Skip to main content
Erschienen in: Clinical Orthopaedics and Related Research® 11/2008

01.11.2008 | Symposium: Papers Presented at the Annual Meetings of the Knee Society

Determining Femoral Component Position Using CAS and Measured Resection

verfasst von: James Benjamin, MD

Erschienen in: Clinical Orthopaedics and Related Research® | Ausgabe 11/2008

Einloggen, um Zugang zu erhalten

Abstract

To evaluate the ability of computer-assisted surgery (CAS) to accurately size and determine rotational alignment of the femoral component in TKA, the author reviewed femoral component position after 50 consecutive primary TKAs using a femur-first, measured resection workflow. The computer software used allowed femoral rotation to be selected based on epicondylar axis, posterior condylar axis, or anteroposterior axis. The final femoral component size and position was determined by the surgeon to avoid anterior notching, match the posterior-medial condyle resection, and flexed to match the plane of the anterior femoral cortex. Femoral sizing was confirmed intraoperatively with a standard sizing guide. The femoral component was downsized in 52% of patients from the size recommended by the computer software. The posterior condylar axis matched the implanted rotational position of the femoral component to within 1° in 64% of patients in contrast to the epicondylar axis (32%) and anteroposterior axis (26%). CAS provides information to make surgical decisions but does not replace clinical judgment. Landmark referencing may be compromised by limited surgical exposures leading to variation in implant positioning by computer software. A clear understanding of the principles of TKA is critical when using CAS to optimize implant sizing and position.
Literatur
1.
Zurück zum Zitat Akagi M, Matsusue Y, Mata T, Asada Y, Horiguchi M, Iida H, Nakamura T. Effect of rotational alignment on patellar tracking in total knee arthroplasty. Clin Orthop Relat Res. 1999;366:155–163.PubMedCrossRef Akagi M, Matsusue Y, Mata T, Asada Y, Horiguchi M, Iida H, Nakamura T. Effect of rotational alignment on patellar tracking in total knee arthroplasty. Clin Orthop Relat Res. 1999;366:155–163.PubMedCrossRef
2.
Zurück zum Zitat Akagi M, Yamashita E, Nakagawa T, Asano T, Nakamma T. Relationship between frontal knee alignment and reference axes in the distal femur. Clin Orthop Relat Res. 2001;388:147–156.PubMedCrossRef Akagi M, Yamashita E, Nakagawa T, Asano T, Nakamma T. Relationship between frontal knee alignment and reference axes in the distal femur. Clin Orthop Relat Res. 2001;388:147–156.PubMedCrossRef
3.
Zurück zum Zitat Anouchi Y, Whiteside L, Kaiser A, Milliano M. The effects of axial rotational alignment of the femoral component on knee stability and patellar tracking in total knee arthroplasty demonstrated on autopsy specimens. Clin Orthop Relat Res. 1993;287:170–177.PubMed Anouchi Y, Whiteside L, Kaiser A, Milliano M. The effects of axial rotational alignment of the femoral component on knee stability and patellar tracking in total knee arthroplasty demonstrated on autopsy specimens. Clin Orthop Relat Res. 1993;287:170–177.PubMed
4.
Zurück zum Zitat Arima J, Whiteside, L, McCarthy D, White S. Femoral rotational alignment based on the anteroposterior axis, in total knee arthroplasty in a valgus knee. J Bone Joint Surg Am. 1995;77:1331–1334.PubMed Arima J, Whiteside, L, McCarthy D, White S. Femoral rotational alignment based on the anteroposterior axis, in total knee arthroplasty in a valgus knee. J Bone Joint Surg Am. 1995;77:1331–1334.PubMed
5.
Zurück zum Zitat Berger R, Rubash H, Seel M, Thompson W, Crossett L. Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res. 1993;286:40–47.PubMed Berger R, Rubash H, Seel M, Thompson W, Crossett L. Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res. 1993;286:40–47.PubMed
6.
Zurück zum Zitat Berger RA, Crossett LS, Jacobs JJ, Rubash HE. Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res. 1998;356:144–153.PubMedCrossRef Berger RA, Crossett LS, Jacobs JJ, Rubash HE. Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res. 1998;356:144–153.PubMedCrossRef
7.
Zurück zum Zitat Chauhan S, Clark G, Lloyd S, Scott R, Breidahl W, Sikorski J. Computer-assisted total knee replacement. A controlled cadaver study using a multiparameter quantitative CT assessment of alignment. J Bone Joint Surg Br. 2004;86:818–823.PubMedCrossRef Chauhan S, Clark G, Lloyd S, Scott R, Breidahl W, Sikorski J. Computer-assisted total knee replacement. A controlled cadaver study using a multiparameter quantitative CT assessment of alignment. J Bone Joint Surg Br. 2004;86:818–823.PubMedCrossRef
8.
Zurück zum Zitat Chauhan S, Scott R, Breidahl W, Beaver R. Computer-assisted knee arthroplasty versus conventional jig-based technique. J Bone Joint Surg Br. 2004;86:373–377. Chauhan S, Scott R, Breidahl W, Beaver R. Computer-assisted knee arthroplasty versus conventional jig-based technique. J Bone Joint Surg Br. 2004;86:373–377.
9.
Zurück zum Zitat Chin PL, Yang KY, Yeo S, Lo NN. Randomized control trial comparing radiographic TKA implant placement using computer navigation versus conventional technique. J Arthroplasty. 2005;20:618–626.PubMedCrossRef Chin PL, Yang KY, Yeo S, Lo NN. Randomized control trial comparing radiographic TKA implant placement using computer navigation versus conventional technique. J Arthroplasty. 2005;20:618–626.PubMedCrossRef
10.
Zurück zum Zitat Churchill D, Incavo S, Johnson C, Beynnon B. The transepicondylar axis approximates the optimal flexion axis of the knee. Clin Orthop Relat Res. 1998;356:111–118.PubMedCrossRef Churchill D, Incavo S, Johnson C, Beynnon B. The transepicondylar axis approximates the optimal flexion axis of the knee. Clin Orthop Relat Res. 1998;356:111–118.PubMedCrossRef
11.
Zurück zum Zitat Decking R, Markmann Y, Fuchs J, Puhl W, Scharf HP. Leg axis after computer-navigated TKA: a prospective randomized trial comparing computer-navigated and manual implantation. J Arthroplasty. 2005;20:282–288.PubMedCrossRef Decking R, Markmann Y, Fuchs J, Puhl W, Scharf HP. Leg axis after computer-navigated TKA: a prospective randomized trial comparing computer-navigated and manual implantation. J Arthroplasty. 2005;20:282–288.PubMedCrossRef
12.
Zurück zum Zitat Donnelly W, Crawford R, Rimmington T, Whitehouse S, Whitting K. Effect of knee navigation on coronal alignment after total knee replacement . J Bone Joint Surg Br. 2004;86(Suppl IV):475. Donnelly W, Crawford R, Rimmington T, Whitehouse S, Whitting K. Effect of knee navigation on coronal alignment after total knee replacement . J Bone Joint Surg Br. 2004;86(Suppl IV):475.
13.
Zurück zum Zitat Faris PM, Ritter MA, Keating EM. Sagittal plane positioning of the femoral component in total knee arthroplasty. J Arthroplasty. 1988;3:355–358.PubMedCrossRef Faris PM, Ritter MA, Keating EM. Sagittal plane positioning of the femoral component in total knee arthroplasty. J Arthroplasty. 1988;3:355–358.PubMedCrossRef
14.
Zurück zum Zitat Fehring T, Odum S, Griffin W, Mason J, Nadaud M. Early failures in total knee arthroplasty. Clin Orthop Relat Res. 2001;392:315–318.PubMedCrossRef Fehring T, Odum S, Griffin W, Mason J, Nadaud M. Early failures in total knee arthroplasty. Clin Orthop Relat Res. 2001;392:315–318.PubMedCrossRef
15.
Zurück zum Zitat Gomes LSM, Bechtold JE, Gustilo RB. Patellar prosthesis positioning in total knee arthroplasty. Clin Orthop Relat Res. 1988;236:72–81.PubMed Gomes LSM, Bechtold JE, Gustilo RB. Patellar prosthesis positioning in total knee arthroplasty. Clin Orthop Relat Res. 1988;236:72–81.PubMed
16.
Zurück zum Zitat Grelsamer R, Bazos A, Proctor C. Radiographic analysis of patellar tilt. J Bone Joint Surg Br. 1993;5:822–824. Grelsamer R, Bazos A, Proctor C. Radiographic analysis of patellar tilt. J Bone Joint Surg Br. 1993;5:822–824.
17.
Zurück zum Zitat Griffin F, Insall JN, Scuderi G. The posterior condylar angle in osteoarthritic knees. J Arthroplasty. 1998;13:812–815.PubMedCrossRef Griffin F, Insall JN, Scuderi G. The posterior condylar angle in osteoarthritic knees. J Arthroplasty. 1998;13:812–815.PubMedCrossRef
18.
Zurück zum Zitat Haaker R, Stockheim M, Kamp M, Proff G, Breitenfelder J, Ottersbach A. Computer-assisted navigation increases precision of component placement in TKA. Clin Orthop Relat Res. 2005;433:152–159.PubMedCrossRef Haaker R, Stockheim M, Kamp M, Proff G, Breitenfelder J, Ottersbach A. Computer-assisted navigation increases precision of component placement in TKA. Clin Orthop Relat Res. 2005;433:152–159.PubMedCrossRef
19.
Zurück zum Zitat Hollister A, Jatana S, Singh A, Sullivan W, Lupichuk A. The axes of rotation of the knee. Clin Orthop Relat Res. 1993;290:259–268.PubMed Hollister A, Jatana S, Singh A, Sullivan W, Lupichuk A. The axes of rotation of the knee. Clin Orthop Relat Res. 1993;290:259–268.PubMed
20.
Zurück zum Zitat Hungerford D, Krackow K. Total joint arthroplasty of the knee. Clin Orthop Relat Res. 1985;192:23–33.PubMed Hungerford D, Krackow K. Total joint arthroplasty of the knee. Clin Orthop Relat Res. 1985;192:23–33.PubMed
21.
Zurück zum Zitat Insall J. Surgical techniques and instrumentation in total knee arthroplasty. In: Insall J, Windsor R, Scott W, Kelly M, Aglietti P, eds. Surgery of the Knee. 2nd ed. New York, NY: Churchill Livingstone; 1993:739–804. Insall J. Surgical techniques and instrumentation in total knee arthroplasty. In: Insall J, Windsor R, Scott W, Kelly M, Aglietti P, eds. Surgery of the Knee. 2nd ed. New York, NY: Churchill Livingstone; 1993:739–804.
22.
Zurück zum Zitat Jeffery R, Morris R, Denham R. Coronal alignment after total knee replacement. J Bone Joint Surg Br. 1991;73:709–714.PubMed Jeffery R, Morris R, Denham R. Coronal alignment after total knee replacement. J Bone Joint Surg Br. 1991;73:709–714.PubMed
23.
Zurück zum Zitat Jenny J, Boeri C. Low reproducibility of the intra-operative measurement of the transepicondylar axis during total knee replacement. Acta Orthop Scand. 2004;75:74–77.PubMedCrossRef Jenny J, Boeri C. Low reproducibility of the intra-operative measurement of the transepicondylar axis during total knee replacement. Acta Orthop Scand. 2004;75:74–77.PubMedCrossRef
24.
Zurück zum Zitat Jenny J, Clemens U, Kohler S, Kiefer H, Konermann W, Miehlke R. Consistency of implantation of a TKA with a non-image-based navigation system. J Arthroplasty. 2005;20:832–839.PubMedCrossRef Jenny J, Clemens U, Kohler S, Kiefer H, Konermann W, Miehlke R. Consistency of implantation of a TKA with a non-image-based navigation system. J Arthroplasty. 2005;20:832–839.PubMedCrossRef
25.
Zurück zum Zitat Kaper BP, Woolfrey M, Bourne RB. The effect of built-in external femoral rotation on patellofemoral tracking in the Genesis II total knee arthroplasty. J Arthroplasty. 2000;15:964–969.PubMedCrossRef Kaper BP, Woolfrey M, Bourne RB. The effect of built-in external femoral rotation on patellofemoral tracking in the Genesis II total knee arthroplasty. J Arthroplasty. 2000;15:964–969.PubMedCrossRef
26.
Zurück zum Zitat Kim Y, Kim J, Yoon S. Alignment and orientation of the components in total knee replacement with and without navigation support. A prospective, randomized study. J Bone Joint Surg Br. 2007;89:471–476.PubMedCrossRef Kim Y, Kim J, Yoon S. Alignment and orientation of the components in total knee replacement with and without navigation support. A prospective, randomized study. J Bone Joint Surg Br. 2007;89:471–476.PubMedCrossRef
27.
Zurück zum Zitat Lotke P, Ecker M. Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am. 1977;59:77–79.PubMed Lotke P, Ecker M. Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am. 1977;59:77–79.PubMed
28.
Zurück zum Zitat Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C. A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am. 2007;89:236–243.PubMedCrossRef Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C. A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am. 2007;89:236–243.PubMedCrossRef
29.
Zurück zum Zitat Nagamine R, White SE, McCarthy DS, Whiteside LA. Effect of rotational malposition of the femoral component on knee stability and kinematics after total knee arthroplasty. J Arthroplasty. 1995;10:265–270.PubMedCrossRef Nagamine R, White SE, McCarthy DS, Whiteside LA. Effect of rotational malposition of the femoral component on knee stability and kinematics after total knee arthroplasty. J Arthroplasty. 1995;10:265–270.PubMedCrossRef
30.
Zurück zum Zitat Olcott CW, Scott RD. A comparison of four intraoperative methods to determine femoral component rotation during total knee arthroplasty. J Arthroplasty. 2000;15:22–26.PubMedCrossRef Olcott CW, Scott RD. A comparison of four intraoperative methods to determine femoral component rotation during total knee arthroplasty. J Arthroplasty. 2000;15:22–26.PubMedCrossRef
31.
Zurück zum Zitat Poilvache PL, Insall JN, Scuderi GR, Font-Rodriguez DE. Rotational landmarks and sizing of the distal femur in total knee arthroplasty. Clin Orthop Relat Res. 1996;331:35–46.PubMedCrossRef Poilvache PL, Insall JN, Scuderi GR, Font-Rodriguez DE. Rotational landmarks and sizing of the distal femur in total knee arthroplasty. Clin Orthop Relat Res. 1996;331:35–46.PubMedCrossRef
32.
Zurück zum Zitat Rhoads DD, Noble PC, Reuben JD, Mahoney OM, Tullos HS. The effect of femoral component position on patellar tracking after total knee arthroplasty. Clin Orthop Relat Res. 1990;260:43–51.PubMed Rhoads DD, Noble PC, Reuben JD, Mahoney OM, Tullos HS. The effect of femoral component position on patellar tracking after total knee arthroplasty. Clin Orthop Relat Res. 1990;260:43–51.PubMed
33.
Zurück zum Zitat Rhoads DD, Noble PC, Reuben JD, Tullos HS. The effect of femoral component position on the kinematics of total knee arthroplasty. Clin Orthop Relat Res. 1993;286:122–129.PubMed Rhoads DD, Noble PC, Reuben JD, Tullos HS. The effect of femoral component position on the kinematics of total knee arthroplasty. Clin Orthop Relat Res. 1993;286:122–129.PubMed
34.
Zurück zum Zitat Ritter M, Faris P, Keating E, Meding J. Postoperative alignment of total knee replacement: its effect on survival. Clin Orthop Relat Res. 1994;299:153–156.PubMed Ritter M, Faris P, Keating E, Meding J. Postoperative alignment of total knee replacement: its effect on survival. Clin Orthop Relat Res. 1994;299:153–156.PubMed
35.
Zurück zum Zitat Siston R, Patel J, Goodman S, Delp S, Giori N. The variability of femoral rotational alignment in total knee arthroplasty. J Bone Joint Surg Am. 2005:87:2276–2280.PubMedCrossRef Siston R, Patel J, Goodman S, Delp S, Giori N. The variability of femoral rotational alignment in total knee arthroplasty. J Bone Joint Surg Am. 2005:87:2276–2280.PubMedCrossRef
36.
Zurück zum Zitat Stiehl J, Abbott B. Morphology of the transepicondylar axis and its application in primary and revision total knee arthroplasty. J Arthroplasty. 1995;10:785–789.PubMedCrossRef Stiehl J, Abbott B. Morphology of the transepicondylar axis and its application in primary and revision total knee arthroplasty. J Arthroplasty. 1995;10:785–789.PubMedCrossRef
37.
Zurück zum Zitat Stiehl J, Cherveny P. Femoral rotational alignment using the tibial shaft axis in total knee arthroplasty. Clin Orthop Relat Res. 1996;331:47–55.PubMedCrossRef Stiehl J, Cherveny P. Femoral rotational alignment using the tibial shaft axis in total knee arthroplasty. Clin Orthop Relat Res. 1996;331:47–55.PubMedCrossRef
38.
Zurück zum Zitat Stockl B, Nogler M, Rosiek R, Fischer M, Krismer M, Kessler O. Navigation improves accuracy of rotational alignment in total knee arthroplasty. Clin Orthop Relat Res. 2004;426:180–186.PubMedCrossRef Stockl B, Nogler M, Rosiek R, Fischer M, Krismer M, Kessler O. Navigation improves accuracy of rotational alignment in total knee arthroplasty. Clin Orthop Relat Res. 2004;426:180–186.PubMedCrossRef
39.
Zurück zum Zitat Whiteside L, Arima J. The anterior-posterior axis for femoral rotational alignment in valgus total knee arthroplasty. Clin Orthop Relat Res. 1995;321:168–172.PubMed Whiteside L, Arima J. The anterior-posterior axis for femoral rotational alignment in valgus total knee arthroplasty. Clin Orthop Relat Res. 1995;321:168–172.PubMed
Metadaten
Titel
Determining Femoral Component Position Using CAS and Measured Resection
verfasst von
James Benjamin, MD
Publikationsdatum
01.11.2008
Verlag
Springer-Verlag
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 11/2008
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-008-0426-x

Weitere Artikel der Ausgabe 11/2008

Clinical Orthopaedics and Related Research® 11/2008 Zur Ausgabe

Symposium: Papers Presented at the Annual Meetings of the Knee Society

Long-term Results With a Lateral Unicondylar Replacement

Symposium: Papers Presented at the Annual Meetings of the Knee Society

Does Patellar Eversion in Total Knee Arthroplasty Cause Patella Baja?

Symposium: Papers Presented at the Annual Meetings of the Knee Society

Rotating Platform versus Fixed-bearing Total Knees: An In Vitro Study of Wear

Symposium: Papers Presented at the Annual Meetings of the Knee Society

Posterior Cruciate-retaining Total Knee Arthroplasty for Valgus Osteoarthritis

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.