Skip to main content
Erschienen in: The Journal of Indian Prosthodontic Society 1/2014

01.03.2014 | Review Article

Passive Fit in Screw Retained Multi-unit Implant Prosthesis Understanding and Achieving: A Review of the Literature

verfasst von: Muaiyed Mahmoud Buzayan, Norsiah Binti Yunus

Erschienen in: The Journal of Indian Prosthodontic Society | Ausgabe 1/2014

Einloggen, um Zugang zu erhalten

Abstract

One of the considerable challenges for screw-retained multi-unit implant prosthesis is achieving a passive fit of the prosthesis’ superstructure to the implants. This passive fit is supposed to be one of the most vital requirements for the maintenance of the osseointegration. On the other hand, the misfit of the implant supported superstructure may lead to unfavourable complications, which can be mechanical or biological in nature. The manifestations of these complications may range from fracture of various components in the implant system, pain, marginal bone loss, and even loss of osseointegration. Thus, minimizing the misfit and optimizing the passive fit should be a prerequisite for implant survival and success. The purpose of this article is to present and summarize some aspects of the passive fit achieving and improving methods. The literature review was performed through Science Direct, Pubmed, and Google database. They were searched in English using the following combinations of keywords: passive fit, implant misfit and framework misfit. Articles were selected on the basis of whether they had sufficient information related to framework misfit’s related factors, passive fit and its achievement techniques, marginal bone changes relation with the misfit, implant impression techniques and splinting concept. The related references were selected in order to emphasize the importance of the passive fit achievement and the misfit minimizing. Despite the fact that the literature presents considerable information regarding the framework’s misfit, there was not consistency in literature on a specified number or even a range to be the acceptable level of misfit. On the other hand, a review of the literature revealed that the complete passive fit still remains a tricky goal to be achieved by the prosthodontist.
Literatur
1.
Zurück zum Zitat Michalakis KX, Hirayama H (2003) Garefis PDCement-retained versus screw-retained implant restorations: a critical review. Int J Oral Maxillofac Implants 18:719–728PubMed Michalakis KX, Hirayama H (2003) Garefis PDCement-retained versus screw-retained implant restorations: a critical review. Int J Oral Maxillofac Implants 18:719–728PubMed
2.
Zurück zum Zitat Assif D, Marshak B, Schmidt A (1996) Accuracy of implant impression techniques. Int J Oral Maxillofac Implants 11:216–222PubMed Assif D, Marshak B, Schmidt A (1996) Accuracy of implant impression techniques. Int J Oral Maxillofac Implants 11:216–222PubMed
3.
Zurück zum Zitat Assif D, Marshak B, Nissan J (1994) A modified impression technique for implant-supported restoration. J Prosthet Dent 71:589–591PubMedCrossRef Assif D, Marshak B, Nissan J (1994) A modified impression technique for implant-supported restoration. J Prosthet Dent 71:589–591PubMedCrossRef
4.
Zurück zum Zitat Jemt T (1991) Failures and complications in 391 consecutively inserted fixed prostheses supported by Branemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants 6:270–276PubMed Jemt T (1991) Failures and complications in 391 consecutively inserted fixed prostheses supported by Branemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants 6:270–276PubMed
5.
Zurück zum Zitat Jemt T, Book K (1996) Prosthesis misfit and marginal bone loss in edentulous implant patients.”. Int J Oral Maxillofac Implants 11:620–625PubMed Jemt T, Book K (1996) Prosthesis misfit and marginal bone loss in edentulous implant patients.”. Int J Oral Maxillofac Implants 11:620–625PubMed
6.
Zurück zum Zitat Kan JY, Rungcharassaeng K, Bohsali K, Goodacre CJ, Lang BR (1999) Clinical methods for evaluating implant framework fit. J Prosthet Dent 81:7–13PubMedCrossRef Kan JY, Rungcharassaeng K, Bohsali K, Goodacre CJ, Lang BR (1999) Clinical methods for evaluating implant framework fit. J Prosthet Dent 81:7–13PubMedCrossRef
7.
Zurück zum Zitat Taylor TD, Agar JR, Vogiatzi T (2000) Implant prosthodontics: current perspective and future directions. Int J Oral Maxillofac Implants 15:66–75PubMed Taylor TD, Agar JR, Vogiatzi T (2000) Implant prosthodontics: current perspective and future directions. Int J Oral Maxillofac Implants 15:66–75PubMed
8.
Zurück zum Zitat Randi AP, Hsu AT, Verga A, Kim JJ (2001) Dimensional accuracy and retentive strength of a retrievable cement-retained implant supported prosthesis. Int J Oral Maxillofac Implants 16:547–556PubMed Randi AP, Hsu AT, Verga A, Kim JJ (2001) Dimensional accuracy and retentive strength of a retrievable cement-retained implant supported prosthesis. Int J Oral Maxillofac Implants 16:547–556PubMed
9.
Zurück zum Zitat Branemark PI, Zarb GA, Albrektsson T (1985) Tissue -integrated prostheses. Quintessence, Chicago, p 253 Branemark PI, Zarb GA, Albrektsson T (1985) Tissue -integrated prostheses. Quintessence, Chicago, p 253
10.
Zurück zum Zitat Jemt T, Rubenstein JE, Carlsson L, Lang BR (1996) Measuring fit at the implant prosthodontic interface. J Prosthet Dent 75:314–325PubMedCrossRef Jemt T, Rubenstein JE, Carlsson L, Lang BR (1996) Measuring fit at the implant prosthodontic interface. J Prosthet Dent 75:314–325PubMedCrossRef
11.
Zurück zum Zitat Wee AG, Aquilino SA, Schneider RL (1999) Strategies to achieve fit in implant prosthodontics: a review of the literature. Int J Prosthodont 12:167–178PubMed Wee AG, Aquilino SA, Schneider RL (1999) Strategies to achieve fit in implant prosthodontics: a review of the literature. Int J Prosthodont 12:167–178PubMed
12.
Zurück zum Zitat Sorrentino R, Gherlone EF, Calesini G, Zarone F (2010) Effect of implant angulation, connection length, and impression material on the dimensional accuracy of implant impressions: an in vitro comparative study. Clin Implant Dent Relat Res 12(Suppl 1):e63–e76PubMed Sorrentino R, Gherlone EF, Calesini G, Zarone F (2010) Effect of implant angulation, connection length, and impression material on the dimensional accuracy of implant impressions: an in vitro comparative study. Clin Implant Dent Relat Res 12(Suppl 1):e63–e76PubMed
13.
Zurück zum Zitat Ma T, Nicholls JI, Rubenstein JE (1997) Tolerance measurements of various implant components. Int J Oral Maxillofac Implants 12:371–375PubMed Ma T, Nicholls JI, Rubenstein JE (1997) Tolerance measurements of various implant components. Int J Oral Maxillofac Implants 12:371–375PubMed
14.
Zurück zum Zitat Kim S, Nicholls JI, Han CH, Lee KW (2006) Displacement of implant components from impressions to definitive casts. Int J Oral Maxillofac Implants 21:747–755PubMed Kim S, Nicholls JI, Han CH, Lee KW (2006) Displacement of implant components from impressions to definitive casts. Int J Oral Maxillofac Implants 21:747–755PubMed
15.
Zurück zum Zitat Roberts WE, Smith RK, Zilberman Y, Mozsary PG, Smith RS (1984) Osseous adaptation to continuous loading of rigid endosseous implants. Am J Orthod 86:95–111PubMedCrossRef Roberts WE, Smith RK, Zilberman Y, Mozsary PG, Smith RS (1984) Osseous adaptation to continuous loading of rigid endosseous implants. Am J Orthod 86:95–111PubMedCrossRef
16.
Zurück zum Zitat Michaels GC, Carr AB, Larsen PE (1997) Effect of prosthetic superstructure accuracy on the osteointegrated implant bone interface. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 83:198–205PubMedCrossRef Michaels GC, Carr AB, Larsen PE (1997) Effect of prosthetic superstructure accuracy on the osteointegrated implant bone interface. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 83:198–205PubMedCrossRef
17.
Zurück zum Zitat Klinberged IJ, Murray GM (1985) Design of superstructures for osseointegrated fixtures. Swed Dent J 28:63–69 Klinberged IJ, Murray GM (1985) Design of superstructures for osseointegrated fixtures. Swed Dent J 28:63–69
18.
Zurück zum Zitat Assuncao WG, Filho HG, Zaniquelli O (2004) Evaluation of transfer impressions for osseointegrated implants at various angulations. Implant Dent 13:358–366PubMed Assuncao WG, Filho HG, Zaniquelli O (2004) Evaluation of transfer impressions for osseointegrated implants at various angulations. Implant Dent 13:358–366PubMed
19.
Zurück zum Zitat Lee H, Ercoli C, Funkenbusch PD, Feng C (2008) Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: an in vitro study. J Prosthet Dent 99:107–113PubMedCrossRef Lee H, Ercoli C, Funkenbusch PD, Feng C (2008) Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: an in vitro study. J Prosthet Dent 99:107–113PubMedCrossRef
20.
Zurück zum Zitat Rashidan N, Alikhasi M, Samadizadeh S, Beyabanaki E, Kharazifard MJ (2009) Accuracy of implant impressions with different impression coping types and shapes. Clin Implant Dent Relat Res 14(2):218–225PubMedCrossRef Rashidan N, Alikhasi M, Samadizadeh S, Beyabanaki E, Kharazifard MJ (2009) Accuracy of implant impressions with different impression coping types and shapes. Clin Implant Dent Relat Res 14(2):218–225PubMedCrossRef
21.
Zurück zum Zitat Robert G, Craig JMP (2002) Restorative dental materials. Mosby, St. Louis Robert G, Craig JMP (2002) Restorative dental materials. Mosby, St. Louis
22.
Zurück zum Zitat Daoudi MF, Setchell DJ, Searson LJ (2001) A laboratory investigation of the accuracy of two impression techniques for single-tooth implants.”. Int J Prosthodont 14:152–158PubMed Daoudi MF, Setchell DJ, Searson LJ (2001) A laboratory investigation of the accuracy of two impression techniques for single-tooth implants.”. Int J Prosthodont 14:152–158PubMed
23.
Zurück zum Zitat Wenz HJ, Hertrampf K (2008) Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection. Int J Oral Maxillofac Implants 23:39–47PubMed Wenz HJ, Hertrampf K (2008) Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection. Int J Oral Maxillofac Implants 23:39–47PubMed
24.
Zurück zum Zitat Aguilar ML, Augusto Elias, Toro Vizcarrondo CE, Psoter WJ (2009) Analysis of three-dimensional distortion of two impression materials in the transfer of dental implants. J Prosthet Dent 103:202–209CrossRef Aguilar ML, Augusto Elias, Toro Vizcarrondo CE, Psoter WJ (2009) Analysis of three-dimensional distortion of two impression materials in the transfer of dental implants. J Prosthet Dent 103:202–209CrossRef
25.
Zurück zum Zitat Donovan TE, Chee WW (2004) A review of contemporary impression materials and techniques. Dent Clin North Am 48:445–470CrossRef Donovan TE, Chee WW (2004) A review of contemporary impression materials and techniques. Dent Clin North Am 48:445–470CrossRef
26.
Zurück zum Zitat Burns J, Palmer R, Howe L, Wilson R (2003) Accuracy of open tray implant impressions: an in vitro comparison of stock versus custom trays. J Prosthet Dent 89:250–255PubMedCrossRef Burns J, Palmer R, Howe L, Wilson R (2003) Accuracy of open tray implant impressions: an in vitro comparison of stock versus custom trays. J Prosthet Dent 89:250–255PubMedCrossRef
27.
Zurück zum Zitat Shen C (2003) Impression material. “K.J. Phillip’s science of dental materials”. Saunders, Philadelphia, pp 205–254 Shen C (2003) Impression material. “K.J. Phillip’s science of dental materials”. Saunders, Philadelphia, pp 205–254
28.
Zurück zum Zitat Carr AB (1991) Comparison of impression techniques for a five-implant mandibular model. Int J Oral Maxillofac Implants 6:448–455PubMed Carr AB (1991) Comparison of impression techniques for a five-implant mandibular model. Int J Oral Maxillofac Implants 6:448–455PubMed
29.
Zurück zum Zitat Conrad HJ, Pesun IJ, DeLong R, Hodges JS (2007) Accuracy of two impression techniques with angulated implants. J Prosthet Dent 97:349–356PubMedCrossRef Conrad HJ, Pesun IJ, DeLong R, Hodges JS (2007) Accuracy of two impression techniques with angulated implants. J Prosthet Dent 97:349–356PubMedCrossRef
30.
Zurück zum Zitat Vigolo P, Majzoub Z, Cordioli G (2000) In vitro comparison of master cast accuracy for single-tooth implant replacement. J Prosthet Dent 83:562–566PubMedCrossRef Vigolo P, Majzoub Z, Cordioli G (2000) In vitro comparison of master cast accuracy for single-tooth implant replacement. J Prosthet Dent 83:562–566PubMedCrossRef
31.
Zurück zum Zitat Vigolo P, Majzoub Z, Cordioli G (2003) Evaluation of the accuracy of three techniques used for multiple implant abutment impressions. J Prosthet Dent 89:186–192PubMedCrossRef Vigolo P, Majzoub Z, Cordioli G (2003) Evaluation of the accuracy of three techniques used for multiple implant abutment impressions. J Prosthet Dent 89:186–192PubMedCrossRef
32.
Zurück zum Zitat Vigolo P, Fonzi F et al (2004) An evaluation of impression techniques for multiple internal connection implant prostheses. J Prosthet Dent 92:470–476PubMedCrossRef Vigolo P, Fonzi F et al (2004) An evaluation of impression techniques for multiple internal connection implant prostheses. J Prosthet Dent 92:470–476PubMedCrossRef
33.
Zurück zum Zitat Lee H, So JS, Hochstedler JL, Ercoli C (2008) The accuracy of implant impressions: a systematic review. J Prosthet Dent 100:285–291PubMedCrossRef Lee H, So JS, Hochstedler JL, Ercoli C (2008) The accuracy of implant impressions: a systematic review. J Prosthet Dent 100:285–291PubMedCrossRef
34.
Zurück zum Zitat Akca K, Cehreli MC (2004) Accuracy of 2 impression techniques for ITI implants. Int J Oral Maxillofac Implants 19:517–523PubMed Akca K, Cehreli MC (2004) Accuracy of 2 impression techniques for ITI implants. Int J Oral Maxillofac Implants 19:517–523PubMed
35.
Zurück zum Zitat Phillips KM, Nicholls J, Ma T, Rubenstein J (1994) The accuracy of three implant impression techniques: a three-dimensional analysis. Int J Oral Maxillofac Implants 9:533–540 Phillips KM, Nicholls J, Ma T, Rubenstein J (1994) The accuracy of three implant impression techniques: a three-dimensional analysis. Int J Oral Maxillofac Implants 9:533–540
36.
Zurück zum Zitat Del’Acqua MA, Arioli-Filho JN, Compagnoni MA, Mollo Fde A Jr (2008) Accuracy of impression and pouring techniques for an implant-supported prosthesis. Int J Oral Maxillofac Implants 23:226–236PubMed Del’Acqua MA, Arioli-Filho JN, Compagnoni MA, Mollo Fde A Jr (2008) Accuracy of impression and pouring techniques for an implant-supported prosthesis. Int J Oral Maxillofac Implants 23:226–236PubMed
37.
Zurück zum Zitat Humphries RM, Yaman P, Bloem TJ (1990) The accuracy of implant master casts constructed from transfer impressions. Int J Oral Maxillofac Implants 5:331–336PubMed Humphries RM, Yaman P, Bloem TJ (1990) The accuracy of implant master casts constructed from transfer impressions. Int J Oral Maxillofac Implants 5:331–336PubMed
38.
Zurück zum Zitat De La Cruz JE, Funkenbusch PD, Ercoli C, Moss ME, Graser GN, Tallents RH (2002) Verification jig for implant-supported prostheses: a comparison of standard impressions with verification jigs made of different materials. J Prosthet Dent 88:329–336PubMedCrossRef De La Cruz JE, Funkenbusch PD, Ercoli C, Moss ME, Graser GN, Tallents RH (2002) Verification jig for implant-supported prostheses: a comparison of standard impressions with verification jigs made of different materials. J Prosthet Dent 88:329–336PubMedCrossRef
39.
Zurück zum Zitat Herbst D, Nel JC, Driessen CH, Becker PJ (2000) Evaluation of impression accuracy for osseointegrated implant supported superstructures. J Prosthet Dent 83:555–561PubMedCrossRef Herbst D, Nel JC, Driessen CH, Becker PJ (2000) Evaluation of impression accuracy for osseointegrated implant supported superstructures. J Prosthet Dent 83:555–561PubMedCrossRef
40.
Zurück zum Zitat Daoudi MF, Setchell DJ, Searson LJ (2004) An evaluation of three implant level impression techniques for single tooth implant.”. Eur J Prosthodont Restor Dent 12:9–14PubMed Daoudi MF, Setchell DJ, Searson LJ (2004) An evaluation of three implant level impression techniques for single tooth implant.”. Eur J Prosthodont Restor Dent 12:9–14PubMed
41.
Zurück zum Zitat Naconecy MM, Teixeira ER, Shinkai RS, Frasca LC, Cervieri A (2004) Evaluation of the accuracy of 3 transfer techniques for implant-supported prostheses with multiple abutments. Int J Oral Maxillofac Implants 19:192–198PubMed Naconecy MM, Teixeira ER, Shinkai RS, Frasca LC, Cervieri A (2004) Evaluation of the accuracy of 3 transfer techniques for implant-supported prostheses with multiple abutments. Int J Oral Maxillofac Implants 19:192–198PubMed
42.
Zurück zum Zitat Spector MR, Donovan TE, Nicholls JI (1990) An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent 63:444–447PubMedCrossRef Spector MR, Donovan TE, Nicholls JI (1990) An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent 63:444–447PubMedCrossRef
43.
Zurück zum Zitat Inturregui JA, Aquilino SA, Ryther JS, Lund PS (1993) Evaluation of three impression techniques for osseointegrated oral implants. J Prosthet Dent 69:503–509PubMedCrossRef Inturregui JA, Aquilino SA, Ryther JS, Lund PS (1993) Evaluation of three impression techniques for osseointegrated oral implants. J Prosthet Dent 69:503–509PubMedCrossRef
44.
Zurück zum Zitat Burawi G, Houston F, Byrne D, Claffey N (1997) A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-Lock implant system. J Prosthet Dent 77:68–75PubMedCrossRef Burawi G, Houston F, Byrne D, Claffey N (1997) A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-Lock implant system. J Prosthet Dent 77:68–75PubMedCrossRef
45.
Zurück zum Zitat Mojon P, Oberholzer JP, Oberholzer JP, Meyer JM, Belser UC (1990) Polymerization shrinkage of index and pattern acrylic resins. J Prosthet Dent 64:684–688PubMedCrossRef Mojon P, Oberholzer JP, Oberholzer JP, Meyer JM, Belser UC (1990) Polymerization shrinkage of index and pattern acrylic resins. J Prosthet Dent 64:684–688PubMedCrossRef
46.
Zurück zum Zitat Hsu CC, Millstein PL, Stein RS (1993) A comparative analysis of the accuracy of implant transfer techniques. J Prosthet Dent 69:588–593PubMedCrossRef Hsu CC, Millstein PL, Stein RS (1993) A comparative analysis of the accuracy of implant transfer techniques. J Prosthet Dent 69:588–593PubMedCrossRef
47.
Zurück zum Zitat Assif D, Nissan J, Varsano I, Singer A (1999) Accuracy of implant impression splinted techniques: effect of splinting material. Int J Oral Maxillofac Implants 14:885–888PubMed Assif D, Nissan J, Varsano I, Singer A (1999) Accuracy of implant impression splinted techniques: effect of splinting material. Int J Oral Maxillofac Implants 14:885–888PubMed
48.
Zurück zum Zitat Eid N (2004) An implant impression technique using a plaster splinting index combined with a silicone impression. J Prosthet Dent 92:575–577PubMedCrossRef Eid N (2004) An implant impression technique using a plaster splinting index combined with a silicone impression. J Prosthet Dent 92:575–577PubMedCrossRef
49.
Zurück zum Zitat Hariharan R, Shankar C, Rajan M, Baig MR, Azhagarasan NS (2010) Evaluation of accuracy of multiple dental implant impressions using various splinting materials. Int J Oral Maxillofac Implants 25:38–44PubMed Hariharan R, Shankar C, Rajan M, Baig MR, Azhagarasan NS (2010) Evaluation of accuracy of multiple dental implant impressions using various splinting materials. Int J Oral Maxillofac Implants 25:38–44PubMed
Metadaten
Titel
Passive Fit in Screw Retained Multi-unit Implant Prosthesis Understanding and Achieving: A Review of the Literature
verfasst von
Muaiyed Mahmoud Buzayan
Norsiah Binti Yunus
Publikationsdatum
01.03.2014
Verlag
Springer India
Erschienen in
The Journal of Indian Prosthodontic Society / Ausgabe 1/2014
Print ISSN: 0972-4052
Elektronische ISSN: 1998-4057
DOI
https://doi.org/10.1007/s13191-013-0343-x

Weitere Artikel der Ausgabe 1/2014

The Journal of Indian Prosthodontic Society 1/2014 Zur Ausgabe

Parodontalbehandlung verbessert Prognose bei Katheterablation

19.04.2024 Vorhofflimmern Nachrichten

Werden Personen mit Vorhofflimmern in der Blanking-Periode nach einer Katheterablation gegen eine bestehende Parodontitis behandelt, verbessert dies die Erfolgsaussichten. Dafür sprechen die Resultate einer prospektiven Untersuchung.

Invasive Zahnbehandlung: Wann eine Antibiotikaprophylaxe vor infektiöser Endokarditis schützt

11.04.2024 Endokarditis Nachrichten

Bei welchen Personen eine Antibiotikaprophylaxe zur Prävention einer infektiösen Endokarditis nach invasiven zahnärztlichen Eingriffen sinnvoll ist, wird diskutiert. Neue Daten stehen im Einklang mit den europäischen Leitlinienempfehlungen.

Zell-Organisatoren unter Druck: Mechanismen des embryonalen Zahnwachstums aufgedeckt

08.04.2024 Zahnmedizin Nachrichten

Der Aufbau von Geweben und Organen während der Embryonalentwicklung wird von den Zellen bemerkenswert choreografiert. Für diesen Prozess braucht es spezielle sogenannte „Organisatoren“. In einer aktuellen Veröffentlichung im Fachjournal Nature Cell Biology berichten Forschende durch welchen Vorgang diese Organisatoren im Gewebe entstehen und wie sie dann die Bildung von Zähnen orchestrieren.

Die Oralprophylaxe & Kinderzahnheilkunde umbenannt

11.03.2024 Kinderzahnmedizin Nachrichten

Infolge der Umbenennung der Deutschen Gesellschaft für Kinderzahnheilkunde in Deutsche Gesellschaft für Kinderzahnmedizin (DGKiZ) wird deren Mitgliederzeitschrift Oralprophylaxe & Kinderzahnheilkunde in Oralprophylaxe & Kinderzahnmedizin umbenannt. Aus diesem Grunde trägt die erste Ausgabe in 2024 erstmalig den neuen Titel.

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.