Abstract

Over the past decade, there has been a dramatic increase in the number of patients undergoing prostate MRI scans. Patients presenting for prostate MRI are an ageing population and may present with a variety of passive or active implants and devices. These implants and devices can be MR safe or MR conditional or MR unsafe. Patients with certain MR-conditional active implants and devices can safely obtain prostate MRI in a specified MR environment within specific MR imaging parameters. Prostate MRI and PET-MRI in patients with passive implants such as hip prostheses, fiducial markers for SBRT, brachytherapy seeds and prostatectomy bed clips have unique concerns for image optimization that can cause geometric distortion of the diffusion-weighted imaging (DWI) sequence. We discuss strategies to overcome these susceptibility artifacts. Prostate MRI in patients with MR conditional active implants such as cardiac implantable electronic devices (CIED) also require modification of imaging parameters and magnet strength. In this setting, a diagnostic quality prostate MRI can be performed at a lower magnet strength (1.5 T) along with modification of imaging parameters to ensure patient safety. Imaging strategies to minimize susceptibility artifact and decrease the specific absorption rate (SAR) in both settings are described. Knowledge of MR safety considerations and imaging strategies specific to prostate MRI and PET-MRI in patients with implants and devices is essential to ensure diagnostic-quality MR images and patient safety.
Literatur
1.
Zurück zum Zitat Gupta, R.T., et al., PI-RADS: Past, present, and future. J Magn Reson Imaging, 2019. Gupta, R.T., et al., PI-RADS: Past, present, and future. J Magn Reson Imaging, 2019.
2.
Zurück zum Zitat Weinreb, J.C., et al., PI-RADS Prostate Imaging - Reporting and Data System: 2015, Version 2. Eur Urol, 2016. 69(1): p. 16-40. Weinreb, J.C., et al., PI-RADS Prostate Imaging - Reporting and Data System: 2015, Version 2. Eur Urol, 2016. 69(1): p. 16-40.
3.
Zurück zum Zitat Czarniecki, M., et al., Role of PROPELLER-DWI of the prostate in reducing distortion and artefact from total hip replacement metalwork. Eur J Radiol, 2018. 102: p. 213-219. Czarniecki, M., et al., Role of PROPELLER-DWI of the prostate in reducing distortion and artefact from total hip replacement metalwork. Eur J Radiol, 2018. 102: p. 213-219.
4.
Zurück zum Zitat Tanaka, T., et al., Safety and Image Quality of 1.5-T Endorectal Coil Multiparametric MRI of the Prostate or Prostatectomy Fossa for Patients With Pacemaker or Implantable Cardioverter-Defibrillator. AJR Am J Roentgenol, 219. 212(4): p. 815-822. Tanaka, T., et al., Safety and Image Quality of 1.5-T Endorectal Coil Multiparametric MRI of the Prostate or Prostatectomy Fossa for Patients With Pacemaker or Implantable Cardioverter-Defibrillator. AJR Am J Roentgenol, 219. 212(4): p. 815-822.
5.
Zurück zum Zitat Ullrich, T., et al., Magnetic resonance imaging of the prostate at 1.5 versus 3.0T: A prospective comparison study of image quality. Eur J Radiol, 2017. 90: p. 192-197. Ullrich, T., et al., Magnetic resonance imaging of the prostate at 1.5 versus 3.0T: A prospective comparison study of image quality. Eur J Radiol, 2017. 90: p. 192-197.
6.
Zurück zum Zitat Shellock, F.G., T.O. Woods, and J.V. Crues, 3rd, MR labeling information for implants and devices: explanation of terminology. Radiology, 2009. 253(1): p. 26-30. Shellock, F.G., T.O. Woods, and J.V. Crues, 3rd, MR labeling information for implants and devices: explanation of terminology. Radiology, 2009. 253(1): p. 26-30.
7.
Zurück zum Zitat Shellock, F.G. and A. Spinazzi, MRI safety update 2008: part 2, screening patients for MRI. AJR Am J Roentgenol, 2008. 191(4): p. 1140-9. Shellock, F.G. and A. Spinazzi, MRI safety update 2008: part 2, screening patients for MRI. AJR Am J Roentgenol, 2008. 191(4): p. 1140-9.
8.
Zurück zum Zitat Lowe, G., R.P. Smith, and R.A. Costabile, A catalog of magnetic resonance imaging compatibility of penile prostheses. J Sex Med, 2012. 9(5): p. 1482-7. Lowe, G., R.P. Smith, and R.A. Costabile, A catalog of magnetic resonance imaging compatibility of penile prostheses. J Sex Med, 2012. 9(5): p. 1482-7.
9.
Zurück zum Zitat Panych, L.P. and B. Madore, The physics of MRI safety. J Magn Reson Imaging, 2018. 47(1): p. 28-43. Panych, L.P. and B. Madore, The physics of MRI safety. J Magn Reson Imaging, 2018. 47(1): p. 28-43.
10.
Zurück zum Zitat Shellock, F.G. and J.V. Crues, MR procedures: biologic effects, safety, and patient care. Radiology, 2004. 232(3): p. 635-52. Shellock, F.G. and J.V. Crues, MR procedures: biologic effects, safety, and patient care. Radiology, 2004. 232(3): p. 635-52.
11.
Zurück zum Zitat Graf, H., G. Steidle, and F. Schick, Heating of metallic implants and instruments induced by gradient switching in a 1.5-Tesla whole-body unit. J Magn Reson Imaging, 2007. 26(5): p. 1328-33. Graf, H., G. Steidle, and F. Schick, Heating of metallic implants and instruments induced by gradient switching in a 1.5-Tesla whole-body unit. J Magn Reson Imaging, 2007. 26(5): p. 1328-33.
13.
Zurück zum Zitat Dedini, R.D., et al., MRI issues for ballistic objects: information obtained at 1.5-, 3- and 7-Tesla. Spine J, 2013. 13(7): p. 815-22. Dedini, R.D., et al., MRI issues for ballistic objects: information obtained at 1.5-, 3- and 7-Tesla. Spine J, 2013. 13(7): p. 815-22.
14.
Zurück zum Zitat Maradit Kremers, H., et al., Prevalence of Total Hip and Knee Replacement in the United States. J Bone Joint Surg Am, 2015. 97(17): p. 1386-97. Maradit Kremers, H., et al., Prevalence of Total Hip and Knee Replacement in the United States. J Bone Joint Surg Am, 2015. 97(17): p. 1386-97.
15.
Zurück zum Zitat Talbot, B.S. and E.P. Weinberg, MR Imaging with Metal-suppression Sequences for Evaluation of Total Joint Arthroplasty. Radiographics, 2016. 36(1): p. 209-25. Talbot, B.S. and E.P. Weinberg, MR Imaging with Metal-suppression Sequences for Evaluation of Total Joint Arthroplasty. Radiographics, 2016. 36(1): p. 209-25.
16.
Zurück zum Zitat Zhuo, J. and R.P. Gullapalli, AAPM/RSNA physics tutorial for residents: MR artifacts, safety, and quality control. Radiographics, 2006. 26(1): p. 275-97. Zhuo, J. and R.P. Gullapalli, AAPM/RSNA physics tutorial for residents: MR artifacts, safety, and quality control. Radiographics, 2006. 26(1): p. 275-97.
17.
Zurück zum Zitat Engels, R.R.M., et al., Multiparametric Magnetic Resonance Imaging for the Detection of Clinically Significant Prostate Cancer: What Urologists Need to Know. Part 1: Acquisition. Eur Urol, 2020. 77(4): p. 457-468. Engels, R.R.M., et al., Multiparametric Magnetic Resonance Imaging for the Detection of Clinically Significant Prostate Cancer: What Urologists Need to Know. Part 1: Acquisition. Eur Urol, 2020. 77(4): p. 457-468.
18.
Zurück zum Zitat Fusco, R., et al., A systematic review on multiparametric MR imaging in prostate cancer detection. Infect Agent Cancer, 2017. 12: p. 57. Fusco, R., et al., A systematic review on multiparametric MR imaging in prostate cancer detection. Infect Agent Cancer, 2017. 12: p. 57.
19.
Zurück zum Zitat Starobinets, O., et al., Practical aspects of prostate MRI: hardware and software considerations, protocols, and patient preparation. Abdom Radiol (NY), 2016. 41(5): p. 817-30. Starobinets, O., et al., Practical aspects of prostate MRI: hardware and software considerations, protocols, and patient preparation. Abdom Radiol (NY), 2016. 41(5): p. 817-30.
20.
Zurück zum Zitat Rosenkrantz, A.B. and S.S. Taneja, Use of Reduced Field-of-View Acquisition to Improve Prostate Cancer Visualization on Diffusion-Weighted Magnetic Resonance Imaging in the Presence of Hip Implants: Report of 2 Cases. Curr Probl Diagn Radiol, 2018. 47(2): p. 125-127. Rosenkrantz, A.B. and S.S. Taneja, Use of Reduced Field-of-View Acquisition to Improve Prostate Cancer Visualization on Diffusion-Weighted Magnetic Resonance Imaging in the Presence of Hip Implants: Report of 2 Cases. Curr Probl Diagn Radiol, 2018. 47(2): p. 125-127.
21.
Zurück zum Zitat Zand, K.R., et al., Artifacts and pitfalls in MR imaging of the pelvis. J Magn Reson Imaging, 2007. 26(3): p. 480-97. Zand, K.R., et al., Artifacts and pitfalls in MR imaging of the pelvis. J Magn Reson Imaging, 2007. 26(3): p. 480-97.
22.
Zurück zum Zitat Kudura, K., et al., Metal artifact reduction in 68Ga-PSMA-11 PET/MRI for prostate cancer patients with hip joint replacement using multiacquisition variable-resonance image combination. European Journal of Hybrid Imaging, 2020. 4(1). Kudura, K., et al., Metal artifact reduction in 68Ga-PSMA-11 PET/MRI for prostate cancer patients with hip joint replacement using multiacquisition variable-resonance image combination. European Journal of Hybrid Imaging, 2020. 4(1).
23.
Zurück zum Zitat Oppenheimer, D.C., et al., Multiparametric Magnetic Resonance Imaging of Recurrent Prostate Cancer. J Clin Imaging Sci, 2016. 6: p. 18. Oppenheimer, D.C., et al., Multiparametric Magnetic Resonance Imaging of Recurrent Prostate Cancer. J Clin Imaging Sci, 2016. 6: p. 18.
24.
Zurück zum Zitat Gaur, S. and B. Turkbey, Prostate MR Imaging for Posttreatment Evaluation and Recurrence. Radiol Clin North Am, 2018. 56(2): p. 263-275. Gaur, S. and B. Turkbey, Prostate MR Imaging for Posttreatment Evaluation and Recurrence. Radiol Clin North Am, 2018. 56(2): p. 263-275.
25.
Zurück zum Zitat Blanchard, P., C. Menard, and S.J. Frank, Clinical use of magnetic resonance imaging across the prostate brachytherapy workflow. Brachytherapy, 2017. 16(4): p. 734-742. Blanchard, P., C. Menard, and S.J. Frank, Clinical use of magnetic resonance imaging across the prostate brachytherapy workflow. Brachytherapy, 2017. 16(4): p. 734-742.
26.
Zurück zum Zitat Holmes, O.E., et al., Reducing errors in prostate tracking with an improved fiducial implantation protocol for CyberKnife based stereotactic body radiotherapy (SBRT). J Radiosurg SBRT, 2018. 5(3): p. 217-227. Holmes, O.E., et al., Reducing errors in prostate tracking with an improved fiducial implantation protocol for CyberKnife based stereotactic body radiotherapy (SBRT). J Radiosurg SBRT, 2018. 5(3): p. 217-227.
27.
Zurück zum Zitat Maspero, M., et al., Evaluation of gold fiducial marker manual localisation for magnetic resonance-only prostate radiotherapy. Radiat Oncol, 2018. 13(1): p. 105. Maspero, M., et al., Evaluation of gold fiducial marker manual localisation for magnetic resonance-only prostate radiotherapy. Radiat Oncol, 2018. 13(1): p. 105.
28.
Zurück zum Zitat Safety, A.C.R.C.o.M., et al., ACR guidance document on MR safe practices: Updates and critical information 2019. J Magn Reson Imaging, 2020. 51(2): p. 331-338. Safety, A.C.R.C.o.M., et al., ACR guidance document on MR safe practices: Updates and critical information 2019. J Magn Reson Imaging, 2020. 51(2): p. 331-338.
29.
Zurück zum Zitat Levine, G.N., et al., Safety of magnetic resonance imaging in patients with cardiovascular devices: an American Heart Association scientific statement from the Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and Intervention: endorsed by the American College of Cardiology Foundation, the North American Society for Cardiac Imaging, and the Society for Cardiovascular Magnetic Resonance. Circulation, 2007. 116(24): p. 2878-91. Levine, G.N., et al., Safety of magnetic resonance imaging in patients with cardiovascular devices: an American Heart Association scientific statement from the Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and Intervention: endorsed by the American College of Cardiology Foundation, the North American Society for Cardiac Imaging, and the Society for Cardiovascular Magnetic Resonance. Circulation, 2007. 116(24): p. 2878-91.
30.
Zurück zum Zitat Shellock, F.G. and S. Valencerina, Septal repair implants: evaluation of magnetic resonance imaging safety at 3 T. Magn Reson Imaging, 2005. 23(10): p. 1021-5. Shellock, F.G. and S. Valencerina, Septal repair implants: evaluation of magnetic resonance imaging safety at 3 T. Magn Reson Imaging, 2005. 23(10): p. 1021-5.
31.
Zurück zum Zitat Tsai, L.L., et al., A Practical Guide to MR Imaging Safety: What Radiologists Need to Know. Radiographics, 2015. 35(6): p. 1722-37. Tsai, L.L., et al., A Practical Guide to MR Imaging Safety: What Radiologists Need to Know. Radiographics, 2015. 35(6): p. 1722-37.
32.
Zurück zum Zitat Kalb, B., et al., MRI of patients with implanted cardiac devices. J Magn Reson Imaging, 2018. 47(3): p. 595-603. Kalb, B., et al., MRI of patients with implanted cardiac devices. J Magn Reson Imaging, 2018. 47(3): p. 595-603.
33.
Zurück zum Zitat Indik, J.H., et al., 2017 HRS expert consensus statement on magnetic resonance imaging and radiation exposure in patients with cardiovascular implantable electronic devices. Heart Rhythm, 2017. 14(7): p. e97-e153. Indik, J.H., et al., 2017 HRS expert consensus statement on magnetic resonance imaging and radiation exposure in patients with cardiovascular implantable electronic devices. Heart Rhythm, 2017. 14(7): p. e97-e153.
34.
Zurück zum Zitat Naehle, C.P., et al., Safety of brain 3-T MR imaging with transmit-receive head coil in patients with cardiac pacemakers: pilot prospective study with 51 examinations. Radiology, 2008. 249(3): p. 991-1001. Naehle, C.P., et al., Safety of brain 3-T MR imaging with transmit-receive head coil in patients with cardiac pacemakers: pilot prospective study with 51 examinations. Radiology, 2008. 249(3): p. 991-1001.
35.
Zurück zum Zitat Gimbel, J.R., Magnetic resonance imaging of implantable cardiac rhythm devices at 3.0 tesla. Pacing Clin Electrophysiol, 2008. 31(7): p. 795-801. Gimbel, J.R., Magnetic resonance imaging of implantable cardiac rhythm devices at 3.0 tesla. Pacing Clin Electrophysiol, 2008. 31(7): p. 795-801.
36.
Zurück zum Zitat Russo, R.J., et al., Assessing the Risks Associated with MRI in Patients with a Pacemaker or Defibrillator. N Engl J Med, 2017. 376(8): p. 755-764. Russo, R.J., et al., Assessing the Risks Associated with MRI in Patients with a Pacemaker or Defibrillator. N Engl J Med, 2017. 376(8): p. 755-764.
38.
Zurück zum Zitat Rosenkrantz, A.B., et al., T2-weighted prostate MRI at 7 Tesla using a simplified external transmit-receive coil array: correlation with radical prostatectomy findings in two prostate cancer patients. J Magn Reson Imaging, 2015. 41(1): p. 226-32. Rosenkrantz, A.B., et al., T2-weighted prostate MRI at 7 Tesla using a simplified external transmit-receive coil array: correlation with radical prostatectomy findings in two prostate cancer patients. J Magn Reson Imaging, 2015. 41(1): p. 226-32.
Metadaten
Titel
MR safety considerations for patients undergoing prostate MRI
verfasst von
Varaha S. Tammisetti
Publikationsdatum
09.09.2020
Verlag
Springer US
Erschienen in
Abdominal Radiology / Ausgabe 12/2020
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-020-02730-0

Weitere Artikel der Ausgabe 12/2020

Abdominal Radiology 12/2020 Zur Ausgabe

Special Section: Prostate cancer update

Education of prostate MR imaging: commentary

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.