Skip to main content
Erschienen in: Journal of Interventional Cardiac Electrophysiology 3/2019

Open Access 23.10.2018 | Case Reports

Ortner’s syndrome after cryoballoon ablation

verfasst von: Grzegorz Karkowski, Stanislas Kielczewski, Jacek Lelakowski, Marcin Kuniewicz

Erschienen in: Journal of Interventional Cardiac Electrophysiology | Ausgabe 3/2019

download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN
We present the case of a 54-year-old patient with hypertension, obesity (BMI, 31), paroxysmal atrial fibrillation EHRA class III B, a CHADSVASc score of 4, a HAS-BLED score of 2, a history of TIA, and an ineffective epicardial ablation for atrial fibrillation using the COBRA Fusion system with simultaneous ligation of the left atrial appendage 8 months prior.
For the repeat ablation procedure, we selected cryoballoon ablation (Arctic Front Advance 28 mm). Using the Achieve diagnostic catheter, we identified potentials in the left superior pulmonary vein (LSPV) with no exit block. After contrast injection, ablation of the LSPV was performed at − 58 °C until disappearance of pulmonary vein potentials in 30-s applications (cumulative time 150 s). The final result was complete pulmonary venous isolation together with exit and entrance block. During the procedure, the patient was sedated and anesthetized with midazolam and fentanyl. Hoarseness was observed in the early postoperative period. A laryngological examination revealed a left unilateral vocal fold paralysis. A 14-day course of oral prednisone did not resolve the hoarseness.
In the post-cryoballoon ablation heart CT with contrast, a scar was noted along the epicardial ablation with a change in the architecture of the roof of the left atrium (Fig. 1). After ineffective steroid therapy, we initiated a 10-week course of intramuscularly administered Milgamma (vitamin B complex, cyanocobalamin 1 mg, pyridoxine 100 mg, and thiamine 100 mg). After 7 days of this therapy, the hoarseness resolved. At follow-up 4 months after the procedure, neither the atrial fibrillation nor the hoarseness has recurred.
Ablation is an important and constantly developing method of treatment of atrial fibrillation (AF) [1]. Ablations using the COBRA Fusion system may be incomplete in the anterior-superior part of the LSPV due to fat thickness along the roofline [2]. LRLN injury was described once during RF ablation over the roof line in close relation to LSPV [3], but never before during cryoballoon ablation. Authors suggested deformation of the atrial wall by a stiff electrode could increase the likelihood of contact with the LRLN [3]. In our case, there was a post-lesion box change in the atrial architecture on the roof after the first ablation which could cause the same effect. This meant the LRLN was within a range of cryoenergy (− 58 °C) that was delivered in the LSPV. These circumstances support the diagnosis of iatrogenic Ortner’s syndrome, which was first described in 1897.
Recovery from laryngeal nerve palsy after thermal damage might be spontaneous or with a late response to prednisone therapy, but the effectiveness in recovery after administration of vitamin B combination complex was interesting.
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
download
DOWNLOAD
print
DRUCKEN

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Innere Medizin

Kombi-Abonnement

Mit e.Med Innere Medizin erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes Innere Medizin, den Premium-Inhalten der internistischen Fachzeitschriften, inklusive einer gedruckten internistischen Zeitschrift Ihrer Wahl.

Literatur
1.
Zurück zum Zitat Kirchhof P, Benussi S, Kotecha D, Ahlsson A, Atar D, Casadei B, et al. 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS. Eur Heart J. 2016;37:2893–962.CrossRefPubMed Kirchhof P, Benussi S, Kotecha D, Ahlsson A, Atar D, Casadei B, et al. 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS. Eur Heart J. 2016;37:2893–962.CrossRefPubMed
2.
Zurück zum Zitat Osmanick P, et al. Electrophysiological findings after surgical thoracoscopic atrial fibrillation ablation. Heart Rythm. 2016 Jun;13(6):1246–52.CrossRef Osmanick P, et al. Electrophysiological findings after surgical thoracoscopic atrial fibrillation ablation. Heart Rythm. 2016 Jun;13(6):1246–52.CrossRef
3.
Zurück zum Zitat Rakesh K, et al. Transient left recurrent laryngeal nerve palsy following catheter ablation of atrial fibrillation. Heart Rhythm. 2005;2:182–4.CrossRef Rakesh K, et al. Transient left recurrent laryngeal nerve palsy following catheter ablation of atrial fibrillation. Heart Rhythm. 2005;2:182–4.CrossRef
Metadaten
Titel
Ortner’s syndrome after cryoballoon ablation
verfasst von
Grzegorz Karkowski
Stanislas Kielczewski
Jacek Lelakowski
Marcin Kuniewicz
Publikationsdatum
23.10.2018
Verlag
Springer US
Erschienen in
Journal of Interventional Cardiac Electrophysiology / Ausgabe 3/2019
Print ISSN: 1383-875X
Elektronische ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-018-0466-4

Weitere Artikel der Ausgabe 3/2019

Journal of Interventional Cardiac Electrophysiology 3/2019 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.