Skip to main content
Erschienen in: Annals of Nuclear Medicine 8/2010

01.10.2010 | Original Article

A simple table lookup method for PET/CT partial volume correction using a point-spread function in diagnosing lymph node metastasis

verfasst von: Yuichi Sakaguchi, Noriko Mizoguchi, Tatsuya Mitsumoto, Katsuhiko Mitsumoto, Kazuhiko Himuro, Nobuyoshi Ohya, Koichiro Kaneko, Shingo Baba, Koichiro Abe, Yoshihiko Onizuka, Masayuki Sasaki

Erschienen in: Annals of Nuclear Medicine | Ausgabe 8/2010

Einloggen, um Zugang zu erhalten

Abstract

Objective

We evaluated the partial volume effect in PET/CT images and developed a simple correction method to address this problem.

Methods

Six spheres and the background in the phantom were filled with F-18 and we thus obtained 4 different sphere-to-background (SB) ratios. Thirty-nine cervical lymph nodes in 7 patients with papillary thyroid carcinoma (15 malignant and 24 benign) were also examined as a preliminary clinical study. First, we developed recovery coefficient (RC) curves normalized to the maximum counts of the 37-mm sphere. Next, we developed a correction table to determine the true SB ratio using three parameters, including the maximum counts of both the sphere and background and the lesion diameter, by modifying the approximation formula of the RC curves including the point-spread function correction. The full width at half maximum in this formula is estimated with the function of the SB ratio.

Results

In the phantom study, a size-dependent underestimation of the radioactivity was observed. The degree of decline of RC was influenced by the SB ratio. In preliminary clinical examination, the difference in the SUVmax between malignant and benign LNs thus became more prominent after the correction. The PV correction slightly improved the diagnostic accuracy from 95 to 100%.

Conclusions

We developed a simple table lookup correction method for the partial volume effect of PET/CT. This new method is considered to be clinically useful for the diagnosis of cervical LN metastasis. Further examination with a greater number of subjects is required to corroborate its clinical usefulness.
Literatur
1.
Zurück zum Zitat Poeppel TD, Krause BJ, Heusner TA, Boy C, Bockisch A, Antoch G. PET/CT for the staging and follow-up of patients with malignancies. Eur J Radiol. 2009;70(3):382–92.CrossRefPubMed Poeppel TD, Krause BJ, Heusner TA, Boy C, Bockisch A, Antoch G. PET/CT for the staging and follow-up of patients with malignancies. Eur J Radiol. 2009;70(3):382–92.CrossRefPubMed
2.
Zurück zum Zitat Sasaki M, Ichiya Y, Kuwabara Y, Akashi Y, Yoshida T, Fukumura T, et al. The usefulness of FDG positron emission tomography for the detection of mediastinal lymph node metastases in patients with non-small cell lung cancer: a comparative study with X-ray computed tomography. Eur J Nucl Med. 1996;23:741–7.CrossRefPubMed Sasaki M, Ichiya Y, Kuwabara Y, Akashi Y, Yoshida T, Fukumura T, et al. The usefulness of FDG positron emission tomography for the detection of mediastinal lymph node metastases in patients with non-small cell lung cancer: a comparative study with X-ray computed tomography. Eur J Nucl Med. 1996;23:741–7.CrossRefPubMed
3.
Zurück zum Zitat Gould MK, Kuschner WG, Rydzak CE, Maclean CC, Demas AN, Shigemitsu H, et al. Test performance of positron emission tomography and computed tomography for mediastinal staging in patients with non-small-cell lung cancer: a meta-analysis. Ann Intern Med. 2003;139(11):879–92.PubMed Gould MK, Kuschner WG, Rydzak CE, Maclean CC, Demas AN, Shigemitsu H, et al. Test performance of positron emission tomography and computed tomography for mediastinal staging in patients with non-small-cell lung cancer: a meta-analysis. Ann Intern Med. 2003;139(11):879–92.PubMed
4.
Zurück zum Zitat Kyzas PA, Evangelou E, Denaxa-Kyza D, Ioannidis JP. 18F-Fluorodeoxyglucose positron emission tomography to evaluate cervical node metastases in patients with head and neck squamous cell carcinoma: a meta-analysis. J Natl Cancer Inst. 2008;100(10):712–20.CrossRefPubMed Kyzas PA, Evangelou E, Denaxa-Kyza D, Ioannidis JP. 18F-Fluorodeoxyglucose positron emission tomography to evaluate cervical node metastases in patients with head and neck squamous cell carcinoma: a meta-analysis. J Natl Cancer Inst. 2008;100(10):712–20.CrossRefPubMed
5.
Zurück zum Zitat Rousset OG, Ma Y, Evans AC. Correction for partial volume effects in PET: principle and validation. J Nucl Med. 1998;39:904–11.PubMed Rousset OG, Ma Y, Evans AC. Correction for partial volume effects in PET: principle and validation. J Nucl Med. 1998;39:904–11.PubMed
6.
Zurück zum Zitat Rousset OG, Collins DL, Rahmim A, Wong DF. Design and implementation of an automated partial volume correction in PET: application to dopamine receptor quantification in the normal human striatum. J Nucl Med. 2008;49:1097–106.CrossRefPubMed Rousset OG, Collins DL, Rahmim A, Wong DF. Design and implementation of an automated partial volume correction in PET: application to dopamine receptor quantification in the normal human striatum. J Nucl Med. 2008;49:1097–106.CrossRefPubMed
7.
Zurück zum Zitat Chen CH, Muzic RF Jr, Nelson AD, Adler LP. Simultaneous recovery of size and radioactivity concentration of small spheroids with PET data. J Nucl Med. 1999;40:118–30.PubMed Chen CH, Muzic RF Jr, Nelson AD, Adler LP. Simultaneous recovery of size and radioactivity concentration of small spheroids with PET data. J Nucl Med. 1999;40:118–30.PubMed
8.
Zurück zum Zitat Adler LP, Crowe JP, Al-Kaisi NK, Sunshine JL. Evaluation of breast masses and axillary lymph nodes with [F-18] 2-deoxy-2-fluoro-d-glucose PET. Radiology. 1993;187:743–50.PubMed Adler LP, Crowe JP, Al-Kaisi NK, Sunshine JL. Evaluation of breast masses and axillary lymph nodes with [F-18] 2-deoxy-2-fluoro-d-glucose PET. Radiology. 1993;187:743–50.PubMed
9.
Zurück zum Zitat Geworski L, Knoop BO, de Cabrejas ML, Knapp WH, Munz DL. Recovery correction for quantitation in emission tomography: a feasibility study. Eur J Nucl Med. 2000;27(2):161–9.CrossRefPubMed Geworski L, Knoop BO, de Cabrejas ML, Knapp WH, Munz DL. Recovery correction for quantitation in emission tomography: a feasibility study. Eur J Nucl Med. 2000;27(2):161–9.CrossRefPubMed
10.
Zurück zum Zitat Hickeson M, Yun M, Matthies A, Zhuang H, Adam LE, Lacorte L, Alavi A. Use of a corrected standardized uptake value based on the lesion size on CT permits accurate characterization of lung nodules on FDG-PET. Eur J Nucl Med Mol Imaging. 2002;29(12):1639–47.CrossRefPubMed Hickeson M, Yun M, Matthies A, Zhuang H, Adam LE, Lacorte L, Alavi A. Use of a corrected standardized uptake value based on the lesion size on CT permits accurate characterization of lung nodules on FDG-PET. Eur J Nucl Med Mol Imaging. 2002;29(12):1639–47.CrossRefPubMed
11.
Zurück zum Zitat Srinivas SM, Dhurairaj T, Basu S, Bural G, Surti S, Alavi A. A recovery coefficient method for partial volume correction of PET images. Ann Nucl Med. 2009;23(4):341–8.CrossRefPubMed Srinivas SM, Dhurairaj T, Basu S, Bural G, Surti S, Alavi A. A recovery coefficient method for partial volume correction of PET images. Ann Nucl Med. 2009;23(4):341–8.CrossRefPubMed
12.
Zurück zum Zitat Hoffman EJ, Huang SC, Phelps ME. Quantitation in positron emission computed tomography: 1. Effect of object size. J Comput Assist Tomogr. 1979;3:299–308.CrossRefPubMed Hoffman EJ, Huang SC, Phelps ME. Quantitation in positron emission computed tomography: 1. Effect of object size. J Comput Assist Tomogr. 1979;3:299–308.CrossRefPubMed
13.
Zurück zum Zitat Kessler RM, Ellis JR Jr, Eden M. Analysis of emission tomographic scan data: limitations imposed by resolution and background. J Comput Assist Tomogr. 1984;8:514–22.CrossRefPubMed Kessler RM, Ellis JR Jr, Eden M. Analysis of emission tomographic scan data: limitations imposed by resolution and background. J Comput Assist Tomogr. 1984;8:514–22.CrossRefPubMed
14.
Zurück zum Zitat Soret M, Bacharach SL, Buvat I. Partial-volume effect in PET tumor imaging. J Nucl Med. 2007;48(6):932–45.CrossRefPubMed Soret M, Bacharach SL, Buvat I. Partial-volume effect in PET tumor imaging. J Nucl Med. 2007;48(6):932–45.CrossRefPubMed
15.
Zurück zum Zitat Sigg MB, Steinert H, Grätz K, Hugenin P, Stoeckli S, Eyrich GK. Staging of head and neck tumors: [18F]fluorodeoxyglucose positron emission tomography compared with physical examination and conventional imaging modalities. J Oral Maxillofac Surg. 2003;61(9):1022–9.CrossRefPubMed Sigg MB, Steinert H, Grätz K, Hugenin P, Stoeckli S, Eyrich GK. Staging of head and neck tumors: [18F]fluorodeoxyglucose positron emission tomography compared with physical examination and conventional imaging modalities. J Oral Maxillofac Surg. 2003;61(9):1022–9.CrossRefPubMed
Metadaten
Titel
A simple table lookup method for PET/CT partial volume correction using a point-spread function in diagnosing lymph node metastasis
verfasst von
Yuichi Sakaguchi
Noriko Mizoguchi
Tatsuya Mitsumoto
Katsuhiko Mitsumoto
Kazuhiko Himuro
Nobuyoshi Ohya
Koichiro Kaneko
Shingo Baba
Koichiro Abe
Yoshihiko Onizuka
Masayuki Sasaki
Publikationsdatum
01.10.2010
Verlag
Springer Japan
Erschienen in
Annals of Nuclear Medicine / Ausgabe 8/2010
Print ISSN: 0914-7187
Elektronische ISSN: 1864-6433
DOI
https://doi.org/10.1007/s12149-010-0401-y

Weitere Artikel der Ausgabe 8/2010