The validation of the visual analogue scale for patient satisfaction after total hip arthroplasty

verfasst von: Roy B. G. Brokelman, Daniel Haverkamp, Corné van Loon, Annemiek Hol, Albert van Kampen, Rene Veth

Erschienen in: European Orthopaedics and Traumatology | Ausgabe 2/2012

Abstract

Introduction

Patient satisfaction becomes more important in our modern health care system. The assessment of satisfaction is difficult because it is a multifactorial item for which no golden standard exists. One of the potential methods of measuring satisfaction is by using the well-known visual analogue scale (VAS). In this study, we validated VAS for satisfaction.

Patient and methods

In this prospective study, we studied 147 patients (153 hips). The construct validity was measured using the Spearman correlation test that compares the satisfaction VAS with the Harris hip score, pain VAS at rest and during activity, Oxford hip score, Short Form 36 and Western Ontario McMaster Universities Osteoarthritis Index. The reliability was tested using the intra-class coefficient.

Results

The Pearson correlation test showed correlations in the range of 0.40–0.80. The satisfaction VAS had a high correlation between the pain VAS and Oxford hip score, which could mean that pain is one of the most important factors in patient satisfaction. The intra-class coefficient was 0.95.

Conclusions

There is a moderate to mark degree of correlation between the satisfaction VAS and the currently available subjective and objective scoring systems. The intra-class coefficient of 0.95 indicates an excellent test–retest reliability. The VAS satisfaction is a simple instrument to quantify the satisfaction of a patient after total hip arthroplasty. In this study, we showed that the satisfaction VAS has a good validity and reliability.

Introduction

The World Health Organisation has directly tied health with patient satisfaction: “Health is not only the absence of infirmity and disease but also a state of physical, mental and social well-being.” Greater patient satisfaction reflects better quality of care, leading to better quality of life. The visual analogue scale (VAS) is a simple and frequently used method to evaluate variations in pain intensity [6]. The assessment of pain is difficult because it is a multifaceted expression of affective, cognitive, physical, sensory, behavioural, social–cultural and subjective feelings. Despite this diversity, the VAS pain is widely used in the literature and clinical practice. The same multifaceted difficulty is present in the rating of patient satisfaction after an arthroplasty. It is essential for providers of health care services, in particular doctors, to be able to demonstrate the efficacy of treatment [15, 17]. In orthopaedic surgery, the outcome of total joint arthroplasties is traditionally evaluated by objective clinical methods that are based on the assessment of pain and functional disability, scored by the orthopaedic surgeon [5, 9]. In our modern health care system, it is important to include the patient’s opinion in the quality outcome assessment of joint arthroplasty, since the patient is the most prominent participant [2, 16, 22]. In literature, there are no validated scoring systems to evaluate the satisfaction of the patients after an arthroplasty. A scoring system has to be simple to use and validated to be practical in a clinical setting. Haverkamp et al. showed in 2008 that a single question of Likert scale satisfaction questions lacks validity for hip arthroplasty patients [13]. The discussion whether in some questions a VAS or a Likert scale should be used was tackled in 1987 by Guyatt et al., showing a greater improvement in the VAS and a greater variability in the improvement on VAS compared to the Likert scale [11]. For satisfaction measurement, this could mean that a VAS system is perhaps more suitable. The satisfaction VAS has been used in recent literature, but the validation and reliability are unknown [4]. The goals of the present study were to assess the validity and reliability of the patients’ satisfaction VAS score after total hip arthroplasty.

Patients and methods

Between October 2003 and June 2005, 189 primary total hip arthroplasties (THAs) were carried out in 180 patients (122 women and 58 men) in our joint care project. At this time, the preoperative pain VAS at rest and during activity, the Western Ontario McMaster Universities osteoarthritis index (WOMAC) and Harris hip score (HHS) were obtained. The patients gave their informed consent for this prospective study. The average age at time of operation was 67.5 years (SD 9.2). Most hips were affected by primary OA (161), 15 hips by rheumatoid arthritis and 13 hips by osteonecrosis of the femoral head. Seventy patients (75 hips) received the Charnley Elite Plus total hip prosthesis (DePuy/Johnson & Johnson, Leeds, UK). One hundred and ten patients (114 hips) received the Zweymüller hip prosthesis (Zimmer, Winterthur, Switzerland). At an average follow-up of 2.5 years (SD 0.2), 4 patients (5 hips) had died, 4 patients (4 hips) were revised and 25 patients (27 hips) were excluded because they were not able to fill in the evaluation forms because of cognitive deficit or they were not able to come to the outpatient department. The latter 25 patients (27 hips) had no complaints of their THA and had had no revision surgery. One hundred and fifty-three hips in 147 patients were clinically and radiographically assessed in the outpatient department. The patients were contacted by phone, and the goal of our study was explained. Thereafter, we send them, 4 weeks before the appointment, an envelope containing the evaluation forms. The evaluation forms consist of the WOMAC form [3, 19], pain VAS at rest and during activity [7, 18], satisfaction VAS, the Short Form 36 (SF-36) [1, 14], HHS [12] and the Oxford hip score (OHS) [10]. At arrival at the outpatient department, we received the forms, and the patients were sent to the radiology department for an AP radiograph of the pelvis. In the waiting room of this department, the patients were asked to fill in another satisfaction VAS and a VAS pain at rest and during activity. An experienced and independent physical therapist (AH) took the forms at the outpatient department and verified if they were filled in correctly. Thereafter, she performed the history and clinical examination and completed the HHS [12].

Satisfaction visual analogue scale

A VAS for satisfaction is a horizontal line of 100-mm long. At the beginning and at the end, there are two descriptors representing extremes of satisfaction (i.e. no satisfaction and extreme satisfaction). The patient rated his satisfaction by making a vertical mark on the 100-mm line. The measurement in millimetres was converted to the same number of points ranging from 0 to 100 points. The exact question was “Are you satisfied with your hip prosthesis?” A standard explanation of how to fill in the VAS form was mentioned beneath the VAS horizontal line. The VAS form is shown in the annex.

Construct validity

In the absence of a golden standard, the construct validity should be considered with scores that correlate well with the satisfaction VAS to judge its validity. Construct validity of the satisfaction VAS is established by comparison with the relevant components of the SF-36, VAS pain during rest and activity, WOMAC, OHS and HHS by means of Spearman’s correlation analysis. Convergent and discriminant validities are two aspects of construct validity. Convergent validity refers to the extent to which different ways of measuring the same trait intercorrelate with one another. Discriminant validity involves demonstrating that a measure does not correlate too strongly with measures that are intended to indicate different traits than it does. To measure convergent and divergent validity, satisfaction is compared by means of Spearman’s correlation analysis against the physical and mental scores from the SF-36.

Content validity

One of the items of content validity is the presence of a floor or ceiling effect, meaning that patients score the lowest or highest possible score. Although in case of satisfaction a large ceiling effect may look as a perfect outcome of your surgery, it may make your score less usable since there is no possibility to discriminate between these patients based on this outcome alone and since ceiling effect of the VAS satisfaction, but also possible ceiling effects of the scores used for calculation of the construct validity can influence calculation of the construct validity. For all scores used, the ceiling effect is calculated.

Reliability

Reliability refers to the fact that the same outcome should be reached if the test is performed again by the same patients when the symptoms have not changed [8]. Reliability is the basic requirement of all scientific requirements [21]. The test–retest reliability of the satisfaction VAS was determined by giving the patients a second satisfaction VAS at the outpatient department after they had handed over the completed forms which they had filled in at home. The patients did not know that they had to fill out VAS forms for the second time. All patients confirmed that they had filled the first forms more than 2 days before they went to the outpatient department. The test–retest reliability was investigated by assessing the intra-class coefficient. The intra-class correlation coefficient (ranging between 0 and 1) is an index of concordance for continuous data. An intra-class correlation coefficient of less than 0.4 is considered poor; between 0.4 and 0.75, fair; and greater than 0.75, excellent [15]. The systematic difference between the initial and the retest satisfaction VAS test determines the reliability of the test.

Statistics

A priori power analyse on the outcome measure satisfaction indicated that with power set to 80 % and alpha set to 0.05, 150 patients were needed to validate the satisfaction VAS. The construct validity of the satisfaction VAS was tested using the Spearman rho correlation coefficients, which compare the patient satisfaction VAS with the pain VAS at rest and during activity, WOMAC, SF-36, HHS and the OHS and the improvement of the scores from preoperative to follow-up scores. The reliability was tested using the intra-class coefficients, which tested the test–retest of the satisfaction VAS. Significance was set at a p value <0.05.

Results

Patients

A total of 153 completed questionnaires were available from the follow-up. The patient satisfaction at the time of follow-up filled in at home was 85.6 (SD 25.1), and the patient satisfaction at the time of follow-up filled in at the outpatient department was 84.0 (SD 25.6). Not all patients showed an improvement in scores; the average improvements are shown in Table 1.
Table 1
Improvement after THA for the scores
 
Mean
Standard deviation
VAS pain in rest
26.4
28.2
VAS pain during activity
46.8
28.4
WOMAC pain
34.4
22.1
WOMAC stiffness
29.7
28.2
WOMAC functioning
32.1
24.4
Harris hip score
31.0
18.9

Construct validity

The Spearman rho compared to VAS pain varies from 0.62 to 0.80 which proves construct validity since pain is one of the most important factors in hip replacement. The construct validity compared to the WOMAC, Harris hip score and Oxford hip score are good with a rho varying between 0.53 and 0.70. Improvement compared to the preoperative status shows poor construct validity (Table 2). Convergent and divergent validity shows to be poor; both physical functioning and mental health of the SF-36 have a rho of 0.21 and 0.31 where only bodily pain scores a rho of 0.48.
Table 2
Construct validity, Spearman rho is shown for the VAS satisfaction against the different scores and their improvement
 
VAS satisfaction
Different scores
SF-36
Physical components
 Physical functioning (PF)
0.31
 Role limitation due to physical problems (RP)
0.40
 Bodily pain (BP)
0.48
 Social functioning (SF)
0.42
Mental components
 Mental health (MH)
0.21
 Role limitation due to emotional problems (RE)
0.11
 Energy and vitality (VT)
0.34
 General health (GH)
0.30
VAS pain rest
0.62
VAS pain activity
0.80
WOMAC
 Pain
0.59
 Function
0.53
 Physical functioning
0.461
 Oxford 12Q
0.67
 Harris hip score
0.70
 
 
Improvements
 VAS pain rest
0.35
 VAS pain activity
0.57
WOMAC
 Pain
0.40
 Function
0.45
 Physical functioning
0.54
 Harris hip score
0.55
For all correlation coefficients, p < 0.01

Content validity

A strong ceiling effect of the satisfaction VAS is present. Sixty-five patients (42 %) scored 100 on the VAS satisfaction, meaning very satisfied. The distribution of the VAS satisfaction is shown in Fig. 1. The amount of ceiling effect per score is given in Table 3.
Table 3
Ceiling effects per objective and subjective score
Oxford hip score
20.8 %
WOMAC pain
43.5 %
WOMAC stiffness
40.3 %
WOMAC physical
20.8 %
Harris hip score
7.1 %
VAS pain activitya
28.6 %
VAS pain resta
33.8 %
aFor VAS, a floor effect

Reliability

The test–retest, measured between the patient satisfaction VAS filled in at home and the patient satisfaction VAS filled in at the outpatient department, showed an intra-class coefficient of 0.95 (95 % CI 0.93–0.96).

Subanalysis

Because of the high ceiling effect, we performed a subanalysis for patients scoring 95 or less on the VAS satisfaction. Construct validity and reliability remained unchanged.

Discussion

Our goal was to assess validity and reliability of patient satisfaction administered by a visual analogue scale after total hip replacement. Our study shows good construct validity and poor content validity in the form of a high ceiling effect and good reliability for this VAS satisfaction scale in hip arthroplasty patients.
The main problem in assessing construct validity of a satisfaction score is the choice of scores to compare it with. Since the main indications for total hip arthroplasty are pain and limitations, we choose objective and subjective scoring systems (WOMAC, OHS, HHS and pain VAS at rest and during activity) to estimate construct validity. Although satisfaction is influenced by several widely differing events and complaints, for our population, pain seems to be the most suitable factor to calculate construct validity, since pain is the main indication to perform a hip arthroplasty.
Discriminant validity is also more difficult to assess since satisfaction is both influenced by physical and emotional factors. However, since we assumed in our population that physical factors would largely outweigh the emotional and psychological factors, we assessed divergent and convergent validity by comparing it to the relevant domains of the SF-36. This assumption appears to be false, since divergent and convergent validity shows to be poor using this method.
Our results show good to excellent construct validity when looking at the pain scores at follow-up with a rho varying between 0.62 and 0.80. These higher correlations were previously demonstrated between the disease-specific scores and domains of the general health questionnaires in other validation studies [9, 19, 21]. When looking at the improvement from preoperative to follow-up, these Spearman rho are much lower, indicating that satisfaction measured by a VAS scale is less suitable to postulate a statement over the amount of improvement over time but refers strongly to the current state the patient is in compared to his/her memory of the preoperative state.
One of our findings is a ceiling effect of 42 %. According to the criteria posted by Terwee et al., a ceiling effect of more than 15 % is not acceptable [20]. Previous study by Haverkamp et al. showed a ceiling effect of 79 % to be present in a Likert satisfaction scale for hip arthroplasty [13]. This indicates that for measuring satisfaction by means of a single question, the visual analogue score is clearly superior compared to a Likert scale. Although, it should be kept in mind that a ceiling effect is present for the satisfaction VAS. However, since satisfaction is not usable to measure the amount of improvement over time but gives a reflection of the patients’ well-being on that follow-up moment compared to the recollection of the preoperative status, a ceiling effect of 42 % does not render the satisfaction VAS as unusable. Furthermore, it should be noted that in our population, all scores used show a high ceiling effect, except for the Harris hip score. These high ceiling effects of all outcomes may influence calculation of construct and reliability; therefore, additional calculations were performed excluding the ceiling effects.
Reliability is usually measured by obtaining the same outcome under identical circumstances. In our study, we chose to obtain satisfaction both at home as well as on the outpatient clinic. One of the statements against using these single question satisfaction score is that the patients tend to score more satisfaction since they are more or less dependent of their surgeon for continuity of their treatment (never bite the hand that feeds you). Our test–retest reliability shows that it is not relevant where the satisfaction VAS is filled in and that obtaining it on the outpatient clinic is a reliable method.

Conclusions

In this study, we showed that the satisfaction VAS has a good validity and reliability, however with a ceiling effect of 42 %. The VAS satisfaction is a simple and valid instrument to quantify the satisfaction of a patient after a hip arthroplasty but cannot be used as the only outcome measurement. We conclude that the VAS satisfaction is probably a useful addition to subjective and objective outcome measurements in documenting the result of total hip arthroplasty.

Open Access

This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 2.0 International License (https://​creativecommons.​org/​licenses/​by/​2.​0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Orthopädie & Unfallchirurgie

Kombi-Abonnement

Mit e.Med Orthopädie & Unfallchirurgie erhalten Sie Zugang zu CME-Fortbildungen der Fachgebiete, den Premium-Inhalten der dazugehörigen Fachzeitschriften, inklusive einer gedruckten Zeitschrift Ihrer Wahl.

Literatur
1.
Zurück zum Zitat Aaronson NK, Muller M, Cohen PD, Essink-Bot ML, Fekkes M, Sanderman R, Sprangers MA, te Velde A, Verrips E (1998) Translation, validation, and norming of the Dutch language version of the SF-36 health survey in community and chronic disease populations. J Clin Epidemiol 51:1055–1068PubMedCrossRef Aaronson NK, Muller M, Cohen PD, Essink-Bot ML, Fekkes M, Sanderman R, Sprangers MA, te Velde A, Verrips E (1998) Translation, validation, and norming of the Dutch language version of the SF-36 health survey in community and chronic disease populations. J Clin Epidemiol 51:1055–1068PubMedCrossRef
2.
Zurück zum Zitat Amadio PC (1993) Outcomes measurement: more questions; some answers. J Bone Joint Surg 75-A:1583–1584 Amadio PC (1993) Outcomes measurement: more questions; some answers. J Bone Joint Surg 75-A:1583–1584
3.
Zurück zum Zitat Bellamy NW, Buchannan WW, Goldsmith CH, Cambell J, Stitt LW (1988) Validation study of WOMAC. J Rheumatol 15:1833–1840PubMed Bellamy NW, Buchannan WW, Goldsmith CH, Cambell J, Stitt LW (1988) Validation study of WOMAC. J Rheumatol 15:1833–1840PubMed
4.
Zurück zum Zitat Brokelman R, van Loon C, Rijnberg W (2003) Patient versus surgeon satisfaction after total hip arthroplasty. J Bone Joint Surg 85-B:495–498 Brokelman R, van Loon C, Rijnberg W (2003) Patient versus surgeon satisfaction after total hip arthroplasty. J Bone Joint Surg 85-B:495–498
5.
Zurück zum Zitat Bryant MJ, Kernohan WG, Nixon JR, Mollan RAB (1993) A statistical analysis of hip scores. J Bone Joint Surg 75-B:705–709 Bryant MJ, Kernohan WG, Nixon JR, Mollan RAB (1993) A statistical analysis of hip scores. J Bone Joint Surg 75-B:705–709
6.
Zurück zum Zitat Chapman CR, Casey KL, Dubner R, Foley KM, Gracely RH, Reading AE (1985) Pain measurement: an overview. Pain 22(1):1–31PubMedCrossRef Chapman CR, Casey KL, Dubner R, Foley KM, Gracely RH, Reading AE (1985) Pain measurement: an overview. Pain 22(1):1–31PubMedCrossRef
7.
Zurück zum Zitat Dolan P, Sutton M (1997) Mapping visual analogue scale health state valuations onto standard gamble and time trade-off values. Soc Sci Med 44:1519–1530PubMedCrossRef Dolan P, Sutton M (1997) Mapping visual analogue scale health state valuations onto standard gamble and time trade-off values. Soc Sci Med 44:1519–1530PubMedCrossRef
8.
Zurück zum Zitat Dunbar MJ, Robertsson O, Ryd L, Lidgren L (2001) Appropriate questionnaires for knee arthroplasty. Results of a survey of 3,600 patients from the Swedish Knee Arthroplasty Registry. J Bone Joint Surg 83-B:339–344CrossRef Dunbar MJ, Robertsson O, Ryd L, Lidgren L (2001) Appropriate questionnaires for knee arthroplasty. Results of a survey of 3,600 patients from the Swedish Knee Arthroplasty Registry. J Bone Joint Surg 83-B:339–344CrossRef
9.
Zurück zum Zitat Garellick G, Herberts P, Malchau H (1999) The value of clinical data scoring systems. J Arthroplasty 14:1024–1029PubMedCrossRef Garellick G, Herberts P, Malchau H (1999) The value of clinical data scoring systems. J Arthroplasty 14:1024–1029PubMedCrossRef
10.
Zurück zum Zitat Gosens T, Hoefnagels NH, de Vet RC, Dhert WJ, van Langelaan EJ, Bulstra SK, Geesink RG (2005) The “Oxford Heup Score”: the translation and validation of a questionnaire into Dutch to evaluate the results of total hip arthroplasty. Acta Orthop Scan 76(2):204–211CrossRef Gosens T, Hoefnagels NH, de Vet RC, Dhert WJ, van Langelaan EJ, Bulstra SK, Geesink RG (2005) The “Oxford Heup Score”: the translation and validation of a questionnaire into Dutch to evaluate the results of total hip arthroplasty. Acta Orthop Scan 76(2):204–211CrossRef
11.
Zurück zum Zitat Guyatt GH, Townsend M, Berman LB, Keller JL (1987) A comparison of Likert and visual analogue scales for measuring change in function. J Chronic Dis 40:1129–1133PubMedCrossRef Guyatt GH, Townsend M, Berman LB, Keller JL (1987) A comparison of Likert and visual analogue scales for measuring change in function. J Chronic Dis 40:1129–1133PubMedCrossRef
12.
Zurück zum Zitat Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fracture: treatment by mold arthroplasty. J Bone Joint Surg 51-A:737–755 Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fracture: treatment by mold arthroplasty. J Bone Joint Surg 51-A:737–755
13.
Zurück zum Zitat Haverkamp D, Sierevelt IN, van den Bekerom MP, Poolman RW, van Dijk CN, Marti RK (2008) The validity of patient satisfaction as single question in outcome measurement of total hip arthroplasty. J Long Term Eff Med Implants 18:145–150PubMed Haverkamp D, Sierevelt IN, van den Bekerom MP, Poolman RW, van Dijk CN, Marti RK (2008) The validity of patient satisfaction as single question in outcome measurement of total hip arthroplasty. J Long Term Eff Med Implants 18:145–150PubMed
14.
Zurück zum Zitat Katz JN, Larson MG, Phillips CB, Fossel AH, Liang MH (1992) Comparative measurement sensitivity of short and longer health status instruments. Med Care 30:917–925PubMedCrossRef Katz JN, Larson MG, Phillips CB, Fossel AH, Liang MH (1992) Comparative measurement sensitivity of short and longer health status instruments. Med Care 30:917–925PubMedCrossRef
15.
Zurück zum Zitat Knahr K, Kryspin-Exner I, Jagsch R, Freilinger W, Kasparek M (1998) Beurteilung der lebensqualität vor und nach implantation einer huft-totalendoprothese. Z Orthop 136:321–329PubMedCrossRef Knahr K, Kryspin-Exner I, Jagsch R, Freilinger W, Kasparek M (1998) Beurteilung der lebensqualität vor und nach implantation einer huft-totalendoprothese. Z Orthop 136:321–329PubMedCrossRef
16.
Zurück zum Zitat Lieberman JR, Dorey F, Shekelle P, Schumacher L et al (1996) Differences between patients’ and physicians’ evaluations of outcome after total hip arthroplasty. J Bone Joint Surg 78-A:835–838 Lieberman JR, Dorey F, Shekelle P, Schumacher L et al (1996) Differences between patients’ and physicians’ evaluations of outcome after total hip arthroplasty. J Bone Joint Surg 78-A:835–838
17.
Zurück zum Zitat Lingard E, Hashimoto H, Clement S (2000) Development of outcome research for total joint arthroplasty. J Orthop Sci 5:175–177PubMedCrossRef Lingard E, Hashimoto H, Clement S (2000) Development of outcome research for total joint arthroplasty. J Orthop Sci 5:175–177PubMedCrossRef
18.
Zurück zum Zitat Robinson A, Dolan P, Williams A (1997) Valuing health status using VAS and TTO. Soc Sci Med 45:1289–1297PubMedCrossRef Robinson A, Dolan P, Williams A (1997) Valuing health status using VAS and TTO. Soc Sci Med 45:1289–1297PubMedCrossRef
19.
Zurück zum Zitat Roorda L, Jones C, Waltz M et al (2004) Satisfactory cross cultural equivalence of the Dutch WOMAC in patients with hip osteoarthritis waiting for arthroplasty. Ann Rheum Dis 63:36–42PubMedCrossRef Roorda L, Jones C, Waltz M et al (2004) Satisfactory cross cultural equivalence of the Dutch WOMAC in patients with hip osteoarthritis waiting for arthroplasty. Ann Rheum Dis 63:36–42PubMedCrossRef
20.
Zurück zum Zitat Terwee CB, Bot SD, de Boer MR, van der Windt DA, Knol DL, Dekker J, Bouter LM, de Vet HC (2007) Quality criteria were proposed for measurement properties of health status questionnaires. J Clin Epidemiol 60:34–42PubMedCrossRef Terwee CB, Bot SD, de Boer MR, van der Windt DA, Knol DL, Dekker J, Bouter LM, de Vet HC (2007) Quality criteria were proposed for measurement properties of health status questionnaires. J Clin Epidemiol 60:34–42PubMedCrossRef
21.
Zurück zum Zitat Wright JG, Feinstein AR (1992) Improving the reliability of orthopaedic measurements. J Bone Joint Surg 74-B:287–291 Wright JG, Feinstein AR (1992) Improving the reliability of orthopaedic measurements. J Bone Joint Surg 74-B:287–291
22.
Zurück zum Zitat Wright JG, Young NL (1997) The patient-specific index: asking patients what they want. J Bone Joint Surg 79-A:974–983 Wright JG, Young NL (1997) The patient-specific index: asking patients what they want. J Bone Joint Surg 79-A:974–983
Metadaten
Titel
The validation of the visual analogue scale for patient satisfaction after total hip arthroplasty
verfasst von
Roy B. G. Brokelman
Daniel Haverkamp
Corné van Loon
Annemiek Hol
Albert van Kampen
Rene Veth
Publikationsdatum
01.06.2012
Verlag
Springer-Verlag
Erschienen in
European Orthopaedics and Traumatology / Ausgabe 2/2012
Print ISSN: 1867-4569
Elektronische ISSN: 1867-4577
DOI
https://doi.org/10.1007/s12570-012-0100-3

Weitere Artikel der Ausgabe 2/2012

European Orthopaedics and Traumatology 2/2012 Zur Ausgabe

Editorial

Editorial

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.