Abstract

Study design

Report of case series

Objective

To report a problem with bioabsorbable poly-l-lactide-co-d, l-lactide, PLDLLA, posterior lumbar instrumented fusion (PLIF) cage implants.

Summary of background data

Synthetic bioabsorbable implants have recently been introduced to spinal surgery and their indications and applications are still being explored. There is evidence that the use of bioabsorbable cages may be of benefit in interbody spinal fusion.

Methods

We present a case series of nine patients who have undergone PLIF with bioabsorbable cages in the lumbar spine.

Results

At follow-up over at least 1 year, four of these patients were found to have osteolysis around the implant on CT scanning. One of these patients underwent an operation to remove the cage and histology sent during surgery suggested that the implant had caused the bone loss and there was no evidence of infection. Another patient had ongoing pain in relation to the lysis, while the other two patients with lysis remained asymptomatic.

Conclusions

PLDLLA cage, which has high osteolytic nature, is considered not suitable as a fusion cage.
Literatur
1.
Zurück zum Zitat Kuklo TR, Rosner MK, Polly DW (2004) Computerised tomography evaluation of resorbable implants after transforaminal lumbar interbody fusion. Neurosurg Focus 16(3):E10PubMedCrossRef Kuklo TR, Rosner MK, Polly DW (2004) Computerised tomography evaluation of resorbable implants after transforaminal lumbar interbody fusion. Neurosurg Focus 16(3):E10PubMedCrossRef
2.
Zurück zum Zitat Lowe TG, Coe JD (2002) Resorbable polymer implants in unilateral transforaminal lumbar interbody fusion. J Neurosurg 97(4 suppl):464–467PubMed Lowe TG, Coe JD (2002) Resorbable polymer implants in unilateral transforaminal lumbar interbody fusion. J Neurosurg 97(4 suppl):464–467PubMed
3.
Zurück zum Zitat Vaccaro AR, Robbins MM, Madigan L, Hillibrand AS et al (2004) Early findings in a pilot study of anterior cervical fusion in which bioabsorbable interbody spacers were used in the treatment of cervical degenerative disease. Neurosurg Focus 16(3):E7PubMedCrossRef Vaccaro AR, Robbins MM, Madigan L, Hillibrand AS et al (2004) Early findings in a pilot study of anterior cervical fusion in which bioabsorbable interbody spacers were used in the treatment of cervical degenerative disease. Neurosurg Focus 16(3):E7PubMedCrossRef
4.
Zurück zum Zitat Franco A, Nina P, Arpino L, Torelli G (2007) Use of resorbable implants for symptomatic cervical spondylosis: experience on 16 consecutive patients. J Neurosurg Sci 51(4):169–175PubMed Franco A, Nina P, Arpino L, Torelli G (2007) Use of resorbable implants for symptomatic cervical spondylosis: experience on 16 consecutive patients. J Neurosurg Sci 51(4):169–175PubMed
5.
Zurück zum Zitat Lazennec JY, Madi A, Rousseau MA, Roger B, Saillant G (2006) Evaluation of the 96/4 PLDLLA polymer resorbable lumbar interbody cage in a long term animal model. Eur Spine J 15(10):1545–1553PubMedCrossRef Lazennec JY, Madi A, Rousseau MA, Roger B, Saillant G (2006) Evaluation of the 96/4 PLDLLA polymer resorbable lumbar interbody cage in a long term animal model. Eur Spine J 15(10):1545–1553PubMedCrossRef
6.
Zurück zum Zitat Krijnen MR, Smit TH, Strijkers GJ, Wuisman PI et al (2004) The use of high-resolution magnetic resonance imaging for monitoring interbody fusion and bioabsorbable cages: an ex vivo pilot study. Neurosurg Focus 16(3):E3PubMedCrossRef Krijnen MR, Smit TH, Strijkers GJ, Wuisman PI et al (2004) The use of high-resolution magnetic resonance imaging for monitoring interbody fusion and bioabsorbable cages: an ex vivo pilot study. Neurosurg Focus 16(3):E3PubMedCrossRef
7.
Zurück zum Zitat Toth JM, Estes BT, Wang M, Cornwall GB et al (2002) Evaluation of 70/30 poly (l-lactide-co-d, l-lactide) for use as a resorbable interbody fusion cage. J Neurosurg 97(4 suppl):423–432PubMed Toth JM, Estes BT, Wang M, Cornwall GB et al (2002) Evaluation of 70/30 poly (l-lactide-co-d, l-lactide) for use as a resorbable interbody fusion cage. J Neurosurg 97(4 suppl):423–432PubMed
8.
Zurück zum Zitat Jiya T, Smit T, Deddens J, Mullender M (2009) Posterior lumbar interbody fusion using nonresorbable poly-ether-ether-ketone versus resorbable poly-l-lactide-co-d, l-lactide fusion devices: a prospective, randomized study to assess fusion and clinical outcome. Spine 34(3):233–237PubMedCrossRef Jiya T, Smit T, Deddens J, Mullender M (2009) Posterior lumbar interbody fusion using nonresorbable poly-ether-ether-ketone versus resorbable poly-l-lactide-co-d, l-lactide fusion devices: a prospective, randomized study to assess fusion and clinical outcome. Spine 34(3):233–237PubMedCrossRef
9.
Zurück zum Zitat Herceg M, Slosar PJ, Reynolds JR et al (2004) Rapid subsidence in lumbar interbody fusions with resorbable implants. Presented at the annual meeting of the North American Spine Society, Chicago, 28 October 2004 Herceg M, Slosar PJ, Reynolds JR et al (2004) Rapid subsidence in lumbar interbody fusions with resorbable implants. Presented at the annual meeting of the North American Spine Society, Chicago, 28 October 2004
10.
Zurück zum Zitat David SM, Gruber HE, Mayer RA Jr et al (1999) Lumbar spinal fusion using recombinant human bone morphogenetic protein in the canine. A comparison of three dosages and two carriers. Spine 24:1973–1979PubMedCrossRef David SM, Gruber HE, Mayer RA Jr et al (1999) Lumbar spinal fusion using recombinant human bone morphogenetic protein in the canine. A comparison of three dosages and two carriers. Spine 24:1973–1979PubMedCrossRef
11.
Zurück zum Zitat van Dijk M, Smit TH, Burger EH et al (2002) Bioabsorbable poly-L-lactic acid cages for lumbar interbody fusion: three-year follow-up radiographic, histological, and histomorphometric analysis in goats. Spine 27:2706–2714PubMedCrossRef van Dijk M, Smit TH, Burger EH et al (2002) Bioabsorbable poly-L-lactic acid cages for lumbar interbody fusion: three-year follow-up radiographic, histological, and histomorphometric analysis in goats. Spine 27:2706–2714PubMedCrossRef
12.
Zurück zum Zitat van Dijk M, Tunc DC, Smit TH et al (2002) In vitro and in vivo degradation of bioabsorbable PLLA spinal fusion cages. J Biomed Mater Res 63:752–759PubMedCrossRef van Dijk M, Tunc DC, Smit TH et al (2002) In vitro and in vivo degradation of bioabsorbable PLLA spinal fusion cages. J Biomed Mater Res 63:752–759PubMedCrossRef
13.
Zurück zum Zitat Kandziora F, Pflugmacher R, Scholz M, Eindorf T, Schnake KJ, Has NP (2004) Bioabsorbable interbody cages in a sheep cervical spine fusion model. Spine 29(17):1845–1855PubMedCrossRef Kandziora F, Pflugmacher R, Scholz M, Eindorf T, Schnake KJ, Has NP (2004) Bioabsorbable interbody cages in a sheep cervical spine fusion model. Spine 29(17):1845–1855PubMedCrossRef
14.
Zurück zum Zitat Eindorf T, Pflugmacher R, Koch C et al (2005) Spinal fusion with bioresorbable cages—severe degradation effects. Eur Spine J 14:S20 Eindorf T, Pflugmacher R, Koch C et al (2005) Spinal fusion with bioresorbable cages—severe degradation effects. Eur Spine J 14:S20
Metadaten
Titel
Osteolysis following resorbable poly-l-lactide-co-d, l-lactide PLIF cage use: a review of cases
verfasst von
Andrew Frost
Elmanzour Bagouri
Mark Brown
Vinay Jasani
Publikationsdatum
01.03.2012
Verlag
Springer-Verlag
Erschienen in
European Spine Journal / Ausgabe 3/2012
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-011-2002-4

Weitere Artikel der Ausgabe 3/2012

European Spine Journal 3/2012 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.