Skip to main content
Erschienen in: Clinical Orthopaedics and Related Research® 2/2012

01.02.2012 | Symposium: Papers Presented at the Annual Meetings of The Hip Society

Pelvic Discontinuity Treated With Custom Triflange Component: A Reliable Option

verfasst von: Michael J. Taunton, MD, Thomas K. Fehring, MD, Paul Edwards, MD, Thomas Bernasek, MD, Ginger E. Holt, MD, Michael J. Christie, MD

Erschienen in: Clinical Orthopaedics and Related Research® | Ausgabe 2/2012

Einloggen, um Zugang zu erhalten

Abstract

Background

Pelvic discontinuity is an increasingly common complication of THA. Treatments of this complex situation are varied, including cup-cage constructs, acetabular allografts with plating, pelvic distraction technique, and custom triflange acetabular components. It is unclear whether any of these offer substantial advantages.

Questions/purposes

We therefore determined (1) revision and overall survival rates, (2) discontinuity healing rate, and (3) Harris hip score (HHS) after treatment of pelvic discontinuity with a custom triflange acetabular component and (4) the cost of this reconstructive operation compared to other constructs.

Methods

We retrospectively reviewed 57 patients with pelvic discontinuity treated with revision THA using a custom triflange acetabular component. We reviewed operative reports, radiographs, and clinical data for clinical and radiographic results. We also performed a cost comparison with utilization of other techniques. Minimum followup was 24 months (average, 65 months; range, 24–215 months).

Results

Fifty-six of 57 (98%) were free of revision for aseptic loosening at latest followup. Fifty-four (95%) were free of revision of the triflange component for any reason. Thirty-seven (65%) were free of revision for any reason. Twenty-eight (49%) were free of revision for any reason and free of any component migration and had a healed discontinuity. Forty-six (81%) had a stable triflange component with a healed pelvic discontinuity. Average HHS was 74.8. The costs of the custom triflange implants and a Trabecular Metal® cup-cage construct were equivalent: $12,500 and $11,250, respectively.

Conclusions

In this group of patients with osteolytic pelvic discontinuity, triflange implants provided predictable mid-term fixation at a cost equivalent to other treatment methods.

Level of Evidence

Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Literatur
1.
Zurück zum Zitat Ballester Alfaro JJ, Sueiro Fernandez J. Trabecular metal buttress augment and the trabecular metal cup-cage construct in revision hip arthroplasty for severe acetabular bone loss and pelvic discontinuity. Hip Int. 2010;20:119–127.PubMed Ballester Alfaro JJ, Sueiro Fernandez J. Trabecular metal buttress augment and the trabecular metal cup-cage construct in revision hip arthroplasty for severe acetabular bone loss and pelvic discontinuity. Hip Int. 2010;20:119–127.PubMed
2.
Zurück zum Zitat Berry DJ, Lewallen DG, Hanssen AD, Cabanela ME. Pelvic discontinuity in revision total hip arthroplasty. J Bone Joint Surg Am. 1999;81:1692–1702.PubMed Berry DJ, Lewallen DG, Hanssen AD, Cabanela ME. Pelvic discontinuity in revision total hip arthroplasty. J Bone Joint Surg Am. 1999;81:1692–1702.PubMed
3.
Zurück zum Zitat Christie MJ, Barrington SA, Brinson MF, Ruhling ME, DeBoer DK. Bridging massive acetabular defects with the triflange cup: 2- to 9-year results. Clin Orthop Relat Res. 2001;393:216–227.PubMedCrossRef Christie MJ, Barrington SA, Brinson MF, Ruhling ME, DeBoer DK. Bridging massive acetabular defects with the triflange cup: 2- to 9-year results. Clin Orthop Relat Res. 2001;393:216–227.PubMedCrossRef
4.
Zurück zum Zitat D’Antonio JA, Capello WN, Borden LS, Bargar WL, Bierbaum BF, Boettcher WG, Steinberg ME, Stulberg SD, Wedge JH. Classification and management of acetabular abnormalities in total hip arthroplasty. Clin Orthop Relat Res. 1989;243:126–137.PubMed D’Antonio JA, Capello WN, Borden LS, Bargar WL, Bierbaum BF, Boettcher WG, Steinberg ME, Stulberg SD, Wedge JH. Classification and management of acetabular abnormalities in total hip arthroplasty. Clin Orthop Relat Res. 1989;243:126–137.PubMed
5.
Zurück zum Zitat DeBoer DK, Christie MJ, Brinson MF, Morrison JC. Revision total hip arthroplasty for pelvic discontinuity. J Bone Joint Surg Am. 2007;89:835–840.PubMedCrossRef DeBoer DK, Christie MJ, Brinson MF, Morrison JC. Revision total hip arthroplasty for pelvic discontinuity. J Bone Joint Surg Am. 2007;89:835–840.PubMedCrossRef
6.
Zurück zum Zitat De Jong RN. The Neurologic Examination: Incorporating the Fundamentals of Neuroanatomy and Neurophysiology. Hagerstown, MD: Harper & Row; 1979. De Jong RN. The Neurologic Examination: Incorporating the Fundamentals of Neuroanatomy and Neurophysiology. Hagerstown, MD: Harper & Row; 1979.
7.
Zurück zum Zitat Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969;51:737–755.PubMed Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969;51:737–755.PubMed
8.
Zurück zum Zitat Holt GE, Dennis DA. Use of custom triflanged acetabular components in revision total hip arthroplasty. Clin Orthop Relat Res. 2004;429:209–214.PubMedCrossRef Holt GE, Dennis DA. Use of custom triflanged acetabular components in revision total hip arthroplasty. Clin Orthop Relat Res. 2004;429:209–214.PubMedCrossRef
9.
Zurück zum Zitat Joshi AB, Lee J, Christensen C. Results for a custom acetabular component for acetabular deficiency. J Arthroplasty. 2002;17:643–648.PubMedCrossRef Joshi AB, Lee J, Christensen C. Results for a custom acetabular component for acetabular deficiency. J Arthroplasty. 2002;17:643–648.PubMedCrossRef
10.
Zurück zum Zitat Kosashvili Y, Backstein D, Safir O, Lakstein D, Gross AE. Acetabular revision using an anti-protrusion (ilio-ischial) cage and trabecular metal acetabular component for severe acetabular bone loss associated with pelvic discontinuity. J Bone Joint Surg Br. 2009;91:870–876.PubMedCrossRef Kosashvili Y, Backstein D, Safir O, Lakstein D, Gross AE. Acetabular revision using an anti-protrusion (ilio-ischial) cage and trabecular metal acetabular component for severe acetabular bone loss associated with pelvic discontinuity. J Bone Joint Surg Br. 2009;91:870–876.PubMedCrossRef
11.
Zurück zum Zitat Massin P, Schmidt L, Engh CA. Evaluation of cementless acetabular component migration: an experimental study. J Arthroplasty. 1989;4:245–251.PubMedCrossRef Massin P, Schmidt L, Engh CA. Evaluation of cementless acetabular component migration: an experimental study. J Arthroplasty. 1989;4:245–251.PubMedCrossRef
12.
Zurück zum Zitat Morrey BF. Joint Replacement Arthroplasty. New York, NY: Churchill Livingstone; 2003. Morrey BF. Joint Replacement Arthroplasty. New York, NY: Churchill Livingstone; 2003.
13.
Zurück zum Zitat Paprosky WG, O’Rourke M, Sporer SM. The treatment of acetabular bone defects with an associated pelvic discontinuity. Clin Orthop Relat Res. 2005;441:216–220.PubMedCrossRef Paprosky WG, O’Rourke M, Sporer SM. The treatment of acetabular bone defects with an associated pelvic discontinuity. Clin Orthop Relat Res. 2005;441:216–220.PubMedCrossRef
14.
Zurück zum Zitat Robertson DD, Sutherland CJ, Lopes T, Yuan J. Preoperative description of severe acetabular defects caused by failed total hip replacement. J Comput Assist Tomogr. 1998;22:444–449.PubMedCrossRef Robertson DD, Sutherland CJ, Lopes T, Yuan J. Preoperative description of severe acetabular defects caused by failed total hip replacement. J Comput Assist Tomogr. 1998;22:444–449.PubMedCrossRef
15.
Zurück zum Zitat Sporer SM, Paprosky WG. Acetabular revision using a trabecular metal acetabular component for severe acetabular bone loss associated with a pelvic discontinuity. J Arthroplasty. 2006;21:87–90.PubMedCrossRef Sporer SM, Paprosky WG. Acetabular revision using a trabecular metal acetabular component for severe acetabular bone loss associated with a pelvic discontinuity. J Arthroplasty. 2006;21:87–90.PubMedCrossRef
16.
Zurück zum Zitat Stiehl JB, Saluja R, Diener T. Reconstruction of major column defects and pelvic discontinuity in revision total hip arthroplasty. J Arthroplasty. 2000;15:849–857.PubMedCrossRef Stiehl JB, Saluja R, Diener T. Reconstruction of major column defects and pelvic discontinuity in revision total hip arthroplasty. J Arthroplasty. 2000;15:849–857.PubMedCrossRef
Metadaten
Titel
Pelvic Discontinuity Treated With Custom Triflange Component: A Reliable Option
verfasst von
Michael J. Taunton, MD
Thomas K. Fehring, MD
Paul Edwards, MD
Thomas Bernasek, MD
Ginger E. Holt, MD
Michael J. Christie, MD
Publikationsdatum
01.02.2012
Verlag
Springer-Verlag
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 2/2012
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-011-2126-1

Weitere Artikel der Ausgabe 2/2012

Clinical Orthopaedics and Related Research® 2/2012 Zur Ausgabe

Symposium: Papers Presented at the Annual Meetings of The Hip Society

Is an Algorithmic Approach to the Treatment of Recurrent Dislocation After THA Effective?

Symposium: Papers Presented at the Annual Meetings of The Hip Society

A Short Tapered Stem Reduces Intraoperative Complications in Primary Total Hip Arthroplasty

Symposium: Papers Presented at the Annual Meetings of The Hip Society

Ceramic Bearings for Total Hip Arthroplasty Have High Survivorship at 10 Years

Symposium: Papers Presented at the Annual Meetings of The Hip Society

Surgical Technique: A Cup-in-Cup Technique to Restore Offset in Severe Protrusio Acetabular Defects

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.