Skip to main content
Erschienen in: Current Reviews in Musculoskeletal Medicine 1/2016

01.03.2016 | Hip: Metal-on-Metal (J Cooper, Section Editor)

Metal-on-metal total hip arthroplasty: is there still a role in 2016?

verfasst von: Edward J. Silverman, Blair Ashley, Neil P. Sheth

Erschienen in: Current Reviews in Musculoskeletal Medicine | Ausgabe 1/2016

Einloggen, um Zugang zu erhalten

Abstract

The use of metal-on-metal (MoM) bearings in total hip arthroplasty (THA) was popularized due to its enhanced wear profile and the ability to use large femoral heads to reduce post-operative instability. However, enthusiasm for the bearing declined following serious complications encountered at the primary articulation. This review discusses the development of MoM and the subsequent unexpected downstream challenges, most notably elevated serum metal ion levels, aseptic lymphocyte-dominated vasculitis-associated lesions (ALVAL), pseudotumor formation, and subsequent soft tissue and bone destruction. Both patient centered risk factors as well as component design led to high early failure rates resulting in product recalls and an overall decline in the use of MoM. In 2016, there is not a role for large-head MoM bearing in THA. Alternatively, the bearing has shown promise in hip resurfacing procedures for carefully selected patients.
Literatur
1.
Zurück zum Zitat Hannouche D, Nich C, Bizot P, Meunier A, Nizard R, Sedel L. Fractures of ceramic bearings: history and present status. Clinical Orthopaedics and Related Research. 2003;417:19–26.PubMed Hannouche D, Nich C, Bizot P, Meunier A, Nizard R, Sedel L. Fractures of ceramic bearings: history and present status. Clinical Orthopaedics and Related Research. 2003;417:19–26.PubMed
2.
Zurück zum Zitat Traina F, De Fine M, Di Mrtino A, Faldini C. Fracture of ceramic bearing surfaces following total hip replacement: a systematic review. BioMed Res Int. 2013;1–8. Traina F, De Fine M, Di Mrtino A, Faldini C. Fracture of ceramic bearing surfaces following total hip replacement: a systematic review. BioMed Res Int. 2013;1–8.
3.
Zurück zum Zitat Senturk U, Perka C. Ceramic-on-ceramic bearings in total hip arthroplasty (THA). Z Orthop Unfall. 2015;153:198–202.CrossRefPubMed Senturk U, Perka C. Ceramic-on-ceramic bearings in total hip arthroplasty (THA). Z Orthop Unfall. 2015;153:198–202.CrossRefPubMed
4.
Zurück zum Zitat Baek SH, Kim WK, Kin JY, Kim SY. Do alumina matrix composite bearings decrease hip noises and bearing fractures at a minimum of 5 years after THA? Clinical Orthopaedic and Related Research. 2015; online 7/1/2015. Baek SH, Kim WK, Kin JY, Kim SY. Do alumina matrix composite bearings decrease hip noises and bearing fractures at a minimum of 5 years after THA? Clinical Orthopaedic and Related Research. 2015; online 7/1/2015.
5.
Zurück zum Zitat Jarrett CA, Ranawat AS, Bruzzone M, Blum YC, Rodriguez JA, Ranawat CS. The squeaking hip: a phenomenon of ceramic-on-ceramic total hip arthroplasty. J Bone Joint Surg Am. 2009;91(6):1344–9.CrossRefPubMed Jarrett CA, Ranawat AS, Bruzzone M, Blum YC, Rodriguez JA, Ranawat CS. The squeaking hip: a phenomenon of ceramic-on-ceramic total hip arthroplasty. J Bone Joint Surg Am. 2009;91(6):1344–9.CrossRefPubMed
6.
Zurück zum Zitat Williams D, Royle M, Norton M. Metal-on-metal hip resurfacing. The effect of cup position and component size on range of motion to impingement. The Journal of Arthroplasty. 2009;24:144–51.CrossRefPubMed Williams D, Royle M, Norton M. Metal-on-metal hip resurfacing. The effect of cup position and component size on range of motion to impingement. The Journal of Arthroplasty. 2009;24:144–51.CrossRefPubMed
7.
Zurück zum Zitat Bedigrew KM, Ruh EL, Zhang Q, Clohisy JC, Barrach RL, Nunley RM. When to release patients to high impact activities after hip resurfacing. Clin Orthop Relat Res. 2012;470:299–306.PubMedCentralCrossRefPubMed Bedigrew KM, Ruh EL, Zhang Q, Clohisy JC, Barrach RL, Nunley RM. When to release patients to high impact activities after hip resurfacing. Clin Orthop Relat Res. 2012;470:299–306.PubMedCentralCrossRefPubMed
8.
Zurück zum Zitat Doorn PF, Campbell PA, Worrall J, Benya PD, McKellop HA, Amstutz HC. Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles. Journal of Biomedical Materials Research. 1998;42:103–11.CrossRefPubMed Doorn PF, Campbell PA, Worrall J, Benya PD, McKellop HA, Amstutz HC. Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles. Journal of Biomedical Materials Research. 1998;42:103–11.CrossRefPubMed
9.
Zurück zum Zitat Topolovec M, Cor A, Milosev I. Metal-on-metal vs. metal-on-polyethylene total hip arthroplasty tribological evaluation of retrieved components and periprosthetic tissue. Journal of the Mechanical Behavior of Biomedical Materials. 2014;34:243–52.CrossRefPubMed Topolovec M, Cor A, Milosev I. Metal-on-metal vs. metal-on-polyethylene total hip arthroplasty tribological evaluation of retrieved components and periprosthetic tissue. Journal of the Mechanical Behavior of Biomedical Materials. 2014;34:243–52.CrossRefPubMed
10.
Zurück zum Zitat Willert HG, Buchhorn GH, Fayyazi A, Flury R, Windler M, Koster G, et al. Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am. 2005;87:28–36.CrossRefPubMed Willert HG, Buchhorn GH, Fayyazi A, Flury R, Windler M, Koster G, et al. Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am. 2005;87:28–36.CrossRefPubMed
11.
Zurück zum Zitat Bosker BH, Ettema HB, Van Rossum M, Boomsma MF, Kollen BJ, Maas M, et al. Pseudotumor formation and serum ions after large head metal-on-metal stemmed total hip replacement. Risk factors, time course and revisions in 706 hips. Arch Orthop Trauma Surg. 2015;135:417–25.CrossRefPubMed Bosker BH, Ettema HB, Van Rossum M, Boomsma MF, Kollen BJ, Maas M, et al. Pseudotumor formation and serum ions after large head metal-on-metal stemmed total hip replacement. Risk factors, time course and revisions in 706 hips. Arch Orthop Trauma Surg. 2015;135:417–25.CrossRefPubMed
12.••
Zurück zum Zitat Engh CA, MacDonald SJ, Sritulanondha S, Korczak A, Naudie D, Engh C. Metal ion levels after metal-on-metal total hip arthroplasty. The Journal of Bone and Joint Surgery. 2014;96:448–55. Recent prospective study documenting increased metal ion levels in patients with metal-on-metal THA. CrossRefPubMed Engh CA, MacDonald SJ, Sritulanondha S, Korczak A, Naudie D, Engh C. Metal ion levels after metal-on-metal total hip arthroplasty. The Journal of Bone and Joint Surgery. 2014;96:448–55. Recent prospective study documenting increased metal ion levels in patients with metal-on-metal THA. CrossRefPubMed
13.
Zurück zum Zitat Bayley N, Kahn H, Grosso P, Hupel T, Stevens D, Snider M, et al. What are the predictors and prevalence of pseudotumor and elevated metal ions after large-diameter metal-on-metal THA? Clinical Orthopaedics and Related Research. 2015;473:477–84.PubMedCentralCrossRefPubMed Bayley N, Kahn H, Grosso P, Hupel T, Stevens D, Snider M, et al. What are the predictors and prevalence of pseudotumor and elevated metal ions after large-diameter metal-on-metal THA? Clinical Orthopaedics and Related Research. 2015;473:477–84.PubMedCentralCrossRefPubMed
14.
Zurück zum Zitat De Haan R, Pattyn C, Gill HS, Murray DW, Campbell PA, De Smet K. Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. The Journal of Bone and Joint Surgery (Br). 2008;90-B:1291–7.CrossRef De Haan R, Pattyn C, Gill HS, Murray DW, Campbell PA, De Smet K. Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. The Journal of Bone and Joint Surgery (Br). 2008;90-B:1291–7.CrossRef
15.
Zurück zum Zitat De Haan R, Campbell PA, Su EP, De Smet KA. Revision of metal-on-metal resurfacing arthroplasty of the hip. The influence of malpositioning of the components. The Journal of Bone and Joint Surgery (Br). 2008;90-B:1158–63.CrossRef De Haan R, Campbell PA, Su EP, De Smet KA. Revision of metal-on-metal resurfacing arthroplasty of the hip. The influence of malpositioning of the components. The Journal of Bone and Joint Surgery (Br). 2008;90-B:1158–63.CrossRef
16.
Zurück zum Zitat Klein J. Molecular mechanisms of synovial joint lubrication. Proc Inst Mech. 2006;220:691–710.CrossRef Klein J. Molecular mechanisms of synovial joint lubrication. Proc Inst Mech. 2006;220:691–710.CrossRef
17.
Zurück zum Zitat Maskiewicz et al. Characterization of protein degradation in serum-based lubricants during simulation wear testing of metal-on-metal hip prostheses. J Biomed Mat. 2000;94:429–40. Maskiewicz et al. Characterization of protein degradation in serum-based lubricants during simulation wear testing of metal-on-metal hip prostheses. J Biomed Mat. 2000;94:429–40.
18.
Zurück zum Zitat Myant C, Cann P. On the matter of synovial fluid lubrication: implications for metal on metal hip tribology. J Mech Behav Biomed Mat. 2014;34:338–48.CrossRef Myant C, Cann P. On the matter of synovial fluid lubrication: implications for metal on metal hip tribology. J Mech Behav Biomed Mat. 2014;34:338–48.CrossRef
19.
Zurück zum Zitat Marker M, Grubl A, Riedl O, Heinze G, Pohanka E, Kotz R. Metal-on-metal hip implants: do they impair renal function in the long term? A 10-year follow-up study. Arch Orthop Trauma Surg. 2008;128:915–9.CrossRefPubMed Marker M, Grubl A, Riedl O, Heinze G, Pohanka E, Kotz R. Metal-on-metal hip implants: do they impair renal function in the long term? A 10-year follow-up study. Arch Orthop Trauma Surg. 2008;128:915–9.CrossRefPubMed
20.
Zurück zum Zitat Morin Y, Daniel P. Quebec beer-drinkers cardiomyopathy: etiological considerations. J Can Med Assoc. 1967;97:926. Morin Y, Daniel P. Quebec beer-drinkers cardiomyopathy: etiological considerations. J Can Med Assoc. 1967;97:926.
21.
Zurück zum Zitat Zywiel MG, Brandt JM, Overgaard CB, Cheung AC, Turgeon TR, Syed KA. Fatal cardiomyopathy after revision total hip replacement for fracture of a ceramic liner. The Bone and Joint Journal. 2013;95-B:31–7.CrossRefPubMed Zywiel MG, Brandt JM, Overgaard CB, Cheung AC, Turgeon TR, Syed KA. Fatal cardiomyopathy after revision total hip replacement for fracture of a ceramic liner. The Bone and Joint Journal. 2013;95-B:31–7.CrossRefPubMed
22.
Zurück zum Zitat Ikeda T, Takahashi K, Kabata T, Sakagoshi D, Tomita K, Yamada M. Polyneuropathy caused by cobalt-chromium metallosis after total hip replacement. Muscle & Nerve. 2010;42:140–3.CrossRef Ikeda T, Takahashi K, Kabata T, Sakagoshi D, Tomita K, Yamada M. Polyneuropathy caused by cobalt-chromium metallosis after total hip replacement. Muscle & Nerve. 2010;42:140–3.CrossRef
23.
Zurück zum Zitat Pelclova D, Sklensky M, Janicek P, Lach K. Severe cobalt intoxication following hip replacement revision: clinical features and outcome. Clinical Toxicology. 2012;50:262–5.CrossRefPubMed Pelclova D, Sklensky M, Janicek P, Lach K. Severe cobalt intoxication following hip replacement revision: clinical features and outcome. Clinical Toxicology. 2012;50:262–5.CrossRefPubMed
24.••
Zurück zum Zitat Raghunathan VK, Devey M, Hawkins S, Hails L, Davis SA, Mann S, et al. Influence of particle size and reactive oxygen species on cobalt chrome nanoparticle-mediated genotoxicity. Biomaterials. 2013;34:3559–70. Metal ions linked to genotoxicity. CrossRefPubMed Raghunathan VK, Devey M, Hawkins S, Hails L, Davis SA, Mann S, et al. Influence of particle size and reactive oxygen species on cobalt chrome nanoparticle-mediated genotoxicity. Biomaterials. 2013;34:3559–70. Metal ions linked to genotoxicity. CrossRefPubMed
25.
Zurück zum Zitat Makela KT, Visuri T, Pulkkinen P, Eskelinen A, Remes V, Virolainen P, et al. Cancer incidence and cause-specific mortality in patients with metal-on-metal hip replacements in Finland. A population-based study with a mean follow-up of 4.6 (1–11) years. Acta Orthopaedica. 2014;85:32–8.PubMedCentralCrossRefPubMed Makela KT, Visuri T, Pulkkinen P, Eskelinen A, Remes V, Virolainen P, et al. Cancer incidence and cause-specific mortality in patients with metal-on-metal hip replacements in Finland. A population-based study with a mean follow-up of 4.6 (1–11) years. Acta Orthopaedica. 2014;85:32–8.PubMedCentralCrossRefPubMed
26.
Zurück zum Zitat De Steiger RN, Hang JR, Miller LN, Graves SE, Davidson DC. Five-year results of the ASR XL acetabular system and the ASR Hip resurfacing system: an analysis from the Australian Orthopaedic Association National Joint Replacement Registry. Journal of Bone and Joint Surgery. 2011;93:2287–93.CrossRefPubMed De Steiger RN, Hang JR, Miller LN, Graves SE, Davidson DC. Five-year results of the ASR XL acetabular system and the ASR Hip resurfacing system: an analysis from the Australian Orthopaedic Association National Joint Replacement Registry. Journal of Bone and Joint Surgery. 2011;93:2287–93.CrossRefPubMed
27.
Zurück zum Zitat Bernthal NM, Celestre PC, Stavrakis AI, Ludington JC, Oakes DA. Disappointing short-term results with the Depuy ASR XL metal-on metal total hip arthroplasty. The Journal of Arthroplasty. 2012;27:539–44.CrossRefPubMed Bernthal NM, Celestre PC, Stavrakis AI, Ludington JC, Oakes DA. Disappointing short-term results with the Depuy ASR XL metal-on metal total hip arthroplasty. The Journal of Arthroplasty. 2012;27:539–44.CrossRefPubMed
28.
Zurück zum Zitat Lehil MS, Bozic KJ. Trends in total hip arthroplasty implant utilization in the United States. The Journal of Arthroplasty. 2014;29:1915–8.CrossRefPubMed Lehil MS, Bozic KJ. Trends in total hip arthroplasty implant utilization in the United States. The Journal of Arthroplasty. 2014;29:1915–8.CrossRefPubMed
29.
Zurück zum Zitat Lavernia CJ, Iacobelli DA, Villa JM, Jones K, Gonzalez JL, Jones WK. Trunion-head stresses in THA: are big heads trouble? The Journal of Arthroplasty. 2015;30:1085–8.CrossRefPubMed Lavernia CJ, Iacobelli DA, Villa JM, Jones K, Gonzalez JL, Jones WK. Trunion-head stresses in THA: are big heads trouble? The Journal of Arthroplasty. 2015;30:1085–8.CrossRefPubMed
30.
Zurück zum Zitat Kiran M, Boscainos PJ. Adverse reaction to metal debris in metal-on-polyethylene total hip arthroplasty using a titanium-molybdenum-zirconium-iron allow stem. The Journal of Arthroplasty. 2015;30:277–81.CrossRefPubMed Kiran M, Boscainos PJ. Adverse reaction to metal debris in metal-on-polyethylene total hip arthroplasty using a titanium-molybdenum-zirconium-iron allow stem. The Journal of Arthroplasty. 2015;30:277–81.CrossRefPubMed
31.
Zurück zum Zitat Langton DJ, Jameson SS, Joyce TJ, Gandhi JN, Sidaginamale R, Mereddy P, et al. Accelerating failure rate of the ASR total hip replacement. The Journal of Bone and Joint Surgery. 2011;93B:1011–6.CrossRef Langton DJ, Jameson SS, Joyce TJ, Gandhi JN, Sidaginamale R, Mereddy P, et al. Accelerating failure rate of the ASR total hip replacement. The Journal of Bone and Joint Surgery. 2011;93B:1011–6.CrossRef
32.
Zurück zum Zitat Johnson AJ, Zywiel MG, Hooper H, Mont MA. Narrowed indications improve outcomes for hip resurfacing arthroplasty. Bulletin of the NYU Hospital for Joint Diseases. 2011;69:27–9. Johnson AJ, Zywiel MG, Hooper H, Mont MA. Narrowed indications improve outcomes for hip resurfacing arthroplasty. Bulletin of the NYU Hospital for Joint Diseases. 2011;69:27–9.
Metadaten
Titel
Metal-on-metal total hip arthroplasty: is there still a role in 2016?
verfasst von
Edward J. Silverman
Blair Ashley
Neil P. Sheth
Publikationsdatum
01.03.2016
Verlag
Springer US
Erschienen in
Current Reviews in Musculoskeletal Medicine / Ausgabe 1/2016
Elektronische ISSN: 1935-9748
DOI
https://doi.org/10.1007/s12178-016-9323-1

Weitere Artikel der Ausgabe 1/2016

Current Reviews in Musculoskeletal Medicine 1/2016 Zur Ausgabe

Shoulder Arthroplasty (G Athwal, Section Editor)

Expanding roles for reverse shoulder arthroplasty

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.