Skip to main content
Erschienen in: Cardiovascular Ultrasound 1/2007

Open Access 01.12.2007 | Research

Noninvasive monitoring of myocardial function after surgical and cytostatic therapy in a peritoneal metastasis rat model: assessment with tissue Doppler and non-Doppler 2D strain echocardiography

verfasst von: Jens Hartmann, Fabian Knebel, Stephan Eddicks, Mark Beling, Andrea Grohmann, Alexander Panda, Christoph A Jacobi, Joachim M Müller, Klaus-Dieter Wernecke, Gert Baumann, Adrian C Borges

Erschienen in: Cardiovascular Ultrasound | Ausgabe 1/2007

Abstract

Objective

We sought to evaluate the impact of different antineoplastic treatment methods on systolic and diastolic myocardial function, and the feasibility estimation of regional deformation parameters with non-Doppler 2D echocardiography in rats.

Background

The optimal method for quantitative assessment of global and regional ventricular function in rats and the impact of complex oncological multimodal therapy on left- and right-ventricular function in rats remains unclear.

Methods

90 rats after subperitoneal implantation of syngenetic colonic carcinoma cells underwent different onclogical treatment methods and were diveded into one control group and five treatment groups (with 15 rats in each group): group 1 = control group (without operation and without medication), group 2 = operation group without additional therapy, group 3 = combination of operation and photodynamic therapy, group 4 = operation in combination with hyperthermic intraoperative peritoneal chemotherapy with mitomycine, and group 5 = operation in combination with hyperthermic intraoperative peritoneal chemotherapy with gemcitabine, group 6 = operation in combination with taurolidin i.p. instillation. Echocardiographic examination with estimation of wall thickness, diameters, left ventricular fractional shortening, ejection fraction, early and late diastolic transmitral and myocardial velocities, radial and circumferential strain were performed 3–4 days after therapy.

Results

There was an increase of LVEDD and LVESD in all groups after the follow-up period (P = 0.0037). Other LV dimensions, FS and EF as well as diastolic mitral filling parameters measured by echocardiography were not significantly affected by the different treatments. Values for right ventricular dimensions and function remained unchanged, whereas circumferential 2D strain of the inferior wall was slightly, but significantly reduced under the treatment (-18.1 ± 2.5 before and -16.2 ± 2.9 % after treatment; P = 0.001) without differences between the single treatment groups.

Conclusion

It is feasible to assess dimensions, global function, and regional contractility with echocardiography in rats under different oncological therapy. The deformation was decreased under overall treatment without influence by one specific therapy. Therefore, deformation assessment with non-Doppler 2D strain echocardiography is more sensitive than conventional echocardiography for assessing myocardial dysfunction in rats under oncological treatment.
Hinweise

Electronic supplementary material

The online version of this article (doi:10.​1186/​1476-7120-5-23) contains supplementary material, which is available to authorized users.

Competing interests

The author(s) declare that they have no competing interests.

Authors' contributions

JH, FK and ACB have designed and performed the study and have written the manuscript. JH and FK have equally contributed to this study. JH, FK, ACB SE, MB, AG, AP, GB have performed echocardiographic measurements and participated in the study design and coordination. JH, CJ and JM have performed the oncological and surgical therapy. KW has supported the statistical analysis of the study. All authors have read and approved the final manuscript.
Abkürzungen
LV
left ventricular
ECG
electrocardiogram
pw- Doppler
pulsed wave Doppler
LVEF
left ventricular ejection fraction
2D
two-dimensional
TDI
tissue Doppler imaging
SR
strain rate
ROI
region of interest

Background

Clinical echocardiography has been established as a safe, reproducible, and accurate assessment of cardiac anatomy, hemodynamics, and cardiac function. Commercially available ultrasound imaging systems are capable of resolution approaching that of magnetic resonance imaging as a result of recent computer and transducer technology. Understandably, there is increasing interest in using echocardiography as a basic research tool with standard laboratory animals. Knowledge of baseline normal values in commonly used rat species are limited [1, 2]. Previous experimental studies could give some information about right and left ventricular contractility in sheep, pigs and dogs for with new technologies of 2D strain and tissue Doppler imaging [2]. Echocardiography has become widely used to evaluate cardiac function in animal models of cardiac diseases. Because of its non-invasive character, echocardiography allows serial in vivo evaluation of cardiac dimensions, ejection fraction, and diastolic parameters. New oncological complex therapeutic modalities have the potential to affect cardiovascular hemodynamics, preload, afterload, myocardial contractility, and may induce acute and chronic cardiac impairment. Therefore, these new therapy options have the potential to significantly alter echocardiographic parameters. There is limited knowledge about the impact of the combination of surgery, hyperthermia, and cytostatic therapy in sick rats. Knowledge of baseline echocardiographic (incl. tissue Doppler values and 2D echocardiography) normal values and changes under surgical and cytostatic therapy in an animal model with peritoneal metastasis would be worthwhile. This study was performed to assess the differential impact of different types and combinations of complex oncological therapy methods in rats with peritoneal metastasis.

Methods

Animal Preparation

All animal studies were performed in accordance with guidelines for the care and use of laboratory animals at our institutions. 90 male BDIX/HansHsd rats with a body weight between 227 and 312 g were obtained from a single breeding colony (Harlan Winkelmann, Borchen). Animals were individually housed and followed free access to standard laboratory food and water ad libitum and 12 hours of light per day. Maintance and care were carried out according to the guidelines of the local Animal Protection Commission. This protocol was approved by our local animal protection committee.
A new multimodal treatment system in tumor bearing rats was tested. For this purpose 2 × 105 syngenetic colonic carcinoma cells (DHD/K12/TRb) were implanted subperitoneal in right upper quadrant in male BDIX rats by a median mini-laparotomy under general i.p. anesthesia. After implantation rats were randomized into 6 groups (5 treatment groups, 1 control group). There were 15 rats in every group. 21 days after tumor implantation all animals of the treatment groups were operated by a standard median laparotomy under general i.p. anesthesia from 6 cm and tumor spread was analysed. After that, we created a surgical tumour debulking with the aim of complete tumour removal in all animals. 4 groups underwent an additional treatment like Hyperthermic Intraoperative Peritoneal Chemotherapy (HIPEC) with mitomycine (15 mg/m2 body surface area) or with gemcitabine (24 mg/kg body weight) (group 1 and 2, respectively), Photodynamic Therapy (PDT) (group 3), taurolidine i.p. instillation (group 4). The rats of one group underwent only surgical debulking (group 5). 21 days after the surgical procedure all animals were sacrified in CO2 chamber and tumor weight, ascites volume and tumor spread, classified by a modified Peritoneal Cancer Index (PCI) were assessed by two independent observers.
The rats were anesthetized with xylazine (3.7 mg/kg i.p.) and ketamine (66.5 mg/kg i.p.), the anaesthesia was maintained throughout the echocardiographic examination, and electrocardiography was continuously monitored from limb leads. Animals were considered sufficiently anesthetized when they became totally unresponsive to a moderate pain stimulus while still normally breathing spontaneously (absence of respiratory depression, animals were not intubated). The anterior chest was shaved and the rats were postioned in left lateral decubitus position during image acquisition.

Echocardiographic examination

Echocardiographic studies were performed (VIVID 7 dimension system; General Electric-Vingmed Ultrasound, Horton Norway). Images were obtained using a 10S transducer (5.5–12 MHz) with high temporal and spatial resolution. The transducer was placed directly on the chest wall. A complete 2-dimensional, M-mode (according to standards of American Society of Echocardiography), and color and tissue Doppler echocardiogram was performed under anesthesia.
Using a zoomed image window, color Doppler myocardial velocity data were acquired at a frame rate of 205–230 frames/s, a sector angle of 30 degrees, and a image depth of 15 mm. Beam focus was set at 10 mm. Digital data of 5 consecutive heart cycles were recorded and transferred to a personal computer workstation for offline analysis.
Circumferential 2D strain was calculated from the parasternal short axis view (anterior septal and inferior mid wall). For radial contractility measurements, strain profiles were analyzed on the inferior and anterior myocardium. Peak systolic strain values were measured in each of 5 heart cycles. The maximal and minimal values were discarded, and the remaining 3 values were averaged. We did not measure strain rate with the speckle tracking method because of the too low temporal resolution and the smoothing of the curves of this method.
Systolic 2-dimensional strain (reflects relative longitudinal shortening = negative values, and longitudinal elongation or stretching = positive values, compared with end diastole in %), and strain rate (reflects the velocity of strain change) were calculated with the new software for echocardiographic quantification as previously described, based on real-time tracking of natural acoustic marker during two consecutive frames by 2-dimensional strain software. In addition, myocardial velocities with estimation of longitudinal displacement (systolic time velocity integral), strain, strain rate, and acceleration during isovolumic contraction were measured in the same segments with conventional TDE [3].
Images and offline reconstructed 2D strain images were compared for each individual rat and interpreted by two investigators, blinded to experimental information and timing of the studies. 2D strain and strain rate were calculated as previously described [4].

Data analysis

The RV morphology was assessed as RV end-diastolic diameter (RVEDD). To assess RV function, the base-to-apex shortening during systole, measured as the tricuspid annular plane systolic excursion (TAPSE) of the lateral portion of the tricuspid annular plane, was recorded in the M-mode format under 2D echocardiographic guidance from the apical 4-chamber view.
Radial and longitudinal myocardial strain rate and strain were calculated from color Doppler velocity data using special software (Echo Pac, GE Medical Systems) as previously described [5].
For analysis, rats divided into two groups: group A with potential cardiotoxic therapy (group 1 and 2) and group B with non-cardiotoxic therapy (group 3–5).

Statistical analysis

Values are expressed as mean ± standard deviation (SD) unless indicated otherwise. Groups were compared by parametric or non-parametric tests (t-tests and Wilcoxon-Mann-Whitney tests, resp.). More than 2 groups were analysed using ANOVA (symmetrically distributed observations) or Kruskal-Wallis test (otherwise). Post-hoc tests were performed (if significant differences were proved globally) with the help of multiple tests or pair-wise comparisons (with the same error of the 1st kind in 3 groups – closed test procedure). Categorical data were tested by means of Fisher's exact test, in particular differences in sensitivity, specificity and accuracy. Proceeding on the assumption that SR measurements are independent from tethering effects of adjunctive segments we choose the segment as statistical unity in the corresponding tests. Simple linear regression, intra-class correlation and Kappa were used for measurement comparisons.
Because of the fact that the calculated p-values are to be understood as explorative ones, no adjustments for multiple testing were made. Additionally, no generalisation of the results can be undertaken, particularly not in the sense of superiority.

Results

Feasibility

Echocardiographic measurements were possible in all rats before and after treatment. All animals survived and we did not encounter any hemodynamic or respiratory instability or arrhythmias during sedation, examination, oncological treatment or follow-up.

Effects of oncological treatment

The heart rate after follow-up was higher in the control group (235 ± 34 vs 274 ± 47 bpm; P = 0.006), whereas it remained unchanged in rats of the treatment group (groups 2–6) 231 ± 17 vs 185 ± 27 bpm; P = 0.62).
The hemodynamic effects in normal animals as well as in the different treatment groups are summarized in Table 1, 2, 3. There was an increase of LVEDD and LVESD in all groups after the follow-up period (P = 0.0037). Other LV dimensions, FS and EF measured by echocardiography were not significantly affected by the different treatments. Diastolic mitral filling parameters and myocardial velocities were not significantly affected by the type of treatment (figures 1+2). Values for right ventricular dimensions and function (TAPSE) remained unchanged under treatment and there were no differences between the groups (see figures 1, 2, 3, 4, 5, 6, 7)
Table 1
Characteristics and echocardiographic data of the study animals
 
Group 2–6 before/after therapy
Group 1
Group 2
Group 3
Group 4
Group 5
Group 6
Body mass – g
       
   Mean
275
282
267
288
269
275
274
   SD
23
26
24
25
24
20
23
   Range
227–312
258–318
227–287
247–312
235–306
237–291
235–312
Heart rate – bpm
       
   Mean
263/261
265/274*
260/253
277/260
260/253
260/265
259/268
   SD
17/27
11/11
21/29
12/22
20/38
18/23
14/27
   Range
231–289/185–311
223–249/215–287
244–288/221–296
256–288/234–298
235–289/185 – 289
245–289/234 – 300
231–278/221–311
Enddiastolic diameter-mm
       
   Mean
7/7.2*
6.9/7.2*
6.7/7.1*
7.6/7.8
6.6/6.8
7.1/7.3
6.8/7.1
   SD
0.7/0.6
0.64/0.62
0.67/0.43
0.29/0.53
0.17/0.84
0.25/0.30
0.7/0.4
   Range
5.0–8.1/5.5–8.7
6.3–7.8/6.5–7.9
6.0–7.8/6.4 – 7.6
7.3–8.1/7.1 – 8.7
5.0–7.4/5.5 – 7.3
6.8–7.6/6.9–7.8
5.4–7.6/6.5–7.9
Endsystolic diameter- mm
       
   Mean
2.8/3.1*
2.7/3.0*
2.6/3.0*
2.7/3.3
2.5/2.7
2.6/2.8
2.5/2.7
   SD
0.6/0.7
0.6/0.67
0.56/0.65
0.54/0.62
0.4/0.45
0.37/0.34
0.34/0.27
   Range
2.1–4.1/2.1–4.0
2.2 – 4.0/2.3–4.1
2.3 – 4.1/2.4 – 4.2
2.5–4.1/2.6–4.0
2.2–4.0/2.3–4.1
2.3 – 4.1/2.2–4.1
2.3–4.0/2.3–4.1
Enddiastolic septal wall-mm
       
   Mean
1.3/1.3
1.3/1.3
1.3/1.2
1.2/1.2
1.6/1.5
1.2/1,2
1.4/1.4
   SD
0.20/0.22
0.14/0.09
0.3/0.11
0.08/0.10
0.23/0.17
0.08/0.05
0.33/0.33
   Range
1–2.0/1.1–2.0
1.2–1.5/1.2–1.4
1.1–1.8/1.1–1.4
1.1–1.3/1.1–1.4
1.3 – 2.0/1.2 – 1.7
1.1–1.3/1.1 – 1.2
1.0 – 1.9/1.1–1.4
Enddiastolic inferior wall-mm
       
   Mean
1.4/1.4
1.22/1.3
1.48/1.28
1.25/1.30
1.6/1.6
1.2/1.2
1.4/1.5
   SD
0.3/0.3
0.09/0.14
0.2/0.1
0.10/0.12
0.41/0.51
0.13/0.082
0.27/0.38
   Range
1.1–2.3/1.1–2.6
1.1–1.3/1.1–1.4
1.2 – 2.2/1.1.-1.4
1.1–1.4/1.1–1.4
1.2 – 2.3/1.2 – 2.6
1.1–1.4/1.1 – 1.3
1.1–1.9/1.2–2.3
Fractional shortening-%
       
   Mean
36.6/37.1
35.0/36.5
36.2/35.0
33.0/33.8
40. 0/43.2
34/35
39/38
   SD
4.9/5.2
1.5/1.5
3.5/2.7
1.8/2.2
5.2/6.1
2.5/2.3
6.3/5.5
   Range
31–52/31–53
34–36/35–38
34–42/32–39
32–34/31–37
34–47/37–53
31–37/32 – 38
32–52/31–45
Left ventricular ejection fraction-%
       
   Mean
73/74
71/72
71/70
74/74
75/78
71/72
74/74
   SD
5/4
2/4
5/3.5
2.5/2.1
6.7 – 6.9
1.7/2.5
7.3/4.9
   Range
62–87/66–88
68–73/66 – 75
67 – 79/66–75
71–78/71–76
67 – 83/70 – 88
68 – 73/69–74
62–87/67–81
Right ventricular enddiastolic diameter-mm
       
   Mean
3.4/3.5
3.5/3.6
3.4/3.6
3.4/3.7
3.34/3.45
3.3/3.5
3.2/3.4
   SD
0.16/0.14
0.14/0.13
0.22/0.21
0.21/0.23
0.16/0.21
0.21/0.22
0.19/0.22
   Range
3.3 – 4.0/3.5 – 4.1
3.4–4.1/3.4 – 4.3
3.3–4.0/3.2 – 4.3
3.4–4.1/3.3 – 4.3
3.4–4.1/3.2–4.3
3.2–3.9/3.4 – 4.1
3.4 – 3.9/3.4 – 4.1
Tricuspid annular plane Systolic excursion (TAPSE)-mm
       
   Mean
1.9/1.9
1.85/1.82
1.94/1.86
1.88/1.95
1.88/1.95
1.9/1.9
1.91/1.92
   SD
0.12/0.11
0.17/0.10
0.16/0.11
0.13/0.08
0.13/0.09
0.11/0.09
0.09/0.14
   Range
1.7 – 2.2/1.7–2.1
1.7 – 2.1/1.7 – 1.9
1.8–2.2/1.7–2.0
1.7–2.1/1.8–2.0
1.7–2.1/1.8–2.0
1.7–2.0/1.8–2.0
1.8–2.0/1.7–2.1
Group 1 = control group (without operation and without medication)
Group 2 = operation group without additional therapy
Group 3 = combination of operation and photodynamic therapy
Group 4 = operation in combination with hyperthermic intraoperative peritoneal chemotherapy with mitomycine
Group 5 = operation in combination with hyperthermic intraoperative peritoneal chemotherapy with gemcitabine
Group 6 = operation in combination with taurolidin i.p. instillation;
* P < 0.05; ** P < 0.001
Table 2
Diastolic function parameters
 
Group 2–6 Before/after therapy
Group 1
Group 2
Group 3
Group 4
Group 5
Group 6
E-wave – cm/s
       
   Mean
76/75
73/76
71.8/71.6
78/78.7
78/70.3
75.8/72.3
75.6/79.0
   SD
7.6/10.2
4.2/2.8
4.0/4.0
8.3/8.2
10.5/10.1
7.6/8.6
7.1/14.1
   Range
66 – 98/57–101
69 – 78/72–78
66–76/68–78
68–88/69–88
69–98/57–87
69–88/66–89
68–87/67–101
A-wave- cm/s
       
   Mean
45/52
42/42
43.6/44.4
47.3/45.7
45/44
46/45
45.2/47.3
   SD
5.0/6.4
5.1/6.1
5.9/6.2
6.3/8.3
4/3.7
4.8/2.7
5.1/5.4
   Range
35 – 57/31 – 64
34–45/35 – 50
35–50/35–51
40–56/34–56
40–50/43–45
41–51/41–49
41–57/31–48
E/A ratio
       
   Mean
1.69/1.69
1.78/1.83
1.67/1.63
1.68/1.76
1.77/1.59
1.66/1.60
1.68/1.81
   SD
0.27/0.47
0.34/0.29
0.23/0.21
0.33/0.33
0.36/0.23
0.25/0.22
0.21/0.18
   Range
1.29 – 2.45/1.23 – 2.3
1.53–2.29/1.52–2.23
1.38–2.0/1.38–1.94
1.29–2.20/1.25–2.24
1.4–2.45/1.27–1.98
1.45–2.15/1.35–1.98
1.44–2.0/1.34–1.98
Mitral inflow deceleration time – msec
       
   Mean
48.6/48.2
50.2/50.0
47.0/48.2
46.8/46.3
47.7/47.6
50.8/49.3
49.8/49.3
   SD
3.4/3.2
4.7/4.5
2.5/4.9
3.1/2.58
2.6/2.1
3.7/2.5
3.5/3.1
   Range
43–56/43–55
46 – 57/45–56
44–50/43–55
43–52/44–50
43–50/45–50
45–55/47–53
46–56/45–54
Tissue Doppler E'-cm/s
       
   Mean
2.8/2.9
2.87/2.95
2.74/2.80
2.65/3.02
2.8/2.8
2.78/2.75
2.75/2.91
   SD
0.28/0.27
0.12/0.10
0.22/0.38
0.41/0.18
0.23/0.36
0.22/0.25
0.28/0.17
   Range
2.2 – 3.4/2.3 – 3.4
2.7–3.9/2.3 – 3.4
2.4–3.0/2.4 – 3.4
2.2–3.4/2.8 – 3.3
2.6–3.1/2.3–3.4
2.4–3.0/2.4–3.0
2.32–3.1/2.7–3.2
Tissue Doppler A'-cm/s
       
   Mean
2.1/2.1
2.1/1.73
2.12/2.22
2.3/2.3
2.16/1.88
2.23/2.23
1.89/1.96
   SD
0.3/0.31
0.31/0.26
0.34/0.31
0.08/0.19
0.41/0.34
0.12/0.16
0.29/0.37
   Range
1.49 – 2.90/1.44–2.6
1.7–2.4/1.5 – 2.0
1.6–2.5/1.8 – 2.6
2.2–2.4/2.0–2.5
1.6–2.9/1.5–2.3
2.1–2.4/2.0–2.4
1.49–2.4/1.44–2.4
E to E' ratio
       
   Mean
27.8/26.2
25.4/25.8
26.3/25.9
30.1/26.2
27.7/25.0
27.3/26.5
27.6/27.1
   SD
3.7/3.8
1.17/1.29
2.25/3.99
6.18/3.33
2.2/3.3
3.0/4.5
3.5/4.7
   Range
21.2 – 37.7/20.6–35.4
24.1–26.9/24.0–27.1
24.4–30.0/20.6–30.4
21.2–37.7/20.9 – 29.3
26.3–31.8/21.1–30.4
23 – 30.8/22.3–34.2
23.4–34.2/22.9–35.4
Group 1–6 (see Table 1)
Table 3
Radial and circumferential 2D strain
 
Group 2–6 Before/after therapy
Group 1
Group 2
Group 3
Group 4
Group 5
Group 6
Radial Strain
       
Anterior Strain-%
       
   Mean
21.6/22.4
24.2/22.7
20.6/21.4
22.6/21.6
22.1/22.8
21.8/22.1
21.0/23.5
   SD
4.0/4.0
2.9/1.7
2.4/1.8
3.0/3.6
8.5/6.2
1.5/1.3
1.9/5.2
   Range
12.6–38.0/18.0–36.0
21–28/21–25
18–24/19–24
19–27/18–28
12.6–38.0/18–35
19–23/20–24
18–24/20–36
Inferior Strain – %
       
   Mean
20.0/19.4
21.2/18.5
20.4/19.8
20.5/18.8
21.6/22.5
19.8/18.5
18.4/18.1
   SD
4.3/4.1
2.2/2.6
2.3/2.9
4.5/1.3
6.7/7.5
4.1/2.1
3.5/3.2
   Range
11–35/11–37
18–23/16–22
17–22/15–22
17–29/17–21
17–35/16–37
12–23/16–22
11–24/11–22
Circumferential strain
       
Anterior Strain-%
       
   Mean
-22.1/-22.6
-22.0/-22.0
-22.0/-21.6
-22.0/-21.8
-22.3/23.0
-21.5/23.8
-22.4/-22.8
   SD
2.5/2.5
3.6/1.6
2.3/3.4
0.89/2.7
3.1/2.9
2.8/1.9
3.2/2.0
   Range
17–26.6/18–27
19–26/20–24
18–24/18–26
21–23/18–25
18–25/19–27
19–25/21–26
17–26.6/19–25
Inferior Strain-%
       
   Mean
-18.1/-16.2*
-18.0/-17.2
-17.8/-16.2
-16.8/16.3
-17.6/-16.8
-18.3/-16.3
-19.6/-15.7
   SD
2.5/2.9
2.2/3.3
1.6/3.6
0.76/1.2
2.1/2.8
1.7/1.5
3.8/4.5
   Range
14–25/9–22
16–21/14–21
16–19/12–22
16–18/15–18
15–21/13–21
16–21/14–18
14–25/9–22
Group 1–6 (see Table 1)

2D strain echocardiography measurements

The changes of values for radial and circumferential contraction were summarized in Table 3. There are heterogeneous values of circumferential strain: circumferential strain baseline values of the anterior wall were higher compared with values of the inferior wall in all animals: 22.0 ± 2.2 vs 17.5 ± 3.1%; P = 0.001).
In all rats after treatment, the strain profiles demonstrated a postsystolic thickening pattern with circumferential strain in the inferior wall segment, but not in the control group (figures 8+9).
Radial strain parameters were not significantly affected by the type of treatment (Table 3). Circumferential strain of the inferior wall was reduced after treatment in group 6 (P = 0.02); and compared with the group 1 (controls) the circumferential strain values were reduced after follow-up in the overall treatment group (group 1: -18.0 ± 2.1 before and -17.25 ± 3.3% after vs group 2–6: -18.1 ± 2.5 before and -16.2 ± 2.9% after; P = 0.001). Circumferential strain between the single treatment groups were not significant different (table 3, figures 10, 11).

Discussion

This is the first study demonstrating the feasibility of 2D strain echocardiography in rats for noninvasive quantification of regional ventricular function before and after oncological treatment. We could show that conventional systolic and diastolic parameters remained unaffected by the treatment, whereas circumferential 2D strain of the inferior wall was slightly, but significantly reduced after the treatment without differences between the single treatment groups.
Previous studies with animal models have examined a wide variety of cardiac diseases and therapies with a trend from invasive to non-invasive hemodynamic assessment in recent years.
M-mode and 2D echocardiography are adequate in the absence of regional wall-motion abnormalities. However, the small size of the rat heart and the relatively fast heart rate preclude accurate measurements in case of regional wall-motion abnormalities Previous studies demonstrated that the myocardial velocity gradient derived from Doppler tissue imaging was impaired in rats with pressure overload-induced left ventricular hypertrophy [6]. Strain and strain rate (SR) are useful for quantification of changes and spatial distribution of regional contractile function in rats [7].
Cytostatic agents, surgical procedures, and anesthetic agents are known to have effects on myocardial function. Therefore, the choice of anesthetic agent and the potentially cardiotoxic therapy have the potential to affect echocardiographic data directly [8]. Mitomycine and gemcitabine have the potential for a decrease of contractility and direct cardiotoxic effects. Xylazine, however, is considered an clonidine analog, which can result in hypotention and bradycardia, i.e. counteracting the global cardiovascular effects of ketamine. Ketamine has been previously shown in animal models to negatively affect diastolic function [9]. However, these studies were conducted in the presence of pharmacologic blockade of the autonomic nervous system, which was not the case on our rats. In our study, LV dimensions, EF, and diastolic function were not significantly affected by the sedation or surgical plus oncological therapy.
It was assumed that left-ventricular long-axis function may be more sensitive to ischemia than short-axis function, others could demonstrate that circumferential strain reduction and disorders in twisting are very early signs of myocardial damage in some entities [10, 11]. Serri et al. demonstrated that 2D strain echocardiography identified early, subclinical global systolic dysfunction in patients with hypertrophic cardiomyopathy [11]. Thus, TDI and 2D strain echocardiographic data are complementary to short axis scans (indicating wall thickening) and to non-contrast harmonic imaging echocardiography (endocardial border detection).
In both in vitro and in vivo models, non-Doppler 2D strain echocardiography demonstrated a good correlation and agreement with sonomicrometry values under different contractile conditions [12, 13]. Strain and SR measurements that are obtained by the non-Doppler 2D strain echocardiograpahy correlate well with tissue Doppler-derived measurements [5]. Compared to TDI based echocardiography, non TDI-2D-strain seems to have a particularly low inter- and intraobserver variability [12, 14]
TDI- and non Doppler-2D strain echocardiography permit quantitative assessment of global and regional ventricular function [12] and could therefore improve the diagnostic accuracy especially for the inexperienced observer to detect regional wall motion abnormalities. Hirano et al. [7] found that absolute peak systolic strain values were consistently 20% lower than percent wall thickening. This difference could result from the calculation distance of SR used in their study, which might not have been adapted to the rat heart size. The assessment of percent change in SR and strain remains useful.
In contrast to other studies, we could not see postsystolic thickening or systolic wall thinning, under ischemic conditions [7].
Our findings regarding a possible temporary disturbance of the LV torsion (decreased circumferential deformation) due to possible afterload mismatch is in accordance to first human findings indicating reduced and delayed diastolic untwisting with aging [10], and uniformly decreased segmental LV torsion in patients with amyloid-related cardiomyopathy measured with 2D strain echocardiography [11].

Conclusion

In conclusion, our results demonstrate a high technical reproducibility and diagnostic accuracy with both good spatial and temporal resolution of conventional 2D-, TDI- and Non-Doppler 2D strain echocardiography.
We conclude that the demonstrated negative effect on circumferential strain of the inferior wall was a general effect of the sedation plus oncological therapy and not induced by one special modality of therapy. Deformation assessment with non-Doppler 2D strain echocardiography is more sensitive than conventional echocardiography for assessing myocardial dysfunction in rats under oncological treatment.
Non-Doppler 2D strain echocardiography represents a new, powerful method for the evaluation and quantification of global and regional myocardial function for experimental in vivo protocols in small animals.

Limitations

The methods used in this study were not compared to a gold standard technique (e.g. MRI, sonomicrometry) as these methods were not part of the protocol.
The heart rate in the animals was greater than 300/min, even under anesthetic conditions. The frame rate had to be set between 180 and 210 for tissue Doppler measurements and between 60 and 80 for non-Doppler 2D strain calculations, in order to balance the requirements for temporal and spatial resolution.
Deformation measurement is limited in the short axis views due to twisting and swinging in the azimuthal plane of the heart and the movement by respiration. We preferred these views for deformation calculation because of the difficulty in acquiring good apical images as previously described [7].
Histological examinations and follow-up examinations were not performed. We can only speculate about the temporary character of the changes of circumferential strain values in the treatment group.

Acknowledgements

We acknowledge B. Bierotte, U. Meschter; Ch. Watzke (GE-Vingmed, Germany) for their assistance and support. We are grateful to Ch. Scholz for her excellent technical assistance.
Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution License ( https://​creativecommons.​org/​licenses/​by/​2.​0 ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Competing interests

The author(s) declare that they have no competing interests.

Authors' contributions

JH, FK and ACB have designed and performed the study and have written the manuscript. JH and FK have equally contributed to this study. JH, FK, ACB SE, MB, AG, AP, GB have performed echocardiographic measurements and participated in the study design and coordination. JH, CJ and JM have performed the oncological and surgical therapy. KW has supported the statistical analysis of the study. All authors have read and approved the final manuscript.
Literatur
1.
Zurück zum Zitat Watson LE, Sheth M, Denyer RF, Dostal DE: Baseline echocardiographic values for adult male rats. J Am Soc Echocardiogr 2004, 17: 161-167. 10.1016/j.echo.2003.10.010CrossRefPubMed Watson LE, Sheth M, Denyer RF, Dostal DE: Baseline echocardiographic values for adult male rats. J Am Soc Echocardiogr 2004, 17: 161-167. 10.1016/j.echo.2003.10.010CrossRefPubMed
2.
Zurück zum Zitat Vogel M, Schmidt MR, Kristiansen SB, Cheung M, White PA, Sorensen K, Redington AN: Validation of myocardial acceleration during isovolumic contraction as a novel noninvasive index of right ventricular contractility. Comparison with ventricular pressure-volume relations in an animal model. Circulation 2002, 105: 1693-1699. 10.1161/01.CIR.0000013773.67850.BACrossRefPubMed Vogel M, Schmidt MR, Kristiansen SB, Cheung M, White PA, Sorensen K, Redington AN: Validation of myocardial acceleration during isovolumic contraction as a novel noninvasive index of right ventricular contractility. Comparison with ventricular pressure-volume relations in an animal model. Circulation 2002, 105: 1693-1699. 10.1161/01.CIR.0000013773.67850.BACrossRefPubMed
3.
Zurück zum Zitat Borges AC, Knebel F, Eddicks S, Panda A, Schattke S, Witt C, Baumann G: Right ventricular function assessed by two-dimensional strain and tissue Doppler echocardiography in patients with pulmonary arterial hypertension and effect of vasodilator therapy. Am J Cardiol 2006, 98: 530-534. 10.1016/j.amjcard.2006.02.060CrossRefPubMed Borges AC, Knebel F, Eddicks S, Panda A, Schattke S, Witt C, Baumann G: Right ventricular function assessed by two-dimensional strain and tissue Doppler echocardiography in patients with pulmonary arterial hypertension and effect of vasodilator therapy. Am J Cardiol 2006, 98: 530-534. 10.1016/j.amjcard.2006.02.060CrossRefPubMed
4.
Zurück zum Zitat Leitman M, Lysyansky P, Sidenko S, Shir W, Peleg E, Binenbaum M, Kaluski E, Karkover R, Vered Z: Two-dimensional strain a novel software for real-time quantitative echocardiographic assessment of myocardial function. J Am Soc Echocardiogr 2004, 17: 1021-1029. 10.1016/j.echo.2004.06.019CrossRefPubMed Leitman M, Lysyansky P, Sidenko S, Shir W, Peleg E, Binenbaum M, Kaluski E, Karkover R, Vered Z: Two-dimensional strain a novel software for real-time quantitative echocardiographic assessment of myocardial function. J Am Soc Echocardiogr 2004, 17: 1021-1029. 10.1016/j.echo.2004.06.019CrossRefPubMed
5.
Zurück zum Zitat Heimdahl A, Stoylen A, Torp H, Skjaerpe T: Real-time strain rate imaging of the left ventricle by ulrasound. J Am Soc Echocardiogr 1998, 11: 1013-1019. 10.1016/S0894-7317(98)70151-8CrossRef Heimdahl A, Stoylen A, Torp H, Skjaerpe T: Real-time strain rate imaging of the left ventricle by ulrasound. J Am Soc Echocardiogr 1998, 11: 1013-1019. 10.1016/S0894-7317(98)70151-8CrossRef
6.
Zurück zum Zitat Derumeaux G, Mulder P, Richard V, Chagraoui A, Nafeh C, Bauer F: Tissue Doppler imaging differentiates physiological from pathological pressure-overlaod left ventricular hypertrophy in rats. Circulation 2002, 105: 1602-1608. 10.1161/01.CIR.0000012943.91101.D7CrossRefPubMed Derumeaux G, Mulder P, Richard V, Chagraoui A, Nafeh C, Bauer F: Tissue Doppler imaging differentiates physiological from pathological pressure-overlaod left ventricular hypertrophy in rats. Circulation 2002, 105: 1602-1608. 10.1161/01.CIR.0000012943.91101.D7CrossRefPubMed
7.
Zurück zum Zitat Hirano T, Asanuma T, Azakami R, Okuda K, Ishikura F, Beppu S: Noninvasive quantification of regional ventricular function in rats: assessmant of serial change and spatial distribution using ultrasound strain analysis. J Am Soc Echocardiogr 2005, 18: 907-912. 10.1016/j.echo.2005.01.009CrossRefPubMed Hirano T, Asanuma T, Azakami R, Okuda K, Ishikura F, Beppu S: Noninvasive quantification of regional ventricular function in rats: assessmant of serial change and spatial distribution using ultrasound strain analysis. J Am Soc Echocardiogr 2005, 18: 907-912. 10.1016/j.echo.2005.01.009CrossRefPubMed
8.
Zurück zum Zitat Plante E, Lachance D, Roussel E, Drolet MC, Arsenault M, Couet J: Impact of anesthesia on echocardiographic evaluation of systolic and diastolic function in rats. J Am Soc Echocardiogr 2006, 19: 1520-1525. 10.1016/j.echo.2006.06.011CrossRefPubMed Plante E, Lachance D, Roussel E, Drolet MC, Arsenault M, Couet J: Impact of anesthesia on echocardiographic evaluation of systolic and diastolic function in rats. J Am Soc Echocardiogr 2006, 19: 1520-1525. 10.1016/j.echo.2006.06.011CrossRefPubMed
9.
Zurück zum Zitat Pagel PS, Schmeling WT, Kampine JP, Warltier DC: Alteration of canine left ventricular diastolic function by intravenous anesthetics in vivo: ketamine and propofol. Anesthesiology 1992, 76: 419-425.CrossRefPubMed Pagel PS, Schmeling WT, Kampine JP, Warltier DC: Alteration of canine left ventricular diastolic function by intravenous anesthetics in vivo: ketamine and propofol. Anesthesiology 1992, 76: 419-425.CrossRefPubMed
10.
Zurück zum Zitat Takeuchi M, Nakai H, Kokumai M, Nishikage T, Otani S, Lang RM: Age-related changes in left ventricular twist assessed by two-dimensional speckle-tracking imaging. J Am Soc Echocardiogr 2006, 19: 1077-1084. 10.1016/j.echo.2006.04.011CrossRefPubMed Takeuchi M, Nakai H, Kokumai M, Nishikage T, Otani S, Lang RM: Age-related changes in left ventricular twist assessed by two-dimensional speckle-tracking imaging. J Am Soc Echocardiogr 2006, 19: 1077-1084. 10.1016/j.echo.2006.04.011CrossRefPubMed
11.
Zurück zum Zitat Serri K, Reant P, Lafitte M, Berhouet M, Le Bouffos V, Roudaut R, Lafitte S: Global and regional myocardial function quantification by two-dimensional strain. J Am Coll Cardiol 2006, 47: 1175-1181. 10.1016/j.jacc.2005.10.061CrossRefPubMed Serri K, Reant P, Lafitte M, Berhouet M, Le Bouffos V, Roudaut R, Lafitte S: Global and regional myocardial function quantification by two-dimensional strain. J Am Coll Cardiol 2006, 47: 1175-1181. 10.1016/j.jacc.2005.10.061CrossRefPubMed
12.
Zurück zum Zitat Perk G, Tunick PA, Kronzon I: Non-Doppler two-dimensional strain imaging by echocardiography – from technical considerations to clinical applications. J Am Soc Echocardiogr 2007, 20: 234-243. 10.1016/j.echo.2006.08.023CrossRefPubMed Perk G, Tunick PA, Kronzon I: Non-Doppler two-dimensional strain imaging by echocardiography – from technical considerations to clinical applications. J Am Soc Echocardiogr 2007, 20: 234-243. 10.1016/j.echo.2006.08.023CrossRefPubMed
13.
Zurück zum Zitat Korinek J, Wang J, Sengupta PP, Miyazaki C, Kjaergaard J, McMahon E, Abraham TP, Belohlavek M: Two-dimensional strain- a Doppler-independent ultrasound method for quantification of regional deformation: validation in vitro and in vivo. J Am Soc Echocardiogr 2005, 18: 1247-1253. 10.1016/j.echo.2005.03.024CrossRefPubMed Korinek J, Wang J, Sengupta PP, Miyazaki C, Kjaergaard J, McMahon E, Abraham TP, Belohlavek M: Two-dimensional strain- a Doppler-independent ultrasound method for quantification of regional deformation: validation in vitro and in vivo. J Am Soc Echocardiogr 2005, 18: 1247-1253. 10.1016/j.echo.2005.03.024CrossRefPubMed
14.
Zurück zum Zitat Ingul CB, Torp H, Aase SA, Berg S, Stoylen A, Slordahl SA: Automated analysis of strain rate and strain: feasibility and clinical implications. J Am Soc Echocardiogr 2005, 18: 411-418. 10.1016/j.echo.2005.01.032CrossRefPubMed Ingul CB, Torp H, Aase SA, Berg S, Stoylen A, Slordahl SA: Automated analysis of strain rate and strain: feasibility and clinical implications. J Am Soc Echocardiogr 2005, 18: 411-418. 10.1016/j.echo.2005.01.032CrossRefPubMed
Metadaten
Titel
Noninvasive monitoring of myocardial function after surgical and cytostatic therapy in a peritoneal metastasis rat model: assessment with tissue Doppler and non-Doppler 2D strain echocardiography
verfasst von
Jens Hartmann
Fabian Knebel
Stephan Eddicks
Mark Beling
Andrea Grohmann
Alexander Panda
Christoph A Jacobi
Joachim M Müller
Klaus-Dieter Wernecke
Gert Baumann
Adrian C Borges
Publikationsdatum
01.12.2007
Verlag
BioMed Central
Erschienen in
Cardiovascular Ultrasound / Ausgabe 1/2007
Elektronische ISSN: 1476-7120
DOI
https://doi.org/10.1186/1476-7120-5-23

Weitere Artikel der Ausgabe 1/2007

Cardiovascular Ultrasound 1/2007 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.