Skip to main content
Erschienen in: Annals of Nuclear Medicine 9/2012

01.11.2012 | Original article

Intra-reader reliability of FDG PET volumetric tumor parameters: effects of primary tumor size and segmentation methods

verfasst von: B. Shah, N. Srivastava, A. E. Hirsch, G. Mercier, R. M. Subramaniam

Erschienen in: Annals of Nuclear Medicine | Ausgabe 9/2012

Einloggen, um Zugang zu erhalten

Abstract

Objective

To establish the effects of size and segmentation methods on intra-reader reliability of primary tumor metabolic tumor volume (MTV) and total glycolytic activity (TGA) in human solid tumors.

Methods

This is a retrospective study of 121 patients who had a baseline FDG PET/CT scan for oncologic staging. Volumetric parameter readings were performed in random order on two separate occasions, 12 weeks apart, by the same reader. The MTV and TGA were segmented using gradient and fixed maximum standardized uptake value (SUVmax) threshold methods. Intra-reader reliability was established by the intraclass correlation coefficient (ICC) and Bland–Altman analysis.

Results

The biases for MTV were 2.95, 14.76 and 11.13 % for gradient segmentation, 38 and 50 % SUVmax fixed threshold segmentations, respectively (p < 0.0001). For TGA, the corresponding biases were 0.76, 10.36 and 7.46 % (p < 0.0001). There were no statistically significant differences in the biases between the first and second reads for MTV segmented for small and large volume tumors by the gradient method (p < 0.34) or 50 % SUVmax threshold segmentation (p < 0.08). However, there were statistically significant differences in the corresponding biases for the 38 % SUVmax threshold segmentation (p < 0.04). There were no statistically significant differences in the biases between the first and second reads for TGA segmented for small and large volume tumors (p < 0.98).

Conclusion

Intra-reader reliability for primary tumor FDG MTV and TGA is affected by the tumor size and segmentation methods. The segmentation bias was smaller for gradient method than percentage fixed threshold method for MTV. The segmentation biases were smaller for TGA than MTV.
Literatur
1.
Zurück zum Zitat Sullivan DC, Gatsonis C. Response to treatment series: part 1 and introduction, measuring tumor response–challenges in the era of molecular medicine. AJR Am J Roentgenol. 2011;197:15–7.PubMedCrossRef Sullivan DC, Gatsonis C. Response to treatment series: part 1 and introduction, measuring tumor response–challenges in the era of molecular medicine. AJR Am J Roentgenol. 2011;197:15–7.PubMedCrossRef
2.
Zurück zum Zitat Subramaniam RM, Truong M, Peller P, Sakai O, Mercier G. Fluorodeoxyglucose-positron-emission tomography imaging of head and neck squamous cell cancer. AJNR Am J Neuroradiol. 2010;31:598–604.PubMedCrossRef Subramaniam RM, Truong M, Peller P, Sakai O, Mercier G. Fluorodeoxyglucose-positron-emission tomography imaging of head and neck squamous cell cancer. AJNR Am J Neuroradiol. 2010;31:598–604.PubMedCrossRef
3.
Zurück zum Zitat Davison JM, Ozonoff A, Imsande HM, Grillone GA, Subramaniam RM. Squamous cell carcinoma of the palatine tonsils: FDG standardized uptake value ratio as a biomarker to differentiate tonsillar carcinoma from physiologic uptake. Radiology. 2010;255:578–85.PubMedCrossRef Davison JM, Ozonoff A, Imsande HM, Grillone GA, Subramaniam RM. Squamous cell carcinoma of the palatine tonsils: FDG standardized uptake value ratio as a biomarker to differentiate tonsillar carcinoma from physiologic uptake. Radiology. 2010;255:578–85.PubMedCrossRef
4.
Zurück zum Zitat Karantanis D, Bogsrud TV, Wiseman GA, Mullan BP, Subramaniam RM, Nathan MA, et al. Clinical significance of diffusely increased 18F-FDG uptake in the thyroid gland. J Nucl Med. 2007;48:896–901.PubMedCrossRef Karantanis D, Bogsrud TV, Wiseman GA, Mullan BP, Subramaniam RM, Nathan MA, et al. Clinical significance of diffusely increased 18F-FDG uptake in the thyroid gland. J Nucl Med. 2007;48:896–901.PubMedCrossRef
5.
Zurück zum Zitat Karantanis D, Subramaniam RM, Witte RJ, Mullan BP, Nathan MA, et al. 18F-FDG PET/CT in primary central nervous system lymphoma in HIV-negative patients. Nucl Med Commun. 2007;28:834–41.PubMedCrossRef Karantanis D, Subramaniam RM, Witte RJ, Mullan BP, Nathan MA, et al. 18F-FDG PET/CT in primary central nervous system lymphoma in HIV-negative patients. Nucl Med Commun. 2007;28:834–41.PubMedCrossRef
6.
Zurück zum Zitat Karantanis D, Subramaniam RM, Peller PJ, Lowe VJ, Durski JM, Collins DA, et al. The value of [(18)F]fluorodeoxyglucose positron emission tomography/computed tomography in extranodal natural killer/T-cell lymphoma. Clin Lymphoma Myeloma. 2008;8:94–9.PubMedCrossRef Karantanis D, Subramaniam RM, Peller PJ, Lowe VJ, Durski JM, Collins DA, et al. The value of [(18)F]fluorodeoxyglucose positron emission tomography/computed tomography in extranodal natural killer/T-cell lymphoma. Clin Lymphoma Myeloma. 2008;8:94–9.PubMedCrossRef
7.
Zurück zum Zitat Imsande HM, Davison JM, Truong MT, Devaiah AK, Mercier G, Ozonoff Al, et al. Use of 18F-FDG PET/CT as a predictive biomarker of outcome in patients with head-and-neck non-squamous cell carcinoma. AJR Am J Roentgenol. 2011;197(4):976–80.PubMedCrossRef Imsande HM, Davison JM, Truong MT, Devaiah AK, Mercier G, Ozonoff Al, et al. Use of 18F-FDG PET/CT as a predictive biomarker of outcome in patients with head-and-neck non-squamous cell carcinoma. AJR Am J Roentgenol. 2011;197(4):976–80.PubMedCrossRef
8.
Zurück zum Zitat Seol YM, Kwon BR, Song MK, Choi YJ, Shin HJ, Chung JS, et al. Measurement of tumor volume by PET to evaluate prognosis in patients with head and neck cancer treated by chemo-radiation therapy. Acta Oncol. 2010;49:201–8.PubMedCrossRef Seol YM, Kwon BR, Song MK, Choi YJ, Shin HJ, Chung JS, et al. Measurement of tumor volume by PET to evaluate prognosis in patients with head and neck cancer treated by chemo-radiation therapy. Acta Oncol. 2010;49:201–8.PubMedCrossRef
9.
Zurück zum Zitat Lee HY, Hyun SH, Lee KS, Kim BT, Kim J, Shim YM, et al. Volume-based parameter of 18F-FDG PET/CT in malignant pleural mesothelioma: prediction of therapeutic response and prognostic implications. Ann Surg Oncol. 2010;17:2787–94.PubMedCrossRef Lee HY, Hyun SH, Lee KS, Kim BT, Kim J, Shim YM, et al. Volume-based parameter of 18F-FDG PET/CT in malignant pleural mesothelioma: prediction of therapeutic response and prognostic implications. Ann Surg Oncol. 2010;17:2787–94.PubMedCrossRef
10.
Zurück zum Zitat Hatt M, Cheze Le Rest C, Albarghach N, Pradier O, Visvikis D. PET functional volume delineation: a robustness and repeatability study. Eur J Nucl Med Mol Imaging. 2011;38:663–72.PubMedCrossRef Hatt M, Cheze Le Rest C, Albarghach N, Pradier O, Visvikis D. PET functional volume delineation: a robustness and repeatability study. Eur J Nucl Med Mol Imaging. 2011;38:663–72.PubMedCrossRef
11.
Zurück zum Zitat Hatt M, Cheze-Le Rest C, Aboagye EO, Kenny LM, Rosso L, Turkheimer FE, et al. Reproducibility of 18F-FDG and 3′-deoxy-3′-18F-fluorothymidine PET tumor volume measurements. J Nucl Med. 2010;51:1368–76.PubMedCrossRef Hatt M, Cheze-Le Rest C, Aboagye EO, Kenny LM, Rosso L, Turkheimer FE, et al. Reproducibility of 18F-FDG and 3′-deoxy-3′-18F-fluorothymidine PET tumor volume measurements. J Nucl Med. 2010;51:1368–76.PubMedCrossRef
12.
Zurück zum Zitat Hyun SH, Choi JY, Shim YM, Kim K, Lee SJ, Cho YS, et al. Prognostic value of metabolic tumor volume measured by 18F-fluorodeoxyglucose positron emission tomography in patients with esophageal carcinoma. Ann Surg Oncol. 2010;17(1):115–22.PubMedCrossRef Hyun SH, Choi JY, Shim YM, Kim K, Lee SJ, Cho YS, et al. Prognostic value of metabolic tumor volume measured by 18F-fluorodeoxyglucose positron emission tomography in patients with esophageal carcinoma. Ann Surg Oncol. 2010;17(1):115–22.PubMedCrossRef
13.
Zurück zum Zitat La TH, Filion EJ, Turnbull BB, Chu JN, Lee P, Nguyen K, et al. Metabolic tumor volume predicts for recurrence and death in head-and-neck cancer. Int J Radiat Oncol Biol Phys. 2009;74:1335–41.PubMedCrossRef La TH, Filion EJ, Turnbull BB, Chu JN, Lee P, Nguyen K, et al. Metabolic tumor volume predicts for recurrence and death in head-and-neck cancer. Int J Radiat Oncol Biol Phys. 2009;74:1335–41.PubMedCrossRef
14.
Zurück zum Zitat Hadiprodjo D, Ryan T, Truong M, Mercier G, Subramaniam R. Parotid gland tumors: preliminary data for the value of FDG PET/CT diagnostic parameters. AJR (in press). 2011. Hadiprodjo D, Ryan T, Truong M, Mercier G, Subramaniam R. Parotid gland tumors: preliminary data for the value of FDG PET/CT diagnostic parameters. AJR (in press). 2011.
15.
Zurück zum Zitat Dibble E, Lara Alvarez A, Truong M, Mercier G, Cook E, Subramaniam RM. FDG metabolic tumor volume and total glycolytic activity: prognostic imaging biomarkers of oral and oropharyngeal squamous cell cancers. J Nucl Med. 2012;53:709–15.PubMedCrossRef Dibble E, Lara Alvarez A, Truong M, Mercier G, Cook E, Subramaniam RM. FDG metabolic tumor volume and total glycolytic activity: prognostic imaging biomarkers of oral and oropharyngeal squamous cell cancers. J Nucl Med. 2012;53:709–15.PubMedCrossRef
16.
Zurück zum Zitat Werner-Wasik M, Nelson AD, Choi W, Arai Y, Faulhaber PF, Kang P, et al. What is the best way to contour lung tumors on PET Scans? multiobserver validation of a gradient-based method using a NSCLC digital PET phantom. Int J Radiat Oncol Biol Phys. 2012;82:1164–71.PubMedCrossRef Werner-Wasik M, Nelson AD, Choi W, Arai Y, Faulhaber PF, Kang P, et al. What is the best way to contour lung tumors on PET Scans? multiobserver validation of a gradient-based method using a NSCLC digital PET phantom. Int J Radiat Oncol Biol Phys. 2012;82:1164–71.PubMedCrossRef
17.
Zurück zum Zitat Cheebsumon P, van Velden FH, Yaqub M, Frings V, de Langen AJ, Hoekstra OS, et al. Effects of image characteristics on performance of tumor delineation methods: a test–retest assessment. J Nucl Med. 2011;52:1550–8.PubMedCrossRef Cheebsumon P, van Velden FH, Yaqub M, Frings V, de Langen AJ, Hoekstra OS, et al. Effects of image characteristics on performance of tumor delineation methods: a test–retest assessment. J Nucl Med. 2011;52:1550–8.PubMedCrossRef
18.
Zurück zum Zitat Hatt M, Visvikis D, Le Rest CC. Autocontouring versus manual contouring. J Nucl Med. 2011;52:658.PubMedCrossRef Hatt M, Visvikis D, Le Rest CC. Autocontouring versus manual contouring. J Nucl Med. 2011;52:658.PubMedCrossRef
19.
Zurück zum Zitat MacManus M, Nestle U, Rosenzweig KE, Carrio I, Messa C, Belohlavek O, et al. Use of PET and PET/CT for radiation therapy planning: IAEA expert report 2006–2007. Radiother Oncol. 2009;91:85–94.PubMedCrossRef MacManus M, Nestle U, Rosenzweig KE, Carrio I, Messa C, Belohlavek O, et al. Use of PET and PET/CT for radiation therapy planning: IAEA expert report 2006–2007. Radiother Oncol. 2009;91:85–94.PubMedCrossRef
20.
Zurück zum Zitat Geets X, Lee JA, Bol A, Lonneux M, Gregoire V. A gradient-based method for segmenting FDG-PET images: methodology and validation. Eur J Nucl Med Mol Imaging. 2007;34:1427–38.PubMedCrossRef Geets X, Lee JA, Bol A, Lonneux M, Gregoire V. A gradient-based method for segmenting FDG-PET images: methodology and validation. Eur J Nucl Med Mol Imaging. 2007;34:1427–38.PubMedCrossRef
21.
Zurück zum Zitat Wanet M, Lee JA, Weynand B, De Bast M, Poncelet A, Lacroix V, et al. Gradient-based delineation of the primary GTV on FDG-PET in non-small cell lung cancer: a comparison with threshold-based approaches. CT and surgical specimens. Radiother Oncol. 2011;98:117–25.PubMedCrossRef Wanet M, Lee JA, Weynand B, De Bast M, Poncelet A, Lacroix V, et al. Gradient-based delineation of the primary GTV on FDG-PET in non-small cell lung cancer: a comparison with threshold-based approaches. CT and surgical specimens. Radiother Oncol. 2011;98:117–25.PubMedCrossRef
22.
Zurück zum Zitat Murphy JD, Chisholm KM, Daly ME, Wiegner EA, Truong D, Iagaru A, et al. Correlation between metabolic tumor volume and pathologic tumor volume in squamous cell carcinoma of the oral cavity. Radiother Oncol. 2011;101:356–61.PubMedCrossRef Murphy JD, Chisholm KM, Daly ME, Wiegner EA, Truong D, Iagaru A, et al. Correlation between metabolic tumor volume and pathologic tumor volume in squamous cell carcinoma of the oral cavity. Radiother Oncol. 2011;101:356–61.PubMedCrossRef
23.
Zurück zum Zitat Dewalle-Vignion AS, Yeni N, Petyt G, Verscheure L, Huglo D, Beron A, et al. Evaluation of PET volume segmentation methods: comparisons with expert manual delineations. Nucl Med Commun. 2012;33:34–42.PubMedCrossRef Dewalle-Vignion AS, Yeni N, Petyt G, Verscheure L, Huglo D, Beron A, et al. Evaluation of PET volume segmentation methods: comparisons with expert manual delineations. Nucl Med Commun. 2012;33:34–42.PubMedCrossRef
24.
Zurück zum Zitat Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33:159–74.PubMedCrossRef Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33:159–74.PubMedCrossRef
25.
Zurück zum Zitat Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307–10.PubMedCrossRef Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307–10.PubMedCrossRef
26.
Zurück zum Zitat Hatt M, Cheze-le Rest C, van Baardwijk A, Lambin P, Pradier O, Visvikis D. Impact of tumor size and tracer uptake heterogeneity in 18F-FDG PET and CT non-small cell lung cancer tumor delineation. J Nucl Med. 2011;52:1690–7.PubMedCrossRef Hatt M, Cheze-le Rest C, van Baardwijk A, Lambin P, Pradier O, Visvikis D. Impact of tumor size and tracer uptake heterogeneity in 18F-FDG PET and CT non-small cell lung cancer tumor delineation. J Nucl Med. 2011;52:1690–7.PubMedCrossRef
27.
Zurück zum Zitat Jackson T, Chung M, Ozonoff A, Mercier G, Subramaniam RM. FDG PET/CT inter-observer agreement in head and neck cancer: FDG and CT measurements of the primary tumor site. Nucl Med Commun. 2012;33:305–12.PubMedCrossRef Jackson T, Chung M, Ozonoff A, Mercier G, Subramaniam RM. FDG PET/CT inter-observer agreement in head and neck cancer: FDG and CT measurements of the primary tumor site. Nucl Med Commun. 2012;33:305–12.PubMedCrossRef
Metadaten
Titel
Intra-reader reliability of FDG PET volumetric tumor parameters: effects of primary tumor size and segmentation methods
verfasst von
B. Shah
N. Srivastava
A. E. Hirsch
G. Mercier
R. M. Subramaniam
Publikationsdatum
01.11.2012
Verlag
Springer Japan
Erschienen in
Annals of Nuclear Medicine / Ausgabe 9/2012
Print ISSN: 0914-7187
Elektronische ISSN: 1864-6433
DOI
https://doi.org/10.1007/s12149-012-0630-3

Weitere Artikel der Ausgabe 9/2012

Annals of Nuclear Medicine 9/2012 Zur Ausgabe