change according to technology used: Comparison of irrigated radioferequency, multipolar nonirrigated catheter and cryoballoon. Journal of Cardiovascular Electrophysiology, 22, 961–968.PubMedCrossRef Gaita, F., Leclercq, J. F., Schumacher, B., Scaglione, M., Toso, E., Halimi, F., et al. (2011). Incidence of silent cerebral thromboembolic lesions after atrial fibrillation ablation may change according to technology used: Comparison of irrigated radioferequency, multipolar nonirrigated catheter and cryoballoon. Journal of Cardiovascular Electrophysiology, 22, 961–968.PubMedCrossRef
20.
Zurück zum Zitat Hegland, D., Piccini, J. P., Goldstein, L. B., & Daubert, J. P. (2011). Cerebral magnetic resonance findings in asymptomatic patients after atrial fibrillation catheter ablation: Cause for alarm of further study? Journal of Cardiovascular Electrophysiology, 22, 969–972.PubMedCrossRef Hegland, D., Piccini, J. P., Goldstein, L. B., & Daubert, J. P. (2011). Cerebral magnetic resonance findings in asymptomatic patients after atrial fibrillation catheter ablation: Cause for alarm of further study? Journal of Cardiovascular Electrophysiology, 22, 969–972.PubMedCrossRef
21.
Zurück zum Zitat Deneke, T., Bünz, K., Bastian, A., Päsler, M., Anders, H., Lehmann, R., et al. (2011). Utility of esophageal temperature monitoring during pulmonary vein isolation for atrial fibrillation using duty-cycled phased radiofrequency ablation. Journal of Cardiovascular Electrophysiology, 22, 255–261.PubMedCrossRef Deneke, T., Bünz, K., Bastian, A., Päsler, M., Anders, H., Lehmann, R., et al. (2011). Utility of esophageal temperature monitoring during pulmonary vein isolation for atrial fibrillation using duty-cycled phased radiofrequency ablation. Journal of Cardiovascular Electrophysiology, 22, 255–261.PubMedCrossRef
22.
Zurück zum Zitat Wieczorek, M., Hoeltgen, R., Akin, E., Salini, A. R., Oral, H., & Morady, F. (2010). Results of short-term and long-term pulmonary vein isolation for paroxysmal atrial fibrillation using duty-cycled bipolar and unipolar radiofrequency energy. Journal of Cardiovascular Electrophysiology, 21, 399–405.PubMedCrossRef Wieczorek, M., Hoeltgen, R., Akin, E., Salini, A. R., Oral, H., & Morady, F. (2010). Results of short-term and long-term pulmonary vein isolation for paroxysmal atrial fibrillation using duty-cycled bipolar and unipolar radiofrequency energy. Journal of Cardiovascular Electrophysiology, 21, 399–405.PubMedCrossRef
23.
Zurück zum Zitat Tivig, C., Dang, L., Brunner-La Rocca, H. P., Ozcan, S., Duru, F., & Scharf, C. (2010). Duty-cycled unipolar/bipolar versus conventional radiofrequency ablation in paroxysmal and persistent atrial fibrillation. International Journal of Cardiology, Dec 30. [Epub ahead of print]. Tivig, C., Dang, L., Brunner-La Rocca, H. P., Ozcan, S., Duru, F., & Scharf, C. (2010). Duty-cycled unipolar/bipolar versus conventional radiofrequency ablation in paroxysmal and persistent atrial fibrillation. International Journal of Cardiology, Dec 30. [Epub ahead of print].
Metadaten
Titel
Pulmonary vein isolation to treat paroxysmal atrial fibrillation: conventional versus multi-electrode radiofrequency ablation
verfasst von
Rypko J. Beukema
Arif Elvan
Jaap Jan J. Smit
Peter Paul H. M. Delnoy
Anand R. Ramdat Misier
Vivek Reddy
Publikationsdatum
01.08.2012
Verlag
Springer US
Erschienen in
Journal of Interventional Cardiac Electrophysiology / Ausgabe 2/2012
Print ISSN: 1383-875X
Elektronische ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-011-9653-2

Weitere Artikel der Ausgabe 2/2012

Journal of Interventional Cardiac Electrophysiology 2/2012 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.