Skip to main content
Erschienen in: European Journal of Medical Research 3/2011

01.12.2011 | Research

Migration pattern of cementless press fit cups in the presence of stabilizing screws in total hip arthroplasty

verfasst von: C Zilkens, S Djalali, B Bittersohl, T Kälicke, CN Kraft, R Krauspe, M Jäger

Erschienen in: European Journal of Medical Research | Ausgabe 3/2011

Einloggen, um Zugang zu erhalten

Abstract

The aim of this study was to evaluate the initial acetabular implant stability and late acetabular implant migration in press fit cups combined with screw fixation of the acetabular component in order to answer the question whether screws are necessary for the fixation of the acetabular component in cementless primary total hip arthroplasty. One hundred and seven hips were available for follow-up after primary THA using a cementless, porous-coated acetabular component. A total of 631 standardized radiographs were analyzed digitally by the "single-film-x-ray-analysis" method (EBRA). One hundred 'and one (94.4%) acetabular components did not show significant migration of more than 1 mm. Six (5.6%) implants showed migration of more than 1 mm. Statistical analysis did not reveal preoperative patterns that would identify predictors for future migration. Our findings suggest that the use of screw fixation for cementless porous- coated acetabular components for primary THA does not prevent cup migration.
Literatur
1.
Zurück zum Zitat Roth A, Winzer T, Sander K, Anders JO, Venbrocks RA: Press fit fixation of cementless cups: how much stability do we need indeed? Arch Orthop Trauma Surg 2006,126(2):77–81. 10.1007/s00402-005-0001-9PubMedCrossRef Roth A, Winzer T, Sander K, Anders JO, Venbrocks RA: Press fit fixation of cementless cups: how much stability do we need indeed? Arch Orthop Trauma Surg 2006,126(2):77–81. 10.1007/s00402-005-0001-9PubMedCrossRef
2.
Zurück zum Zitat Dorr LD, Wan Z, Cohen J: Hemispheric titanium porous coated acetabular component without screw fixation. Clin Orthop Relat Res 1998,35(1):158–68. Dorr LD, Wan Z, Cohen J: Hemispheric titanium porous coated acetabular component without screw fixation. Clin Orthop Relat Res 1998,35(1):158–68.
3.
Zurück zum Zitat Valle AG, Zoppi A, Peterson MG, Salvati EA: Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty. J Bone Joint Surg Am 2004,86-A(9):1998–2004.PubMed Valle AG, Zoppi A, Peterson MG, Salvati EA: Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty. J Bone Joint Surg Am 2004,86-A(9):1998–2004.PubMed
4.
Zurück zum Zitat Engh CA, Hopper RH Jr, Engh CA Jr: Long-term porous-coated cup survivorship using spikes, screws, and press-fitting for initial fixation. J Arthroplasty 2004,19(7 SupplV):54–60.PubMedCrossRef Engh CA, Hopper RH Jr, Engh CA Jr: Long-term porous-coated cup survivorship using spikes, screws, and press-fitting for initial fixation. J Arthroplasty 2004,19(7 SupplV):54–60.PubMedCrossRef
5.
Zurück zum Zitat Massin P, Schmidt L, Engh CA: Evaluation of cementless acetabular component migration. An experimental study. J Arthroplasty 1989,4(3):245–51. 10.1016/S0883-5403(89)80020-8PubMedCrossRef Massin P, Schmidt L, Engh CA: Evaluation of cementless acetabular component migration. An experimental study. J Arthroplasty 1989,4(3):245–51. 10.1016/S0883-5403(89)80020-8PubMedCrossRef
6.
Zurück zum Zitat Iorio R, Puskas B, Healy WL, Tilzey JF, Specht LM, Thompson MS: Cementless Acetabular Fixation With and Without Screws Analysis of Stability and Migration. J Arthroplasty 2009, 19. Iorio R, Puskas B, Healy WL, Tilzey JF, Specht LM, Thompson MS: Cementless Acetabular Fixation With and Without Screws Analysis of Stability and Migration. J Arthroplasty 2009, 19.
7.
Zurück zum Zitat Wasielewski RC, Cooperstein LA, Kruger MP, Rubash HE: Acetabular anatomy and the transacetabular fixation of screws in total hip arthroplasty. J Bone Joint Surg Am 1990,72(4):501–8.PubMed Wasielewski RC, Cooperstein LA, Kruger MP, Rubash HE: Acetabular anatomy and the transacetabular fixation of screws in total hip arthroplasty. J Bone Joint Surg Am 1990,72(4):501–8.PubMed
8.
Zurück zum Zitat Archibeck MJ, Showalter D, Kavanaugh TS, Camarata D, White RE Jr: A comparison of cementless acetabular components of the same design: spiked versus supplemental screws. J Arthroplasty 2003,18(7 Suppl 1):122–5.PubMedCrossRef Archibeck MJ, Showalter D, Kavanaugh TS, Camarata D, White RE Jr: A comparison of cementless acetabular components of the same design: spiked versus supplemental screws. J Arthroplasty 2003,18(7 Suppl 1):122–5.PubMedCrossRef
9.
Zurück zum Zitat Kwong LM, O'Connor DO, Sedlacek RC, Krushell RJ, Maloney WJ, Harris WH: A quantitative in vitro assessment of fit and screw fixation on the stability of a cementless hemispherical acetabular component. J Arthroplasty 1994,9(2):1633–70.CrossRef Kwong LM, O'Connor DO, Sedlacek RC, Krushell RJ, Maloney WJ, Harris WH: A quantitative in vitro assessment of fit and screw fixation on the stability of a cementless hemispherical acetabular component. J Arthroplasty 1994,9(2):1633–70.CrossRef
10.
Zurück zum Zitat Thanner J, Karrholm J, Herberts P, Malchau H: Hydroxyapatite and tricalcium phosphate-coated cups with and without screw fixation: a randomized study of 64 hips. J Arthroplasty 2000,15(4):405–12. 10.1054/arth.2000.2963PubMedCrossRef Thanner J, Karrholm J, Herberts P, Malchau H: Hydroxyapatite and tricalcium phosphate-coated cups with and without screw fixation: a randomized study of 64 hips. J Arthroplasty 2000,15(4):405–12. 10.1054/arth.2000.2963PubMedCrossRef
11.
Zurück zum Zitat Udomkiat P, Dorr LD, Wan Z: Cementless hemispheric porous-coated sockets implanted with press-fit technique without screws: average ten-year follow-up. J Bone Joint Surg Am 2002,84-A(7):1195–200.PubMed Udomkiat P, Dorr LD, Wan Z: Cementless hemispheric porous-coated sockets implanted with press-fit technique without screws: average ten-year follow-up. J Bone Joint Surg Am 2002,84-A(7):1195–200.PubMed
12.
Zurück zum Zitat Schmalzried TP, Wessinger SJ, Hill GE, Harris WH: The Harris-Galante porous acetabular component press-fit without screw fixation. Five-year radiographic analysis of primary cases. J Arthroplasty 1994,9(3):235–42. 10.1016/0883-5403(94)90077-9PubMedCrossRef Schmalzried TP, Wessinger SJ, Hill GE, Harris WH: The Harris-Galante porous acetabular component press-fit without screw fixation. Five-year radiographic analysis of primary cases. J Arthroplasty 1994,9(3):235–42. 10.1016/0883-5403(94)90077-9PubMedCrossRef
13.
Zurück zum Zitat Torga Spak R, Stuchin SA: Cementless porous-coated sockets without holes implanted with pure press-fit technique. J Arthroplasty 2005,20(1):4–10. 10.1016/j.arth.2004.09.025PubMedCrossRef Torga Spak R, Stuchin SA: Cementless porous-coated sockets without holes implanted with pure press-fit technique. J Arthroplasty 2005,20(1):4–10. 10.1016/j.arth.2004.09.025PubMedCrossRef
14.
Zurück zum Zitat Healy WL, Iorio R, Lemos MJ, Patch DA, Pfeifer BA, Smiley PM, Wilk RM: Single Price/Case Price Purchasing in orthopaedic surgery: experience at the Lahey Clinic. J Bone Joint Surg 2000,82(5):607–12.PubMed Healy WL, Iorio R, Lemos MJ, Patch DA, Pfeifer BA, Smiley PM, Wilk RM: Single Price/Case Price Purchasing in orthopaedic surgery: experience at the Lahey Clinic. J Bone Joint Surg 2000,82(5):607–12.PubMed
15.
Zurück zum Zitat Wilkinson JM, Hamer AJ, Elson RA, Stockley I, Eastell R: Precision of EBRA-Digital software for monitoring implant migration after total hip arthroplasty. J Arthroplasty 2002,17(7):910–6. 10.1054/arth.2002.34530PubMedCrossRef Wilkinson JM, Hamer AJ, Elson RA, Stockley I, Eastell R: Precision of EBRA-Digital software for monitoring implant migration after total hip arthroplasty. J Arthroplasty 2002,17(7):910–6. 10.1054/arth.2002.34530PubMedCrossRef
16.
Zurück zum Zitat Phillips NJ, Stockley I, Wilkinson JM: Direct plain radiographic methods versus EBRA-Digital for measuring implant migration after total hip arthroplasty. J Arthroplasty 2002,17(7):917–25. 10.1054/arth.2002.34529PubMedCrossRef Phillips NJ, Stockley I, Wilkinson JM: Direct plain radiographic methods versus EBRA-Digital for measuring implant migration after total hip arthroplasty. J Arthroplasty 2002,17(7):917–25. 10.1054/arth.2002.34529PubMedCrossRef
17.
Zurück zum Zitat Ilchmann T, Kesteris U, Wingstrand H: EBRA improves the accuracy of radiographic analysis of acetabular cup migration. Acta Orthop Scand 1998,69(2):119–24. 10.3109/17453679809117610PubMedCrossRef Ilchmann T, Kesteris U, Wingstrand H: EBRA improves the accuracy of radiographic analysis of acetabular cup migration. Acta Orthop Scand 1998,69(2):119–24. 10.3109/17453679809117610PubMedCrossRef
18.
Zurück zum Zitat Krismer M, Bauer R, Tschupik J, Mayrhofer P: EBRA: a method to measure migration of acetabular components. J Biomech 1995,28(10):1225–336. 10.1016/0021-9290(94)00177-6PubMedCrossRef Krismer M, Bauer R, Tschupik J, Mayrhofer P: EBRA: a method to measure migration of acetabular components. J Biomech 1995,28(10):1225–336. 10.1016/0021-9290(94)00177-6PubMedCrossRef
19.
Zurück zum Zitat Ochs U, Ilchmann T, Ochs BG, Marx J, Brunnhuber K, Luem M, Weise K: EBRA migration patterns of the Plasmacup with ceramic or polyethylene inserts: a randomised study. Z Orthop Unfall 2007,145(Suppl 1):S20–4.PubMed Ochs U, Ilchmann T, Ochs BG, Marx J, Brunnhuber K, Luem M, Weise K: EBRA migration patterns of the Plasmacup with ceramic or polyethylene inserts: a randomised study. Z Orthop Unfall 2007,145(Suppl 1):S20–4.PubMed
20.
Zurück zum Zitat Langton DJ, Sprowson AP, Mahadeva D, Bhatnagar S, Holland JP, Nargol AV: Cup Anteversion in Hip Resurfacing: Validation of EBRA and the Presentation of a Simple Clinical Grading System. J Arthroplasty 2009, 17. Langton DJ, Sprowson AP, Mahadeva D, Bhatnagar S, Holland JP, Nargol AV: Cup Anteversion in Hip Resurfacing: Validation of EBRA and the Presentation of a Simple Clinical Grading System. J Arthroplasty 2009, 17.
21.
Zurück zum Zitat Klestil T, Biedermann R, Kruger A, Gfoller P, Schmoelz W, Rangger C, Krismer M, Blauth M: Cementless hemiarthroplasty in femoral neck fractures: evaluation of clinical results and measurement of migration by EBRA-FCA. Arch Orthop Trauma Surg 2006,126(6):380–6. 10.1007/s00402-006-0133-6PubMedCrossRef Klestil T, Biedermann R, Kruger A, Gfoller P, Schmoelz W, Rangger C, Krismer M, Blauth M: Cementless hemiarthroplasty in femoral neck fractures: evaluation of clinical results and measurement of migration by EBRA-FCA. Arch Orthop Trauma Surg 2006,126(6):380–6. 10.1007/s00402-006-0133-6PubMedCrossRef
22.
Zurück zum Zitat Ilchmann T, Gelzer JP, Winter E, Weise K: Acetabular reconstruction with the Burch-Schneider ring: an EBRA analysis of 40 cup revisions. Acta Orthop 2006,77(1):79–86. 10.1080/17453670610045722PubMedCrossRef Ilchmann T, Gelzer JP, Winter E, Weise K: Acetabular reconstruction with the Burch-Schneider ring: an EBRA analysis of 40 cup revisions. Acta Orthop 2006,77(1):79–86. 10.1080/17453670610045722PubMedCrossRef
23.
Zurück zum Zitat DeLee JG, Charnley J: Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 1976, 121: 20–32.PubMed DeLee JG, Charnley J: Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 1976, 121: 20–32.PubMed
24.
Zurück zum Zitat Ilchmann T, Mjoberg B, Wingstrand H: Measurement accuracy in acetabular cup wear. Three retrospective methods compared with Roentgen stereophotogrammetry. J Arthroplasty 1995,10(5):636–42. 10.1016/S0883-5403(05)80208-6PubMedCrossRef Ilchmann T, Mjoberg B, Wingstrand H: Measurement accuracy in acetabular cup wear. Three retrospective methods compared with Roentgen stereophotogrammetry. J Arthroplasty 1995,10(5):636–42. 10.1016/S0883-5403(05)80208-6PubMedCrossRef
25.
Zurück zum Zitat Schmalzried TP, Shepherd EF, Dorey FJ, Jackson WO, dela Rosa M, Fa'vae F, McKellop HA, McClung CD, Martell J, Moreland JR, Amstutz HC: The John Charnley Award. Wear is a function of use, not time. Clin Orthop Relat Res 2000, 381: 36–46.PubMedCrossRef Schmalzried TP, Shepherd EF, Dorey FJ, Jackson WO, dela Rosa M, Fa'vae F, McKellop HA, McClung CD, Martell J, Moreland JR, Amstutz HC: The John Charnley Award. Wear is a function of use, not time. Clin Orthop Relat Res 2000, 381: 36–46.PubMedCrossRef
26.
Zurück zum Zitat Morscher EW, Widmer KH, Bereiter H, Elke R, Schenk R: [Cementless socket fixation based on the "press-fit" concept in total hip joint arthroplasty]. Acta Chir Orthop Traumatol Cech 2002,69(1):8–15.PubMed Morscher EW, Widmer KH, Bereiter H, Elke R, Schenk R: [Cementless socket fixation based on the "press-fit" concept in total hip joint arthroplasty]. Acta Chir Orthop Traumatol Cech 2002,69(1):8–15.PubMed
27.
Zurück zum Zitat Rohrl SM, Nivbrant B, Strom H, Nilsson KG: Effect of augmented cup fixation on stability, wear, and osteolysis: a 5-year follow-up of total hip arthroplasty with RSA. J Arthroplasty 2004,19(8):962–71.PubMed Rohrl SM, Nivbrant B, Strom H, Nilsson KG: Effect of augmented cup fixation on stability, wear, and osteolysis: a 5-year follow-up of total hip arthroplasty with RSA. J Arthroplasty 2004,19(8):962–71.PubMed
28.
Zurück zum Zitat Won CH, Hearn TC, Tile M: Micromotion of cementless hemispherical acetabular components. Does press-fit need adjunctive screw fixation? J Bone Joint Surg Br 1995,77(3):484–9.PubMed Won CH, Hearn TC, Tile M: Micromotion of cementless hemispherical acetabular components. Does press-fit need adjunctive screw fixation? J Bone Joint Surg Br 1995,77(3):484–9.PubMed
29.
Zurück zum Zitat Schmalzried TP, Guttmann D, Grecula M, Amstutz HC: The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis. J Bone Joint Surg Am 1994,76(5):677–88.PubMed Schmalzried TP, Guttmann D, Grecula M, Amstutz HC: The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis. J Bone Joint Surg Am 1994,76(5):677–88.PubMed
Metadaten
Titel
Migration pattern of cementless press fit cups in the presence of stabilizing screws in total hip arthroplasty
verfasst von
C Zilkens
S Djalali
B Bittersohl
T Kälicke
CN Kraft
R Krauspe
M Jäger
Publikationsdatum
01.12.2011
Verlag
BioMed Central
Erschienen in
European Journal of Medical Research / Ausgabe 3/2011
Elektronische ISSN: 2047-783X
DOI
https://doi.org/10.1186/2047-783X-16-3-127

Weitere Artikel der Ausgabe 3/2011

European Journal of Medical Research 3/2011 Zur Ausgabe