Objective To determine the rate and the primary types of medication dispensing errors detected by pharmacists during implementation of a unit dose drug dispensing system. Setting The central pharmacy at the Percy French military hospital (France). Method The check of the unit dose medication cassettes was performed by pharmacists to identify dispensing errors before delivering to the care units. From April 2006 to December 2006, detected errors were corrected and recorded into seven categories: unauthorized drug, wrong dosage-form, improper dose, omission, wrong time, deteriorated drug, and wrong patient errors. Main outcome measure Dispensing error rate, calculated by dividing the total of detected errors by the total of filled and omitted doses; classification of recorded dispensing errors. Results During the study, 9,719 unit dose medication cassettes were filled by pharmacy technicians. Pharmacists detected 706 errors for a total of 88,609 filled and omitted unit doses. An overall error rate of 0.80% was found. There were approximately 0.07 detected dispensing errors per medication cassette. The most common error types were improper dose errors (n = 265, 37.5%) and omission errors (n = 186, 26.3%). Many causes may probably explain the occurrence of dispensing errors, including communication failures, problems related to drug labeling or packaging, distractions, interruptions, heavy workload, and difficulties in reading handwriting prescriptions. Conclusion The results showed that a wide range of errors occurred during the dispensing process. A check performed after the initial medication selection is also necessary to detect and correct dispensing errors. In order to decrease the occurrence of dispensing errors, some practical measures have been implemented in the central pharmacy. But because some dispensing errors may remain undetected, there is a requirement to develop other strategies that reduce or eliminate these errors. The pharmacy staff is widely involved in this duty.
Literatur
1.
Zurück zum Zitat Kohn LT, Corrigan JM, Donaldson MS. To err is human: building a safer health system. Washington, DC: Committee on Quality of Health Care in America, Institute of Medicine, National Academy Press; 2000. Kohn LT, Corrigan JM, Donaldson MS. To err is human: building a safer health system. Washington, DC: Committee on Quality of Health Care in America, Institute of Medicine, National Academy Press; 2000.
4.
Zurück zum Zitat Scala-Barnett DM, Donoghue ER. Dispensing error causing fatal chlorpropamide intoxication in a nondiabetic. J Forensic Sci. 1986;31:293–5.CrossRefPubMed Scala-Barnett DM, Donoghue ER. Dispensing error causing fatal chlorpropamide intoxication in a nondiabetic. J Forensic Sci. 1986;31:293–5.CrossRefPubMed
8.
Zurück zum Zitat Parker PF. Drug distribution in hospitals. Unit-dose systems reduce error, increase efficiency. Hospitals. 1968;42:65–72.PubMed Parker PF. Drug distribution in hospitals. Unit-dose systems reduce error, increase efficiency. Hospitals. 1968;42:65–72.PubMed
9.
Zurück zum Zitat McConnell WE, Barker KN, Garrity LF. Dispensing: report of a study. Am J Hosp Pharm. 1961;18:531–41. McConnell WE, Barker KN, Garrity LF. Dispensing: report of a study. Am J Hosp Pharm. 1961;18:531–41.
10.
Zurück zum Zitat Lepinski PW, Thielke TS, Collins DM, Hanson A. Cost comparison of unit dose and traditional drug distribution in a long-term-care facility. Am J Hosp Pharm. 1986;43:2771–9.PubMed Lepinski PW, Thielke TS, Collins DM, Hanson A. Cost comparison of unit dose and traditional drug distribution in a long-term-care facility. Am J Hosp Pharm. 1986;43:2771–9.PubMed
11.
Zurück zum Zitat Fontan JE, Maneglier V, Nguyen VX, Loirat C, Brion F. Medication errors in hospitals: computerized unit dose drug dispensing system versus ward stock distribution system. Pharm World Sci. 2003;25:112–7. doi:10.1023/A:1024053514359.CrossRefPubMed Fontan JE, Maneglier V, Nguyen VX, Loirat C, Brion F. Medication errors in hospitals: computerized unit dose drug dispensing system versus ward stock distribution system. Pharm World Sci. 2003;25:112–7. doi:10.​1023/​A:​1024053514359.CrossRefPubMed
12.
Zurück zum Zitat Arnaud L, Coyral D, Dufauret C, Fernandez B, Vergne-Salle P, Bonnet C, et al. A propos d’une expérience d’organisation de dispensation journalière individuelle nominative (DJIN). Actualités pharmaceutiques hospitalières. 2005;1:37–44.CrossRef Arnaud L, Coyral D, Dufauret C, Fernandez B, Vergne-Salle P, Bonnet C, et al. A propos d’une expérience d’organisation de dispensation journalière individuelle nominative (DJIN). Actualités pharmaceutiques hospitalières. 2005;1:37–44.CrossRef
13.
Zurück zum Zitat Hassal TH, Daniels CE. Evaluation of three types of control chart methods in unit dose error monitoring. Am J Hosp Pharm. 1983;40:970–5. Hassal TH, Daniels CE. Evaluation of three types of control chart methods in unit dose error monitoring. Am J Hosp Pharm. 1983;40:970–5.
14.
Zurück zum Zitat Taylor J, Gaucher M. Medication selection errors made by pharmacy technicians in filling unit dose orders. Can J Hosp Pharm. 1986;39:9–12.PubMed Taylor J, Gaucher M. Medication selection errors made by pharmacy technicians in filling unit dose orders. Can J Hosp Pharm. 1986;39:9–12.PubMed
15.
Zurück zum Zitat Klein EG, Santora JA, Pascale PM, Kitrenos JG. Medication cart-filling time accuracy, and cost with an automated dispensing system. Am J Hosp Pharm. 1994;51:1193–6.PubMed Klein EG, Santora JA, Pascale PM, Kitrenos JG. Medication cart-filling time accuracy, and cost with an automated dispensing system. Am J Hosp Pharm. 1994;51:1193–6.PubMed
16.
Zurück zum Zitat Cina JL, Gandhi TK, Churchill W, Fanikos J, McCrea M, Mitton P, et al. How many hospital pharmacy medication dispensing errors go undetected? Jt Comm J Qual Patient Saf. 2006;32:73–80.CrossRefPubMed Cina JL, Gandhi TK, Churchill W, Fanikos J, McCrea M, Mitton P, et al. How many hospital pharmacy medication dispensing errors go undetected? Jt Comm J Qual Patient Saf. 2006;32:73–80.CrossRefPubMed
17.
Zurück zum Zitat American society of hospital pharmacists. ASHP guidelines on preventing medication errors in hospitals. Am J Hosp Pharm. 1993;50:305–14. American society of hospital pharmacists. ASHP guidelines on preventing medication errors in hospitals. Am J Hosp Pharm. 1993;50:305–14.
24.
Zurück zum Zitat Becker MD, Johnson MH, Longe RL. Errors remaining in unit dose carts after checking by pharmacists versus pharmacy technicians. Am J Hosp Pharm. 1978;35:432–4.PubMed Becker MD, Johnson MH, Longe RL. Errors remaining in unit dose carts after checking by pharmacists versus pharmacy technicians. Am J Hosp Pharm. 1978;35:432–4.PubMed
25.
Zurück zum Zitat Woller TW, Stuart J, Vrabel R, Senst B. Checking of unit dose cassettes by pharmacy technicians at three Minnesota hospitals. Am J Hosp Pharm. 1991;48:1952–6.PubMed Woller TW, Stuart J, Vrabel R, Senst B. Checking of unit dose cassettes by pharmacy technicians at three Minnesota hospitals. Am J Hosp Pharm. 1991;48:1952–6.PubMed
26.
Zurück zum Zitat Ness JE, Sullivan SD, Stergachis A. Accuracy of technicians and pharmacists in identifying dispensing errors. Am J Hosp Pharm. 1994;51:354–7.PubMed Ness JE, Sullivan SD, Stergachis A. Accuracy of technicians and pharmacists in identifying dispensing errors. Am J Hosp Pharm. 1994;51:354–7.PubMed
27.
Zurück zum Zitat Spooner SH, Emerson PK. Using hospital pharmacy technicians to check unit dose carts. Hosp Pharm. 1994;29:433–7.PubMed Spooner SH, Emerson PK. Using hospital pharmacy technicians to check unit dose carts. Hosp Pharm. 1994;29:433–7.PubMed
28.
Zurück zum Zitat Ambrose PJ, Saya FG, Lovett LT, Tan S, Adams DW, Shane R. Evaluating the accuracy of technicians and pharmacists in checking unit dose medication cassettes. Am J Health Syst Pharm. 2002;59:1183–8.PubMed Ambrose PJ, Saya FG, Lovett LT, Tan S, Adams DW, Shane R. Evaluating the accuracy of technicians and pharmacists in checking unit dose medication cassettes. Am J Health Syst Pharm. 2002;59:1183–8.PubMed
29.
Zurück zum Zitat Scarsi KK, Fotis MA, Noskin GA. Pharmacist participation in medical rounds reduces medication errors. Am J Health Syst Pharm. 2002;59:2089–92.PubMed Scarsi KK, Fotis MA, Noskin GA. Pharmacist participation in medical rounds reduces medication errors. Am J Health Syst Pharm. 2002;59:2089–92.PubMed
30.
Zurück zum Zitat Weant KA, Cook AM, Armitstead JA. Medication-error reporting and pharmacy resident experience during implementation of computerized prescriber order entry. Am J Health Syst Pharm. 2007;64:526–30. doi:10.2146/ajhp060001.CrossRefPubMed Weant KA, Cook AM, Armitstead JA. Medication-error reporting and pharmacy resident experience during implementation of computerized prescriber order entry. Am J Health Syst Pharm. 2007;64:526–30. doi:10.​2146/​ajhp060001.CrossRefPubMed
34.
Zurück zum Zitat Kratz K, Thygesen C. A comparison of the accuracy of unit dose cart fill with the Baxter ATC-212 computerized system and manual filling. Hosp Pharm. 1992;27:19–20.PubMed Kratz K, Thygesen C. A comparison of the accuracy of unit dose cart fill with the Baxter ATC-212 computerized system and manual filling. Hosp Pharm. 1992;27:19–20.PubMed
35.
Zurück zum Zitat Scott O, Caldwell R. Dispensing error rate after implementation of an automated pharmacy carousel system. Am J Health Syst Pharm. 2007;64:1427–31. doi:10.2146/ajhp060636.CrossRef Scott O, Caldwell R. Dispensing error rate after implementation of an automated pharmacy carousel system. Am J Health Syst Pharm. 2007;64:1427–31. doi:10.​2146/​ajhp060636.CrossRef
36.
Zurück zum Zitat Poon EG, Cina JL, Churchill W, Patel N, Featherstone E, Rothschild JM, et al. Medication dispensing errors and potential adverse drug events before and after implementing bar code technology in the pharmacy. Ann Intern Med. 2006;145:426–34.CrossRefPubMed Poon EG, Cina JL, Churchill W, Patel N, Featherstone E, Rothschild JM, et al. Medication dispensing errors and potential adverse drug events before and after implementing bar code technology in the pharmacy. Ann Intern Med. 2006;145:426–34.CrossRefPubMed
37.
Zurück zum Zitat Flynn EA, Barker KN, Pepper GA, Bates DW, Mikeal RL. Comparison of methods for detecting medication errors in 36 hospitals and skilled-nursing facilities. Am J Health Syst Pharm. 2002;59:436–46.PubMed Flynn EA, Barker KN, Pepper GA, Bates DW, Mikeal RL. Comparison of methods for detecting medication errors in 36 hospitals and skilled-nursing facilities. Am J Health Syst Pharm. 2002;59:436–46.PubMed
Metadaten
Titel
Medication dispensing errors in a French military hospital pharmacy
verfasst von
Xavier Bohand
Olivier Aupée
Patrick Le Garlantezec
Hélène Mullot
Leslie Lefeuvre
Laurent Simon
Publikationsdatum
01.08.2009
Verlag
Springer Netherlands
Erschienen in
International Journal of Clinical Pharmacy / Ausgabe 4/2009
Print ISSN: 2210-7703
Elektronische ISSN: 2210-7711
DOI
https://doi.org/10.1007/s11096-009-9290-3

Weitere Artikel der Ausgabe 4/2009

International Journal of Clinical Pharmacy 4/2009 Zur Ausgabe

Editorial

Editorial

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.