Erschienen in: HSS Journal ® 1/2005

01.09.2005 | Original Article

Radiostereometric Analysis: The Hip

verfasst von: F. Bottner, MD, E. Su, B. Nestor, MD, B. Azzis, T. P. Sculco, MD, M. Bostrom, MD

Erschienen in: HSS Journal ® | Ausgabe 1/2005

Einloggen, um Zugang zu erhalten

Excerpt

Radiostereometric analysis is an accurate method of determining the migration and wear of orthopaedic implants such as total hip arthroplasties. While the overall concept of RSA is relatively straightforward: determining the precise location of two distinct objects relative to each other in three dimension such as the relative position of the femoral component and the proximal femur, the actual practical application is somewhat more complex. In radiostereometric analysis the position in space of the original object is reconstructed from a two dimensional x-ray film (Fig. 1). In order to reconstruct the position of segments within the human body, each segment is marked with at least three tantalum beads. Movement between segments is then calculated by localizing each segment in a coordinate system.
Literatur
1.
Zurück zum Zitat Davidson M (1898) Roentgen rays and localization. An apparatus for exact measurement and localization by means of roentgen rays. Brit Med J 10 Davidson M (1898) Roentgen rays and localization. An apparatus for exact measurement and localization by means of roentgen rays. Brit Med J 10
2.
Zurück zum Zitat Selvik, G 1989Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal systemActa Orthop Scand232151 Selvik, G 1989Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal systemActa Orthop Scand232151
3.
Zurück zum Zitat Ryd, L, Yuan, X, Lofgren, H 2000Methods for determining the accuracy of radiostereometric analysisActa Orthop Scand71403408CrossRefPubMed Ryd, L, Yuan, X, Lofgren, H 2000Methods for determining the accuracy of radiostereometric analysisActa Orthop Scand71403408CrossRefPubMed
4.
Zurück zum Zitat Sutherland, CJ, Wilde, AH, Borden, LS, Marks, KE 1982A ten-year follow-up of one hundred consecutive Müller curved-stem total hip replacement arthroplastiesJ Bone Jt Surg64-A970982 Sutherland, CJ, Wilde, AH, Borden, LS, Marks, KE 1982A ten-year follow-up of one hundred consecutive Müller curved-stem total hip replacement arthroplastiesJ Bone Jt Surg64-A970982
5.
Zurück zum Zitat Malchau, H, Kärrholm, J, Wang, YX, Herberts, P 1995Accuracy of migration analysis in hip arthroplasty: digitized and conventional radiography, compared to radiostereometry in 51 patientsActa Orthop Scand66418424PubMed Malchau, H, Kärrholm, J, Wang, YX, Herberts, P 1995Accuracy of migration analysis in hip arthroplasty: digitized and conventional radiography, compared to radiostereometry in 51 patientsActa Orthop Scand66418424PubMed
6.
Zurück zum Zitat Biedermann, R, Krismer, M, Stöckl, B, Mayrhofer, P, Ornstein, E, Franzen, H 1999Accuracy of EBRA-FCA in the measurement of migration of femoral components of total hip replacementJ Bone Jt Surg81-B266272CrossRef Biedermann, R, Krismer, M, Stöckl, B, Mayrhofer, P, Ornstein, E, Franzen, H 1999Accuracy of EBRA-FCA in the measurement of migration of femoral components of total hip replacementJ Bone Jt Surg81-B266272CrossRef
7.
Zurück zum Zitat Soballe, K, Toksvig-Larsen, S, Gelineck, J, Fruensgaard, S, Hansen, ES, Ryd, L, Lucht, U, Bünger, C 1993Migration of hydroxyapatite coated femoral prostheses. A roentgen stereophotogrammetric studyJ Bone Jt Surg75-B681687 Soballe, K, Toksvig-Larsen, S, Gelineck, J, Fruensgaard, S, Hansen, ES, Ryd, L, Lucht, U, Bünger, C 1993Migration of hydroxyapatite coated femoral prostheses. A roentgen stereophotogrammetric studyJ Bone Jt Surg75-B681687
8.
Zurück zum Zitat Önsten, I, Berzins, A, Shott, S, Sumner, DR 2001Accuracy and precision of radiostereometric analysis in the measurement of THR femoral component translations: human and canine in vitro modelsJ Orthop Res1911621167CrossRefPubMed Önsten, I, Berzins, A, Shott, S, Sumner, DR 2001Accuracy and precision of radiostereometric analysis in the measurement of THR femoral component translations: human and canine in vitro modelsJ Orthop Res1911621167CrossRefPubMed
9.
Zurück zum Zitat Mjoberg, B 1986Loosening of the cemented hip prosthesis. Theimportance of head injuryActa Orthop Scand221 140 Mjoberg, B 1986Loosening of the cemented hip prosthesis. Theimportance of head injuryActa Orthop Scand221 140
10.
Zurück zum Zitat Ryd, L 1992Roentgen stereophotogrammetric analysis of prosthetic fixation in the hip and knee jointClin Ortop2765665 Ryd, L 1992Roentgen stereophotogrammetric analysis of prosthetic fixation in the hip and knee jointClin Ortop2765665
11.
Zurück zum Zitat Kärrholm, J, Borssen, B, Lowenhielm, G, Snorrason, F 1994Does early micromotion of femoral stem prostheses matter: 4–7 year stereoradiographic follow-up of 84 cemented prosthesesJ Bone Jt Surg76-B912917 Kärrholm, J, Borssen, B, Lowenhielm, G, Snorrason, F 1994Does early micromotion of femoral stem prostheses matter: 4–7 year stereoradiographic follow-up of 84 cemented prosthesesJ Bone Jt Surg76-B912917
12.
Zurück zum Zitat Huiskes, R, Verdonschot, N, Nivbrant, B 1998Migration, stem shape, and surface finish in cemented total hip arthroplastyClin Ortop355103112CrossRef Huiskes, R, Verdonschot, N, Nivbrant, B 1998Migration, stem shape, and surface finish in cemented total hip arthroplastyClin Ortop355103112CrossRef
13.
Zurück zum Zitat Dall, DM, Learmonth, ID, Solomon, MI, Miles, AW, Davenport, JM 1993Fracture and loosening of charnley femoral stemsJ Bone Jt Surg75-B259265 Dall, DM, Learmonth, ID, Solomon, MI, Miles, AW, Davenport, JM 1993Fracture and loosening of charnley femoral stemsJ Bone Jt Surg75-B259265
14.
Zurück zum Zitat Rockborn, P, Olsson, SS 1993Loosening and bone resorption in Exeter hip arthroplasties. Review at a minimum of five yearsJ Bone Jt Surg75-B865868 Rockborn, P, Olsson, SS 1993Loosening and bone resorption in Exeter hip arthroplasties. Review at a minimum of five yearsJ Bone Jt Surg75-B865868
15.
Zurück zum Zitat Stefansdottir, A, Franzen, H, Johnsson, R, Ornstein, E, Sundberg, M 2004Movement pattern of the Exeter femoral stem. A radiostereometric analysis of 22 primary hip arthroplasties followed for 5 yearsActa Orthop Scand75408414CrossRefPubMed Stefansdottir, A, Franzen, H, Johnsson, R, Ornstein, E, Sundberg, M 2004Movement pattern of the Exeter femoral stem. A radiostereometric analysis of 22 primary hip arthroplasties followed for 5 yearsActa Orthop Scand75408414CrossRefPubMed
16.
Zurück zum Zitat Kärrholm, J, Malchau, H, Snorrason, F, Herberts, P 1994Micromotion of femoral stems in total hip arthroplastyJ Bone Jt Surg76-A16921705 Kärrholm, J, Malchau, H, Snorrason, F, Herberts, P 1994Micromotion of femoral stems in total hip arthroplastyJ Bone Jt Surg76-A16921705
17.
Zurück zum Zitat Hamadouche, M, Witvoet, J, Porcher, R, Meunier, A, Sedel, L, Nizard, R 2001Hydroxyapatite-coated versus grit-blasted femoral stems. A prospective randomized study using EBRA-FCAJ Bone Jt Surg83-B979987CrossRef Hamadouche, M, Witvoet, J, Porcher, R, Meunier, A, Sedel, L, Nizard, R 2001Hydroxyapatite-coated versus grit-blasted femoral stems. A prospective randomized study using EBRA-FCAJ Bone Jt Surg83-B979987CrossRef
18.
Zurück zum Zitat Garcia-Cimbrelo, E, Cruz-Pardos, A, Madero, R, Ortega-Andreu, M 2003Total hip arthroplasty with use of the cementless Zweymüller Alloclassic system. A ten to thirteen year follow-up studyJ Bone Jt Surg85-A296303 Garcia-Cimbrelo, E, Cruz-Pardos, A, Madero, R, Ortega-Andreu, M 2003Total hip arthroplasty with use of the cementless Zweymüller Alloclassic system. A ten to thirteen year follow-up studyJ Bone Jt Surg85-A296303
19.
Zurück zum Zitat Grübl, A, Chiari, C, Gruber, M, Kaider, A, Gottsauner-Wolf, F 2002Cementless total hip arthroplasty with a tapered, rectangular titanium stem and a threaded cup. A minimum ten-year follow-upJ Bone Jt Surg84-A425431 Grübl, A, Chiari, C, Gruber, M, Kaider, A, Gottsauner-Wolf, F 2002Cementless total hip arthroplasty with a tapered, rectangular titanium stem and a threaded cup. A minimum ten-year follow-upJ Bone Jt Surg84-A425431
20.
Zurück zum Zitat Healy, WL, Casey, DJ, Iorio, R, Appleby, D 2002Evaluation of the porous-coated anatomic hip at 12 yearsJ Arthroplast17856863CrossRef Healy, WL, Casey, DJ, Iorio, R, Appleby, D 2002Evaluation of the porous-coated anatomic hip at 12 yearsJ Arthroplast17856863CrossRef
21.
Zurück zum Zitat Kawamura, H, Dunbar, MJ, Murray, P, Bourne, RB, Rorabeck, CH 2001The porous coated anatomic total hip replacment. A ten to fourteen-year follow-up study of a cementless total hip arthroplastyJ Bone Jt Surg83-A13331338 Kawamura, H, Dunbar, MJ, Murray, P, Bourne, RB, Rorabeck, CH 2001The porous coated anatomic total hip replacment. A ten to fourteen-year follow-up study of a cementless total hip arthroplastyJ Bone Jt Surg83-A13331338
22.
Zurück zum Zitat Keisu, KS, Orozco, F, Sharkey, PF, Hozack, WJ, Rothman, RH, McGurgan, FX 2001Primary cementless total hip arthroplasty in octogenarians. Two to eleven-year follow-upJ Bone Jt Surg83-A359363 Keisu, KS, Orozco, F, Sharkey, PF, Hozack, WJ, Rothman, RH, McGurgan, FX 2001Primary cementless total hip arthroplasty in octogenarians. Two to eleven-year follow-upJ Bone Jt Surg83-A359363
23.
Zurück zum Zitat Kim, YH 2002Bilateral cemented and cementless total hip arthroplastyJ Arthroplast17434440CrossRef Kim, YH 2002Bilateral cemented and cementless total hip arthroplastyJ Arthroplast17434440CrossRef
24.
Zurück zum Zitat Nercessian, OA, Wu, WH, Sarkissian, H 2001Clinical and radiographic results of cementless AML total hip arthroplasty in young patientsJ Arthroplast16312316CrossRef Nercessian, OA, Wu, WH, Sarkissian, H 2001Clinical and radiographic results of cementless AML total hip arthroplasty in young patientsJ Arthroplast16312316CrossRef
25.
Zurück zum Zitat Tanzer, M, Chan, S, Brooks, CE, Bobyn, JD 2001Primary cementless total hip arthroplasty using a modular femoral component. A minimum 6-year follow-upJ Arthroplast166470CrossRef Tanzer, M, Chan, S, Brooks, CE, Bobyn, JD 2001Primary cementless total hip arthroplasty using a modular femoral component. A minimum 6-year follow-upJ Arthroplast166470CrossRef
26.
Zurück zum Zitat Kim, YH, Oh, SH, Kim, JS 2003Primary total hip arthroplasty with a second generation cementless total hip prosthesis in patients younger than fifty years of ageJ Bone Jt Surg85-A109114 Kim, YH, Oh, SH, Kim, JS 2003Primary total hip arthroplasty with a second generation cementless total hip prosthesis in patients younger than fifty years of ageJ Bone Jt Surg85-A109114
27.
Zurück zum Zitat Keisu, KS, Orozco, F, McCallum, JD, Bissett, G, Hozack, WJ, Sharkey, PF, Rothman, RH 2001Cementless femoral fixation in the rheumatoid patient undergoing total hip arthroplasty. Minimum 5-year resultsJ Arthroplast16415421CrossRef Keisu, KS, Orozco, F, McCallum, JD, Bissett, G, Hozack, WJ, Sharkey, PF, Rothman, RH 2001Cementless femoral fixation in the rheumatoid patient undergoing total hip arthroplasty. Minimum 5-year resultsJ Arthroplast16415421CrossRef
28.
Zurück zum Zitat Bottner F, Zawadsky M, Su E, Bostrom M, Palm L, Ryd L, Sculco TP (2005) The impact of the weight bearing protocol on implant migration after cementless total hip arthroplasty. A radistereometric analysis. Clin Ortop (accepted for publication) Bottner F, Zawadsky M, Su E, Bostrom M, Palm L, Ryd L, Sculco TP (2005) The impact of the weight bearing protocol on implant migration after cementless total hip arthroplasty. A radistereometric analysis. Clin Ortop (accepted for publication)
29.
Zurück zum Zitat Rorabeck, CH, Bourne, RB, Mulliken, BD, Nayak, N, Laupacis, A, Tugwell, P, Feeney, D 1996The Nicolas Andry Award. Comparative results of cemented and cementless total hip arthroplastyClin Ortop325330344CrossRef Rorabeck, CH, Bourne, RB, Mulliken, BD, Nayak, N, Laupacis, A, Tugwell, P, Feeney, D 1996The Nicolas Andry Award. Comparative results of cemented and cementless total hip arthroplastyClin Ortop325330344CrossRef
30.
Zurück zum Zitat Thanner, J 1999The acetabular component in total hip arthroplasty. Evaluation of different fixation principlesActa Orthop Scand286141 Thanner, J 1999The acetabular component in total hip arthroplasty. Evaluation of different fixation principlesActa Orthop Scand286141
31.
Zurück zum Zitat Hacking, SA, Bobyn, JD, Tanzer, M, Krygier, JJ 1999The osseous response to corundum blasted implant surfaces in canine total hip arthroplasty modelClin Ortop364240253CrossRef Hacking, SA, Bobyn, JD, Tanzer, M, Krygier, JJ 1999The osseous response to corundum blasted implant surfaces in canine total hip arthroplasty modelClin Ortop364240253CrossRef
32.
Zurück zum Zitat Zhang, Y, Ahn, PB, Fitzpatrick, DC, Heiner, AD, Poggie, RA, Brown, TD 1999Interfacial frictional behavior: cancellous bone, cortical bone, and a novel porous tantalum biomaterialJ Musculoskelet Res3245251CrossRef Zhang, Y, Ahn, PB, Fitzpatrick, DC, Heiner, AD, Poggie, RA, Brown, TD 1999Interfacial frictional behavior: cancellous bone, cortical bone, and a novel porous tantalum biomaterialJ Musculoskelet Res3245251CrossRef
33.
Zurück zum Zitat Bobyn, JD, Stackpool, GJ, Hacking, SA, Tanzer, M, Krygier, JJ 1999Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterialJ Bone Jt Surg81-B907914CrossRef Bobyn, JD, Stackpool, GJ, Hacking, SA, Tanzer, M, Krygier, JJ 1999Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterialJ Bone Jt Surg81-B907914CrossRef
34.
Zurück zum Zitat Amstutz, HC 2000Innovations in design and technology: the story of hip arthroplastyClin Ortop3782330CrossRef Amstutz, HC 2000Innovations in design and technology: the story of hip arthroplastyClin Ortop3782330CrossRef
35.
Zurück zum Zitat Amstutz, HC, Dorey, F, O’Carroll, PF 1986THARIS resurfacing arthroplasty. Evolution and long-term resultsClin Ortop21392114 Amstutz, HC, Dorey, F, O’Carroll, PF 1986THARIS resurfacing arthroplasty. Evolution and long-term resultsClin Ortop21392114
36.
Zurück zum Zitat Ritter, MA, Gioe, TJ 1986Conventional versus resurfacing total hip arthroplasty. A long-term prospective study of concomitant bilateral implantation of prosthesesJ Bone Jt Surg68-A216225 Ritter, MA, Gioe, TJ 1986Conventional versus resurfacing total hip arthroplasty. A long-term prospective study of concomitant bilateral implantation of prosthesesJ Bone Jt Surg68-A216225
37.
Zurück zum Zitat Tracy, RB, McBryde, CW, Pynsent, PB 2005Birmingham hip resurfacing arthroplasty. A minimum follow-up of five yearsJ Bone Jt Surg87-B167170CrossRef Tracy, RB, McBryde, CW, Pynsent, PB 2005Birmingham hip resurfacing arthroplasty. A minimum follow-up of five yearsJ Bone Jt Surg87-B167170CrossRef
38.
Zurück zum Zitat Glyn-Jones, S, Gill, HS, McLardy-Smith, , Murray, DW 2004Roentgen stereophotogrammetric analysis of the Birmingham hip resurfacing arthroplasty. A two year studyJ Bone Jt Surg86-B172176CrossRef Glyn-Jones, S, Gill, HS, McLardy-Smith, , Murray, DW 2004Roentgen stereophotogrammetric analysis of the Birmingham hip resurfacing arthroplasty. A two year studyJ Bone Jt Surg86-B172176CrossRef
39.
Zurück zum Zitat Itayem, R, Arndt, A, Nistor, L, McMinn, D, Lundberg, A 2005Stability of the Birmingham hip resurfacing arthroplasty at two yearsJ Bone Jt Surg87-B158162CrossRef Itayem, R, Arndt, A, Nistor, L, McMinn, D, Lundberg, A 2005Stability of the Birmingham hip resurfacing arthroplasty at two yearsJ Bone Jt Surg87-B158162CrossRef
Metadaten
Titel
Radiostereometric Analysis: The Hip
verfasst von
F. Bottner, MD
E. Su
B. Nestor, MD
B. Azzis
T. P. Sculco, MD
M. Bostrom, MD
Publikationsdatum
01.09.2005
Erschienen in
HSS Journal ® / Ausgabe 1/2005
Print ISSN: 1556-3316
Elektronische ISSN: 1556-3324
DOI
https://doi.org/10.1007/s11420-005-0114-2

Weitere Artikel der Ausgabe 1/2005

HSS Journal ® 1/2005 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.