Skip to main content
Erschienen in: International Orthopaedics 4/2007

01.08.2007 | Original Paper

Observer reliability in evaluating pedicle screw placement using computed tomography

verfasst von: Victor Kosmopoulos, Nicolas Theumann, Stefano Binaghi, Constantin Schizas

Erschienen in: International Orthopaedics | Ausgabe 4/2007

Einloggen, um Zugang zu erhalten

Abstract

Pedicle screw insertion in spinal surgery is a demanding technique with potential risks to neurological structures, for example, within the spinal canal. Assessing screw placement in clinical practice has been performed using plain radiographs and/or mainly axial computed tomography (CT) images. Screw placement using CT image reconstructions in multiple planes has been described, but its reliability has yet to be studied. This study aimed at addressing the clinical issue of interobserver and intraobserver reliability in the use of axial and coronal CT images for the assessment of pedicle screw placement. Fifty nine pedicle screws were studied by two experienced radiologists on two separate occasions. Screw placement was classified as “in”, “out” or “questionable”. On average, 88% and 92% of the screws were classified as “in” by the first and second radiologist, respectively. Intraobserver agreement strength was almost perfect for both observers using either axial or coronal images. Interobserver agreement strength was almost perfect (axial) and substantial (coronal) in the first reading and substantial (axial, coronal) in the second reading. Assessing screw placement in more than one CT imaging plane is not only useful but reliable. Routine use may enhance reporting quality of screw placement by surgeons and radiologists.
Literatur
1.
Zurück zum Zitat Abumi K, Kaneda K, Shono Y, Fujiya M (1999) One-stage posterior decompression and reconstruction of the cervical spine by using pedicle screw fixation systems. J Neurosurg 90(1 Suppl):19–26PubMed Abumi K, Kaneda K, Shono Y, Fujiya M (1999) One-stage posterior decompression and reconstruction of the cervical spine by using pedicle screw fixation systems. J Neurosurg 90(1 Suppl):19–26PubMed
2.
Zurück zum Zitat Boachie-Adjei O, Girardi FP, Bansal M, Rawlins BA (2000) Safety and efficacy of pedicle screw placement for adult spinal deformity with a pedicle-probing conventional anatomic technique. J Spinal Disord 13(6):496–500PubMedCrossRef Boachie-Adjei O, Girardi FP, Bansal M, Rawlins BA (2000) Safety and efficacy of pedicle screw placement for adult spinal deformity with a pedicle-probing conventional anatomic technique. J Spinal Disord 13(6):496–500PubMedCrossRef
3.
Zurück zum Zitat Carbone JJ, Tortolani PJ, Quartararo LG (2003) Fluoroscopically assisted pedicle screw fixation for thoracic and thoracolumbar injuries: technique and short-term complications. Spine 28(1):91–97PubMedCrossRef Carbone JJ, Tortolani PJ, Quartararo LG (2003) Fluoroscopically assisted pedicle screw fixation for thoracic and thoracolumbar injuries: technique and short-term complications. Spine 28(1):91–97PubMedCrossRef
4.
Zurück zum Zitat Carl AL, Khanuja HS, Gatto CA, Matsumoto M, vomLehn J, Schenck J, Rohling K, Lorensen W, Vosburgh K (2000) In vivo pedicle screw placement: image-guided virtual vision. J Spinal Disord 13(3):225–229PubMedCrossRef Carl AL, Khanuja HS, Gatto CA, Matsumoto M, vomLehn J, Schenck J, Rohling K, Lorensen W, Vosburgh K (2000) In vivo pedicle screw placement: image-guided virtual vision. J Spinal Disord 13(3):225–229PubMedCrossRef
5.
Zurück zum Zitat Castro WH, Halm H, Jerosch J, Malms J, Steinbeck J, Blasius S (1996) Accuracy of pedicle screw placement in lumbar vertebrae. Spine 21(11):1320–1324PubMedCrossRef Castro WH, Halm H, Jerosch J, Malms J, Steinbeck J, Blasius S (1996) Accuracy of pedicle screw placement in lumbar vertebrae. Spine 21(11):1320–1324PubMedCrossRef
6.
Zurück zum Zitat Farber GL, Place HM, Mazur RA, Jones DE, Damiano TR (1995) Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography. Spine 1494–1499 Farber GL, Place HM, Mazur RA, Jones DE, Damiano TR (1995) Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography. Spine 1494–1499
7.
Zurück zum Zitat Fayyazi AH, Hugate RR, Pennypacker J, Gelb DE, Ludwig SC (2004) Accuracy of computed tomography in assessing thoracic pedicle screw malposition. J Spinal Disord Tech 17(5):367–371PubMedCrossRef Fayyazi AH, Hugate RR, Pennypacker J, Gelb DE, Ludwig SC (2004) Accuracy of computed tomography in assessing thoracic pedicle screw malposition. J Spinal Disord Tech 17(5):367–371PubMedCrossRef
8.
Zurück zum Zitat Ferrick MR, Kowalski JM, Simmons ED Jr (1997) Reliability of roentgenogram evaluation of pedicle screw position. Spine 22(11):1249–1252, discussion 1253PubMedCrossRef Ferrick MR, Kowalski JM, Simmons ED Jr (1997) Reliability of roentgenogram evaluation of pedicle screw position. Spine 22(11):1249–1252, discussion 1253PubMedCrossRef
9.
Zurück zum Zitat Fleiss JL (1981) Statistical methods for rates and proportions. Wiley, New York, NY, pp 212–236 Fleiss JL (1981) Statistical methods for rates and proportions. Wiley, New York, NY, pp 212–236
10.
Zurück zum Zitat Girardi FP, Cammisa FP Jr, Sandhu HS, Alvarez L (1999) The placement of lumbar pedicle screws using computerised stereotactic guidance. J Bone Joint Surg Br 81(5):825–829PubMedCrossRef Girardi FP, Cammisa FP Jr, Sandhu HS, Alvarez L (1999) The placement of lumbar pedicle screws using computerised stereotactic guidance. J Bone Joint Surg Br 81(5):825–829PubMedCrossRef
11.
Zurück zum Zitat Halm H, Niemeyer T, Link T, Liljenqvist U (2000) Segmental pedicle screw instrumentation in idiopathic thoracolumbar and lumbar scoliosis. Eur Spine J 9(3):191–197PubMedCrossRef Halm H, Niemeyer T, Link T, Liljenqvist U (2000) Segmental pedicle screw instrumentation in idiopathic thoracolumbar and lumbar scoliosis. Eur Spine J 9(3):191–197PubMedCrossRef
12.
Zurück zum Zitat Heary RF, Bono CM, Black M (2004) Thoracic pedicle screws: postoperative computerized tomography scanning assessment. J Neurosurg 100(4 Suppl Spine):325–331PubMed Heary RF, Bono CM, Black M (2004) Thoracic pedicle screws: postoperative computerized tomography scanning assessment. J Neurosurg 100(4 Suppl Spine):325–331PubMed
13.
Zurück zum Zitat Kim HS, Heller JG, Hudgins PA, Fountain JA (2003) The accuracy of computed tomography in assessing cervical pedicle screw placement. Spine 28(21):2441–2446PubMedCrossRef Kim HS, Heller JG, Hudgins PA, Fountain JA (2003) The accuracy of computed tomography in assessing cervical pedicle screw placement. Spine 28(21):2441–2446PubMedCrossRef
14.
Zurück zum Zitat Kim YJ, Lenke LG, Cheh G, Riew KD (2005) Evaluation of pedicle screw placement in the deformed spine using intraoperative plain radiographs: a comparison with computerized tomography. Spine 30(18):2084–2088PubMedCrossRef Kim YJ, Lenke LG, Cheh G, Riew KD (2005) Evaluation of pedicle screw placement in the deformed spine using intraoperative plain radiographs: a comparison with computerized tomography. Spine 30(18):2084–2088PubMedCrossRef
15.
Zurück zum Zitat Kosay C, Akcali O, Berk RH, Erbil G, Alici E (2001) A new method for detecting pedicular wall perforation during pedicle screw insertion. Spine 26(13):1477–1481PubMedCrossRef Kosay C, Akcali O, Berk RH, Erbil G, Alici E (2001) A new method for detecting pedicular wall perforation during pedicle screw insertion. Spine 26(13):1477–1481PubMedCrossRef
16.
Zurück zum Zitat Kotani Y, Abumi K, Ito M, Minami A (2003) Improved accuracy of computer-assisted cervical pedicle screw insertion. J Neurosurg 99(Suppl 3):257–263PubMed Kotani Y, Abumi K, Ito M, Minami A (2003) Improved accuracy of computer-assisted cervical pedicle screw insertion. J Neurosurg 99(Suppl 3):257–263PubMed
17.
18.
Zurück zum Zitat Kuntz C, Maher PC, Levine NB, Kurokawa R (2004) Prospective evaluation of thoracic pedicle screw placement using fluoroscopic imaging. J Spinal Disord Tech 17(3):206–214PubMedCrossRef Kuntz C, Maher PC, Levine NB, Kurokawa R (2004) Prospective evaluation of thoracic pedicle screw placement using fluoroscopic imaging. J Spinal Disord Tech 17(3):206–214PubMedCrossRef
19.
Zurück zum Zitat Laine T, Makitalo K, Schlenzka D, Tallroth K, Poussa M, Alho A (1997) Accuracy of pedicle screw insertion: a prospective CT study in 30 low back patients. Eur Spine J 6(6):402–405PubMedCrossRef Laine T, Makitalo K, Schlenzka D, Tallroth K, Poussa M, Alho A (1997) Accuracy of pedicle screw insertion: a prospective CT study in 30 low back patients. Eur Spine J 6(6):402–405PubMedCrossRef
20.
Zurück zum Zitat Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174PubMedCrossRef Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174PubMedCrossRef
21.
Zurück zum Zitat Learch TJ, Massie JB, Pathria MN, Ahlgren BA, Garfin SR (2004) Assessment of pedicle screw placement utilizing conventional radiography and computed tomography: a proposed systematic approach to improve accuracy of interpretation. Spine 29(7):767–773PubMedCrossRef Learch TJ, Massie JB, Pathria MN, Ahlgren BA, Garfin SR (2004) Assessment of pedicle screw placement utilizing conventional radiography and computed tomography: a proposed systematic approach to improve accuracy of interpretation. Spine 29(7):767–773PubMedCrossRef
22.
Zurück zum Zitat Lee TC, Yang LC, Liliang PC, Su TM, Rau CS, Chen HJ (2004) Single versus separate registration for computer-assisted lumbar pedicle screw placement. Spine 29(14):1585–1589PubMedCrossRef Lee TC, Yang LC, Liliang PC, Su TM, Rau CS, Chen HJ (2004) Single versus separate registration for computer-assisted lumbar pedicle screw placement. Spine 29(14):1585–1589PubMedCrossRef
23.
Zurück zum Zitat Papadopoulos EC, Girardi FP, Sama A, Sandhu HS, Cammisa FP Jr (2005) Accuracy of single-time, multilevel registration in image-guided spinal surgery. Spine J 5(3):263–267, discussion 268,-JunPubMedCrossRef Papadopoulos EC, Girardi FP, Sama A, Sandhu HS, Cammisa FP Jr (2005) Accuracy of single-time, multilevel registration in image-guided spinal surgery. Spine J 5(3):263–267, discussion 268,-JunPubMedCrossRef
24.
Zurück zum Zitat Rampersaud YR, Pik JH, Salonen D, Farooq S (2005) Clinical accuracy of fluoroscopic computer-assisted pedicle screw fixation: a CT analysis. Spine 30(7):E183–E190PubMedCrossRef Rampersaud YR, Pik JH, Salonen D, Farooq S (2005) Clinical accuracy of fluoroscopic computer-assisted pedicle screw fixation: a CT analysis. Spine 30(7):E183–E190PubMedCrossRef
25.
Zurück zum Zitat Roy-Camille R, Saillant G, Berteaux D, Salgado V, Roy-Camille R, Saillant G, Berteaux D, Salgado V (1976) Osteosynthesis of thoraco-lumbar spine fractures with metal plates screwed through the vertebral pedicles. Reconst Surg Traumatol 15:2–16 Roy-Camille R, Saillant G, Berteaux D, Salgado V, Roy-Camille R, Saillant G, Berteaux D, Salgado V (1976) Osteosynthesis of thoraco-lumbar spine fractures with metal plates screwed through the vertebral pedicles. Reconst Surg Traumatol 15:2–16
26.
Zurück zum Zitat Sapkas GS, Papadakis SA, Stathakopoulos DP, Papagelopoulos PJ, Badekas AC, Kaiser JH (1999) Evaluation of pedicle screw position in thoracic and lumbar spine fixation using plain radiographs and computed tomography. A prospective study of 35 patients. Spine 24(18):1926–1929PubMedCrossRef Sapkas GS, Papadakis SA, Stathakopoulos DP, Papagelopoulos PJ, Badekas AC, Kaiser JH (1999) Evaluation of pedicle screw position in thoracic and lumbar spine fixation using plain radiographs and computed tomography. A prospective study of 35 patients. Spine 24(18):1926–1929PubMedCrossRef
27.
Zurück zum Zitat Schwarzenbach O, Berlemann U, Jost B, Visarius H, Arm E, Langlotz F, Nolte LP, Ozdoba C (1997) Accuracy of computer-assisted pedicle screw placement. An in vivo computed tomography analysis. Spine 22(4):452–458PubMedCrossRef Schwarzenbach O, Berlemann U, Jost B, Visarius H, Arm E, Langlotz F, Nolte LP, Ozdoba C (1997) Accuracy of computer-assisted pedicle screw placement. An in vivo computed tomography analysis. Spine 22(4):452–458PubMedCrossRef
28.
Zurück zum Zitat Vaccaro AR, Rizzolo SJ, Balderston RA, Allardyce TJ, Garfin SR, Dolinskas C, An HS (1995) Placement of pedicle screws in the thoracic spine. Part II: an anatomical and radiographic assessment. J Bone Joint Surg Am 77:1200–1206PubMed Vaccaro AR, Rizzolo SJ, Balderston RA, Allardyce TJ, Garfin SR, Dolinskas C, An HS (1995) Placement of pedicle screws in the thoracic spine. Part II: an anatomical and radiographic assessment. J Bone Joint Surg Am 77:1200–1206PubMed
29.
Zurück zum Zitat Weinstein JN, Spratt KF, Spengler D, Brick C, Reid S (1988) Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement [see comment]. Spine 13:1012–1018PubMedCrossRef Weinstein JN, Spratt KF, Spengler D, Brick C, Reid S (1988) Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement [see comment]. Spine 13:1012–1018PubMedCrossRef
30.
Zurück zum Zitat Whitecloud TS, Skalley TC, Cook SD, Morgan EL (1989) Roentgenographic measurement of pedicle screw penetration. [Review] [34 refs]. Clin Orthop 245:57–68PubMed Whitecloud TS, Skalley TC, Cook SD, Morgan EL (1989) Roentgenographic measurement of pedicle screw penetration. [Review] [34 refs]. Clin Orthop 245:57–68PubMed
31.
Zurück zum Zitat Youkilis AS, Quint DJ, McGillicuddy JE, Papadopoulos SM (2001) Stereotactic navigation for placement of pedicle screws in the thoracic spine. Neurosurgery 48(4):771–778, discussion 778–779PubMedCrossRef Youkilis AS, Quint DJ, McGillicuddy JE, Papadopoulos SM (2001) Stereotactic navigation for placement of pedicle screws in the thoracic spine. Neurosurgery 48(4):771–778, discussion 778–779PubMedCrossRef
Metadaten
Titel
Observer reliability in evaluating pedicle screw placement using computed tomography
verfasst von
Victor Kosmopoulos
Nicolas Theumann
Stefano Binaghi
Constantin Schizas
Publikationsdatum
01.08.2007
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 4/2007
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-006-0230-8

Weitere Artikel der Ausgabe 4/2007

International Orthopaedics 4/2007 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.